Volumn 34, Issue 13, 2011, Pages 1133-1156

Developments in fast liquid chromatographic analysis of pharmaceuticals

Author keywords

core shell particles; fast liquid chromatography; HTLC; monolith; pharmaceutical analysis; UHPLC

Indexed keywords

CORE-SHELL PARTICLE; FAST LIQUID CHROMATOGRAPHY; HTLC; MONOLITH; PHARMACEUTICAL ANALYSIS; UHPLC;

EID: 80052014048     PISSN: 10826076     EISSN: 1520572X     Source Type: Journal    
DOI: 10.1080/10826076.2011.588058     Document Type: Article
Times cited : (11)

References (107)
  • 1
    • 34249913488 scopus 로고    scopus 로고
    • Ultrafast HPLC: Different approaches to increased throughput
    • Mann, A. C. Ultrafast HPLC: Different Approaches to Increased Throughput. LC-GC Europe 2007, 20 (5), 290-299.
    • (2007) LC-GC Europe , vol.20 , Issue.5 , pp. 290-299
    • Mann, A.C.1
  • 2
    • 78651311336 scopus 로고    scopus 로고
    • A simple approach to performance optimization in HPLC and its application in ultrafast separation development
    • Wang, X.; Carr, P. W.; Stoll, D. R.; Majors, R. A Simple Approach to Performance Optimization in HPLC and Its Application in Ultrafast Separation Development. LCGC North America 2010, 28 (11), 932-942.
    • (2010) LCGC North America , vol.28 , Issue.11 , pp. 932-942
    • Wang, X.1    Carr, P.W.2    Stoll, D.R.3    Majors, R.4
  • 3
    • 21644483417 scopus 로고    scopus 로고
    • Development of rapid analytical methods in the laboratory of pharmaceutical analytical chemistry (LCAP)
    • Rudaz, S.; Geiser, L.; Guillarme, D.; Veuthey, J. L. Development of Rapid Analytical Methods in the Laboratory of Pharmaceutical Analytical Chemistry (LCAP). Chimia 2005, 59 (6), 303-307.
    • (2005) Chimia , vol.59 , Issue.6 , pp. 303-307
    • Rudaz, S.1    Geiser, L.2    Guillarme, D.3    Veuthey, J.L.4
  • 4
    • 77954258409 scopus 로고    scopus 로고
    • Application of very-high pressure liquid chromatography for developing fast and more efficient separations within pharmaceutical development
    • Kleintop, B. L.; Wang, Q. Application of Very-High Pressure Liquid Chromatography for Developing Fast and More Efficient Separations Within Pharmaceutical Development. Amer. Pharm. Rev. 2010, 13 (4), 62-67.
    • (2010) Amer. Pharm. Rev. , vol.13 , Issue.4 , pp. 62-67
    • Kleintop, B.L.1    Wang, Q.2
  • 5
    • 21144455850 scopus 로고    scopus 로고
    • New frontiers in chromatography
    • Swartz, M. E.; Murphy, B. New Frontiers in Chromatography. Amer. Lab. 2005, 37 (3), 22-27.
    • (2005) Amer. Lab. , vol.37 , Issue.3 , pp. 22-27
    • Swartz, M.E.1    Murphy, B.2
  • 6
    • 57349087726 scopus 로고    scopus 로고
    • Fast UHPLC using sub-2 mm particles and elevated pressures for pharmaceutical process development
    • Wu, N.; Clausen, A.; Wright, L.; Vogel, K. Bernardoni, F. Fast UHPLC Using Sub-2 mm Particles and Elevated Pressures for Pharmaceutical Process Development. Amer. Pharm. Rev. 2008, 11 (3), 24-33.
    • (2008) Amer. Pharm. Rev. , vol.11 , Issue.3 , pp. 24-33
    • Wu, N.1    Clausen, A.2    Wright, L.3    Vogel, K.4    Bernardoni, F.5
  • 7
    • 55749114578 scopus 로고    scopus 로고
    • Fast LC method development for pharmaceutical analysis using sub-2-micron particles
    • Jerkovich, A.; Markarov, A.; LoBrutto, R.; Vivilecchia, R. Fast LC Method Development for Pharmaceutical Analysis Using Sub-2-micron Particles. Amer. Pharm. Rev. 2007, 10 (6), 32-38.
    • (2007) Amer. Pharm. Rev. , vol.10 , Issue.6 , pp. 32-38
    • Jerkovich, A.1    Markarov, A.2    LoBrutto, R.3    Vivilecchia, R.4
  • 8
    • 34250196870 scopus 로고    scopus 로고
    • The role of UHPLC in pharmaceutical development
    • Chesnut, S. M.; Salisbury, J. J. The Role of UHPLC in Pharmaceutical Development. J. Sep. Sci. 2007, 30, 1183-1190.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1183-1190
    • Chesnut, S.M.1    Salisbury, J.J.2
  • 9
    • 34247230154 scopus 로고    scopus 로고
    • Recent developments in liquid chromatography-impact onqualitative andquantitative performance
    • Guillarme, D.; Nguyen, D. T. T.; Rudaz, S.; Veuthey, J. L. Recent Developments in Liquid Chromatography-Impact onQualitative andQuantitative Performance. J. Chromatogr. A 2007, 1149, 20-29.
    • (2007) J. Chromatogr. A , vol.1149 , pp. 20-29
    • Guillarme, D.1    Nguyen, D.T.T.2    Rudaz, S.3    Veuthey, J.L.4
  • 10
    • 49449100511 scopus 로고    scopus 로고
    • Enhancing productivity in the analytical laboratory through the use of ultra-fast-HPLC in preformulation/ formulation development
    • LoBrutto, R.; Makarov, A.; Jerkovich, A.; McGill, R.; Kazakevich, Y.; Vivilecchia, R. Enhancing Productivity in the Analytical Laboratory Through the Use of Ultra-fast-HPLC in Preformulation/ Formulation Development. J. Liq. Chromatogr. Relat. Technol. 2008, 31, 2253-2285.
    • (2008) J. Liq. Chromatogr. Relat. Technol. , vol.31 , pp. 2253-2285
    • LoBrutto, R.1    Makarov, A.2    Jerkovich, A.3    McGill, R.4    Kazakevich, Y.5    Vivilecchia, R.6
  • 11
    • 67651208869 scopus 로고    scopus 로고
    • Theoretical and experimental comparison of mobile phase consumption between ultra-high-performance liquid chromatography and high performance liquid chromatography
    • Chen, S.; Kord, A. Theoretical and Experimental Comparison of Mobile Phase Consumption Between Ultra-High-Performance Liquid Chromatography and High Performance Liquid Chromatography. J. Chromatogr. A 2009, 1216, 6204-6209.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 6204-6209
    • Chen, S.1    Kord, A.2
  • 12
    • 67650032931 scopus 로고    scopus 로고
    • Effects of extra-column band spreading liquid chromatography system operating pressure and column temperature on the performance of sub-2-mm porous particles
    • Fountain, K. J.; Neue, U. D.; Grumback, E. S.; Diehl, D. M. Effects of Extra-Column Band Spreading, Liquid Chromatography System Operating Pressure, and Column Temperature on the Performance of Sub-2-mm Porous Particles. J. Chromatogr. A 2009, 1216, 5979-5988.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 5979-5988
    • Fountain, K.J.1    Neue, U.D.2    Grumback, E.S.3    Diehl, D.M.4
  • 13
    • 77955735445 scopus 로고    scopus 로고
    • Emerging analytical separation techniques with high throughput potential for pharmaceutical analysis part i: Stationary phase and instrumental developments in LC. Combinatorial chem
    • Pieters, S.; Dejaegher, B.; Vander Heyden, Y. Emerging Analytical Separation Techniques with High Throughput Potential for Pharmaceutical Analysis, Part I: Stationary Phase and Instrumental Developments in LC. Combinatorial Chem. High Throughput Screening 2010, 13, 510-529.
