1
-
-
0034142667
-
Wear simulation of UHMWPE for total hip replacement with multidirectional motion pin-on-disk device: Effects of the counter face material, contact area and lubrication
-
Saikko, V. and Ahlroos, T. Wear simulation of UHMWPE for total hip replacement with multidirectional motion pin-on-disk device: effects of the counter face material, contact area and lubrication. J. Blomed. Mater. Res., 2000, 49, 147-154.
-
(2000)
J. Blomed. Mater. Res.
, vol.49
, pp. 147-154
-
-
Saikko, V.1
Ahlroos, T.2
-
2
-
-
0030630960
-
Development of six-station knee wear simulator and preliminary wear results
-
Burgess, I. C., Kolar, M., Cunningham, J. L., and Unsworth, A. Development of six-station knee wear simulator and preliminary wear results. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1997, 211(H1), 37-47.
-
(1997)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.211
, Issue.H1
, pp. 37-47
-
-
Burgess, I.C.1
Kolar, M.2
Cunningham, J.L.3
Unsworth, A.4
-
3
-
-
33846292655
-
Kinematics and wear damage during stair descent loading in knee simulation
-
In Tampa, Florida
-
Harman, M. K., Benson, L. C., DesJardins, J. D., and LaBerge, M. Kinematics and wear damage during stair descent loading in knee simulation. In Transactions of the Society for Biomaterials, Tampa, Florida, 2002, p. 52.
-
(2002)
Transactions of the Society for Biomaterials
, pp. 52
-
-
Harman, M.K.1
Benson, L.C.2
DesJardins, J.D.3
LaBerge, M.4
-
4
-
-
1842613503
-
Knee joint loading patterns during activities of daily living in TKR patients
-
Benson, L C., LaBerge, M., and Pace, T. B. Knee joint loading patterns during activities of daily living in TKR patients. In Transactions of the American Society of Mechanical Engineers Bioengineering Division (BED) on Advances in Bioengineering, 2003, pp. 42955.
-
(2003)
Transactions of the American Society of Mechanical Engineers Bioengineering Division (BED) on Advances in Bioengineering
, pp. 42955
-
-
Benson, L.C.1
LaBerge, M.2
Pace, T.B.3
-
5
-
-
0042069555
-
The influences of lubricant and material on polymer/CoCr sliding friction
-
Yao, J. Q., Laurent, M. P., Johnson, T. S., Blanchard, C. R., and Crowninshield, R. D. The influences of lubricant and material on polymer/ CoCr sliding friction. Wear, 2003, 255, 780-784.
-
(2003)
Wear
, vol.255
, pp. 780-784
-
-
Yao, J.Q.1
Laurent, M.P.2
Johnson, T.S.3
Blanchard, C.R.4
Crowninshield, R.D.5
-
6
-
-
0032007946
-
The fallacy of evaluating biomaterial wear rates with water as lubricant: A hip simulator study of alumina-PTFE and CoCr-PTFE combinations
-
Wesley, P., Sherry, J., Victoria, G., and Clarke, I. C. The fallacy of evaluating biomaterial wear rates with water as lubricant: a hip simulator study of alumina-PTFE and CoCr-PTFE combinations. J. Biomed. Mater. Res., 1998, 39, 229-233.
-
(1998)
J. Biomed. Mater. Res.
, vol.39
, pp. 229-233
-
-
Wesley, P.1
Sherry, J.2
Victoria, G.3
Clarke, I.C.4
-
7
-
-
0041672492
-
Standard practice for reciprocating pin-on-flat evaluation of friction and wear properties of polymeric materials for use in total joint prostheses
-
ASTM-F732-38: In (American National Standards Institute)
-
ASTM-F732-38: Standard practice for reciprocating pin-on-flat evaluation of friction and wear properties of polymeric materials for use in total joint prostheses. In Annual book of ASTM standards, 1982, pp. 212-217 (American National Standards Institute).
