메뉴 건너뛰기




Volumn 54, Issue 3, 2011, Pages 458-462

A study of some practical aspects of high temperature liquid chromatography in pharmaceutical applications

Author keywords

Elevated temperature; Fast chromatography; Levonorgestrel; Steroids; Zirconia based column

Indexed keywords

10BETA HYDROXYLEVONORGESTREL; 6BETA HYDROXYLEVONORGESTREL; DELTA8(14) LEVONORGESTREL; LEVODION; LEVONORGESTREL; LEVONORGESTREL ABC TRIENE; METHANOL; UNCLASSIFIED DRUG; ZIRCONIUM OXIDE;

EID: 78149495902     PISSN: 07317085     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jpba.2010.09.012     Document Type: Article
Times cited : (10)

References (28)
  • 1
    • 1542407412 scopus 로고
    • Preston, Evanston, IL, A. Zlatkis (Ed.)
    • Maggs R.J. Advances in Chromatgraphy 1969, 303-309. Preston, Evanston, IL. A. Zlatkis (Ed.).
    • (1969) Advances in Chromatgraphy , pp. 303-309
    • Maggs, R.J.1
  • 2
    • 34250203418 scopus 로고
    • High-performance liquid chromatography at elevated temperatures: examination of conditions for the rapid separation of large molecules
    • Antia F.D., Horvath Cs. High-performance liquid chromatography at elevated temperatures: examination of conditions for the rapid separation of large molecules. J. Chromatogr. 1988, 435:1-15.
    • (1988) J. Chromatogr. , vol.435 , pp. 1-15
    • Antia, F.D.1    Horvath, C.2
  • 3
    • 0038439527 scopus 로고    scopus 로고
    • High-temperature liquid chromatography
    • Greibrokk T., Andersen T. High-temperature liquid chromatography. J. Chromatogr. A 2003, 1000:743-755.
    • (2003) J. Chromatogr. A , vol.1000 , pp. 743-755
    • Greibrokk, T.1    Andersen, T.2
  • 4
    • 34547504080 scopus 로고    scopus 로고
    • Practice and theory of high temperature liquid chromatography
    • McNeff C.V., Yan B., Stoll D.R., Henry R.A. Practice and theory of high temperature liquid chromatography. J. Sep. Sci. 2007, 30:1672-1685.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1672-1685
    • McNeff, C.V.1    Yan, B.2    Stoll, D.R.3    Henry, R.A.4
  • 5
    • 77951953276 scopus 로고    scopus 로고
    • Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography
    • Vanhoenacker G., Pereira A.D.S., Kotsuka T., Cabooter D., Desmet G., Sandra P. Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography. J. Chromatogr. A 2009, 1217:3217-3222.
    • (2009) J. Chromatogr. A , vol.1217 , pp. 3217-3222
    • Vanhoenacker, G.1    Pereira, A.D.S.2    Kotsuka, T.3    Cabooter, D.4    Desmet, G.5    Sandra, P.6
  • 6
    • 0035853621 scopus 로고    scopus 로고
    • Superheated water as eluent in high-temperature high-performance liquid chromatograph
    • Fields S.M., Ye C.Q., Zhang D.D., Branch B.R., Zhang X.J., Okafe N. Superheated water as eluent in high-temperature high-performance liquid chromatograph. J. Chromatogr. A 2001, 913:197-204.
    • (2001) J. Chromatogr. A , vol.913 , pp. 197-204
    • Fields, S.M.1    Ye, C.Q.2    Zhang, D.D.3    Branch, B.R.4    Zhang, X.J.5    Okafe, N.6
  • 7
    • 33646007704 scopus 로고    scopus 로고
    • Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase
    • Teutenberg T., Goetze H.-J., Tuerk J., Ploeger J., Kiffmeyer T.K., Schmidt K.G., Kohorst W.gr., Rohe T., Jansen H.-D., Weber H. Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase. J. Chromatogr. A 2006, 1114:89-96.
    • (2006) J. Chromatogr. A , vol.1114 , pp. 89-96