    • (2010) High Throughput Screening , vol.13 , pp. 510-529
    • Pieters, S.1    Dejaegher, B.2    Vander Heyden, Y.3
  • 14
    • 33747775588 scopus 로고    scopus 로고
    • Evaluation of ultra-performance liquid chromatography part I: Possibilities and limitations
    • de Villiers, A.; Lestremau, F.; Szucs, R.; Gelebart, S.; David, F.; Sandra, P. Evaluation of Ultra-Performance Liquid Chromatography Part I: Possibilities and Limitations. J. Chromatogr. A 2006, 1127, 60-69.
    • (2006) J. Chromatogr. A , vol.1127 , pp. 60-69
    • De Villiers, A.1    Lestremau, F.2    Szucs, R.3    Gelebart, S.4    David, F.5    Sandra, P.6
  • 15
    • 80051995281 scopus 로고    scopus 로고
    • Recent development of ultra-high pressure liquid chromatography
    • Wu, N.; Clausen, A. Recent Development of Ultra-High Pressure Liquid Chromatography. CACS Comm. 2008, 2 (1), 15-21.
    • (2008) CACS Comm. , vol.2 , Issue.1 , pp. 15-21
    • Wu, N.1    Clausen, A.2
  • 16
    • 33748427633 scopus 로고    scopus 로고
    • Fast analysis in liquid chromatography using small particle size and high pressure
    • Nguyen, D. T. T.; Guillarme, D;. Rudaz, S.; Veuthey, J. L. Fast Analysis in Liquid Chromatography Using Small Particle Size and High Pressure. J. Sep. Sci. 2006, 29 (12), 1836-1848.
    • (2006) J. Sep. Sci. , vol.29 , Issue.12 , pp. 1836-1848
    • Nguyen, D.T.T.1    Guillarme, D.2    Rudaz, S.3    Veuthey, J.L.4
  • 18
    • 4544264740 scopus 로고    scopus 로고
    • Practical aspects of fast hplc separations for pharmaceutical process development using monolithic columns
    • Wu, N.; Dempsey, J.; Yehl, P. M.; Dovletoglou, A.; Ellison, D.; Wyvratt, J. Practical Aspects of Fast HPLC Separations for Pharmaceutical Process Development Using Monolithic Columns. Anal. Chim. Acta 2004, 523, 149-156.
    • (2004) Anal. Chim. Acta , vol.523 , pp. 149-156
    • Wu, N.1    Dempsey, J.2    Yehl, P.M.3    Dovletoglou, A.4    Ellison, D.5    Wyvratt, J.6
  • 19
    • 68349109780 scopus 로고    scopus 로고
    • Monolithic silica stationary phases in liquid chromatography
    • Ali, I.; Gaitonde, V. D.; Aboul-Enein, H. Y. Monolithic Silica Stationary Phases in Liquid Chromatography. J. Chromatogr. Sci. 2009, 47, 432-442.
    • (2009) J. Chromatogr. Sci. , vol.47 , pp. 432-442
    • Ali, I.1    Gaitonde, V.D.2    Aboul-Enein, H.Y.3
  • 20
    • 34548505248 scopus 로고    scopus 로고
    • A strategy to develop fast rp-hplc methods using monolithic silica columns
    • El Deeb, S.; Preu, L.; Watzig, H. A Strategy to Develop Fast RP-HPLC Methods Using Monolithic Silica Columns. J. Sep. Sci. 2007, 30, 1993-2001.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1993-2001
    • El Deeb, S.1    Preu, L.2    Watzig, H.3
  • 21
    • 50949166646 scopus 로고    scopus 로고
    • Structure and performance of silica-based monolithic HPLC columns
    • Altmaier, S.; Cabrera, K. Structure and Performance of Silica-Based Monolithic HPLC Columns. J. Sep. Sci. 2008, 31, 2551-2559.
    • (2008) J. Sep. Sci. , vol.31 , pp. 2551-2559
    • Altmaier, S.1    Cabrera, K.2
  • 22
  • 23
    • 70549100124 scopus 로고    scopus 로고
    • Fused-core sub-2 mm packings, and monolithic HPLC columns: A comparative evaluation
    • Brice, R. W.; Zhang, X.; Colon, L. A. Fused-Core, Sub-2 mm Packings, and Monolithic HPLC Columns: A Comparative Evaluation. J. Sep. Sci. 2009, 32, 2723-2731.
    • (2009) J. Sep. Sci. , vol.32 , pp. 2723-2731
    • Brice, R.W.1    Zhang, X.2    Colon, L.A.3
  • 24
    • 0038064340 scopus 로고    scopus 로고
    • Fast separations on monolithic silica columns: Method transfer robustness and column ageing for some case studies
    • van Nederkassel, A. M.; Aerts, A.; Dierick, A.; Massart, D. L.; Vander Heyden, Y. Fast Separations on Monolithic Silica Columns: Method Transfer, Robustness and Column Ageing for Some Case Studies. J. Pharm. Biomed. Anal. 2003, 32, 233-249.
    • (2003) J. Pharm. Biomed. Anal. , vol.32 , pp. 233-249
    • Van Nederkassel, A.M.1    Aerts, A.2    Dierick, A.3    Massart, D.L.4    Vander Heyden, Y.5
  • 25
    • 80052006578 scopus 로고    scopus 로고
    • Ascentis1 express: A fused-coreTM particle HPLC column for high speed and high efficiency separations with low back pressures. LCGC North America 2007
    • Way, W. K.; Campbell, W. Ascentis1 Express: A Fused-CoreTM Particle HPLC Column for High Speed and High Efficiency Separations with Low Back Pressures. LCGC North America 2007, Appl. Note. Suppl., 55.
    • Appl. Note. Suppl. , vol.55
    • Way, W.K.1    Campbell, W.2
  • 26
    • 40449103315 scopus 로고    scopus 로고
    • Characteristics of superficially-porous silica particles for fast HPLC: Some performance comparisons with sub-2-mm particles
    • DeStefano, J. J.; Langlois, T. J.; Kirkland, J. J. Characteristics of Superficially-porous Silica Particles for Fast HPLC: Some Performance Comparisons with Sub-2-mm Particles. J. Chromatogr. Sci. 2008, 46, 254-260.
    • (2008) J. Chromatogr. Sci. , vol.46 , pp. 254-260
    • DeStefano, J.J.1    Langlois, T.J.2    Kirkland, J.J.3
  • 27
    • 77951205929 scopus 로고    scopus 로고
    • Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments
    • Gritti, F.; Sanchez, C. A.; Farkas, T.; Guiochon, G. Achieving the Full Performance of Highly Efficient Columns by Optimizing Conventional Benchmark High-Performance Liquid Chromatography Instruments. J. Chromatogr. A 2010, 1217, 3000-3012.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3000-3012
    • Gritti, F.1    Sanchez, C.A.2    Farkas, T.3    Guiochon, G.4
  • 28
    • 77953476888 scopus 로고    scopus 로고
    • New trends in fast and high-resolution liquid chromatography: A critical comparison of existing approaches
    • Guillarme, D.; Ruta, J.; Rudaz, S.; Veuthey, J. L. New Trends in Fast and High-Resolution Liquid Chromatography: A Critical Comparison of Existing Approaches. Anal. Bioanal. Chem. 2010, 397, 1069-1082.
