-
1
-
-
0034526505
-
Environmental and biological monitoring of benzene during self-service automobile refueling
-
Egeghy, P. P.; Tornero-Velez, R.; Rappaport, S. M. Environmental and biological monitoring of benzene during self-service automobile refueling Environ. Health Perspect. 2000, 108 (12) 1195-1202 (Pubitemid 32049106)
-
(2000)
Environmental Health Perspectives
, vol.108
, Issue.12
, pp. 1195-1202
-
-
Egeghy, P.P.1
Tornero-Velez, R.2
Rappaport, S.M.3
-
2
-
-
0842348271
-
Personal volatile organic compound (VOC) exposure of children attending elementary schools adjacent to industrial complex
-
DOI 10.1016/j.atmosenv.2003.11.032
-
Park, K.; Jo, W. Personal volatile organic compound (VOC) exposure of children attending elementary schools adjacent to industrial complex Atmos. Environ. 2004, 38, 1303-1312 (Pubitemid 38177406)
-
(2004)
Atmospheric Environment
, vol.38
, Issue.9
, pp. 1303-1312
-
-
Park, K.-H.1
Jo, W.-K.2
-
3
-
-
47849100976
-
Seasonal variations in the household exposures of Korean housewives to volatile tap water disinfection by-products
-
Kim, H. Seasonal variations in the household exposures of Korean housewives to volatile tap water disinfection by-products Sci. Total Environ. 2008, 403, 59-67
-
(2008)
Sci. Total Environ.
, vol.403
, pp. 59-67
-
-
Kim, H.1
-
4
-
-
0015131404
-
Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography
-
Pauling, L.; Robinson, A. B.; Teranishi, R.; Cary, P. Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography Proc. Natl. Acad. Sci., U. S. A. 1971, 68 (10) 2374-2376
-
(1971)
Proc. Natl. Acad. Sci., U. S. A.
, vol.68
, Issue.10
, pp. 2374-2376
-
-
Pauling, L.1
Robinson, A.B.2
Teranishi, R.3
Cary, P.4
-
5
-
-
0344303513
-
Benzene and naphthalene in air and breath as indicators of exposure to jet fuel
-
DOI 10.1136/oem.60.12.969
-
Egeghy, P. P.; Hauf-Cabalo, L.; Gibson, R.; Rappaport, S. M. Benzene and naphthalene in air and breath as indicators of exposure to jet fuel Occup. Environ. Med. 2003, 60, 969-976 (Pubitemid 37494586)
-
(2003)
Occupational and Environmental Medicine
, vol.60
, Issue.12
, pp. 969-976
-
-
Egeghy, P.P.1
Hauf-Cabalo, L.2
Gibson, R.3
Rappaport, S.M.4
-
6
-
-
2142705861
-
A Field Method for Sampling Toluene in End-Exhaled Air, as a Biomarker of Occupational Exposure: Correlation with Other Exposure Indices
-
Ghittori, S.; Alessio, A.; Negri, S.; Maestri, L.; Zadra, P.; Imbriani, M. A field method for sampling toluene in end-exhaled air, as a biomarker of occupational exposure: Correlation with other exposure indices Ind. Health 2004, 42, 226-234 (Pubitemid 38543919)
-
(2004)
Industrial Health
, vol.42
, Issue.2
, pp. 226-234
-
-
Ghittori, S.1
Alessio, A.2
Negri, S.3
Maestri, L.4
Zadra, P.5
Imbriani, M.6
-
7
-
-
0035989567
-
Relationship between environmental exposure to toluene, xylene and ethylbenzene and the expired breath concentrations for gasoline service workers
-
DOI 10.1039/b203754h
-
Chen, M.; Chen, S.; Guo, B.; Mao, I. Relationship between environmental exposure to toluene, xylene and ethylbenzene and the expired breath concentrations for gasoline service workers J. Environ. Monit. 2002, 4, 562-566 (Pubitemid 34864588)
-
(2002)
Journal of Environmental Monitoring
, vol.4
, Issue.4
, pp. 562-566
-
-
Chen, M.-L.1
Chen, S.-H.2
Guo, B.-R.3
Mao, I.-F.4
-
8
-
-
0018191551
-
Evaluation of occupational exposure to xylene by blood, exhaled air and urine analysis
-
Engstrom, K.; Husman, K.; Pfaffli, P.; Riihim, V. Evolution of occupational exposure to xylene by blood, exhaled air and urine analysis Scand. J. Work, Environ. Health 1978, 4, 114-121 (Pubitemid 8378716)
-
(1978)
Scandinavian Journal of Work, Environment and Health
, vol.4
, Issue.2
, pp. 114-121
-
-
Engstrom, K.1
Husman, K.2
Pfaffli, P.3
Riihimaki, V.4
-
9
-
-
0026018214
-
Biological monitoring of occupational exposure to methyl ethyl ketone
-
Ong, C. N.; Sia, G. L.; Ong, H. Y.; Phoon, W. H.; Tan, K. T. Biological monitoring of occupational exposure to methyl ethyl ketone Int. Arch. Occup. Environ. Health 1991, 63, 319-324
-
(1991)
Int. Arch. Occup. Environ. Health
, vol.63
, pp. 319-324
-
-
Ong, C.N.1
Sia, G.L.2
Ong, H.Y.3
Phoon, W.H.4
Tan, K.T.5
-
10
-
-
0035900989
-
Occupational exposure to trihalomethanes in indoor swimming pools
-
Fantuzzi, G.; Righi, E.; Predieri, G.; Ceppelli, G.; Gobba, F.; Aggazzotti, G. Occupational exposure to trihalomethanes in indoor swimming pools Sci. Total Environ. 2001, 264, 257-265
-
(2001)
Sci. Total Environ.
, vol.264
, pp. 257-265
-
-
Fantuzzi, G.1
Righi, E.2
Predieri, G.3
Ceppelli, G.4
Gobba, F.5
Aggazzotti, G.6
-
11
-
-
72449164474
-
Quantitative breath analysis of volatile organic compounds of lung cancer patients
-
Song, G.; Qin, T.; Liu, H.; Xu, G.-B.; Pan, Y.-Y.; Xiong, F.-X.; Gu, K.-S.; Sun, G.-P.; Chen, Z.-D. Quantitative breath analysis of volatile organic compounds of lung cancer patients Lung Cancer 2010, 67 (2) 227-231
-
(2010)
Lung Cancer
, vol.67
, Issue.2
, pp. 227-231
-
-
Song, G.1
Qin, T.2
Liu, H.3
Xu, G.-B.4
Pan, Y.-Y.5
Xiong, F.-X.6
Gu, K.-S.7
Sun, G.-P.8
Chen, Z.-D.9
-
12
-
-
4544255985
-
Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
-
DOI 10.1016/j.jchromb.2004.08.013, PII S1570023204006579
-
Deng, C.; Zhang, J.; Yu, X.; Zhang, W.; Zhang, X. Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2004, 810 (2) 269-275 (Pubitemid 39243314)
-
(2004)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
, vol.810
, Issue.2
, pp. 269-275
-
-
Deng, C.1
Zhang, J.2
Yu, X.3
Zhang, W.4
Zhang, X.5
-
13
-
-
55049123025
-
GC-MS analysis of breath odor compounds in liver patients
-
Van den Velde, S.; Nevens, F.; Van hee, P.; van Steenberghe, D.; Quirynen, M. GC-MS analysis of breath odor compounds in liver patients J. Chromatog., B: Anal. Technol. Biomed. Life Sci. 2008, 875 (2) 344-348
-
(2008)