-
(1982)
Annual Book of ASTM Standards
, pp. 212-217
-
-
-
8
-
-
0036434727
-
Rheology of the joint fluid in total knee arthroplasty patients
-
Mazzucco, D., McKinley, G., Scott, R., and Spector, M. Rheology of the joint fluid in total knee arthroplasty patients. J. Orthop. Res., 2002, 20, 1157-1163.
-
(2002)
J. Orthop. Res.
, vol.20
, pp. 1157-1163
-
-
Mazzucco, D.1
McKinley, G.2
Scott, R.3
Spector, M.4
-
9
-
-
33846275586
-
The role of SAPL as a boundary lubricant in prosthetic joints
-
(in press)
-
Gale, L. R., Coller, R., Hargreaves, D. J., Hills, B. A., and Crawford, R. The role of SAPL as a boundary lubricant in prosthetic joints. Tribology Int. (in press).
-
Tribology Int.
-
-
Gale, L.R.1
Coller, R.2
Hargreaves, D.J.3
Hills, B.A.4
Crawford, R.5
-
10
-
-
0032773373
-
Effect of protein lubrication on the wear properties of materials for prosthetic joints
-
Liao, Y. S., Benya, P D., and McKellop, H. A. Effect of protein lubrication on the wear properties of materials for prosthetic joints. J. Biomed. Mater. Res., 1999, 48, 465-473.
-
(1999)
J. Biomed. Mater. Res.
, vol.48
, pp. 465-473
-
-
Liao, Y.S.1
Benya, P.D.2
McKellop, H.A.3
-
11
-
-
0034438861
-
Boundary lubrication in vivo
-
Hills, B. A. Boundary lubrication in vivo. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2000, 214(H1), 83-94.
-
(2000)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.214
, Issue.H1
, pp. 83-94
-
-
Hills, B.A.1
-
12
-
-
0031171676
-
Phospholipids as boundary lubricants in wear tests of prosthetic joint materials
-
Saikko, V. and Ahlroos, T. Phospholipids as boundary lubricants in wear tests of prosthetic joint materials. Wear, 1997, 207, 86-91.
-
(1997)
Wear
, vol.207
, pp. 86-91
-
-
Saikko, V.1
Ahlroos, T.2
-
13
-
-
0036937210
-
Highly viscous sodium hyaluronate and joint lubrication
-
Mori, S., Naito, M., and Moriyama, S. Highly viscous sodium hyaluronate and joint lubrication. Int. Orthops, 2002, 26, 116-121.
-
(2002)
Int. Orthops
, vol.26
, pp. 116-121
-
-
Mori, S.1
Naito, M.2
Moriyama, S.3
-
14
-
-
0031171471
-
Increased friction of animal joints by experimental degeneration and the recovery by the addition of HA
-
Obara, T., Mabuchi, Iso T., and Yamaguchi, T. Increased friction of animal joints by experimental degeneration and the recovery by the addition of HA. Clin. Biomechanics, 1997, 12, 246-252.
-
(1997)
Clin. Biomechanics
, vol.12
, pp. 246-252
-
-
Obara, T.1
Mabuchi, I.T.2
Yamaguchi, T.3
-
15
-
-
0346725975
-
The effects of lubricant composition on in vitro wear testing of polymeric acetabular components
-
Wang, A., Essner, A., and Schmidig, G. The effects of lubricant composition on in vitro wear testing of polymeric acetabular components. J. Biomed. Mater. Res., 2004, 68B, 45-52.
-
(2004)
J. Biomed. Mater. Res.
, vol.68 B
, pp. 45-52
-
-
Wang, A.1
Essner, A.2
Schmidig, G.3
-
16
-
-
0001649318
-
Role of proteins and hyaluronic acid in the lubrication and wear of UHMWPE acetabular cups
-
Wang, A., Polineni, V. K., Essner, A., Stark C., and Dumbleton, J. H. Role of proteins and hyaluronic acid in the lubrication and wear of UHMWPE acetabular cups. In Transactions of the Society for Biomaterials, 1998, p. 218.
