Volumn 33, Issue 4, 1996, Pages 275-283

Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model

Author keywords

[No Author keywords available]

Indexed keywords

COBALT ALLOYS; IMPLANTS (SURGICAL); JOINTS (ANATOMY); LUBRICANTS; LUBRICATION; POLYTETRAFLUOROETHYLENES; WATER; WEAR OF MATERIALS;

EID: 0030560772     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199624)33:4<275::AID-JBM7>3.0.CO;2-M     Document Type: Article
Times cited : (38)

References (22)
  • 1
    • 10544253608 scopus 로고    scopus 로고
    • Wear simulator data for ceramic/PE: Is there valid data to support clinical usage in USA?
    • Willert, H.; Buchhorn, G., eds. Germany: Gottingen University
    • Clarke, I. C.; Gustafson, A. Wear simulator data for ceramic/PE: is there valid data to support clinical usage in USA? Willert, H.; Buchhorn, G., eds. 6th Biomater. Symp. Implant Mater. Orthop. Surg. Germany: Gottingen University; 1996.
    • (1996) 6th Biomater. Symp. Implant Mater. Orthop. Surg.
    • Clarke, I.C.1    Gustafson, A.2
  • 2
    • 0017513553 scopus 로고
    • New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminum oxide ceramic/metal
    • Semlitsch, M.; Lehmann, M.; Weber, H. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminum oxide ceramic/metal. J. Biomed. Mater. Res. 11:537-552; 1977.
    • (1977) J. Biomed. Mater. Res. , vol.11 , pp. 537-552
    • Semlitsch, M.1    Lehmann, M.2    Weber, H.3
  • 3
    • 0027437359 scopus 로고
    • Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator
    • Saikko, V. O.; Paavolainen, P. O.; Slatis, P. Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator. Acta Orthop. Scand. 64:391-402; 1993.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 391-402
    • Saikko, V.O.1    Paavolainen, P.O.2    Slatis, P.3
  • 4
    • 0028439173 scopus 로고
    • Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints
    • Derbyshire, B.; Fisher, J.; Dowson, D.; Hardaker, C.; Brummitt, K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med. Eng. Phys. 16:229-236; 1994.
    • (1994) Med. Eng. Phys. , vol.16 , pp. 229-236
    • Derbyshire, B.1    Fisher, J.2    Dowson, D.3    Hardaker, C.4    Brummitt, K.5
  • 5
    • 0029027097 scopus 로고
    • Titanium nitride ceramic film against polyethylene, a 48 million cycle wear test
    • Pappas, M. J.; Makris, G.; Buechel, F. F. Titanium nitride ceramic film against polyethylene, a 48 million cycle wear test. Clin. Orthop. Rel. Res. 317:64-70; 1995.
    • (1995) Clin. Orthop. Rel. Res. , vol.317 , pp. 64-70
    • Pappas, M.J.1    Makris, G.2    Buechel, F.F.3
  • 6
    • 0002836874 scopus 로고
    • The use of hip joint simulators for the evaluation of wear of total hip prostheses
    • Wright, K. W. J.; Scales, J. T. The use of hip joint simulators for the evaluation of wear of total hip prostheses. Eval. Biomater. 135-146; 1980.
    • (1980) Eval. Biomater. , pp. 135-146
    • Wright, K.W.J.1    Scales, J.T.2
  • 7
    • 10544224318 scopus 로고    scopus 로고
    • Laboratory confirmation of least ceramic-polyethylene wear-debris with Charnley-size femoral heads
    • Clarke, I. C.; Gustafson, A.; Jung, H.; Fujisawa, A. Laboratory confirmation of least ceramic-polyethylene wear-debris with Charnley-size femoral heads. Acta Orthop. Scand. 1996.
    • (1996) Acta Orthop. Scand.
    • Clarke, I.C.1    Gustafson, A.2    Jung, H.3    Fujisawa, A.4
  • 8
    • 0003096768 scopus 로고
    • Effect of ball material, diameter and surface roughness on the wear of polyethylene acetabular cups
    • San Francisco, March 18-22
    • McKellop, H.; Ebramzadeh, E.; Lu, B.; Sarmiento, A. Effect of ball material, diameter and surface roughness on the wear of polyethylene acetabular cups. Presented at the 21st Annu. Mtg. Soc. Biomater., San Francisco, March 18-22, 1995.
    • (1995) 21st Annu. Mtg. Soc. Biomater.
    • McKellop, H.1    Ebramzadeh, E.2    Lu, B.3    Sarmiento, A.4
  • 9
    • 1542482995 scopus 로고
    • Influence of ball diameter on polyethylene wear rates
    • San Francisco: Society for Biomaterials