J. Chromatog., B: Anal. Technol. Biomed. Life Sci.
, vol.875
, Issue.2
, pp. 344-348
-
-
Van Den Velde, S.1
Nevens, F.2
Van Hee, P.3
Van Steenberghe, D.4
Quirynen, M.5
-
14
-
-
33749016240
-
Current status of clinical breath analysis
-
DOI 10.1007/s00340-006-2280-4, Optics: Trends in Laser Sources, Spectroscopic Techniques and their Applications to Trace Gas-Detection
-
Risby, T. H.; Solga, S. F. Current status of clinical breath analysis Appl. Phys. 2006, 85, 421-426 (Pubitemid 44451363)
-
(2006)
Applied Physics B: Lasers and Optics
, vol.85
, Issue.2-3
, pp. 421-426
-
-
Risby, T.H.1
Solga, S.F.2
-
15
-
-
0034653790
-
Breath alkanes as a marker of oxidative stress in different clinical conditions
-
DOI 10.1016/S0891-5849(00)00189-1, PII S0891584900001891
-
Aghdassi, E.; Allard, J. P. Breath alkanes as a marker of oxidative stress in different clinical conditions Free Radical Biol. Med. 2000, 28 (6) 880-886 (Pubitemid 30235160)
-
(2000)
Free Radical Biology and Medicine
, vol.28
, Issue.6
, pp. 880-886
-
-
Aghdassi, E.1
Allard, J.P.2
-
16
-
-
0028103871
-
Pentane and isoprene in expired air from humans: Gas-chromatographic analysis of single breath
-
Mendis, S.; Sobotka, P. A.; Euler, D. E. Pentane and isoprene in expired air from humans: Gas-chromatographic analysis of single breath Clin. Chem. 1994, 40, 1485-1488 (Pubitemid 24241126)
-
(1994)
Clinical Chemistry
, vol.40
, Issue.8
, pp. 1485-1488
-
-
Mendis, S.1
Sobotka, P.A.2
Euler, D.E.3
-
17
-
-
0041425157
-
Comparison of breath, blood and urine concentrations in the biomonitoring of environmental exposure to 1,3-butadiene, 2,5-dimethylfuran, and benzene
-
DOI 10.1007/s00420-003-0436-7
-
Perbellini, L.; Princivalle, A.; Cerpelloni, M.; Pasini, F.; Brugnone, F. Comparison of breath, blood and urine concentrations in the biomonitoring of environmental exposure to 1,3-butadiene, 2,5-dimethylfuran, and benzene Int. Arch. Occup. Environ. Health 2003, 76, 461-466 (Pubitemid 37038173)
-
(2003)
International Archives of Occupational and Environmental Health
, vol.76
, Issue.6
, pp. 461-466
-
-
Perbellini, L.1
Princivalle, A.2
Cerpelloni, M.3
Pasini, F.4
Brugnone, F.5
-
18
-
-
0036054428
-
Apartment residents' and day care workers' exposures to tetrachloroethylene and deficits in visual contrast sensitivity
-
Schreiber, J. S.; Hudnell, H. K.; Geller, A. M.; House, D. E.; Aldous, K. M.; Force, M. S.; Langguth, K.; Prohonic, E. J.; Parker, J. C. Apartment residents' and day care workers' exposures to tetrachloroethylene and deficits in visual contrast sensitivity Environ. Health Perspect. 2002, 110, 655-664
-
(2002)
Environ. Health Perspect.
, vol.110
, pp. 655-664
-
-
Schreiber, J.S.1
Hudnell, H.K.2
Geller, A.M.3
House, D.E.4
Aldous, K.M.5
Force, M.S.6
Langguth, K.7
Prohonic, E.J.8
Parker, J.C.9
-
19
-
-
0025245413
-
A device for sampling of human alveolar breath for the measurement of expired volatile organic compounds
-
Raymer, J. H.; Thomas, K. W.; Cooper, S. D.; Whitaker, D. A.; Pellizzari, E. D. A device for sampling of human alveolar breath for the measurement of expired volatile organic compounds J. Anal. Toxicol. 1990, 14, 337-344
-
(1990)
J. Anal. Toxicol.
, vol.14
, pp. 337-344
-
-
Raymer, J.H.1
Thomas, K.W.2
Cooper, S.D.3
Whitaker, D.A.4
Pellizzari, E.D.5
-
20
-
-
68149091274
-
Endogenous volatile organic compounds in breath and blood of healthy volunteers: Examining breath analysis as a surrogate for blood measurements
-
O'Hara, M. E.; Clutton-Brock, T. H.; Green, S.; Mayhew, C. A. Endogenous volatile organic compounds in breath and blood of healthy volunteers: Examining breath analysis as a surrogate for blood measurements J. Breath Res. 2009, 3, 027005
-
(2009)
J. Breath Res.
, vol.3
, pp. 027005
-
-
O'Hara, M.E.1
Clutton-Brock, T.H.2
Green, S.3
Mayhew, C.A.4
-
21
-
-
0031149661
-
Method for the collection and assay of volatile organic compounds in breath
-
DOI 10.1006/abio.1997.2069
-
Phillips, M. Method for the collection and assay of volatile organic compounds in breath Anal. Biochem. 1997, 247, 272-278 (Pubitemid 27200161)
-
(1997)
Analytical Biochemistry
, vol.247
, Issue.2
, pp. 272-278
-
-
Phillips, M.1
-
22
-
-
1642357692
-
Solid-phase microextraction: A powerful sample preparation tool prior to mass spectrometric analysis
-
DOI 10.1002/jms.606
-
Vas, G.; Vékey, K. Solid-phase microextraction: A powerful sample preparation tool prior to mass spectrometric analysis J. Mass Spectrom 2004, 39, 233-254 (Pubitemid 38379528)
-
(2004)
Journal of Mass Spectrometry
, vol.39
, Issue.3
, pp. 233-254
-
-
Vas, G.1
Vekey, K.2
-
23
-
-
0033028066
-
Air analysis by gas chromatography
-
DOI 10.1016/S0021-9673(99)00173-9, PII S0021967399001739
-
Helmig, D. Air analysis by gas chromatography J. Chromatogr., A 1999, 843, 129-146 (Pubitemid 29255873)
-
(1999)
Journal of Chromatography A
, vol.843
, Issue.1-2
, pp. 129-146
-
-
Helmig, D.1
-
24
-
-
79951887870
-
Breath analysis and artificial ventilation: Chemical identification and classification of volatile substances in exhaled breath during I.V. anesthesia
-
Hengstenberg, A.; Grossherr, M.; Meier, T.; Gehring, H. Breath analysis and artificial ventilation: Chemical identification and classification of volatile substances in exhaled breath during I.V. anesthesia Anesthesiology 2005, 103, A808
-
(2005)
Anesthesiology
, vol.103
, pp. 808
-
-
Hengstenberg, A.1
Grossherr, M.2
Meier, T.3
Gehring, H.4
-
25
-
-
0032894653
-
Headspace sampling with capillary columns
-
DOI 10.1016/S0021-9673(99)00073-4, PII S0021967399000734
-
Kolb, B. Headspace sampling with capillary columns J. Chromatogr. 1999, 842, 163-205 (Pubitemid 29229885)
-
(1999)
Journal of Chromatography A
, vol.842
, Issue.1-2
, pp. 163-205
-
-
Kolb, B.1
-
27
-
-
0016827684
-
Analysis of air pollutants using sampling tubes and gas chromatography
-
Russell, J. W. Analysis of air pollutants using sampling tubes and gas chromatography Environ. Sci. Technol. 1975, 9 (13) 1175-1178
-
(1975)
Environ. Sci. Technol.