-
(1998)
Transactions of the Society for Biomaterials
, pp. 218
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
17
-
-
0034925520
-
Phospholipid composition of articular cartilage boundary lubricant
-
Sarma, A. V., Powell, G. L., and LaBerge, M. Phospholipid composition of articular cartilage boundary lubricant. J. Orthop. Res., 2001, 19, 671-676.
-
(2001)
J. Orthop. Res.
, vol.19
, pp. 671-676
-
-
Sarma, A.V.1
Powell, G.L.2
LaBerge, M.3
-
18
-
-
85012803379
-
Techniques of lipidology: Isolation, analysis and identification of lipids
-
In (North-Holland Publishing Company, Amsterdam, The Netherlands)
-
Kates, M. Techniques of lipidology: isolation, analysis and identification of lipids. In Laboratory techniques in biochemistry and molecular biology, 1972 (North-Holland Publishing Company, Amsterdam, The Netherlands).
-
(1972)
Laboratory Techniques in Biochemistry and Molecular Biology
-
-
Kates, M.1
-
19
-
-
0027416313
-
Hyaluronate in total hip replacement
-
Saari, H., Santavirta, S., Nordstorm, D., Paavolainen, P., and Konttinen, Y. Hyaluronate in total hip replacement. J. Rheumatology, 1993, 20, 87-90.
-
(1993)
J. Rheumatology
, vol.20
, pp. 87-90
-
-
Saari, H.1
Santavirta, S.2
Nordstorm, D.3
Paavolainen, P.4
Konttinen, Y.5
-
20
-
-
33747753864
-
Biotribological aspects of natural synovial joints and artificial joints
-
In (Springer-Verlag)
-
Murikami, T. Biotribological aspects of natural synovial joints and artificial joints. In Human biomechanics and injury prevention, 2000, pp. 236-242 (Springer-Verlag).
-
(2000)
Human Biomechanics and Injury Prevention
, pp. 236-242
-
-
Murikami, T.1
-
21
-
-
0027973774
-
Changes in joint fluid after total arthroplasty - A quantitative study on the rabbit knee-joint
-
Delecrin, J., Oka, M., Takahashi, S., Yamamuro, T., and Nakamura, T. Changes in joint fluid after total arthroplasty - a quantitative study on the rabbit knee-joint. Clin. Orthop. Related Res., 1994, 307, 240-249.
-
(1994)
Clin. Orthop. Related Res.
, vol.307
, pp. 240-249
-
-
Delecrin, J.1
Oka, M.2
Takahashi, S.3
Yamamuro, T.4
Nakamura, T.5
-
22
-
-
0033835666
-
Hyaluronan in synovial fluid of patients with loose total hip prosthesis. Comparison with hyaluronan in patients with hip osteoarthritis and idiopathic osteonecrosis of femoral head
-
Yamada, H., Morita, M., Henmi, O., Miyauchi, S., Yoshida, Y., Kikuchi, T., Terada, N., Washimi, O., Washimi, Y., and Seki, T. Hyaluronan in synovial fluid of patients with loose total hip prosthesis. Comparison with hyaluronan in patients with hip osteoarthritis and idiopathic osteonecrosis of femoral head. Arch. Orthop. Trauma Surg., 2000, 120, 521-524.
-
(2000)
Arch. Orthop. Trauma Surg.
, vol.120
, pp. 521-524
-
-
Yamada, H.1
Morita, M.2
Henmi, O.3
Miyauchi, S.4
Yoshida, Y.5
Kikuchi, T.6
Terada, N.7
Washimi, O.8
Washimi, Y.9
Seki, T.10
-
23
-
-
0034308356
-
The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
-
DesJardins, J. D., Walker, P. S., Haider, H., and Perry, J. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. J. Biomechanics, 2000, 33, 1231-1242.