    • (2010) Anal. Bioanal. Chem. , vol.397 , pp. 1069-1082
    • Guillarme, D.1    Ruta, J.2    Rudaz, S.3    Veuthey, J.L.4
  • 29
    • 34250203418 scopus 로고
    • High-performance liquid chromatography at elevated temperatures: Examination of conditions for the rapid separation of large molecules
    • Antia, F. D.; Horvath, C. High-Performance Liquid Chromatography at Elevated Temperatures: Examination of Conditions for the Rapid Separation of Large Molecules. J. Chromatogr. 1988, 435, 1-15.
    • (1988) J. Chromatogr. , vol.435 , pp. 1-15
    • Antia, F.D.1    Horvath, C.2
  • 30
    • 33747877146 scopus 로고    scopus 로고
    • Advances in HPLC technology for the determination of drug impurities
    • Olsen, B. A.; Castle, B. C.; Myers, D. P. Advances in HPLC Technology for the Determination of Drug Impurities. Trends Anal. Chem. 2006, 25 (8), 796-805.
    • (2006) Trends Anal. Chem. , vol.25 , Issue.8 , pp. 796-805
    • Olsen, B.A.1    Castle, B.C.2    Myers, D.P.3
  • 31
    • 33748435941 scopus 로고    scopus 로고
    • Elevated temperature and temperature programming in conventional liquid chromatography - fundamentals and applications
    • Vanhoenacker, G.; Sandra, P. Elevated Temperature and Temperature Programming in Conventional Liquid Chromatography - Fundamentals and Applications. J. Sep. Sci. 2006, 29, 1822-1835.
    • (2006) J. Sep. Sci. , vol.29 , pp. 1822-1835
    • Vanhoenacker, G.1    Sandra, P.2
  • 33
    • 11444269089 scopus 로고    scopus 로고
    • The use of micron-sized particles in ultrahigh pressure liquid chromatography
    • Jerkovich, A. D.; Mellors, J. S.; Jorgenson, J. W. The Use of Micron-Sized Particles in Ultrahigh Pressure Liquid Chromatography. LC-GC Europe 2003, 16 (6a), 20-23.
    • (2003) LC-GC Europe , vol.16 , Issue.6 A , pp. 20-23
    • Jerkovich, A.D.1    Mellors, J.S.2    Jorgenson, J.W.3
  • 34
    • 34248573460 scopus 로고    scopus 로고
    • Method transfer for fast liquid chromatography in pharmaceutical analysis. applications to short columns packed with small particle. Part I: Isocratic separation
    • Guillarme, D.; Nguyen, D. T. T.; Rudaz, S.; Veuthey, J. L. Method Transfer for Fast Liquid Chromatography in Pharmaceutical Analysis. Applications to Short Columns Packed with Small Particle, Part I: Isocratic Separation. Eur. J. Pharm. Sci. 2007, 66, 475-482.
    • (2007) Eur. J. Pharm. Sci. , vol.66 , pp. 475-482
    • Guillarme, D.1    Nguyen, D.T.T.2    Rudaz, S.3    Veuthey, J.L.4
  • 35
    • 37849007036 scopus 로고    scopus 로고
    • Method transfer for fast liquid chromatography in pharmaceutical analysis, applications to short columns packed with small particle, Part II: Gradient experiments
    • Guillarme, D.; Nguyen, D. T. T.; Rudaz, S.; Veuthey, J. L. Method Transfer for Fast Liquid Chromatography in Pharmaceutical Analysis, Applications to Short Columns Packed with Small Particle, Part II: Gradient Experiments. Eur. J. Pharm. Biopharm. 2008, 68, 430-440.
    • (2008) Eur. J. Pharm. Biopharm. , vol.68 , pp. 430-440
    • Guillarme, D.1    Nguyen, D.T.T.2    Rudaz, S.3    Veuthey, J.L.4
  • 36
    • 33751418734 scopus 로고    scopus 로고
    • Improving LC separations: Transferring methods from HPLC to UPLC
    • Grumback, E.; Wheat, T.; McCabe, D.; Diehl, D.; Mazzeo, J. Improving LC Separations: Transferring Methods from HPLC to UPLC. LCGC North America 2006, Suppl., 80-81.
    • (2006) LCGC North America , Issue.SUPPL. , pp. 80-81
    • Grumback, E.1    Wheat, T.2    McCabe, D.3    Diehl, D.4    Mazzeo, J.5
  • 37
    • 61349167775 scopus 로고    scopus 로고
    • Transferring methods from conventional HPLC to fast liquid chromatography: A practical perspective using narrow-bore columns with sub-2 mm particles
    • Ringling, J.; Wood, C.; Borjas, R.; Foti, C. Transferring Methods from Conventional HPLC to Fast Liquid Chromatography: A Practical Perspective Using Narrow-Bore Columns with Sub-2 mm Particles. Amer. Pharm. Rev. 2008, 11 (7), 24-32.
    • (2008) Amer. Pharm. Rev. , vol.11 , Issue.7 , pp. 24-32
    • Ringling, J.1    Wood, C.2    Borjas, R.3    Foti, C.4
  • 38
    • 43249115914 scopus 로고    scopus 로고
    • Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets
    • Nguyen, D. T. T.; Guillarme, D.; Rudaz, S.; Veuthey, J. L. Validation of an Ultra-fast UPLC-UV Method for the Separation of Antituberculosis Tablets. J. Sep. Sci. 2008, 31, 1050-1056.
    • (2008) J. Sep. Sci. , vol.31 , pp. 1050-1056
    • Nguyen, D.T.T.1    Guillarme, D.2    Rudaz, S.3    Veuthey, J.L.4
  • 39
    • 37849000570 scopus 로고    scopus 로고
    • Development and validation of UPLC method for determination of primaquine phosphate and its impurities
    • Dongre, V. G.; Karmuse, P. P.; Prakasa Rao, P.; Kumar, A. Development and Validation of UPLC Method for Determination of Primaquine Phosphate and Its Impurities. J. Biomed. Pharm. Anal. 2008, 46, 236-242.
    • (2008) J. Biomed. Pharm. Anal. , vol.46 , pp. 236-242
    • Dongre, V.G.1    Karmuse, P.P.2    Prakasa Rao, P.3    Kumar, A.4
  • 40
    • 57749110389 scopus 로고    scopus 로고
    • Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and its impurities in pharmaceutical formulation
    • Dalvi, P. N. Comparison of Conventional HPLC with UPLC Method for Determination of Albuterol Sulfate and Its Impurities in Pharmaceutical Formulation. Orient. J. Chem. 2008, 24 (2), 537-544.
    • (2008) Orient. J. Chem. , vol.24 , Issue.2 , pp. 537-544
    • Dalvi, P.N.1
  • 41
    • 79952934020 scopus 로고    scopus 로고
    • Development and validation of stability indicating UPLC method for the simultaneous determination of beta-blockers and diuretic drugs in pharmaceutical dosage forms
    • Narasimham, Y. S.; Barhate, V. D. Development and Validation of Stability Indicating UPLC Method for the Simultaneous Determination of Beta-blockers and Diuretic Drugs in Pharmaceutical Dosage Forms. J. Chem. Metrol. 2010, 4 (1), 1-20.