, vol.9
, Issue.13
, pp. 1175-1178
-
-
Russell, J.W.1
-
28
-
-
0002808644
-
Collection and analysis of trace organic vapour pollutants in ambient atmospheres: The performace of a Tenax-GC adsorbent tube
-
Brown, R. H.; Purnell, C. J. Collection and analysis of trace organic vapour pollutants in ambient atmospheres: The performace of a Tenax-GC adsorbent tube J. Chromatogr., A 1979, 178 (1) 79-90
-
(1979)
J. Chromatogr., A
, vol.178
, Issue.1
, pp. 79-90
-
-
Brown, R.H.1
Purnell, C.J.2
-
29
-
-
0017079325
-
Collection and analysis of trace organic vapor pollutants in ambient atmospheres: The performance of a Tenax GC cartridge sampler for hazardous vapors
-
Pellizzari, E. D.; Bunch, J. E.; Berkley, R. E.; McRae, J. Collection and analysis of trace organic vapor pollutants in ambient atmospheres: The performance of a Tenax GC cartridge sampler for hazardous vapors Anal. Lett. 1976, 9 (1) 45-63
-
(1976)
Anal. Lett.
, vol.9
, Issue.1
, pp. 45-63
-
-
Pellizzari, E.D.1
Bunch, J.E.2
Berkley, R.E.3
McRae, J.4
-
30
-
-
0024778220
-
The application of chemically modified fused silica fibers in the extraction of organics from water matrix samples and their rapid transfer to capillary columns
-
Belardi, R. P.; Pawliszyn, J. B. The application of chemically modified fused silica fibers in the extraction of organics from water matrix samples and their rapid transfer to capillary columns Water Pollut. Res. J. Can. 1989, 24 (1) 179-91
-
(1989)
Water Pollut. Res. J. Can.
, vol.24
, Issue.1
, pp. 179-91
-
-
Belardi, R.P.1
Pawliszyn, J.B.2
-
31
-
-
0242332777
-
Solid-Phase Microextraction
-
Hinshaw, J. V. Solid-Phase Microextraction LC-GC Asia Pacific 2004, 7 (1) 1056-1061
-
(2004)
LC-GC Asia Pacific
, vol.7
, Issue.1
, pp. 1056-1061
-
-
Hinshaw, J.V.1
-
32
-
-
76849099847
-
Human breath analysis: Methods for sample collection and reduction of localized background effects
-
Martin, A. N.; Farquar, G. R.; Jones, A. D.; Frank, M. Human breath analysis: methods for sample collection and reduction of localized background effects Anal. Bioanal. Chem. 2010, 396, 739-750
-
(2010)
Anal. Bioanal. Chem.
, vol.396
, pp. 739-750
-
-
Martin, A.N.1
Farquar, G.R.2
Jones, A.D.3
Frank, M.4
-
33
-
-
26844581331
-
Solid phase microextraction for analysis of alkanes and aromatic hydrocarbons in human breath
-
DOI 10.1016/j.jchromb.2005.08.013, PII S1570023205005866
-
Yu, H.; Xu, L.; Wang, P. Solid phase microextraction for analysis of alkanes and aromatic hydrocarbons in human breath J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2005, 826, 69-74 (Pubitemid 41446436)
-
(2005)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
, vol.826
, Issue.1-2
, pp. 69-74
-
-
Yu, H.1
Xu, L.2
Wang, P.3
-
34
-
-
41249090494
-
An optimized method for determination of benzene in exhaled air by gas chromatography-mass spectrometry using solid phase microextraction as a sampling technique
-
Amorim, L. C. A.; Carneiro, J. P.; Cardeal, Z. L. An optimized method for determination of benzene in exhaled air by gas chromatography-mass spectrometry using solid phase microextraction as a sampling technique J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2008, 865, 141-146
-
(2008)
J. Chromatogr., B: Anal. Technol. Biomed. Life Sci.
, vol.865
, pp. 141-146
-
-
Amorim, L.C.A.1
Carneiro, J.P.2
Cardeal, Z.L.3
-
35
-
-
62449177156
-
The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS
-
Ligor, T.; Ligor, M.; Amann, A.; Ager, C.; Bachler, M.; Dzien, A.; Buszewski, B. The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS J. Breath Res. 2008, 2 (4) 1-8
-
(2008)
J. Breath Res.
, vol.2
, Issue.4
, pp. 1-8
-
-
Ligor, T.1
Ligor, M.2
Amann, A.3
Ager, C.4
Bachler, M.5
Dzien, A.6
Buszewski, B.7
-
36
-
-
0031568680
-
Solid-phase microextraction for the analysis of human breath
-
Grote, C.; Pawliszyn, J. Solid-phase microextraction for the analysis of human breath Anal. Chem. 1997, 69 (4) 587-596
-
(1997)
Anal. Chem.
, vol.69
, Issue.4
, pp. 587-596
-
-
Grote, C.1
Pawliszyn, J.2
-
37
-
-
0032487350
-
Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent
-
DOI 10.1016/S0003-2670(98)00294-3, PII S0003267098002943
-
Groves, W. A.; Zellers, E. T.; Frye, G. C. Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent Anal. Chim. Acta 1998, 371, 131-143 (Pubitemid 28401465)
-
(1998)
Analytica Chimica Acta
, vol.371
, Issue.2-3
, pp. 131-143
-
-
Groves, W.A.1
Zellers, E.T.2
Frye, G.C.3
-
38
-
-
0018653907
-
A gas chromatographic air analyzer fabricated on a silicon wafer
-
Terry, S. C.; Jerman, J. H.; Angell, J. B. A gas chromatographic air analyzer fabricated on a silicon wafer IEE Trans. Electron Devices 1979, 26 (12) 1880-1886 (Pubitemid 10128644)
-
(1979)
IEEE Transactions on Electron Devices
, vol.26
, Issue.12
, pp. 1880-1886
-
-
Terry, S.C.1
Jerman, J.H.2
Angell, J.B.3
-
39
-
-
33745266159
-
Gas chromatography
-
DOI 10.1021/ac060638e
-
Eiceman, G. A.; Gardea-Torresdey, J.; Dorman, F.; Overton, E.; Bhushan, A.; Dharmasena, H. P. Gas Chromatography Anal. Chem. 2006, 78 (12) 3985-3996 (Pubitemid 43927404)
-
(2006)
Analytical Chemistry
, vol.78
, Issue.12
, pp. 3985-3996
-
-
Eiceman, G.A.1
Gardea-Torresdey, J.2
Dorman, F.3
Overton, E.4
Bhushan, A.5
Dharmasena, H.P.6
-
40
-
-
0038697738
-
A microfabricated microconcentrator for sensors and gas chromatography
-
DOI 10.1016/S0021-9673(03)00560-0
-
Kim, M.; Mitra, S. A microfabricated microconcentrator for sensors and gas chromatography J. Chromatogr., A 2003, 996, 1-11 (Pubitemid 36627788)
-
(2003)
Journal of Chromatography A
, vol.996
, Issue.1-2
, pp. 1-11
-
-
Kim, M.1
Mitra, S.2
-
41
-
-
8744312792
-
Enhanced detection of m-xylene using a preconcentrator with a chemiresistor sensor
-
Davis, C. E.; Ho, C. K.; Hughes, R. C.; Thomas, M. L. Enhanced detection of m-xylene using a preconcentrator with a chemiresistor sensor Sens. Actuators, B 2005, 104 (2) 207-216
-
(2005)
Sens. Actuators, B
, vol.104
, Issue.2
, pp. 207-216
-
-
Davis, C.E.1
Ho, C.K.2
Hughes, R.C.3
Thomas, M.L.4
-
42
-
-