-
(2000)
J. Biomechanics
, vol.33
, pp. 1231-1242
-
-
DesJardins, J.D.1
Walker, P.S.2
Haider, H.3
Perry, J.4
-
24
-
-
0034059304
-
Methodology for long-term wear testing of total knee replacements
-
Walker, P. S., Blunn, G. W., Perry, J. P., Bell, C. J., Sathasivam, S., Andriacchi, T. P., Paul, J. P., Haider, H., and Campbell, P. A. Methodology for long-term wear testing of total knee replacements. Clin. Orthop. Related Res., 2000, 372, 290-301.
-
(2000)
Clin. Orthop. Related Res.
, vol.372
, pp. 290-301
-
-
Walker, P.S.1
Blunn, G.W.2
Perry, J.P.3
Bell, C.J.4
Sathasivam, S.5
Andriacchi, T.P.6
Paul, J.P.7
Haider, H.8
Campbell, P.A.9
-
26
-
-
0012027552
-
On the 'real' input of prescribed force-control conditions in TKR simulation and wear testing
-
In Kamuela, Hawaii
-
Haider, H., Walker, P. S., Bell, C.J., and Blunn, G. W. On the 'real' input of prescribed force-control conditions in TKR simulation and wear testing. In Transations of the 6th World Biomaterials Congress, Kamuela, Hawaii, 2000, p. 862.
-
(2000)
Transations of the 6th World Biomaterials Congress
, pp. 862
-
-
Haider, H.1
Walker, P.S.2
Bell, C.J.3
Blunn, G.W.4
-
27
-
-
3943082588
-
Rates of diffusion of copper and zinc in alpha brass
-
Kirkendall, E., Thomassen, L., and Upthegrove C. Rates of diffusion of copper and zinc in alpha brass. Trans. Metallurg. Soc. AIME, 1939, 133, 186-203.
-
(1939)
Trans. Metallurg. Soc. AIME
, vol.133
, pp. 186-203
-
-
Kirkendall, E.1
Thomassen, L.2
Upthegrove, C.3
-
28
-
-
1542289493
-
-
(Academic Press, New York)
-
Lin Vien, D., Colthup, N. B., Fateley, W. G., and Grasselli, J. G. The handbook of infrared and Raman characteristic frequencies of organic molecules, 1991 (Academic Press, New York).
-
(1991)
The Handbook of Infrared and Raman Characteristic Frequencies of Organic Molecules
-
-
Lin Vien, D.1
Colthup, N.B.2
Fateley, W.G.3
Grasselli, J.G.4
-
29
-
-
0032052643
-
Oxidation in orthopedic UHMWPE sterilized by gamma-radiation and ethylene oxide
-
Costa, L., Luda, M.P., Trossarelli, L., Brach del Prever, E. M., Crova, M., and Gallinaro, P. Oxidation in orthopedic UHMWPE sterilized by gamma-radiation and ethylene oxide. Biomaterials, 1998, 19, 659-668.
-
(1998)
Biomaterials
, vol.19
, pp. 659-668
-
-
Costa, L.1
Luda, M.P.2
Trossarelli, L.3
Brach del Prever, E.M.4
Crova, M.5
Gallinaro, P.6
-
30
-
-
0027626396
-
Challenge to the concept that UHMWPE acetabular components oxidize in vivo
-
James, S. P., Blazka, S., and Merrill, E. W. Challenge to the concept that UHMWPE acetabular components oxidize in vivo. Biomaterials, 1993, 14, 643-647.
-
(1993)
Biomaterials
, vol.14
, pp. 643-647
-
-
James, S.P.1
Blazka, S.2
Merrill, E.W.3
-
31
-
-
0025549157
-
Caracterisation chimique, biochimique et dosage des metaux du liquide
-
Mangione, P., Chauveaux, D., Baquey, C., and Honton, L. L. Caracterisation chimique, biochimique et dosage des metaux du liquide . Int. Orthops, 2000, 14, 393-397.