    • (2010) J. Chem. Metrol. , vol.4 , Issue.1 , pp. 1-20
    • Narasimham, Y.S.1    Barhate, V.D.2
  • 43
    • 77954862332 scopus 로고    scopus 로고
    • Stability-indicating UPLC method for determination of valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms
    • Krishnaiah, C.; Reddy, A. R.; Kumar, R.; Mukkanti, K. Stability-indicating UPLC Method for Determination of Valsartan and Their Degradation Products in Active Pharmaceutical Ingredient and Pharmaceutical Dosage Forms. J. Pharm. Biomed. Anal. 2010, 53, 483-489.
    • (2010) J. Pharm. Biomed. Anal. , vol.53 , pp. 483-489
    • Krishnaiah, C.1    Reddy, A.R.2    Kumar, R.3    Mukkanti, K.4
  • 44
    • 77955497808 scopus 로고    scopus 로고
    • A single reverse-phase UPLC method for quantification of levofloxacin in aqueous humor and pharmaceutical dosage forms
    • Gupta, H.; Aqil, M.; Khar, R. K.; Ali, A.; Chander, P. A Single Reverse-Phase UPLC Method for Quantification of Levofloxacin in Aqueous Humor and Pharmaceutical Dosage Forms. J. Chromatogr. Sci. 2010, 48, 484-490.
    • (2010) J. Chromatogr. Sci. , vol.48 , pp. 484-490
    • Gupta, H.1    Aqil, M.2    Khar, R.K.3    Ali, A.4    Chander, P.5
  • 45
    • 80051973970 scopus 로고    scopus 로고
    • Rapid and sensitive RP-Ultra Performance Liquid Chromatography (UPLC) method for estimation and validation of paclitaxel in bulk and its injection dosage form
    • Saini, P. K.; Jain, C. L.; Singh, R. M.; Mathur, S. C.; Singh, G. N. Rapid and Sensitive RP-Ultra Performance Liquid Chromatography (UPLC) Method for Estimation and Validation of Paclitaxel in Bulk and Its Injection Dosage Form. Pharmbit. 2009, XX (2), 143-147.
    • (2009) Pharmbit. , vol.10 , Issue.2 , pp. 143-147
    • Saini, P.K.1    Jain, C.L.2    Singh, R.M.3    Mathur, S.C.4    Singh, G.N.5
  • 46
    • 80051971055 scopus 로고    scopus 로고
    • A rapid and sensitive RP-UPLC method for simultaneous determination of zidovudine lamivudine and nevirapine in tablet dosage form
    • Saini, P. K.; Singh, R. M.; Mathur, S. C.; Singh, G. N. A Rapid and Sensitive RP-UPLC Method for Simultaneous Determination of Zidovudine, Lamivudine and Nevirapine in Tablet Dosage Form. J. Pharm. Res. 2010, 9 (2), 56-59.
    • (2010) J. Pharm. Res. , vol.9 , Issue.2 , pp. 56-59
    • Saini, P.K.1    Singh, R.M.2    Mathur, S.C.3    Singh, G.N.4
  • 47
    • 80051989722 scopus 로고    scopus 로고
    • Development and validation of stability indicating ultra-performance liquid chromatographic method for riluzole
    • Ahamed, A.; Krishnamurthy, G.; Reddy, M.; Ramesha, S.; Naik, H. S. B.; Charitha, J. G. Development and Validation of Stability Indicating Ultra-Performance Liquid Chromatographic Method for Riluzole. J. Pharmacy Res. 2010, 3 (5), 1028-1033.
    • (2010) J. Pharmacy Res. , vol.3 , Issue.5 , pp. 1028-1033
    • Ahamed, A.1    Krishnamurthy, G.2    Reddy, M.3    Ramesha, S.4    Naik, H.S.B.5    Charitha, J.G.6
  • 48
    • 77957203518 scopus 로고    scopus 로고
    • Development and validation of ropinirole hydrochloride and its related compounds by uplc in api and pharmaceutical dosage forms
    • Krishnaiah, C.; Vishnumurthy, M.; Reddy, A. R.; Kumar, R.; Mukkanti, K. Development and Validation of Ropinirole Hydrochloride and Its Related Compounds by UPLC in API and Pharmaceutical Dosage Forms. J. Chinese Chem. Soc. 2010, 57, 348-355.
    • (2010) J. Chinese Chem. Soc. , vol.57 , pp. 348-355
    • Krishnaiah, C.1    Vishnumurthy, M.2    Reddy, A.R.3    Kumar, R.4    Mukkanti, K.5
  • 49
    • 30144444985 scopus 로고    scopus 로고
    • Advantages of application of UPLC in pharmaceutical analysis
    • Novakova, L.; Matysova, L.; Solich, P. Advantages of Application of UPLC in Pharmaceutical Analysis. Talanta 2006, 68, 908-918.
    • (2006) Talanta , vol.68 , pp. 908-918
    • Novakova, L.1    Matysova, L.2    Solich, P.3
  • 50
    • 33751301991 scopus 로고    scopus 로고
    • Advantages of ultra-performance liquid chromatography over high-performance liquid chromatography: Comparison of different analytical approaches during analysis of diclofenac gel
    • Novakova, L.; Solichova, D.; Solich, P. Advantages of Ultra-Performance Liquid Chromatography Over High-Performance Liquid Chromatography: Comparison of Different Analytical Approaches During Analysis of Diclofenac Gel. J. Sep. Sci. 2006, 29, 2433-2443.
    • (2006) J. Sep. Sci. , vol.29 , pp. 2433-2443
    • Novakova, L.1    Solichova, D.2    Solich, P.3
  • 51
    • 75849149182 scopus 로고    scopus 로고
    • Fast chiral separation of drugs using columns packed with sub-2-mm particles and ultra-high pressure
    • Guillarme, D.; Bonvin, G.; Badoud, F.; Shappler, J.; Rudaz, S.; Veuthey, J. L. Fast Chiral Separation of Drugs Using Columns Packed with Sub-2-mm Particles and Ultra-High Pressure. Chirality 2010, 22, 320-330.
    • (2010) Chirality , vol.22 , pp. 320-330
    • Guillarme, D.1    Bonvin, G.2    Badoud, F.3    Shappler, J.4    Rudaz, S.5    Veuthey, J.L.6
  • 52
    • 4344595737 scopus 로고    scopus 로고
    • Applications of silica-based monolithic HPLC columns
    • Cabrera, K. Applications of Silica-Based Monolithic HPLC Columns. J. Sep. Sci. 2004, 27 (10-11), 843-852.
    • (2004) J. Sep. Sci. , vol.27 , Issue.10-11 , pp. 843-852
    • Cabrera, K.1
  • 53
    • 0037172868 scopus 로고    scopus 로고
    • Repeatability and reproducibility of retention data and band profiles on six batches of monolithic columns
    • Kele, M.; Guichon, G. Repeatability and Reproducibility of Retention Data and Band Profiles on Six Batches of Monolithic Columns. J. Chromatogr. A 2002, 960 (1-2), 19-49.
    • (2002) J. Chromatogr. A , vol.960 , Issue.1-2 , pp. 19-49
    • Kele, M.1    Guichon, G.2
  • 54
    • 77952100911 scopus 로고    scopus 로고
    • Rapid determination of methylxanthines in real samples by high-performance liquid chromatography using new fastgradient1 narrow-bore monolithic column
    • Tzanavaras, P. D.; Zacharis, C. K.; Themelis, D. G. Rapid Determination of Methylxanthines in Real Samples by High-Performance Liquid Chromatography Using New FastGradient1 Narrow-Bore Monolithic Column. Talanta 2010, 81 (4-5), 1494-1501.