19744373108
-
Production and deposition of adsorbent films by plasma polymerization on low cost micromachined non-planar microchannels for preconcentration of organic compound in air
-
Lima, R. R.; Carvalho, R. A. M.; Filho, A. P. N.; Silva, M. L. P.; Demarquette, N. R. Production and deposition of adsorbent films by plasma polymerization on low cost micromachined non-planar microchannels for preconcentration of organic compound in air Sens. Actuators, B 2005, 108, 435-444
-
(2005)
Sens. Actuators, B
, vol.108
, pp. 435-444
-
-
Lima, R.R.1
Carvalho, R.A.M.2
Filho, A.P.N.3
Silva, M.L.P.4
Demarquette, N.R.5
-
43
-
-
22444451077
-
Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system
-
DOI 10.1109/JMEMS.2005.844842
-
Tian, W.-C.; Chan, H. K. L.; Chia-Jung, L.; Pang, S. W.; Zellers, E. T. Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system J. Microelectromech. Syst. 2005, 14 (3) 498-507 (Pubitemid 41005069)
-
(2005)
Journal of Microelectromechanical Systems
, vol.14
, Issue.3
, pp. 498-507
-
-
Tian, W.-C.1
Chan, H.K.L.2
Lu, C.-J.3
Pang, S.W.4
Zellers, E.T.5
-
44
-
-
33645730496
-
Study of preconcentration of non-polar compounds in microchannels with constrictions
-
Simoes, E. W.; de Souza, S. G.; da Silva, M. L. P.; Furlan, R.; Maldonado Peres, H. E. Study of preconcentration of non-polar compounds in microchannels with constrictions Sens. Actuators, B 2006, 115 (1) 232-239
-
(2006)
Sens. Actuators, B
, vol.115
, Issue.1
, pp. 232-239
-
-
Simoes, E.W.1
De Souza, S.G.2
Da Silva, M.L.P.3
Furlan, R.4
Maldonado Peres, H.E.5
-
45
-
-
34848889025
-
Application of carbon nano-powders for a gas micro-preconcentrator
-
DOI 10.1016/j.snb.2007.07.029, PII S0925400507004832, Eurosensors XX The 20th European Conference on Solid-State Transducers
-
Pijolat, C.; Camara, M.; Courbat, J.; Viricelle, J. P.; Briand, D.; de Rooij, N. F. Application of carbon nano-powders for a gas micro-preconcentrator Sens. Actuators, B 2007, 127 (1) 179-185 (Pubitemid 47503721)
-
(2007)
Sensors and Actuators, B: Chemical
, vol.127
, Issue.1
, pp. 179-185
-
-
Pijolat, C.1
Camara, M.2
Courbat, J.3
Viricelle, J.-P.4
Briand, D.5
De Rooij, N.F.6
-
46
-
-
34548604301
-
Microfabricated vapor preconcentrator for portable ion mobility spectroscopy
-
DOI 10.1016/j.snb.2007.03.040, PII S0925400507002365
-
Martin, M.; Crain, M.; Walsh, K.; McGill, R. A.; Houser, E.; Stepnowski, J.; Stepnowski, S.; Wu, H.-D.; Ross, S. Microfabricated vapor preconcentrator for portable ion mobility spectroscopy Sens. Actuators, B 2007, 126 (2) 447-454 (Pubitemid 47405170)
-
(2007)
Sensors and Actuators, B: Chemical
, vol.126
, Issue.2
, pp. 447-454
-
-
Martin, M.1
Crain, M.2
Walsh, K.3
McGill, R.A.4
Houser, E.5
Stepnowski, J.6
Stepnowski, S.7
Wu, H.-D.8
Ross, S.9
-
47
-
-
33947195897
-
Membrane-suspended microgrid as a gas preconcentrator for chromatographic applications
-
DOI 10.1016/j.sna.2006.07.005, PII S0924424706005036, Special Issue of The Micromechanics section of Sensors and Actuators
-
Ruiz, A. M.; Gracia, I.; Sabate, N.; Ivanov, P.; Sanchez, A.; Duch, M.; Gerboles, M.; Moreno, A.; Cane, C. Membrane-suspended microgrid as a gas preconcentrator for chromatographic applications Sens. Actuators, A 2007, 135 (1) 192-196 (Pubitemid 46428098)
-
(2007)
Sensors and Actuators, A: Physical
, vol.135
, Issue.1
, pp. 192-196
-
-
Ruiz, A.M.1
Gracia, I.2
Sabate, N.3
Ivanov, P.4
Sanchez, A.5
Duch, M.6
Gerboles, M.7
Moreno, A.8
Cane, C.9
-
48
-
-
34247101712
-
A fast-response microfluidic gas concentrating device for environmental sensing
-
DOI 10.1016/j.sna.2006.11.035, PII S0924424706007400
-
Li, S.; Day, J. C.; Park, J. J.; Cadou, C. P.; Ghodssi, R. A fast-response microfluidic gas concentrating device for environmental sensing Sens. Actuators, A 2007, 136 (1) 69-79 (Pubitemid 46590681)
-
(2007)
Sensors and Actuators, A: Physical
, vol.136
, Issue.1
, pp. 69-79
-
-
Li, S.1
Day, J.C.2
Park, J.J.3
Cadou, C.P.4
Ghodssi, R.5
-
49
-
-
58149326766
-
The design, fabrication and characterization of a silicon microheater for an integrated MEMS gas preconcentrator
-
Junghoon, Y.; Field, C. R.; Byunghoon, B.; Masel, R. I.; Shannon, M. A. The design, fabrication and characterization of a silicon microheater for an integrated MEMS gas preconcentrator J. Micromech. Microeng. 2008, 18 (12) 125001
-
(2008)
J. Micromech. Microeng.
, vol.18
, Issue.12
, pp. 125001
-
-
Junghoon, Y.1
Field, C.R.2
Byunghoon, B.3
Masel, R.I.4
Shannon, M.A.5
-
50
-
-
43749121166
-
Sub-ppm gas sensor detection via spiral μ-preconcentrator
-
DOI 10.1016/j.snb.2008.01.019, PII S0925400508000555
-
Gràcia, I.; Ivanov, P.; Blanco, F.; Sabaté, N.; Vilanova, X.; Correig, X.; Fonseca, L.; Figueras, E.; Santander, J.; Cané, C. Sub-ppm gas sensor detection via spiral m-preconcentrator Sens. Actuators, B 2008, 132 (1) 149-154 (Pubitemid 351694414)
-
(2008)
Sensors and Actuators, B: Chemical
, vol.132
, Issue.1
, pp. 149-154
-
-
Gracia, I.1
Ivanov, P.2
Blanco, F.3
Sabate, N.4
Vilanova, X.5
Correig, X.6
Fonseca, L.7
Figueras, E.8
Santander, J.9
Cane, C.10
-
51
-
-
57449117476
-
Mass-sensitive microfabricated chemical preconcentrator
-
Manginell, R. P.; Adkins, D. R.; Moorman, M. W.; Hadizadeh, R.; Copic, D.; Porter, D. A.; Anderson, J. M.; Hietala, V. M.; Bryan, J. R.; Wheeler, D. R.; Pfeifer, K. B.; Rumpf, A. Mass-sensitive microfabricated chemical preconcentrator J. Microelectromech. Syst. 2008, 17 (6) 1396-1407
-
(2008)
J. Microelectromech. Syst.
, vol.17
, Issue.6
, pp. 1396-1407
-
-
Manginell, R.P.1
Adkins, D.R.2
Moorman, M.W.3
Hadizadeh, R.4
Copic, D.5
Porter, D.A.6
Anderson, J.M.7
Hietala, V.M.8
Bryan, J.R.9
Wheeler, D.R.10
Pfeifer, K.B.11
Rumpf, A.12
-
52
-
-
42749092737
-
Microfabricated chemical preconcentrators for gas-phase microanalytical detection systems
-
Voiculescu, I.; Zaghloul, M.; Narasimhan, N. Microfabricated chemical preconcentrators for gas-phase microanalytical detection systems TrAC, Trends Anal. Chem. 2008, 27 (4) 327-343
-
(2008)
TrAC, Trends Anal. Chem.