-
(2000)
Int. Orthops
, vol.14
, pp. 393-397
-
-
Mangione, P.1
Chauveaux, D.2
Baquey, C.3
Honton, L.L.4
-
32
-
-
0032488266
-
Measurement of zeta potentials of particulate biomaterials in protein rich hyaluronan solutions with changes in pH and protein constituents
-
Kitano, T., Obashi, H., Kadoya, Y., Kobayashii, A., Yutani, Y., and Yamano, Y. Measurement of zeta potentials of particulate biomaterials in protein rich hyaluronan solutions with changes in pH and protein constituents. J. Biomed. Mater. Res., 1998, 42, 452-457.
-
(1998)
J. Biomed. Mater. Res.
, vol.42
, pp. 452-457
-
-
Kitano, T.1
Obashi, H.2
Kadoya, Y.3
Kobayashii, A.4
Yutani, Y.5
Yamano, Y.6
-
33
-
-
0026266892
-
Tribology of human and artificial joints
-
Unsworth, A. Tribology of human and artificial joints. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1991, 205(H3), 163-172.
-
(1991)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.205
, Issue.H3
, pp. 163-172
-
-
Unsworth, A.1
-
34
-
-
0020576705
-
The synovial like membrane at the cement bone interface in loose total hip replacements and its proposed role in bone lysis
-
Goldring, S. R., Schiller, A. L., and Roelke, M. The synovial like membrane at the cement bone interface in loose total hip replacements and its proposed role in bone lysis. J. Bone Jt Surg., 1983, 65A, 575-584.
-
(1983)
J. Bone Jt Surg.
, vol.65 A
, pp. 575-584
-
-
Goldring, S.R.1
Schiller, A.L.2
Roelke, M.3
-
35
-
-
0022510812
-
Formation of a synovial like membrane at the bone cement interface. Its role in bone resorption and implant loosening after total hip replacement
-
Goldring, S. R., Jasty, M., and Roelke, M. Formation of a synovial like membrane at the bone cement interface. Its role in bone resorption and implant loosening after total hip replacement. Arthritis and Rheumatism, 1986, 29, 836-842.
-
(1986)
Arthritis and Rheumatism
, vol.29
, pp. 836-842
-
-
Goldring, S.R.1
Jasty, M.2
Roelke, M.3
-
36
-
-
0012057858
-
Standard guide for gravimetric wear assessment of prosthetic knee designs in simulator devices
-
ASTM F1715-96: In (American National Standards Institute)
-
ASTM F1715-96: Standard guide for gravimetric wear assessment of prosthetic knee designs in simulator devices. In Annual book of ASTM standards, 1996 (American National Standards Institute).
-
(1996)
Annual Book of ASTM Standards
-
-
-
37
-
-
33846280254
-
Effect of bovine serum concentration on the lubrication of UHMWPE/CoCr alloy
-
In San Diego, California
-
Leroy-Gallisot, A., Chillag, K.J., and LaBerge, M. Effect of bovine serum concentration on the lubrication of UHMWPE/CoCr alloy. In Transactions of the Society for Biomaterials, San Diego, California, 1998, p. 219.
-
(1998)
Transactions of the Society for Biomaterials
, pp. 219
-
-
Leroy-Gallisot, A.1
Chillag, K.J.2
LaBerge, M.3
-
38
-
-
33846329911
-
Stability of bovine serum lubricant during prolonged knee joint simulator wear testing
-
In Kamuela, Hawaii, 15-20 May
-
DesJardins, J. D., Benson, L. C., and LaBerge, M. Stability of bovine serum lubricant during prolonged knee joint simulator wear testing. In Transactions of the 6th World Biomaterials Congress, Kamuela, Hawaii, 15-20 May 2000, p. 868.