    • (2010) Talanta , vol.81 , Issue.4-5 , pp. 1494-1501
    • Tzanavaras, P.D.1    Zacharis, C.K.2    Themelis, D.G.3
  • 55
    • 70350503783 scopus 로고    scopus 로고
    • Application of monolithic columns in pharmaceutical analysis determination of indomethacin and its degradation products
    • Zakova, P.; Sklenarova, H.; Novakova, L.; Hajkova, R.; Matysova, L.; Solich, P. Application of Monolithic Columns in Pharmaceutical Analysis, Determination of Indomethacin and Its Degradation Products. J. Sep. Sci. 2009, 32, 2786-2792.
    • (2009) J. Sep. Sci. , vol.32 , pp. 2786-2792
    • Zakova, P.1    Sklenarova, H.2    Novakova, L.3    Hajkova, R.4    Matysova, L.5    Solich, P.6
  • 56
    • 14544271036 scopus 로고    scopus 로고
    • Practical applications of monolithic columns to pharmaceutical process development
    • Liu, Y.; Antonucci, V.; Shen, Y.; Vailaya, A.; Wu, N. Practical Applications of Monolithic Columns to Pharmaceutical Process Development. J. Liq. Chromatogr. Relat. Technol. 2005, 28, 341-356.
    • (2005) J. Liq. Chromatogr. Relat. Technol. , vol.28 , pp. 341-356
    • Liu, Y.1    Antonucci, V.2    Shen, Y.3    Vailaya, A.4    Wu, N.5
  • 57
    • 33646841485 scopus 로고    scopus 로고
    • Development of an ion-pair liquid chromatographic method for determination of sotalol in plasma using a monolithic column
    • Zarghi, A.; Foroutan, S. M.; Shafaati, A.; Khoddam, A. Development of an Ion-Pair Liquid Chromatographic Method for Determination of Sotalol in Plasma Using a Monolithic Column. J. Pharm. Biomed. Anal. 2006, 41, 1433-1437.
    • (2006) J. Pharm. Biomed. Anal. , vol.41 , pp. 1433-1437
    • Zarghi, A.1    Foroutan, S.M.2    Shafaati, A.3    Khoddam, A.4
  • 58
    • 67650248278 scopus 로고    scopus 로고
    • Rapid and sensitive simultaneous determination of ezetimibe and simvastatin from their combination drug products by monolithic silica high-performance liquid chromatographic column
    • Hefnawy, M.; Al-Omar, M.; Julkhuf, S. Rapid and Sensitive Simultaneous Determination of Ezetimibe and Simvastatin from Their Combination Drug Products by Monolithic Silica High-Performance Liquid Chromatographic Column. J. Pharm. Biomed. Anal. 2009, 50, 527-534.
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 527-534
    • Hefnawy, M.1    Al-Omar, M.2    Julkhuf, S.3
  • 60
    • 33847096017 scopus 로고    scopus 로고
    • Validated high-throughput hplc assay for nimesulide using a short monolithic column
    • Tzanavaras, P. D.; Themelis, D. G. Validated High-Throughput HPLC Assay for Nimesulide Using a Short Monolithic Column. J. Pharm. Biomed. Anal. 2007, 43, 1483-1487.
    • (2007) J. Pharm. Biomed. Anal. , vol.43 , pp. 1483-1487
    • Tzanavaras, P.D.1    Themelis, D.G.2
  • 61
    • 39149098448 scopus 로고    scopus 로고
    • Optimization and validation of a dissolution test for selegiline hydrochloride tablets by a novel rapid HPLC assay using a monolithic stationary phase
    • Tzanavaras, P. D.; Themelis, D. G.; Zotou, A.; Stratis, J.; Karlberg, B. Optimization and Validation of a Dissolution Test for Selegiline Hydrochloride Tablets by a Novel Rapid HPLC Assay Using a Monolithic Stationary Phase. J. Pharm. Biomed. Anal. 2008, 46, 670-675.
    • (2008) J. Pharm. Biomed. Anal. , vol.46 , pp. 670-675
    • Tzanavaras, P.D.1    Themelis, D.G.2    Zotou, A.3    Stratis, J.4    Karlberg, B.5
  • 62
    • 14644397918 scopus 로고    scopus 로고
    • Chromatographic applications on monolithic columns: Determination of triamcinolone prednisolone and dexamethasone in pharmaceutical tablet formulations using solid state extraction and a monolith column
    • Hashem, H.; Jira, T. Chromatographic Applications on Monolithic Columns: Determination of Triamcinolone, Prednisolone and Dexamethasone in Pharmaceutical Tablet Formulations Using Solid State Extraction and a Monolith Column. Chromatographia 2005, 61 (3-4), 133-136.
    • (2005) Chromatographia , vol.61 , Issue.3-4 , pp. 133-136
    • Hashem, H.1    Jira, T.2
  • 63
    • 33748570155 scopus 로고    scopus 로고
    • Application of monolithic column in quantification of gliclazide in human plasma by liquid chromatography
    • Foroutan, S. M.; Zarghi, A.; Shafaati, A.; Khoddam, A. Application of Monolithic Column in Quantification of Gliclazide in Human Plasma by Liquid Chromatography. J. Pharm. Biomed. Anal. 2006, 42, 513-516.
    • (2006) J. Pharm. Biomed. Anal. , vol.42 , pp. 513-516
    • Foroutan, S.M.1    Zarghi, A.2    Shafaati, A.3    Khoddam, A.4
  • 64
    • 8844234259 scopus 로고    scopus 로고
    • Comparison of performance of c18 monolithic rod columns and conventional c18 particle-packed columns in liquid chromatographic determination of estrogel and ketoprofen gel
    • Novakova, L.; Matysova, L.; Solichova, D.; Koupparis, M. A.; Solich, P. Comparison of Performance of C18 Monolithic Rod Columns and Conventional C18 Particle-Packed Columns in Liquid Chromatographic Determination of Estrogel and Ketoprofen Gel. J. Chromatogr. B 2004, 813, 191-197.
    • (2004) J. Chromatogr. B , vol.813 , pp. 191-197
    • Novakova, L.1    Matysova, L.2    Solichova, D.3    Koupparis, M.A.4    Solich, P.5
  • 65
    • 37749043688 scopus 로고    scopus 로고
    • HPLC determination of rifampicin and related compounds in pharmaceuticals using monolithic column
    • Liu, J.; Sun, J.; Zhang, W.; Gao, K.; He, Z. HPLC Determination of Rifampicin and Related Compounds in Pharmaceuticals Using Monolithic Column. J. Pharm. Biomed. Anal. 2008, 46, 405-409.
    • (2008) J. Pharm. Biomed. Anal. , vol.46 , pp. 405-409
    • Liu, J.1    Sun, J.2    Zhang, W.3    Gao, K.4    He, Z.5
  • 66
    • 5644275539 scopus 로고    scopus 로고
    • Fast separation of bacitracin on monolithic silica columns
    • Pavli, V.; Kmetec, V. Fast Separation of Bacitracin on Monolithic Silica Columns. J. Pharm. Biomed. Anal. 2004, 36, 257-264.
    • (2004) J. Pharm. Biomed. Anal. , vol.36 , pp. 257-264
    • Pavli, V.1    Kmetec, V.2
  • 67
    • 33746886184 scopus 로고    scopus 로고
    • Fast HPLC method for the determination of glimepiride glibenclamide, and related substances using monolithic column and flow program
    • El Deeb, S.; Schepers, U.; Watzig, H. Fast HPLC Method for the Determination of Glimepiride, Glibenclamide, and Related Substances Using Monolithic Column and Flow Program. J. Sep. Sci. 2006, 29, 1571-1577.
