Volumn 17, Issue 9, 1996, Pages 865-871

Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions

Author keywords

Hip joint simulator; Lubricant; Transfer; UHMWPE; Wear debris

Indexed keywords

BIOMATERIALS; HIP PROSTHESES; JOINTS (ANATOMY); LUBRICANTS; MORPHOLOGY; WEAR OF MATERIALS;

EID: 0030152397     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/0142-9612(96)83281-9     Document Type: Article
Times cited : (108)

References (18)
  • 1
    • 0028439173 scopus 로고
    • Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints
    • Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med Eng Phys 1994; 16: 229-236.
    • (1994) Med Eng Phys , vol.16 , pp. 229-236
    • Derbyshire, B.1    Fisher, J.2    Dowson, D.3    Hardaker, C.4    Brummitt, K.5
  • 2
    • 0027724402 scopus 로고
    • The effect of transfer film and surface roughness on the wear of lubricated ultra-high-molecular-weight polyethylene
    • Cooper JR, Dowson D, Fisher J. The effect of transfer film and surface roughness on the wear of lubricated ultra-high-molecular-weight polyethylene. Clin Mater 1993; 14: 295-302.
    • (1993) Clin Mater , vol.14 , pp. 295-302
    • Cooper, J.R.1    Dowson, D.2    Fisher, J.3
  • 3
    • 0025834740 scopus 로고
    • Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy
    • Kumar P, Oka M, Ikeuchi K, et al. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res 1991; 25: 813-828.
    • (1991) J Biomed Mater Res , vol.25 , pp. 813-828
    • Kumar, P.1    Oka, M.2    Ikeuchi, K.3
  • 4
    • 0019596364 scopus 로고
    • Wear of artificial joint materials II twelve-channel wear-screening device: Correlation of experimental and clinical results
    • McKellop HA. Wear of artificial joint materials II twelve-channel wear-screening device: correlation of experimental and clinical results. Eng Med 1981; 10(3): 123-136.
    • (1981) Eng Med , vol.10 , Issue.3 , pp. 123-136
    • McKellop, H.A.1
  • 5
    • 0028836831 scopus 로고
    • The origin of submicron polyethylene wear debris in total hip arthroplasty
    • McKellop HA, Campbell P, Park SH, et al. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop Rel Res, 1995; 311: 3-20.
    • (1995) Clin Orthop Rel Res , vol.311 , pp. 3-20
    • McKellop, H.A.1    Campbell, P.2    Park, S.H.3
  • 6
  • 7
    • 0028486355 scopus 로고
    • Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator
    • Saikko V. Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator. Wear 1994; 176: 207-212.
    • (1994) Wear , vol.176 , pp. 207-212
    • Saikko, V.1
  • 8
    • 0027519893 scopus 로고
    • Wear of polyethylene acetabular cups against alumina femoral heads
    • Saikko V. Wear of polyethylene acetabular cups against alumina femoral heads. Acta Orthop Scand 1993; 64(5): 507-512.
    • (1993) Acta Orthop Scand , vol.64 , Issue.5 , pp. 507-512
    • Saikko, V.1
  • 9
    • 0018040867 scopus 로고
    • A method for the quantitative recovery of polyethylene wear debris from the simulated service of total joint prostheses
    • Rose RM, Schneider H, Ries M, et al. A method for the quantitative recovery of polyethylene wear debris from the simulated service of total joint prostheses. Wear 1978; 51: 77-84.
    • (1978) Wear , vol.51 , pp. 77-84
    • Rose, R.M.1    Schneider, H.2    Ries, M.3
  • 10
    • 0028249112 scopus 로고
    • A hip wear simulator for the evaluation of biomaterials in hi-arthroplasty components
    • Mejia LC, Brierley T. A hip wear simulator for the evaluation of biomaterials in hi-arthroplasty components. Biomed Mater Eng 1994; 4: 259-271.
    • (1994) Biomed Mater Eng , vol.4 , pp. 259-271
    • Mejia, L.C.1    Brierley, T.2
  • 12
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • Paul, JP. Forces transmitted by joints in the human body. Proc Instn Mech Eng 1966; 181 (part 3J): 8-15.
    • (1966) Proc Instn Mech Eng , vol.181 , Issue.PART 3J , pp. 8-15
    • Paul, J.P.1
  • 14
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
    • Schmalzried TP, Kwong LM, Jasty M, et al. The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop Rel Res 1991; 274: 60.
    • (1991) Clin Orthop Rel Res , vol.274 , pp. 60
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 15
    • 0342527890 scopus 로고
    • Wear of polyethylene cups in THR: Analysis of 159 cups retrieved at revision surgery or autopsy
    • Jasty M, Bragdon CR, Lee KR, Hanson AE, Goetz DD. Wear of polyethylene cups in THR: Analysis of 159 cups retrieved at revision surgery or autopsy. Trans Orthop Res Soc 1993; 18: 291.
    • (1993) Trans Orthop Res Soc , vol.18 , pp. 291
    • Jasty, M.1    Bragdon, C.R.2    Lee, K.R.3    Hanson, A.E.4    Goetz, D.D.5
  • 16
    • 0342449164 scopus 로고
    • Chemical and morphological characterization of wear debris in failed uncemented total hip replacement
    • Shanbhag AS, Giant TT, Gilbert JL, Black J, Galante JO. Chemical and morphological characterization of wear debris in failed uncemented total hip replacement. Trans Orthop Res Soc 1993; 18: 296.
    • (1993) Trans Orthop Res Soc , vol.18 , pp. 296
    • Shanbhag, A.S.1    Giant, T.T.2    Gilbert, J.L.3    Black, J.4    Galante, J.O.5
  • 18
    • 0018431399 scopus 로고
    • Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prosthesis
    • Nusbaum HJ, Rose RM, Paul I, Grugnola, AM, Radin EL. Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prosthesis. J Appl Polym Sci 1979; 23: 777-789.
    • (1979) J Appl Polym Sci , vol.23 , pp. 777-789
    • Nusbaum, H.J.1    Rose, R.M.2    Paul, I.3    Grugnola, A.M.4    Radin, E.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.