메뉴 건너뛰기




Volumn 32, Issue 18, 2009, Pages 2615-2626

Use of high-temperature liquid chromatography with sub-2m particle C18 columns for the analysis of seized drugs

Author keywords

Anabolic steroids; High temperature liquid chromatography; Seized drugs; Sub 2m particle C18 column

Indexed keywords

ANABOLIC STEROID; ANABOLIC STEROIDS; CONSTANT GRADIENTS; DRUG COMPOUNDS; DRUG SCREENING; ELEVATED TEMPERATURE; HIGH-TEMPERATURE LIQUID CHROMATOGRAPHIES; HIGH-TEMPERATURE LIQUID CHROMATOGRAPHY; INCREASED TEMPERATURE; RELATIVE RETENTION TIME; RETENTION TIME; SEIZED DRUGS; SUB-2M PARTICLE C18 COLUMN;

EID: 70350685786     PISSN: 10826076     EISSN: 1520572X     Source Type: Journal    
DOI: 10.1080/10826070903245516     Document Type: Article
Times cited : (11)

References (19)
  • 2
    • 28844441999 scopus 로고    scopus 로고
    • High-performance liquid chromatography of seized drugs at elevated pressure with 1.7 mm hybrid C18 stationary phase columns
    • Lurie, I.S. High-performance liquid chromatography of seized drugs at elevated pressure with 1.7 mm hybrid C18 stationary phase columns. J. Chromatogr. A 2005, 1100, 168-175.
    • (2005) J. Chromatogr. A , vol.1100 , pp. 168-175
    • Lurie, I.S.1
  • 3
    • 34250203418 scopus 로고
    • High-performance liquid chromatography at elevated temperatures: Examination of conditions for the rapid separation of large molecules
    • Anita, F.; Horvath, Cs. High-performance liquid chromatography at elevated temperatures: examination of conditions for the rapid separation of large molecules. J. Chromatogr. A 1988, 435, 1-15.
    • (1988) J. Chromatogr. A , vol.435 , pp. 1-15
    • Anita, F.1    Horvath, Cs.2
  • 4
    • 33750259677 scopus 로고    scopus 로고
    • Generation of ultrahigh peak capacity LC separations via elevated temperatures and high linear mobile-phase velocities
    • Plumb, R.S.; Rainville, P.; Sith, B.W.; Johnson, K.A.; Castro-Perez, J.; Wilson, I.D.; Nicholson, J.K. Generation of ultrahigh peak capacity LC separations via elevated temperatures and high linear mobile-phase velocities. Anal. Chem. 2006, 78, 7278-7283.
    • (2006) Anal. Chem. , vol.78 , pp. 7278-7283
    • Plumb, R.S.1    Rainville, P.2    Sith, B.W.3    Johnson, K.A.4    Castro-Perez, J.5    Wilson, I.D.6    Nicholson, J.K.7
  • 5
    • 34250186446 scopus 로고    scopus 로고
    • The application of small porous particles, high temperatures, and high pressures to generate very high resolution LC and LC=MS separations
    • Plumb, R.; Mazzeo, J.R.; Grumbach, E.S.; Rainville, P.; Jones, M.; Wheat, T.; Neue, U.D.; Smith, B.; Johnson, K.A. The application of small porous particles, high temperatures, and high pressures to generate very high resolution LC and LC=MS separations. J. Sep. Sci. 2007, 30, 1158-1166.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1158-1166
    • Plumb, R.1    Mazzeo, J.R.2    Grumbach, E.S.3    Rainville, P.4    Jones, M.5    Wheat, T.6    Neue, U.D.7    Smith, B.8    Johnson, K.A.9
  • 7
    • 34547504080 scopus 로고    scopus 로고
    • Practice and theory of high temperature liquid chromatography
    • McNeff, C.V.; Yan, B.; Stoll, D.R.; Henry, R.A. Practice and theory of high temperature liquid chromatography. J. Sep. Sci. 2007, 30, 1672-1685.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1672-1685
    • McNeff, C.V.1    Yan, B.2    Stoll, D.R.3    Henry, R.A.4
