메뉴 건너뛰기




Volumn 60, Issue 1, 2012, Pages 149-157

Fast multiharmonic active load-pull system with waveform measurement capabilities

Author keywords

Active load pull; equalizer; large signal network analyzer (LSNA); microwave measurements; microwave power field effect transistors (FETs)

Indexed keywords

CURRENT WAVEFORMS; DEVICE UNDER TEST; DYNAMIC RANGE; HIGH FREQUENCY OPERATION; HIGH-POWER; HIGHER ORDER HARMONICS; INPUT POWER; LARGE-SIGNALS; LOAD IMPEDANCE; LOAD-PULL; MEASUREMENT SYSTEM; MEASUREMENT TIME; MULTIHARMONIC; NUMBER OF ITERATIONS; ON-WAFER; OPEN LOOPS; SIMULTANEOUS OPTIMIZATION; TIME INSTANCES; WAVEFORM MEASUREMENT; WIDE-BAND;

EID: 84855467779     PISSN: 00189480     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMTT.2011.2170090     Document Type: Article
Times cited : (31)

References (23)
  • 1
    • 0016316146 scopus 로고
    • Automatic load contour mapping for microwave power transistors
    • Dec.
    • J. Cusack, S. Perlow, and B. Perlman, "Automatic load contour mapping for microwave power transistors," IEEE Trans. Microw. Theory Tech., vol. MTT-22, no. 12, pp. 1146-1152, Dec. 1974.
    • (1974) IEEE Trans. Microw. Theory Tech. , vol.MTT-22 , Issue.12 , pp. 1146-1152
    • Cusack, J.1    Perlow, S.2    Perlman, B.3
  • 2
    • 85024343374 scopus 로고
    • A new load-pull characterization method for microwave power transistors
    • Jun.
    • Y. Takayama, "A new load-pull characterization method for microwave power transistors," in IEEE MTT-S Int. Microw. Symp. Dig., Jun. 1976, pp. 218-220.
    • (1976) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 218-220
    • Takayama, Y.1
  • 4
    • 84855425744 scopus 로고    scopus 로고
    • Cascading tuners for high-VSWR and harmonic load pull
    • Ontario, CA, Appl. Notes, Jan.
    • S. Dudkiewicz and R. Meierer, "Cascading tuners for high-VSWR and harmonic load pull." Maury Microwave, Ontario, CA, Appl. Notes, Jan. 2009, vol. 30, pp. 1-11.
    • (2009) Maury Microwave , vol.30 , pp. 1-11
    • Dudkiewicz, S.1    Meierer, R.2
  • 5
    • 84855464666 scopus 로고    scopus 로고
    • Importance of 2nd harmonic tuning for power amplifier design
    • Dec.
    • G. Simpson and M. Vassar, "Importance of 2nd harmonic tuning for power amplifier design," in 48th Automat. RF Tech. Group Conf. Dig., Dec. 1996, vol. 30, pp. 1-6.
    • (1996) 48th Automat. RF Tech. Group Conf. Dig. , vol.30 , pp. 1-6
    • Simpson, G.1    Vassar, M.2
  • 7
    • 0029210462 scopus 로고
    • A novel computerized multiharmonic active load-pull system for the optimization of high efficiency operating classes in power transistors
    • May
    • F. Blache, J. Nebus, P. Bouysse, and J. Villotte, "A novel computerized multiharmonic active load-pull system for the optimization of high efficiency operating classes in power transistors," in IEEE MTT-S Int. Microw. Symp. Dig., May 1995, pp. 1037-1040.
    • (1995) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 1037-1040
    • Blache, F.1    Nebus, J.2    Bouysse, P.3    Villotte, J.4
  • 8
    • 77949540143 scopus 로고    scopus 로고
    • An accurate calibrate-able multiharmonic active load-pull system based on the envelope load-pull concept
    • Mar.
    • M. S. Hashmi, A. L. Clarke, S. P. Woodington, J. Lees, J. Benedikt, and P. J. Tasker, "An accurate calibrate-able multiharmonic active load-pull system based on the envelope load-pull concept," IEEE Trans. Microw. Theory Tech., vol. 58, no. 3, pp. 656-664, Mar. 2010.
    • (2010) IEEE Trans. Microw. Theory Tech. , vol.58 , Issue.3 , pp. 656-664
    • Hashmi, M.S.1    Clarke, A.L.2    Woodington, S.P.3    Lees, J.4    Benedikt, J.5    Tasker, P.J.6
  • 9
    • 34748826202 scopus 로고    scopus 로고
    • New ultra-fast real-time active load-pull measurements for high speed RF power amplifier design
    • DOI 10.1109/MWSYM.2007.380536, 4264123, 2007 IEEE MTT-S International Microwave Symposium Digest