, vol.27
, Issue.4
, pp. 327-343
-
-
Voiculescu, I.1
Zaghloul, M.2
Narasimhan, N.3
-
53
-
-
46449112643
-
MEMS-Based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents
-
Alfeeli, B.; Cho, D.; Ashraf-Khorassani, M.; Taylor, L. T.; Agah, M. MEMS-Based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents Sens. Actuators, B 2008, 133 (1) 24-32
-
(2008)
Sens. Actuators, B
, vol.133
, Issue.1
, pp. 24-32
-
-
Alfeeli, B.1
Cho, D.2
Ashraf-Khorassani, M.3
Taylor, L.T.4
Agah, M.5
-
54
-
-
14744283594
-
Selectivity enhancement of metal oxide gas sensors using a micromachined gas chromatographic column
-
DOI 10.1016/j.snb.2004.06.036, PII S0925400504004678
-
Zampolli, S.; Elmi, I.; Stürmann, J.; Nicoletti, S.; Dori, L.; Cardinali, G. C. Selectivity enhancement of metal oxide gas sensors using a micromachined gas chromatographic column Sens. Actuators, B 2005, 105 (2) 400-406 (Pubitemid 40330114)
-
(2005)
Sensors and Actuators, B: Chemical
, vol.105
, Issue.2
, pp. 400-406
-
-
Zampolli, S.1
Elmi, I.2
Sturmann, J.3
Nicoletti, S.4
Dori, L.5
Cardinali, G.C.6
-
55
-
-
33750024594
-
High-speed MEMS-based gas chromatography
-
DOI 10.1109/JMEMS.2006.879708
-
Agah, M.; Lambertus, G. R.; Sacks, R.; Wise, K. High-speed MEMS-based gas chromatography J. Microelectromech. Syst. 2006, 15 (5) 1371-8 (Pubitemid 44566955)
-
(2006)
Journal of Microelectromechanical Systems
, vol.15
, Issue.5
, pp. 1371-1378
-
-
Agah, M.1
Lambertus, G.R.2
Sacks, R.3
Wise, K.4
-
56
-
-
34548019974
-
Low-mass PECVD oxynitride gas chromatographic columns
-
DOI 10.1109/JMEMS.2007.893515
-
Agah, M.; Wise, K. D. Low-Mass PECVD oxynitride gas chromatographic columns J. Microelectromech. Syst. 2007, 16 (4) 853-860 (Pubitemid 47278829)
-
(2007)
Journal of Microelectromechanical Systems
, vol.16
, Issue.4
, pp. 853-860
-
-
Agah, M.1
Wise, K.D.2
-
57
-
-
34948889295
-
A low-power pressure- and temperature-programmable micro gas chromatography column
-
DOI 10.1109/JMEMS.2007.902470
-
Potkay, J. A.; Lambertus, G. R.; Sacks, R. D.; Wise, K. D. A low-power pressure- and temperature-programmable micro gas chromatography column J. Microelectromech. Syst. 2007, 16 (5) 1071-1079 (Pubitemid 47528005)
-
(2007)
Journal of Microelectromechanical Systems
, vol.16
, Issue.5
, pp. 1071-1079
-
-
Potkay, J.A.1
Lambertus, G.R.2
Sacks, R.D.3
Wise, K.D.4
-
58
-
-
33845751140
-
Fabrication of micro-gas chromatograph columns for fast chromatography
-
DOI 10.1007/s00542-006-0210-3, HARMST, High Aspect Ration Micro Structure Technology Workshop
-
Bhushan, A.; Yemane, D.; Trudell, D.; Overton, E.; Goettert, J. Fabrication of micro-gas chromatograph columns for fast chromatography Microsyst. Technol. 2007, 13 (3) 361-368 (Pubitemid 46012833)
-
(2007)
Microsystem Technologies
, vol.13
, Issue.3-4
, pp. 361-368
-
-
Bhushan, A.1
Yemane, D.2
Trudell, D.3
Overton, E.B.4
Goettert, J.5
-
59
-
-
46549089960
-
Micro gas analyzers for environmental and medical applications
-
Ohira, S.-I.; Toda, K. Micro gas analyzers for environmental and medical applications Anal. Chim. Acta 2008, 619 (2) 143-156
-
(2008)
Anal. Chim. Acta
, vol.619
, Issue.2
, pp. 143-156
-
-
Ohira, S.-I.1
Toda, K.2
-
60
-
-
60449092230
-
Design, modeling, and fabrication of MEMS-based multicapillary gas chromatographic columns
-
Zareian-Jahromi, M. A.; Ashraf-Khorassani, M.; Taylor, L. T.; Agah, M. Design, modeling, and fabrication of MEMS-based multicapillary gas chromatographic columns J. Microelectromech. Syst. 2009, 18 (1) 28-37
-
(2009)
J. Microelectromech. Syst.
, vol.18
, Issue.1
, pp. 28-37
-
-
Zareian-Jahromi, M.A.1
Ashraf-Khorassani, M.2
Taylor, L.T.3
Agah, M.4
-
61
-
-
67949098846
-
MEMS-based semi-packed gas chromatography columns
-
Ali, S.; Ashraf-Khorassani, M.; Taylor, L. T.; Agah, M. MEMS-based semi-packed gas chromatography columns Sens. Actuators, B 2009, 141 (1) 309-315
-
(2009)
Sens. Actuators, B
, vol.141
, Issue.1
, pp. 309-315
-
-
Ali, S.1
Ashraf-Khorassani, M.2
Taylor, L.T.3
Agah, M.4
-
62
-
-
71449116498
-
A micro gas chromatograph for high-speed determinations of explosive vapors
-
In
-
Serrano, G.; Chang, H.; Zellers, E. T. A micro gas chromatograph for high-speed determinations of explosive vapors.In Proceedings of Solid-State Sensors, Actuators and Microsystems Conference, Transducers, Denver, CO, June 21-25, 2009; pp 1654-1657.
-
Proceedings of Solid-State Sensors, Actuators and Microsystems Conference, Transducers, Denver, CO, June 21-25, 2009
, pp. 1654-1657
-
-
Serrano, G.1
Chang, H.2
Zellers, E.T.3
-
63
-
-
71949119119
-
The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding
-
Radadia, A. D.; Salehi-Khojin, A.; Masel, R. I.; Shannon, M. A. The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding J. Micromech. Microeng. 2010, 20 (1) 015002
-
(2010)
J. Micromech. Microeng.
, vol.20
, Issue.1
, pp. 015002
-
-
Radadia, A.D.1
Salehi-Khojin, A.2
Masel, R.I.3
Shannon, M.A.4
-
64
-
-
77950594094
-
Microfabricated gas chromatography columns with mono-layer protected gold stationary phases
-
Zareian-Jahromi, M. A.; Agah, M. Microfabricated gas chromatography columns with mono-layer protected gold stationary phases J. Microelectromech. Syst. 2010, 19 (2) 294-304
-
(2010)