    • Clarke, I. C.; Fujisawa, A.; Jung, H. Influence of ball diameter on polyethylene wear rates. Proc. Mtg. 19th Annu. Soc. Biomater. San Francisco: Society for Biomaterials; 1993:57.
    • (1993) Proc. Mtg. 19th Annu. Soc. Biomater , pp. 57
    • Clarke, I.C.1    Fujisawa, A.2    Jung, H.3
  • 11
    • 0014457406 scopus 로고
    • The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip
    • Charnley, J.; Kamanger, A.; Longfield, M. D. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med. Biol. Eng. 7:31-39; 1969.
    • (1969) Med. Biol. Eng. , vol.7 , pp. 31-39
    • Charnley, J.1    Kamanger, A.2    Longfield, M.D.3
  • 12
    • 1542797739 scopus 로고
    • Wear of HDP socket on total hip prostheses with ceramic head
    • Shimazu, A. ed.
    • Mikami, H. Wear of HDP socket on total hip prostheses with ceramic head. Shimazu, A. ed. Orthopaedic Biomechanics. 1980:60.
    • (1980) Orthopaedic Biomechanics , pp. 60
    • Mikami, H.1
  • 13
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore, J.; Morrey, B. Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone Joint Surg. 72A:518-528; 1990.
    • (1990) J. Bone Joint Surg. , vol.72 A , pp. 518-528
    • Livermore, J.1    Morrey, B.2
  • 14
    • 84921077381 scopus 로고
    • Wear of plastics materials in the hip joint
    • University of Strathclyde, Glasgow, Scotland
    • Charnley, J. Wear of plastics materials in the hip joint. Conference on Plastics in Medicine and Surgery. University of Strathclyde, Glasgow, Scotland; 1975:3.1-3.10.
    • (1975) Conference on Plastics in Medicine and Surgery , pp. 31-310
    • Charnley, J.1
  • 15
    • 0346840501 scopus 로고
    • Wear, retrieval and simulators for artificial joints
    • March/April
    • Unsworth, A. Wear, retrieval and simulators for artificial joints. Orthop. Prod. News March/April; 1995.
    • (1995) Orthop. Prod. News
    • Unsworth, A.1
  • 16
    • 0018034893 scopus 로고
    • Wear characteristics of UHMW polyethylene: A method for accurately measuring extremely low wear rates
    • McKellop, H.; Clarke, I. C.; Markolf, K. L.; Amstutz, H. C. Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates. J. Biomed. Mater. Res. 12:895-927; 1978.
    • (1978) J. Biomed. Mater. Res. , vol.12 , pp. 895-927
    • McKellop, H.1    Clarke, I.C.2    Markolf, K.L.3    Amstutz, H.C.4
  • 17
    • 0002591099 scopus 로고
    • Evolution and evaluation of materials - Screening machines and joint simulators in predicting in-vivo wear phenomena
    • Ducheyne, P.; Hastings, G. W. eds. Boca Raton, FL: CRC Press
    • McKellop, H. A.; Clarke, I. C. Evolution and evaluation of materials - screening machines and joint simulators in predicting in-vivo wear phenomena. Ducheyne, P.; Hastings, G. W. eds. Functional Behavior of Orthopedic Biomaterials, Vol. 2. Boca Raton, FL: CRC Press; 1983.
    • (1983) Functional Behavior of Orthopedic Biomaterials , vol.2
    • McKellop, H.A.1    Clarke, I.C.2
  • 18
    • 0029616092 scopus 로고
    • Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator
    • Saikko, V. Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator. Acta Orthop. Scand. 66:501-506; 1995.
    • (1995) Acta Orthop. Scand. , vol.66 , pp. 501-506
    • Saikko, V.1
  • 19
    • 0000398086 scopus 로고
    • Friction lubrication and wear of cobalt-chromium, alumina and zirconia hip prostheses compared on a joint simulator
    • McKellop, H.; Lu, B.; Benya, P. Friction lubrication and wear of cobalt-chromium, alumina and zirconia hip prostheses compared on a joint simulator. Trans. 38th Annu. Orthop. Res. Soc. Mtg. 1992:402.
    • (1992) Trans. 38th Annu. Orthop. Res. Soc. Mtg. , pp. 402
    • McKellop, H.1    Lu, B.2    Benya, P.3
  • 20
    • 10544241344 scopus 로고
    • Hip simulator wear testing of isostatically molded UHMWPE
    • USA, Japan, Canada, Europe, San Diego
    • Shroeder, D. W. Hip simulator wear testing of isostatically molded UHMWPE. Trans. 2nd Combined Orthop. Res. Soc. Mtg. USA, Japan, Canada, Europe, San Diego; 1995:178.
    • (1995) Trans. 2nd Combined Orthop. Res. Soc. Mtg. , pp. 178
    • Shroeder, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.