    • P. Roblin, S. J. Doo, X. Cui, G. Jessen, D. Chaillot, and J. Strahler, "New ultra-fast real-time active load-pull measurements for high speed RF power amplifier design," in IEEE MTT-S Int. Microw. Symp. Dig., Jun. 2007, pp. 1493-1496. (Pubitemid 47486281)
    • (2007) IEEE MTT-S International Microwave Symposium Digest , pp. 1493-1496
    • Roblin, P.1    Doo, S.J.2    Cui, X.3    Jessen, G.H.4    Chaillot, D.5    Strahler, J.6
  • 10
    • 54949085734 scopus 로고    scopus 로고
    • Recent advances in real-time load-pull systems
    • Nov.
    • V. Teppati, A. Ferrero, and U. Pisani, "Recent advances in real-time load-pull systems," IEEE Trans. Instrum. Meas., vol. 57, no. 11, pp. 2640-2646, Nov. 2008.
    • (2008) IEEE Trans. Instrum. Meas. , vol.57 , Issue.11 , pp. 2640-2646
    • Teppati, V.1    Ferrero, A.2    Pisani, U.3
  • 11
    • 77949969562 scopus 로고    scopus 로고
    • Characterization setup for device level dynamic load modulation measurements
    • Jun.
    • M. Thorsell, K. Andersson, and C. Fager, "Characterization setup for device level dynamic load modulation measurements," in IEEE MTT-S Int. Microw. Symp. Dig., Jun. 2009, pp. 1197-1200.
    • (2009) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 1197-1200
    • Thorsell, M.1    Andersson, K.2    Fager, C.3
  • 12
    • 71249083579 scopus 로고    scopus 로고
    • A mixed-signal approach for high-speed fully controlled multidimensional load-pull parameters sweep
    • Jun.
    • M. Squillante, M. Marchetti, M. Spirito, and L. de Vreede, "A mixed-signal approach for high-speed fully controlled multidimensional load-pull parameters sweep," in 73rd Automat. RF Tech. Group Conf. Dig., Jun. 2009, pp. 1-5.
    • (2009) 73rd Automat. RF Tech. Group Conf. Dig. , pp. 1-5
    • Squillante, M.1    Marchetti, M.2    Spirito, M.3    De Vreede, L.4
  • 13
    • 31344474246 scopus 로고    scopus 로고
    • Large-signal network analysis
    • Dec.
    • J. Verspecht, "Large-signal network analysis," IEEE Microw. Mag., vol. 6, no. 4, pp. 82-92, Dec. 2005.
    • (2005) IEEE Microw. Mag. , vol.6 , Issue.4 , pp. 82-92
    • Verspecht, J.1
  • 15
    • 84954163323 scopus 로고    scopus 로고
    • Comparison of calibrated S-parameters measured under CW and pulsed RF excitation with a non-linear vectorial network analyzer
    • Jun.
    • P. Vael and Y. Rolain, "Comparison of calibrated S-parameters measured under CW and pulsed RF excitation with a non-linear vectorial network analyzer," in 55th Automat. RF Tech. Group Conf. Dig., Jun. 2000, vol. 37, pp. 1-10.
    • (2000) 55th Automat. RF Tech. Group Conf. Dig. , vol.37 , pp. 1-10
    • Vael, P.1    Rolain, Y.2
  • 17
    • 77957808050 scopus 로고    scopus 로고
    • A novel methodology for fast harmonic-load control with a passive tuner and an active loop
    • May
    • S. Bonino, V. Teppati, and A. Ferrero, "A novel methodology for fast harmonic-load control with a passive tuner and an active loop," in IEEE MTT-S Int. Microw. Symp. Dig., May 2010, pp. 1158-1161.
    • (2010) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 1158-1161
    • Bonino, S.1    Teppati, V.2    Ferrero, A.3
  • 18
    • 77957819303 scopus 로고    scopus 로고
    • Active simultaneous harmonic source and load pull assisted by local polyharmonic distortion models
    • May
    • R. E. Leoni, A. Scott, and D. G. Ries, "Active simultaneous harmonic source and load pull assisted by local polyharmonic distortion models," in IEEE MTT-S Int. Microw. Symp. Dig., May 2010, pp. 1166-1169.
    • (2010) IEEE MTT-S Int. Microw. Symp. Dig. , pp. 1166-1169
    • Leoni, R.E.1    Scott, A.2    Ries, D.G.3
  • 20
    • 0029211394 scopus 로고
    • A PC controlled fully automatic active load-pull measurement system using a pseudo-gradient algorithm
    • Apr.
    • P. Poire, D.-L Le, and F. Ghannouchi, "A PC controlled fully automatic active load-pull measurement system using a pseudo-gradient algorithm," in IEEE Instrum. Meas. Tech. Conf, Apr. 1995, pp. 628-631.
    • (1995) IEEE Instrum. Meas. Tech. Conf , pp. 628-631
    • Poire, P.1    Le, D.-L.2    Ghannouchi, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.