메뉴 건너뛰기




Volumn 9, Issue 1, 2007, Pages 68-74

Noninvasive continuous glucose monitoring using photoacoustic technology - Results from the first 62 subjects

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTICS; ADULT; ARTICLE; BLOOD GLUCOSE MONITORING; DIABETES CONTROL; DIABETES MELLITUS; GLUCOSE BLOOD LEVEL; GLUCOSE INFUSION; HUMAN; INSULIN DEPENDENT DIABETES MELLITUS; MAJOR CLINICAL STUDY; NON INSULIN DEPENDENT DIABETES MELLITUS; NON INVASIVE MEASUREMENT; ORAL GLUCOSE TOLERANCE TEST; PATIENT COMPLIANCE; PHOTOACOUSTICS; PRIORITY JOURNAL;

EID: 33847225922     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2006.0059     Document Type: Article
Times cited : (84)

References (10)
  • 1
    • 29144453326 scopus 로고    scopus 로고
    • Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study Research Group: Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
    • Nathan DM, Cleary PA, Backlund JY, Genuth SM, Lachin JM, Orchard TJ, Raskin P, Zinman B; Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study Research Group: Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med 2005;353:2643-2653.
    • (2005) N Engl J Med , vol.353 , pp. 2643-2653
    • Nathan, D.M.1    Cleary, P.A.2    Backlund, J.Y.3    Genuth, S.M.4    Lachin, J.M.5    Orchard, T.J.6    Raskin, P.7    Zinman, B.8
  • 2
    • 0034628425 scopus 로고    scopus 로고
    • Retinopathy and nephropathy in patients with type 1 diabetes four years after a trial of intensive therapy. The Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group. N Engl J Med 2000;342:381-389. Erratum in: N Engl J Med 2000;342:1376.
    • Retinopathy and nephropathy in patients with type 1 diabetes four years after a trial of intensive therapy. The Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group. N Engl J Med 2000;342:381-389. Erratum in: N Engl J Med 2000;342:1376.
  • 3
    • 20944445475 scopus 로고    scopus 로고
    • Disease management in the young diabetic patient: Glucose monitoring, coping skills, and treatment strategies
    • Weinzimer SA, Doyle EA, Tamborlane WV Jr: Disease management in the young diabetic patient: glucose monitoring, coping skills, and treatment strategies. Clin Pediatr 2005;44:393-403.
    • (2005) Clin Pediatr , vol.44 , pp. 393-403
    • Weinzimer, S.A.1    Doyle, E.A.2    Tamborlane Jr, W.V.3
  • 4
    • 26844577646 scopus 로고    scopus 로고
    • Strategies for improving glycemic control: Effective use of glucose monitoring
    • Davidson J: Strategies for improving glycemic control: effective use of glucose monitoring. Am J Med 2005;118(Suppl 9A):27S-32S.
    • (2005) Am J Med , vol.118 , Issue.SUPPL. 9A
    • Davidson, J.1
  • 5
    • 11144256242 scopus 로고    scopus 로고
    • The relationship of postprandial glucose to HbA1c
    • Landgraf R: The relationship of postprandial glucose to HbA1c. Diabetes Metab Res Rev 2004;20(Suppl 2):S9-S12.
    • (2004) Diabetes Metab Res Rev , vol.20 , Issue.SUPPL. 2
    • Landgraf, R.1
  • 6
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005;28:1231-1239.
    • (2005) Diabetes Care , vol.28 , pp. 1231-1239
    • Klonoff, D.C.1
  • 7
    • 1642452596 scopus 로고    scopus 로고
    • Closed-loop insulin delivery-the path to physiological glucose control
    • Steil GM, Panteleon AE, Rebrin K: Closed-loop insulin delivery-the path to physiological glucose control. Adv Drug Deliv Rev 2004;56:125-144.
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3
  • 9
    • 33847200928 scopus 로고    scopus 로고
    • Nagar R, Pesach B, Ben-Ami U, inventors; Glucon Inc, assignee: Photoacoustic assay and imaging system. US Patent 6,846,288. January 25, 2005
    • Nagar R, Pesach B, Ben-Ami U, inventors; Glucon Inc., assignee: Photoacoustic assay and imaging system. US Patent 6,846,288. January 25, 2005.
  • 10
    • 0242332246 scopus 로고    scopus 로고
    • Glucose sensors and the alternate site testing-like phenomenon: Relationship between rapid blood glucose changes and glucose sensor signals
    • Koschinsky T, Jungheim K, Heinemann L: Glucose sensors and the alternate site testing-like phenomenon: relationship between rapid blood glucose changes and glucose sensor signals. Diabetes Technol Ther 2003;5:829-842.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 829-842
    • Koschinsky, T.1    Jungheim, K.2    Heinemann, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.