    • (2006) J. Sep. Sci. , vol.29 , pp. 1571-1577
    • El Deeb, S.1    Schepers, U.2    Watzig, H.3
  • 68
    • 33644761838 scopus 로고    scopus 로고
    • Fast and reliable determination of the antifungal drug voriconazole in plasma using monolith silica rod liquid chromatography
    • Wenk, M.; Droll, A.; Krahenbuhl, S. Fast and Reliable Determination of the Antifungal Drug Voriconazole in Plasma Using Monolith Silica Rod Liquid Chromatography. J. Liq. Chromatogr. B 2006, 832, 313-316.
    • (2006) J. Liq. Chromatogr. B , vol.832 , pp. 313-316
    • Wenk, M.1    Droll, A.2    Krahenbuhl, S.3
  • 69
    • 70349655378 scopus 로고    scopus 로고
    • Validated optimized method for simultaneous analysis of active silymarin components and dimethyl-4-40-dimethoxy-5 6 50,60-dimethylene dioxybiphenyl- 2-20-dicarboxylate in a pharmaceutical preparation by use of a monolithic silica C18 column
    • Hadad, G. M.; Emara, S.; Abdel-Salam, R. A. Validated Optimized Method for Simultaneous Analysis of Active Silymarin Components and Dimethyl-4-40-dimethoxy-5,6,50,60-dimethylene Dioxybiphenyl- 2-20-dicarboxylate in a Pharmaceutical Preparation by Use of a Monolithic Silica C18 Column. Chromatographia 2009, 70, 217-221.
    • (2009) Chromatographia , vol.70 , pp. 217-221
    • Hadad, G.M.1    Emara, S.2    Abdel-Salam, R.A.3
  • 70
    • 18444382085 scopus 로고    scopus 로고
    • Reversed phase liquid chromatographic method for the high-throughput analysis of clopidogrel in pharmaceutical formulations using a monolithic silica column
    • Aboul-Enein, H. Y.; Hoenen, H.; Ghanem, A.; Koll, M. Reversed Phase Liquid Chromatographic Method for the High-Throughput Analysis of Clopidogrel in Pharmaceutical Formulations Using a Monolithic Silica Column. J. Liq. Chromatogr. Relat. Technol. 2005, 28, 1357-1365.
    • (2005) J. Liq. Chromatogr. Relat. Technol. , vol.28 , pp. 1357-1365
    • Aboul-Enein, H.Y.1    Hoenen, H.2    Ghanem, A.3    Koll, M.4
  • 71
    • 33646948952 scopus 로고    scopus 로고
    • Determination of zonisamide by a coated monolithic column
    • Li, Z.; Wu, G.; Zhu, Y. Determination of Zonisamide by a Coated Monolithic Column. J. Chromatogr. A 2006, 1118, 151-154.
    • (2006) J. Chromatogr. A , vol.1118 , pp. 151-154
    • Li, Z.1    Wu, G.2    Zhu, Y.3
  • 72
    • 77956923271 scopus 로고    scopus 로고
    • Fast RPLC analysis of pharmaceutical compounds at intermediate temperatures by using a conventional instrument
    • Gotta, J.; Osorio Grisales, J.; Reta, M. R.; Castells, C. B. Fast RPLC Analysis of Pharmaceutical Compounds at Intermediate Temperatures by Using a Conventional Instrument. J. Sep. Sci. 2010, 33, 2645-2653.
    • (2010) J. Sep. Sci. , vol.33 , pp. 2645-2653
    • Gotta, J.1    Osorio Grisales, J.2    Reta, M.R.3    Castells, C.B.4
  • 73
    • 34047259507 scopus 로고    scopus 로고
    • Evaluation of monolithic HPLC columns for various pharmaceutical separations: Method transfer from conventional phases and batch to batch repeatability
    • El Deeb, S.; Preu, L.; Watzig, H. Evaluation of Monolithic HPLC Columns for Various Pharmaceutical Separations: Method Transfer from Conventional Phases and Batch to Batch Repeatability. J. Pharm. Biomed. Anal. 2007, 44, 85-95.
    • (2007) J. Pharm. Biomed. Anal. , vol.44 , pp. 85-95
    • El Deeb, S.1    Preu, L.2    Watzig, H.3
  • 74
    • 70350496614 scopus 로고    scopus 로고
    • Automated zone-sampling dilution by coupling sequential injection analysis to high-throughput HPLC for the direct determination of gemfibrozil
    • Tzanavaras, P. D.; Themelis, D. G.; Rigas, P. Automated Zone-Sampling Dilution by Coupling Sequential Injection Analysis to High-Throughput HPLC for the Direct Determination of Gemfibrozil. J. Sep. Sci. 2009, 32, 2819-2826.
    • (2009) J. Sep. Sci. , vol.32 , pp. 2819-2826
    • Tzanavaras, P.D.1    Themelis, D.G.2    Rigas, P.3
  • 75
    • 77952100911 scopus 로고    scopus 로고
    • Rapid determination of methylxanthines in real samples by high-performance liquid chromatography using new fastgradient1 narrow-bore monolithic column
    • Tzanavaras, P. D.; Zacharis, C. K.; Themelis, D. G. Rapid Determination of Methylxanthines in Real Samples By High-Performance Liquid Chromatography Using New Fastgradient1 Narrow-Bore Monolithic Column. Talanta 2010, 81, 1494-1501.
    • (2010) Talanta , vol.81 , pp. 1494-1501
    • Tzanavaras, P.D.1    Zacharis, C.K.2    Themelis, D.G.3
  • 76
    • 37848999751 scopus 로고    scopus 로고
    • Fused-core particle technology as an alternative to sub-2-mm particles to achieve high separation efficiency with low backpressure
    • Cunliffe, J. M.; Maloney, T. D. Fused-Core Particle Technology as an Alternative to Sub-2-mm Particles to Achieve High Separation Efficiency with Low Backpressure. J. Sep. Sci. 2007, 30, 3104-3109.
    • (2007) J. Sep. Sci. , vol.30 , pp. 3104-3109
    • Cunliffe, J.M.1    Maloney, T.D.2
  • 77
    • 56549122608 scopus 로고    scopus 로고
    • Fused-core particles: A practical alternative to sub-2 micron particles
    • Salisbury, J. J. Fused-Core Particles: A Practical Alternative to Sub-2 Micron Particles. J. Chromatogr. Sci. 2008, 46, 883-886.
    • (2008) J. Chromatogr. Sci. , vol.46 , pp. 883-886
    • Salisbury, J.J.1
  • 78
    • 70349319343 scopus 로고    scopus 로고
    • Practical comparison of 2.7 mm fused-core silica particles and porous sub-2 mm particles for fast separations in pharmaceutical process development
    • Abrahim, A.; Al-Sayah, M.; Skrdla, P.; Bereznitski, Y.; Chen, Y.; Wu, N. Practical Comparison of 2.7 mm Fused-Core Silica Particles and Porous Sub-2 mm Particles for Fast Separations in Pharmaceutical Process Development. J. Pharm. Biomed. Anal. 2010, 51, 131-137.
    • (2010) J. Pharm. Biomed. Anal. , vol.51 , pp. 131-137
    • Abrahim, A.1    Al-Sayah, M.2    Skrdla, P.3    Bereznitski, Y.4    Chen, Y.5    Wu, N.6
  • 79
    • 70349178658 scopus 로고    scopus 로고
    • Comparison study of porous fused-core, and monolithic silica-based C18 HPLC columns for celestoderm-v ointment1 analysis
    • Zheng, J.; Patel, D.; Tang, Q.; Markovich, R. J.; Rustum, A. M. Comparison Study of Porous, Fused-Core, and Monolithic Silica-Based C18 HPLC Columns for Celestoderm-v Ointment1 Analysis. J. Pharm. Biomed. Anal. 2009, 50, 815-822.