-
(2000)
Transactions of the 6th World Biomaterials Congress
, pp. 868
-
-
DesJardins, J.D.1
Benson, L.C.2
LaBerge, M.3
-
39
-
-
0002465733
-
Effects of varying lubricant, frequency and motion in hip simulator wear study
-
In San Diego, California
-
Sauer, W. and Salchi, A. Effects of varying lubricant, frequency and motion in hip simulator wear study. In Transactions of the Society for Biomaterials. San Diego, California, 1998, p. 416.
-
(1998)
Transactions of the Society for Biomaterials
, pp. 416
-
-
Sauer, W.1
Salchi, A.2
-
40
-
-
71649101993
-
Synovial fluid from patients with prosthetic joint arthroplasty: Protein concentration and in vivo wear of polyethylene
-
In San Francisco, California, 9-13 February
-
Noordin, S., Schmalzried, T. P., Campbell, P., and Amstutz, H. C. Synovial fluid from patients with prosthetic joint arthroplasty: protein concentration and in vivo wear of polyethylene. In Transactions of the Orthopaedic Research Society, San Francisco, California, 9-13 February 1997, p. 769.
-
(1997)
Transactions of the Orthopaedic Research Society
, pp. 769
-
-
Noordin, S.1
Schmalzried, T.P.2
Campbell, P.3
Amstutz, H.C.4
-
41
-
-
0016148193
-
Role of hyaluronic acid in joint lubrication
-
Swann, D. A., Radin, E. L., Mazimiec, M., Weiser, P. A., Curran, N. Lewneck, G. Role of hyaluronic acid in joint lubrication. Ann. Rheumatic Diseases, 1974, 33, 318-326.
-
(1974)
Ann. Rheumatic Diseases
, vol.33
, pp. 318-326
-
-
Swann, D.A.1
Radin, E.L.2
Mazimiec, M.3
Weiser, P.A.4
Curran, N.5
Lewneck, G.6
-
42
-
-
0000865506
-
Bio-tribology of natural and replacement joints
-
In (Springer-Verlag, Berlin, Germany)
-
Dowson, D. Bio-tribology of natural and replacement joints. In Biomechanics of diarthrodial joints, 1990, pp. 306-345 (Springer-Verlag, Berlin, Germany).
-
(1990)
Biomechanics of Diarthrodial Joints
, pp. 306-345
-
-
Dowson, D.1
-
43
-
-
33846309754
-
A comparison of biological lubricants to bovine calf serum for total joint wear testing
-
In Dallas, Texas
-
Yao, J. Q., Laurent, M. P., Gilbertson, L. N., Blanchard, C. R., Crowninshield, R. D., and Jacobs, J. J. A comparison of biological lubricants to bovine calf serum for total joint wear testing. In Transactions of the Orthopaedic Research Society, Dallas, Texas, 2002, p. 1004.
-
(2002)
Transactions of the Orthopaedic Research Society
, pp. 1004
-
-
Yao, J.Q.1
Laurent, M.P.2
Gilbertson, L.N.3
Blanchard, C.R.4
Crowninshield, R.D.5
Jacobs, J.J.6
-
44
-
-
0035069544
-
Correlation of wear debris induced osteolysis and revision with volumetric wear rates of polyethylene
-
Oparaugo, P. C., Clarke, I. C., Malchau, H., and Herberts, P. Correlation of wear debris induced osteolysis and revision with volumetric wear rates of polyethylene. Acta Orthopaedica Scandinavica, 2001, 72, 22-28.
-
(2001)
Acta Orthopaedica Scandinavica
, vol.72
, pp. 22-28
-
-
Oparaugo, P.C.1
Clarke, I.C.2
Malchau, H.3
Herberts, P.4
-
45
-
-
0001084495
-
Wear debris in total joint replacements
-
Jacobs, J. J., Shanbag, A., Glant, T. T., Black, J., and Galante, J. O. Wear debris in total joint replacements. J. Am. Academy of Orthop. Surgeons, 1994, 2, 212-220.