J. Microelectromech. Syst.
, vol.19
, Issue.2
, pp. 294-304
-
-
Zareian-Jahromi, M.A.1
Agah, M.2
-
65
-
-
0036544179
-
Thermal and gas-sensing properties of a micromachined thermal conductivity sensor for the detection of hydrogen in automotive applications
-
DOI 10.1016/S0924-4247(01)00825-1, PII S0924424701008251
-
Simon, I.; Arndt, M. Thermal and gas-sensing properties of a micromachined thermal conductivity sensor for the detection of hydrogen in automotive applications Sens. Actuators, A 2002, 97-98, 104-108 (Pubitemid 34758715)
-
(2002)
Sensors and Actuators, A: Physical
, vol.97-98
, pp. 104-108
-
-
Simon, I.1
Arndt, M.2
-
66
-
-
28544434645
-
Silicon microfabricated column with microfabricated differential mobility spectrometer for GC analysis of volatile organic compounds
-
DOI 10.1021/ac051216s
-
Lambertus, G. R.; Fix, C. S.; Reidy, S. M.; Miller, R. A.; Wheeler, D.; Nazarov, E.; Sacks, R. Silicon microfabricated column with microfabricated differential mobility spectrometer for GC analysis of volatile organic compounds Anal. Chem. 2005, 77 (23) 7563-7571 (Pubitemid 41746223)
-
(2005)
Analytical Chemistry
, vol.77
, Issue.23
, pp. 7563-7571
-
-
Lambertus, G.R.1
Fix, C.S.2
Reidy, S.M.3
Miller, R.A.4
Wheeler, D.5
Nazarov, E.6
Sacks, R.7
-
67
-
-
33846600416
-
Microfabricated thermal conductivity detector for the micro-ChemLab™
-
DOI 10.1016/j.snb.2006.04.107, PII S0925400506003352
-
Cruz, D.; Chang, J. P.; Showalter, S. K.; Gelbard, F.; Manginell, R. P.; Blain, M. G. Microfabricated thermal conductivity detector for the micro-ChemLab Sens. Actuators, B 2007, 121 (2) 414-422 (Pubitemid 46186887)
-
(2007)
Sensors and Actuators, B: Chemical
, vol.121
, Issue.2
, pp. 414-422
-
-
Cruz, D.1
Chang, J.P.2
Showalter, S.K.3
Gelbard, F.4
Manginell, R.P.5
Blain, M.G.6
-
68
-
-
57249091615
-
A planar micro-flame ionization detector with an integrated guard electrode
-
Kuipers, W. J.; Muller, J. A planar micro-flame ionization detector with an integrated guard electrode J. Micromech. Microeng. 2008, 6, 064015
-
(2008)
J. Micromech. Microeng.
, vol.6
, pp. 064015
-
-
Kuipers, W.J.1
Muller, J.2
-
69
-
-
65949097295
-
High sensitivity micro-thermal conductivity detector for gas chromatography
-
In
-
Kaanta, B. C.; Chen, H.; Lambertus, G.; Steinecker, W. H.; Zhdaneev, O.; Zhang, X. High sensitivity micro-thermal conductivity detector for gas chromatography. In Proceedings of Micro Electro Mechanical Systems, MEMS 2009. IEEE 22nd International Conference, Sorento, Italy, Jan 25-29, 2009; pp 264-267.
-
Proceedings of Micro Electro Mechanical Systems, MEMS 2009. IEEE 22nd International Conference, Sorento, Italy, Jan 25-29, 2009
, pp. 264-267
-
-
Kaanta, B.C.1
Chen, H.2
Lambertus, G.3
Steinecker, W.H.4
Zhdaneev, O.5
Zhang, X.6
-
70
-
-
71449085694
-
Nanoscale chemiresistor arrays with patterned nanoparticle interface layers for micro gas chromatography
-
In
-
Bohrer, F. I.; Covington, E.; Kurdak, C.; Zellers, E. T. Nanoscale chemiresistor arrays with patterned nanoparticle interface layers for micro gas chromatography. In Proceedings of Solid-State Sensors, Actuators and Microsystems Conference, Transducers 2009, Denver, CO, June 21-25, 2009; pp 148-151.
-
Proceedings of Solid-State Sensors, Actuators and Microsystems Conference, Transducers 2009, Denver, CO, June 21-25, 2009
, pp. 148-151
-
-
Bohrer, F.I.1
Covington, E.2
Kurdak, C.3
Zellers, E.T.4
-
71
-
-
78650620954
-
A Micro Gas Chromatography Chip with an Embedded Non-Cascaded Thermal Conductivity Detector
-
Narayanan, S.; Alfeeli, B.; Agah, M. A Micro Gas Chromatography Chip with an Embedded Non-Cascaded Thermal Conductivity Detector Proc. Eng. 2010, 5, 29-32
-
(2010)
Proc. Eng.
, vol.5
, pp. 29-32
-
-
Narayanan, S.1
Alfeeli, B.2
Agah, M.3
-
72
-
-
84888436592
-
Microfabricated gas phase chemical analysis systems
-
In
-
Frye-Mason, G. C.; Manginell, R. P.; Heller, E. J.; Matzke, C. M.; Casalnuovo, S. A.; Hietala, V. M.; Kottenstette, R. J.; Lewis, P. R.; Wong, C. C. Microfabricated gas phase chemical analysis systems. In Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference; pp 60-1.
-
Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference
, pp. 60-1
-
-
Frye-Mason, G.C.1
Manginell, R.P.2
Heller, E.J.3
Matzke, C.M.4
Casalnuovo, S.A.5
Hietala, V.M.6
Kottenstette, R.J.7
Lewis, P.R.8
Wong, C.C.9
-
73
-
-
84983541775
-
DNA-coated nanosensors for breath analysis
-
Johnson, A; Khamis, S. M.; Preti, G.; Kwak, J.; Gelperin, A. DNA-coated nanosensors for breath analysis IEE Sens. J. 2010, 10 (1) 159-166
-
(2010)
IEE Sens. J.
, vol.10
, Issue.1
, pp. 159-166
-
-
Johnson, A.1
Khamis, S.M.2
Preti, G.3
Kwak, J.4
Gelperin, A.5
-
74
-
-
70350676329
-
Diagnosing lung cancer in exhaled breath using gold nanoparticles
-
Peng, G.; Tisch, U.; Adams, O.; Hakim, M.; Shehada, N.; Broza, Y. Y.; Billan, S.; Abdah-Bortnyak, R.; Kuten, A.; Haick, H. Diagnosing lung cancer in exhaled breath using gold nanoparticles Nat. Nanotechnol. 2009, 4, 669-673
-
(2009)
Nat. Nanotechnol.
, vol.4
, pp. 669-673
-
-
Peng, G.1
Tisch, U.2
Adams, O.3
Hakim, M.4
Shehada, N.5
Broza, Y.Y.6
Billan, S.7
Abdah-Bortnyak, R.8
Kuten, A.9
Haick, H.10
-
75
-
-
0030694441
-
A quantitative definition of exposure and related concepts
-
Zartarian, V. G.; Ott, W. R.; Duan, N. A quantitative definition of exposure and related concepts J. Exposure Anal. Environ. Epidemiol. 1997, 7 (4) 411-437 (Pubitemid 27455607)
-
(1997)
Journal of Exposure Analysis and Environmental Epidemiology
, vol.7
, Issue.4
, pp. 411-437
-
-
Zartarian, V.G.1
Ott, W.R.2
Duan, N.3
-
76
-
-
0001767803
-
Transport and uptake of inhaled gases
-
In; Watson, A. Y. Bates, R. R. Kennedy, D. National Academies Press: Washington, DC.
-
Ultman, J. S. Transport and uptake of inhaled gases. In Air Pollution, the Automobile, and Public Health; Watson, A. Y.; Bates, R. R.; Kennedy, D., Eds.; National Academies Press: Washington, DC, 1988.
-
(1988)
Air Pollution, the Automobile, and Public Health
-
-
Ultman, J.S.1
-
77
-
-
80053394451
-
Inhalation exposure, uptake, and dose
-
In; Ott, W. R. Steinemann, A. C. Wallace, L. A. CRC Press: Boca Raton, FL.
-
Ferro, A. R.; Hildemann, L. M. Inhalation exposure, uptake, and dose. In Exposure Analysis; Ott, W. R.; Steinemann, A. C.; Wallace, L. A., Eds.; CRC Press: Boca Raton, FL, 2007.