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 815-822
    • Zheng, J.1    Patel, D.2    Tang, Q.3    Markovich, R.J.4    Rustum, A.M.5
  • 80
    • 72149119460 scopus 로고    scopus 로고
    • Optimization and validation of a high performance liquid chromatography method for rapid determination of sinafloxacin, a novel fluoroquinolone in rat plasma using a fused-core C18-silica column
    • Wang, S.; Wen, J.; Cui, L.; Zhang, X.; Wei, H.; Xie, R.; Feng, B.; Wu, Y.; Fan, G. Optimization and Validation of a High Performance Liquid Chromatography Method for Rapid Determination of Sinafloxacin, a Novel Fluoroquinolone in Rat Plasma Using a Fused-Core C18-silica Column. J. Pharm. Biomed. Anal. 2010, 51, 889-893.
    • (2010) J. Pharm. Biomed. Anal. , vol.51 , pp. 889-893
    • Wang, S.1    Wen, J.2    Cui, L.3    Zhang, X.4    Wei, H.5    Xie, R.6    Feng, B.7    Wu, Y.8    Fan, G.9
  • 81
    • 34547743751 scopus 로고    scopus 로고
    • Fused-core silica column high-performance liquid chromatography/tandem mass spectrometric determination of rimonabant in mouse plasma
    • Hsieh, Y.; Duncan, C. J. G.; Brisson, J. M. Fused-Core Silica Column High-Performance Liquid Chromatography/Tandem Mass Spectrometric Determination of Rimonabant in Mouse Plasma. Anal. Chem. 2007, 79, 5668-5673.
    • (2007) Anal. Chem. , vol.79 , pp. 5668-5673
    • Hsieh, Y.1    Duncan, C.J.G.2    Brisson, J.M.3
  • 82
    • 74149084551 scopus 로고    scopus 로고
    • Stability indicating fast lc for the simultaneous estimation of intermediates and degradants of duloxetine hydrochloride
    • Rudra Mohan Reddy, P.; Sreeramulu, J.; Naidu, P. Y.; Rajasekhara Reddy, A. Stability Indicating Fast LC for the Simultaneous Estimation of Intermediates and Degradants of Duloxetine Hydrochloride. Chromatographia 2010, 71, 95-100.
    • (2010) Chromatographia , vol.71 , pp. 95-100
    • Rudra Mohan Reddy, P.1    Sreeramulu, J.2    Naidu, P.Y.3    Rajasekhara Reddy, A.4
  • 83
    • 67650364379 scopus 로고    scopus 로고
    • Comparison of fused-core and conventional particle size columns by LC-MS/MS and UV: Application to pharmacokinetic study
    • Song, W.; Pabbisetty, D.; Groeber, E. A.; Steenwyk, R. C.; Fast, D. M. Comparison of Fused-Core and Conventional Particle Size Columns by LC-MS/MS and UV: Application to Pharmacokinetic Study. J. Pharm. Biomed. Anal. 2009, 50, 491-500.
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , pp. 491-500
    • Song, W.1    Pabbisetty, D.2    Groeber, E.A.3    Steenwyk, R.C.4    Fast, D.M.5
  • 84
    • 34547504080 scopus 로고    scopus 로고
    • Practice and theory of high temperature liquid chromatography
    • McNeff, C. V.; Yan, B.; Stoll, D. R.; Henry, R. A. Practice and Theory of High Temperature Liquid Chromatography. J. Sep. Sci. 2007, 30, 1672-1685.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1672-1685
    • McNeff, C.V.1    Yan, B.2    Stoll, D.R.3    Henry, R.A.4
  • 85
    • 58149105278 scopus 로고    scopus 로고
    • Sense and nonsense of high-temperature liquid chromatography
    • Heinisch, S.; Rocca, J. L. Sense and Nonsense of High-Temperature Liquid Chromatography. J. Chromatogr. A 2009, 1216, 642-658.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 642-658
    • Heinisch, S.1    Rocca, J.L.2
  • 87
    • 68749086029 scopus 로고    scopus 로고
    • High-temperature liquid chromatography. Part I: Determination of the vapor pressures of binary solvent mixtures-implications for liquid chromatographic separations
    • Teutenberg, T.; Wagner, P.; Gmehling, J. High-Temperature Liquid Chromatography, Part I: Determination of the Vapor Pressures of Binary Solvent Mixtures-Implications for Liquid Chromatographic Separations. J. Chromatogr. A 2009, 1216, 6471-6480.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 6471-6480
    • Teutenberg, T.1    Wagner, P.2    Gmehling, J.3
  • 88
    • 70350543760 scopus 로고    scopus 로고
    • High-temperature liquid chromatography. Part II: Determination of the viscosities of binary solvent mixtures-implications for liquid chromatographic separations
    • Teutenberg, T.; Wiese, S.; Wagner, P.; Gmehling, J. High-Temperature Liquid Chromatography, Part II: Determination of the Viscosities of Binary Solvent Mixtures-Implications for Liquid Chromatographic Separations. J. Chromatogr. A 2009, 1216, 8470-8479.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 8470-8479
    • Teutenberg, T.1    Wiese, S.2    Wagner, P.3    Gmehling, J.4
  • 89
    • 70350554043 scopus 로고    scopus 로고
    • High-temperature liquid chromatography. Part III: Determination of the static permittivities of pure solvents and binary solvent mixtures-implications for liquid chromatographic separations
    • Teutenberg, T.; Wiese, S.; Wagner, P.; Gmehling, J. High-temperature Liquid Chromatography, Part III: Determination of the Static Permittivities of Pure Solvents and Binary Solvent Mixtures-Implications for Liquid Chromatographic Separations. J. Chromatogr. A 2009, 1216, 8480-8487.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 8480-8487
    • Teutenberg, T.1    Wiese, S.2    Wagner, P.3    Gmehling, J.4
  • 91
    • 65549153130 scopus 로고    scopus 로고
    • Potential of high temperature liquid chromatography for the improvement of separation efficiency - A review
    • Teutenberg, T. Potential of High Temperature Liquid Chromatography for the Improvement of Separation Efficiency - A Review. Anal. Chim. Acta 2009, 643, 1-12.
    • (2009) Anal. Chim. Acta , vol.643 , pp. 1-12
    • Teutenberg, T.1
  • 92
    • 1042299052 scopus 로고    scopus 로고
    • Temperature-programmed packed capillary liquid chromatography coupled to evaporative light-scattering detection and electrospray ionization time-of-flight mass spectrometry for characterization of high-molecular-weight hindered amine light stabilities
    • Andersen, T.; Skuland, I. L.; Holm, A.; Trones, R.; Greibrokk, T. Temperature-Programmed Packed Capillary Liquid Chromatography Coupled to Evaporative Light-Scattering Detection and Electrospray Ionization Time-of-Flight Mass Spectrometry for Characterization of High-Molecular-Weight Hindered Amine Light Stabilities. J. Chromatogr. A 2004, 1029 (1-2), 49-56.
    • (2004) J. Chromatogr. A , vol.1029 , Issue.1-2 , pp. 49-56
    • Andersen, T.1    Skuland, I.L.2    Holm, A.3    Trones, R.4    Greibrokk, T.5
  • 93
    • 33751040802 scopus 로고    scopus 로고
    • Applications of high-temperature liquid chromatography (ht-lc) in a pharmaceutical setting: Challenges and accomplishments
    • Appl
    • Colon, I.; Gonzalez, J. R.; Richoll, S. M. Applications of High-Temperature Liquid Chromatography (HT-LC) in a Pharmaceutical Setting: Challenges and Accomplishments. Amer. Lab. 2006, Appl, 20-26.