  • 8
    • 33645640012 scopus 로고    scopus 로고
    • Fast and efficient separations using reversed phase liquid chromatography
    • Wu, N.; Thompson, R. Fast and efficient separations using reversed phase liquid chromatography. J. Liq. Chromatogr. & Rel. Technol. 2006, 29, 949-988.
    • (2006) J. Liq. Chromatogr. & Rel. Technol. , vol.29 , pp. 949-988
    • Wu, N.1    Thompson, R.2
  • 9
    • 0036500211 scopus 로고    scopus 로고
    • A study of the critical criteria for analyte stability in high-temperature liquid chromatography
    • Thompson, J.D.; Carr, P.W. A study of the critical criteria for analyte stability in high-temperature liquid chromatography. Anal. Chem. 2002, 74, 1017-1023.
    • (2002) Anal. Chem. , vol.74 , pp. 1017-1023
    • Thompson, J.D.1    Carr, P.W.2
  • 10
    • 0004115629 scopus 로고
    • The use of high performance liquid chromatography for the detection and quantiation of abused drugs
    • Gough, T., Ed.; Wiley: Chichester, UK
    • Caddy, B. The Use Of High Performance Liquid Chromatography for the Detection and Quantiation of Abused Drugs. in The Analysis of Drugs of Abuse; Gough, T., Ed.; Wiley: Chichester, UK, 1991; 121-174.
    • (1991) The Analysis of Drugs of Abuse , pp. 121-174
    • Caddy, B.1
  • 12
    • 0030596168 scopus 로고    scopus 로고
    • Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions
    • Zhu, P.L.; Snyder, L.R.; Dolan, J.W.; Djordjevic, N.M.; Hill, D.W.; Sander, L.C.; Waeghe, T.J. Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions. J. Chromatogr. A 1996, 756, 21-39.
    • (1996) J. Chromatogr. A , vol.756 , pp. 21-39
    • Zhu, P.L.1    Snyder, L.R.2    Dolan, J.W.3    Djordjevic, N.M.4    Hill, D.W.5    Sander, L.C.6    Waeghe, T.J.7
  • 13
    • 49949120541 scopus 로고
    • Enthalpy-entropy compensation in reversed-phase chromatography
    • Melander, W.; Campbell, D.E.; Horvath, Cs. Enthalpy-entropy compensation in reversed-phase chromatography J. Chromatogr. 1978, 158, 215-225.
    • (1978) J. Chromatogr. , vol.158 , pp. 215-225
    • Melander, W.1    Campbell, D.E.2    Horvath, Cs.3
  • 14
    • 4744367342 scopus 로고    scopus 로고
    • Effect of temperature in reverse phase liquid chromatography
    • Guillarme, D.; Heinisch, S.; Rocca, J.L. Effect of temperature in reverse phase liquid chromatography. J. Chromatogr. A 2004, 1052, 39-51.
    • (2004) J. Chromatogr. A , vol.1052 , pp. 39-51
    • Guillarme, D.1    Heinisch, S.2    Rocca, J.L.3
  • 16
    • 70350659130 scopus 로고    scopus 로고
    • Unpublished data
    • Unpublished data.
  • 17
    • 0028672637 scopus 로고
    • The determination of anabolic steroids by MECC gradient HPLC and capillary GC
    • Lurie, I.S.; Sperling, A.R.; Meyers, R.P. The Determination of anabolic steroids by MECC, Gradient HPLC, and Capillary GC. J. Forensic Sci. 1994, 39, 74-85.
    • (1994) J. Forensic Sci. , vol.39 , pp. 74-85
    • Lurie, I.S.1    Sperling, A.R.2    Meyers, R.P.3
  • 19
    • 35348864401 scopus 로고    scopus 로고
    • Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for analysis of ionisable compounds?
    • McCalley, D.V. Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for analysis of ionisable compounds? J. Chromatogr. A 2007, 1171, 46-55.
    • (2007) J Chromatogr. A , vol.1171 , pp. 46-55
    • McCalley, D.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.