-
(2007)
Exposure Analysis
-
-
Ferro, A.R.1
Hildemann, L.M.2
-
78
-
-
0023387916
-
The TEAM Study: Personal exposures to toxic substances in air, drinking water, and breath of 400 residents of New Jersey, North Carolina, and North Dakota
-
Wallace, L. A.; Pellizzari, E. D.; Hartwell, T. D.; Sparacino, C.; Whitmore, R.; Sheldon, L.; Zelon, H.; Perritt, R. The TEAM study: Personal exposures to toxic substances in air, drinking water, and breath of 400 residents of New Jersey, North Carolina, and North Dakota Environ. Res. 1987, 43 (2) 290-307 (Pubitemid 17137320)
-
(1987)
Environmental Research
, vol.43
, Issue.2
, pp. 290-307
-
-
Wallace, L.A.1
Pellizzari, E.D.2
Hartwell, T.D.3
-
79
-
-
21244485746
-
Indoor air and human exposure assessment - Needs and approaches
-
DOI 10.1016/j.etp.2005.05.002, PII S0940299305000345
-
Kotzias, D. Indoor air and human exposure assessment - needs and approaches Exp. Toxicol. Pathol. 2005, 57, 5-7 (Pubitemid 40884479)
-
(2005)
Experimental and Toxicologic Pathology
, vol.57
, Issue.SUPPL. 1
, pp. 5-7
-
-
Kotzias, D.1
-
80
-
-
79958046933
-
The AIRMEX study - VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data
-
Geiss, O.; Giannopoulos, G.; Tirendi, S.; Barrero-Moreno, J.; Larsen, B. R.; Kotzias, D. The AIRMEX study-VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data Atmos. Environ. 2011, 45 (22) 3676-3684
-
(2011)
Atmos. Environ.
, vol.45
, Issue.22
, pp. 3676-3684
-
-
Geiss, O.1
Giannopoulos, G.2
Tirendi, S.3
Barrero-Moreno, J.4
Larsen, B.R.5
Kotzias, D.6
-
81
-
-
0034918863
-
The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants
-
DOI 10.1038/sj.jea.7500165
-
Klepeis, N. E.; Nelson, W. C.; Ott, W. R.; Robinson, J. P.; Tsang, A. M.; Switzer, P.; Behar, J. V.; Hern, S. C.; Engelmann, W. H. The national human activity pattern survey (NHAPS): A resource for assessing exposure to environmental pollutants J. Exposure Anal. Environ. Epidemiol. 2001, 11, 231-252 (Pubitemid 32701612)
-
(2001)
Journal of Exposure Analysis and Environmental Epidemiology
, vol.11
, Issue.3
, pp. 231-252
-
-
Klepeis, N.E.1
Nelson, W.C.2
Ott, W.R.3
Robinson, J.P.4
Tsang, A.M.5
Switzer, P.6
Behar, J.V.7
Hern, S.C.8
Engelmann, W.H.9
-
82
-
-
40049098469
-
The health effects of nonindustrial indoor air pollution
-
Bernstein, J. A.; Alexis, N.; Bacchus, H.; Bernstein, I. L.; Fritz, P.; Horner, E.; Li, N.; Mason, S.; Nel, A.; Oullette, J.; Reijula, K.; Reponen, R.; Seltzer, J.; Smith, A.; Tarlo, S. M. The health effects of nonindustrial indoor air pollution J. Allergy Clin. Immunol. 2008, 121, 585-591
-
(2008)
J. Allergy Clin. Immunol.
, vol.121
, pp. 585-591
-
-
Bernstein, J.A.1
Alexis, N.2
Bacchus, H.3
Bernstein, I.L.4
Fritz, P.5
Horner, E.6
Li, N.7
Mason, S.8
Nel, A.9
Oullette, J.10
Reijula, K.11
Reponen, R.12
Seltzer, J.13
Smith, A.14
Tarlo, S.M.15
-
83
-
-
35148892258
-
Phthalates: Toxicology and exposure
-
DOI 10.1016/j.ijheh.2007.07.011, PII S1438463907001125
-
Heudorf, U.; Mersch-Sundermann, V.; Angerer, J. Phthalates: Toxicology and exposure Int. J. Hyg. Environ. Health 2007, 623-634 (Pubitemid 47539285)
-
(2007)
International Journal of Hygiene and Environmental Health
, vol.210
, Issue.5
, pp. 623-634
-
-
Heudorf, U.1
Mersch-Sundermann, V.2
Angerer, J.3
-
84
-
-
0032678261
-
Terpene emissions from particleboard and medium-density fiberboard products
-
Baumann, M. G. D.; Batterman, S. A.; Zhang, G.-Z. Terpene emissions from particle-board and medium density fiberboard products For. Prod. J. 1999, 49, 49-56 (Pubitemid 129693490)
-
(1999)
Forest Products Journal
, vol.49
, Issue.1
, pp. 49-56
-
-
Baumann, M.G.D.1
Batterman, S.A.2
Zhang, G.-Z.3
-
85
-
-
0034272231
-
Aldehyde emissions from particleboard and medium density fiberboard products
-
Baumann, M. G. D.; Lorenz, L. F.; Batterman, S. A.; Zhang, G.-Z. Aldehyde emissions from particleboard and medium density fiberboard products For. Prod. J. 2000, 50, 75-82
-
(2000)
For. Prod. J.
, vol.50
, pp. 75-82
-
-
Baumann, M.G.D.1
Lorenz, L.F.2
Batterman, S.A.3
Zhang, G.-Z.4
-
86
-
-
27244442382
-
Phthalates in indoor dust and their association with building characteristics
-
DOI 10.1289/ehp.7809
-
Bornehag, C.-G.; Lundgren, B.; Weschler, C. J.; Sigsgaard, T.; Hagerhed-Engman, L.; Sundell, J. Phthalates in indoor dust and their association with building characteristics Environ. Health Perspect. 2005, 113, 1399-1404 (Pubitemid 41512000)
-
(2005)
Environmental Health Perspectives
, vol.113
, Issue.10
, pp. 1399-1404
-
-
Bornehag, C.-G.1
Lundgren, B.2
Weschler, C.J.3
Sigsgaard, T.4
Hagerhed-Engman, L.5
Sundell, J.6
-
87
-
-
32044441236
-
Aesthetic issues for drinking water
-
DOI 10.2166/wh.2005.034
-
Dietrich, A. M. Aesthetic issues for drinking water J. Water Health 2006, 4, 11-16 (Pubitemid 43192773)
-
(2006)
Journal of Water and Health
, vol.4
, Issue.SUPPL. 1
, pp. 11-16
-
-
Dietrich, A.M.1
-
88
-
-
33846505606
-
Sensory aspects and water quality impacts of chlorinated and chloraminated drinking water in contact with HDPE and cPVC pipe
-
DOI 10.1016/j.watres.2006.11.028, PII S0043135406006713
-
Heim, T.; Dietrich, A. M. Sensory aspects and water quality impacts of chlorinated and chloraminated drinking water in contact with HDPE and cPVC pipe Water Res. 2007, 41, 757-764 (Pubitemid 46157039)
-
(2007)
Water Research
, vol.41
, Issue.4
, pp. 757-764
-
-
Heim, T.H.1
Dietrich, A.M.2
-
89
-
-
79960205538
-
Impact of chlorinated water exposure on contaminant transport and surface and bulk properties of HDPE and PEX potable water pipes
-
Whelton, A.; Dietrich, A. M.; Gallagher, D. L. Impact of chlorinated water exposure on contaminant transport and surface and bulk properties of HDPE and PEX potable water pipes J. Environ. Eng. 2011, 137 (7) 559-568
-
(2011)
J. Environ. Eng.
, vol.137
, Issue.7
, pp. 559-568
-
-
Whelton, A.1
Dietrich, A.M.2
Gallagher, D.L.3
-
90
-
-
71449107218
-
Emissions of 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate (TMPD-MIB) from latex paint: A Critical Review
-
Corsi, R. L.; Lin, C.-C. Emissions of 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate (TMPD-MIB) from latex paint: A Critical Review Crit. Rev. Environ. Sci. Technol. 2006, 39 (12) 1052-1080
-
(2006)
Crit. Rev. Environ. Sci. Technol.