    • (2006) Amer. Lab. , pp. 20-26
    • Colon, I.1    Gonzalez, J.R.2    Richoll, S.M.3
  • 94
    • 8844240708 scopus 로고    scopus 로고
    • Using high temperature HPLC for improved analysis
    • Clark, J. Using High Temperature HPLC for Improved Analysis. Pharm. Tech. Eur. 2004, 16 (5), 41-46.
    • (2004) Pharm. Tech. Eur. , vol.16 , Issue.5 , pp. 41-46
    • Clark, J.1
  • 95
    • 33751024690 scopus 로고    scopus 로고
    • Temperature-programmed HPLC
    • Clark, J. Temperature-Programmed HPLC. Today's Chemist at Work 2004, 13 (8), 43-45.
    • (2004) Today's Chemist at Work , vol.13 , Issue.8 , pp. 43-45
    • Clark, J.1
  • 96
    • 0034653626 scopus 로고    scopus 로고
    • High temperature ultrafast liquid chromatography
    • Yan, B.; Zhao, J.; Brown, J. S.; Blackwell, J.; Carr, P. High Temperature Ultrafast Liquid Chromatography. Anal. Chem. 2000, 72 (6), 1253-1262.
    • (2000) Anal. Chem. , vol.72 , Issue.6 , pp. 1253-1262
    • Yan, B.1    Zhao, J.2    Brown, J.S.3    Blackwell, J.4    Carr, P.5
  • 97
    • 0037102258 scopus 로고    scopus 로고
    • High-speed liquid chromatography by simultaneous optimization of temperature and eluent composition
    • Thompson, J. D.; Carr, P. W. High-Speed Liquid Chromatography by Simultaneous Optimization of Temperature and Eluent Composition. Anal. Chem. 2002, 74 (16), 4150-4159.
    • (2002) Anal. Chem. , vol.74 , Issue.16 , pp. 4150-4159
    • Thompson, J.D.1    Carr, P.W.2
  • 98
    • 4744367342 scopus 로고    scopus 로고
    • Effect of temperature in reversed phase liquid chromatography
    • Guillarme, D.; Heinishch, S.; Rocca, J. L. Effect of Temperature in Reversed Phase Liquid Chromatography. J. Chromatogr. A 2004, 1052 (1-2), 39-51.
    • (2004) J. Chromatogr. A , vol.1052 , Issue.1-2 , pp. 39-51
    • Guillarme, D.1    Heinishch, S.2    Rocca, J.L.3
  • 100
    • 1242338068 scopus 로고    scopus 로고
    • Effect of high-temperature on high performance liquid chromatography column stability and performance under temperature-programmed conditions
    • Marin, S. J.; Jones, B. A.; Felix, W. D.; Clark, J. Effect of High-Temperature on High Performance Liquid Chromatography Column Stability and Performance Under Temperature-Programmed Conditions. J. Chromatogr. A 2004, 1030 (1-2), 255-262.
    • (2004) J. Chromatogr. A , vol.1030 , Issue.1-2 , pp. 255-262
    • Marin, S.J.1    Jones, B.A.2    Felix, W.D.3    Clark, J.4
  • 101
    • 78149495902 scopus 로고    scopus 로고
    • A study of some practical aspects of high temperature liquid chromatography in pharmaceutical applications
    • Berta, R.; Babjak, M.; Gazdag, M. A Study of Some Practical Aspects of High Temperature Liquid Chromatography in Pharmaceutical Applications. J. Biomed. Pharm. Anal. 2011, 54, 458-462.
    • J. Biomed. Pharm. Anal. , vol.2011 , Issue.54 , pp. 458-462
    • Berta, R.1    Babjak, M.2    Gazdag, M.3
  • 102
    • 39149100939 scopus 로고    scopus 로고
    • Influence of stationary phase on the stability of thalidomide and comparison of different methods for the quantification of thalidomide in tablets using high-temperature liquid chromatography
    • Giegold, S.; Holzhauser, M.; Kiffmeyer, T.; Tuerk, J.; Teutenberg, T.; Rosenhagen, M.; Hennies, D.; Hoppe-Tichy, T.; Wenclawiak, B. Influence of Stationary Phase on the Stability of Thalidomide and Comparison of Different Methods for the Quantification of Thalidomide in Tablets Using High-Temperature Liquid Chromatography. J. Pharm. Biomed. Anal. 2008, 46, 625-630.
    • (2008) J. Pharm. Biomed. Anal. , vol.46 , pp. 625-630
    • Giegold, S.1    Holzhauser, M.2    Kiffmeyer, T.3    Tuerk, J.4    Teutenberg, T.5    Rosenhagen, M.6    Hennies, D.7    Hoppe-Tichy, T.8    Wenclawiak, B.9
  • 103
    • 72049084517 scopus 로고    scopus 로고
    • Investigation of porous graphitic carbon at high-temperature liquid chromatography with evaporative light scattering detection for the analysis of the drug combination artesunate-Azithromycin for the treatment of severe malaria
    • Gaudin, K.; Millet, P.; Fawaz, F.; Olliaro, P.; White, N. J.; Cassus-Coussere, C.; Agbahoungha, U.; Dubost, J. P. Investigation of Porous Graphitic Carbon at High-Temperature Liquid Chromatography with Evaporative Light Scattering Detection for the Analysis of the Drug Combination Artesunate-Azithromycin for the Treatment of Severe Malaria. J. Chromatogr. A 2010, 1217, 75-81.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 75-81
    • Gaudin, K.1    Millet, P.2    Fawaz, F.3    Olliaro, P.4    White, N.J.5    Cassus-Coussere, C.6    Agbahoungha, U.7    Dubost, J.P.8
  • 104
    • 70350685786 scopus 로고    scopus 로고
    • Use of high-temperature liquid chromatography with sub-2 mm particle C18 columns for the analysis of seized drugs
    • Lurie, I.; Li, L. Use of High-Temperature Liquid Chromatography with Sub-2 mm Particle C18 Columns for the Analysis of Seized Drugs. J. Liq. Chromatogr. Relat. Technol. 2009, 32, 2615-2626.
    • (2009) J. Liq. Chromatogr. Relat. Technol. , vol.32 , pp. 2615-2626
    • Lurie, I.1    Li, L.2
  • 105
    • 67449164832 scopus 로고    scopus 로고
    • High-temperature liquid chromatography of steroids on a bonded hybrid column
    • Al-Khateeb, L. A.; Smith, R. M. High-Temperature Liquid Chromatography of Steroids on a Bonded Hybrid Column. Anal. Bioanal. Chem. 2009, 394, 1255-1260.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 1255-1260
    • Al-Khateeb, L.A.1    Smith, R.M.2
  • 106
    • 30344451983 scopus 로고    scopus 로고
    • Some advantages of high temperature for the separation of pharmaceutical compounds with mass spectrometry detection
    • Albert, M.; Cretier, G.; Guillarme, D.; Heinisch, S.; Rocca, J. L. Some Advantages of High Temperature for the Separation of Pharmaceutical Compounds with Mass Spectrometry Detection. J. Sep. Sci. 2005, 28, 1803-1811.
    • (2005) J. Sep. Sci. , vol.28 , pp. 1803-1811
    • Albert, M.1    Cretier, G.2    Guillarme, D.3    Heinisch, S.4    Rocca, J.L.5