-
(1994)
J. Am. Academy of Orthop. Surgeons
, vol.2
, pp. 212-220
-
-
Jacobs, J.J.1
Shanbag, A.2
Glant, T.T.3
Black, J.4
Galante, J.O.5
-
46
-
-
33846285504
-
Evaluation of the effect of articular surface material on a metal backed patellar component
-
Millano, M. T., Whiteside, L. A., Kaiser, A. D., and Zwirkoski, P. A. Evaluation of the effect of articular surface material on a metal backed patellar component. In Transactions of the Orthopaedic Research Society, 1990, p. 279.
-
(1990)
Transactions of the Orthopaedic Research Society
, pp. 279
-
-
Millano, M.T.1
Whiteside, L.A.2
Kaiser, A.D.3
Zwirkoski, P.A.4
-
47
-
-
0035869773
-
Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion
-
Koerten, H. K., Onderwater, J. J. M., Koerten, E. W. A., Bernoski, E.P., and Neliseen, R. G. Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion. J. Biomed. Mater. Res., 2001, 54, 591-596.
-
(2001)
J. Biomed. Mater. Res.
, vol.54
, pp. 591-596
-
-
Koerten, H.K.1
Onderwater, J.J.M.2
Koerten, E.W.A.3
Bernoski, E.P.4
Neliseen, R.G.5
-
48
-
-
0037328339
-
Effect of different metal ions on the oxidative damage and antioxidant capacity of hyaluronic acid
-
Balogh, G. T., Illes, J., Szekely, Z., Forrai, E., and Gere, A. Effect of different metal ions on the oxidative damage and antioxidant capacity of hyaluronic acid. Arch. Biochemistry and Biophysics, 2003, 410, 76-82.
-
(2003)
Arch. Biochemistry and Biophysics
, vol.410
, pp. 76-82
-
-
Balogh, G.T.1
Illes, J.2
Szekely, Z.3
Forrai, E.4
Gere, A.5
-
49
-
-
0031852744
-
Degradation of hyaluronic acid at the metal surface
-
Miyazaki, T., Yomota, C., and Okada, S. Degradation of hyaluronic acid at the metal surface. Colloid Polymer Sci., 1998, 276, 388-394.
-
(1998)
Colloid Polymer Sci.
, vol.276
, pp. 388-394
-
-
Miyazaki, T.1
Yomota, C.2
Okada, S.3
-
50
-
-
0031084281
-
Mechano-oxidative degradation
-
Costa, L., Luda, M. P., and Trossarelli, L. Mechano-oxidative degradation. Polymer Degradation Stability, 1997, 55, 329-338.
-
(1997)
Polymer Degradation Stability
, vol.55
, pp. 329-338
-
-
Costa, L.1
Luda, M.P.2
Trossarelli, L.3
-
51
-
-
0001738320
-
Gamma sterilization of UHMWPE articular implants: Analysis of the oxidation problem
-
Premnath, V., Harris, W. H., Jasty, M., and Merrill, E. W. Gamma sterilization of UHMWPE articular implants: analysis of the oxidation problem. Biomaterials, 1996, 17, 1741-1753.
-
(1996)
Biomaterials
, vol.17
, pp. 1741-1753
-
-
Premnath, V.1
Harris, W.H.2
Jasty, M.3
Merrill, E.W.4
-
52
-
-
0035864330
-
Analysis of products diffused into UHMWPE prosthetic components in vivo
-
Costa, L., Bracco, P., Brach del Prever, E., Luda, M. P, and Trossarelli, L. Analysis of products diffused into UHMWPE prosthetic components in vivo. Biomaterials, 2001, 22, 307-315.
-
(2001)
Biomaterials
, vol.22
, pp. 307-315
-
-
Costa, L.1
Bracco, P.2
Brach del Prever, E.3
Luda, M.P.4
Trossarelli, L.5
|