, vol.39
, Issue.12
, pp. 1052-1080
-
-
Corsi, R.L.1
Lin, C.-C.2
-
91
-
-
2442641429
-
Full-scale chamber investigation and simulation of air freshener emissions in the presence of ozone
-
Liu, X. Y.; Mason, M.; Krebs, K.; Sparks, L. Full-scale chamber investigation and simulation of air freshener emissions in the presence of ozone Environ. Sci. Technol. 2004, 38, 2802-2812 (Pubitemid 38656424)
-
(2004)
Environmental Science and Technology
, vol.38
, Issue.10
, pp. 2802-2812
-
-
Liu, X.1
Mason, M.2
Krebs, K.3
Sparks, L.4
-
92
-
-
34047251131
-
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
-
DOI 10.1016/j.atmosenv.2006.06.005, PII S1352231006006364
-
Singer, B. C.; Coleman, B. K.; Destaillats, H.; Hodgson, A. T.; Lunden, M. M.; Weschler, C. J.; Nazaroff, W. W. Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone Atmos. Environ. 2006, 40, 6696-6710 (Pubitemid 46550292)
-
(2006)
Atmospheric Environment
, vol.40
, Issue.35
, pp. 6696-6710
-
-
Singer, B.C.1
Coleman, B.K.2
Destaillats, H.3
Hodgson, A.T.4
Lunden, M.M.5
Weschler, C.J.6
Nazaroff, W.W.7
-
93
-
-
56449088989
-
Changes in indoor pollutants since the 1950s
-
Weschler, C. J. Changes in indoor pollutants since the 1950s Atmos. Environ. 2009, 43 (1) 153-169
-
(2009)
Atmos. Environ.
, vol.43
, Issue.1
, pp. 153-169
-
-
Weschler, C.J.1
-
94
-
-
84856571751
-
-
APE (alkylphenol ethoxylates) Research Council, APE Product Information; accessed May 2011.
-
APE (alkylphenol ethoxylates) Research Council, APE Product Information; http://www.aperc.org/productinfo.htm; accessed May 2011.
-
-
-
-
95
-
-
0033374555
-
Epidemiologic studies of fatal and nonfatal cardiovascular disease and ETS exposure from spousal smoking
-
Thun, M.; Henley, J.; Apicella, L. Epidemiological studies of fatal and nonfatal cardiovascular disease and ETS exposure from spousal smoking Environ. Health. Perspect. 1999, 107 (Suppl 6) 841-846 (Pubitemid 30068182)
-
(1999)
Environmental Health Perspectives
, vol.107
, Issue.SUPPL. 6
, pp. 841-846
-
-
Thun, M.1
Henley, J.2
Apicella, L.3
-
96
-
-
0021688385
-
The sick building syndrome: Prevalence studies
-
Finnegan, M. J.; Pickering, C. A.; Burge, P. S. The sick building syndrome: Prevalence studies Br. Med. J. (Clin. Res. Ed.) 1984, 289, 1573
-
(1984)
Br. Med. J. (Clin. Res. Ed.)
, vol.289
, pp. 1573
-
-
Finnegan, M.J.1
Pickering, C.A.2
Burge, P.S.3
-
97
-
-
33645243567
-
Organic compounds in office environments - Sensory irritation, odor, measurements and the role of reactive chemistry
-
Wolkoff, P.; Wilkins, C. K.; Clausen, P. A.; Nielsen, G. D. Organic compounds in office environments - Sensory irritation, odor, measurements and the role of reactive chemistry Indoor Air 2006, 16 (1) 7-19
-
(2006)
Indoor Air
, vol.16
, Issue.1
, pp. 7-19
-
-
Wolkoff, P.1
Wilkins, C.K.2
Clausen, P.A.3
Nielsen, G.D.4
-
98
-
-
70350335851
-
Evaluating methods for predicting indoor residential volatile organic compound concentration distributions
-
Dodson, R. E.; Levy, J. I.; Houseman, E. A.; Spengler, J. D.; Bennett, D. H. Evaluating methods for predicting indoor residential volatile organic compound concentration distributions J. Exposure Sci. Environ. Epidemiol. 2009, 19, 682-693
-
(2009)
J. Exposure Sci. Environ. Epidemiol.
, vol.19
, pp. 682-693
-
-
Dodson, R.E.1
Levy, J.I.2
Houseman, E.A.3
Spengler, J.D.4
Bennett, D.H.5
-
99
-
-
77952934972
-
Real-time breath gas analysis for pharmacokinetics: Monitoring exhaled breath by online proton-transfer reaction mass spectrometry after ingestion of eucalyptol-containing capsules
-
Beauchamp, J.; Kirsch, F.; Buettner, A. Real-time breath gas analysis for pharmacokinetics: Monitoring exhaled breath by online proton-transfer reaction mass spectrometry after ingestion of eucalyptol-containing capsules J. Breath Res. 2010, 4, 1-12
-
(2010)
J. Breath Res.
, vol.4
, pp. 1-12
-
-
Beauchamp, J.1
Kirsch, F.2
Buettner, A.3
-
100
-
-
79952727561
-
-
World Health Organization: Copenhagen, Denmark.
-
WHO guidelines for indoor air quality: Selected pollutants; World Health Organization: Copenhagen, Denmark, 2010; ww.euro.who.int/-data/assets/pdf-file/ 0009/128169/e94535.pdf.
-
(2010)
WHO Guidelines for Indoor Air Quality: Selected Pollutants
-
-
-
101
-
-
30344457037
-
Prevalence and implementation of IAQ programs in U.S. schools
-
DOI 10.1289/ehp.7881
-
Moglia, D.; Smith, A.; MacIntosh, D. L.; Somers, J. L. Prevalence and implementation of IAQ programs in U.S. schools Environ. Health Perspect. 2006, 114 (1) 141-146 (Pubitemid 43056882)
-
(2006)
Environmental Health Perspectives
, vol.114
, Issue.1
, pp. 141-146
-
-
Moglia, D.1
Smith, A.2
MacIntosh, D.L.3
Somers, J.L.4
-
102
-
-
77950629937
-
MEMS-based selective preconcentration of trace level breath analytes
-
Alfeeli, B.; Agah, M. MEMS-based selective preconcentration of trace level breath analytes IEEE Sens. J. 2009, 9 (9) 1068-1075
-
(2009)
IEEE Sens. J.
, vol.9
, Issue.9
, pp. 1068-1075
-
-
Alfeeli, B.1
Agah, M.2
-
103
-
-
12344256993
-
Breath analysis: Trends in techniques and clinical applications
-
DOI 10.1016/j.microc.2004.10.008, PII S0026265X04001973, XI Italian Hungarian Symposium on Spectrochemistry
-
Di Francesco, F.; Fuoco, R.; Trivella, M. G.; Ceccarini, A. Breath analysis: Trends in techniques and clinical applications Microchem. J. 2005, 79, 405-410 (Pubitemid 40126348)
-
(2005)
Microchemical Journal
, vol.79
, Issue.1-2
, pp. 405-410
-
-
Di Francesco, F.1
Fuoco, R.2
Trivella, M.G.3
Ceccarini, A.4
|