    • Teutenberg, T.1    Goetze, H.-J.2    Tuerk, J.3    Ploeger, J.4    Kiffmeyer, T.K.5    Schmidt, K.G.6    Kohorst, W.7    Rohe, T.8    Jansen, H.-D.9    Weber, H.10
  • 8
    • 58149105278 scopus 로고    scopus 로고
    • Sense and nonsense of high-temperature liquid chromatography
    • Heinisch S., Rocca J.L. Sense and nonsense of high-temperature liquid chromatography. J. Chromatogr. A 2009, 1216:642-658.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 642-658
    • Heinisch, S.1    Rocca, J.L.2
  • 9
    • 0034929447 scopus 로고    scopus 로고
    • Silica and other materials as supports in liquid chromatography. Chromatographic tests and their importance for evaluating these supports. Part I-II
    • Stella C., Rudaz S., Veuthey J.-L., Tchapla A. Silica and other materials as supports in liquid chromatography. Chromatographic tests and their importance for evaluating these supports. Part I-II. Chromatographia 2001, 53:113-140.
    • (2001) Chromatographia , vol.53 , pp. 113-140
    • Stella, C.1    Rudaz, S.2    Veuthey, J.-L.3    Tchapla, A.4
  • 10
    • 11444249402 scopus 로고    scopus 로고
    • Stationary phases for high temperature liquid chromatography
    • Yang Y. Stationary phases for high temperature liquid chromatography. LC GC Europe 2003, 6:37-41.
    • (2003) LC GC Europe , vol.6 , pp. 37-41
    • Yang, Y.1
  • 11
    • 0347899380 scopus 로고    scopus 로고
    • Chromatography using ultra-stable metal oxide-based stationary phases for HPLC
    • Nawrocki J., Dunlap C., McCorrnich A., Carr P.W., Pert I. Chromatography using ultra-stable metal oxide-based stationary phases for HPLC. J. Chromatogr. A 2004, 1028:1-30.
    • (2004) J. Chromatogr. A , vol.1028 , pp. 1-30
    • Nawrocki, J.1    Dunlap, C.2    McCorrnich, A.3    Carr, P.W.4    Pert, I.5
  • 13
    • 0000413480 scopus 로고    scopus 로고
    • Analytical advantages of highly stable stationary phases for reversed-phase LC
    • Neff C.Mc., Zigan L., Johnson K., Carr P.W., Wang A., Weber-Main A.M. Analytical advantages of highly stable stationary phases for reversed-phase LC. LC GC 2000, 18:514-529.
    • (2000) LC GC , vol.18 , pp. 514-529
    • Neff, C.1    Zigan, L.2    Johnson, K.3    Carr, P.W.4    Wang, A.5    Weber-Main, A.M.6
  • 14
    • 34250205250 scopus 로고    scopus 로고
    • Temperature stability of reversed phase and normal phase stationary phases under aqueous conditions
    • Teutenberg T., Tuerk J., Holzhauser M., Giegold S. Temperature stability of reversed phase and normal phase stationary phases under aqueous conditions. J. Sep. Sci. 2007, 30:1101-1114.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1101-1114
    • Teutenberg, T.1    Tuerk, J.2    Holzhauser, M.3    Giegold, S.4
  • 15
    • 1242338068 scopus 로고    scopus 로고
    • Effect of high-temperature on high-performance liquid chromatography column stability and performance under temperature-programmed conditions
    • Marin S.J., Jones B.A., Felix W.D., Clark J. Effect of high-temperature on high-performance liquid chromatography column stability and performance under temperature-programmed conditions. J. Chromatogr. A 2004, 1030:255-262.
    • (2004) J. Chromatogr. A , vol.1030 , pp. 255-262
    • Marin, S.J.1    Jones, B.A.2    Felix, W.D.3    Clark, J.4
  • 16
    • 9644272404 scopus 로고    scopus 로고
    • Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography
    • Claessens H.A., van Straten M.A. Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography. J. Chromatogr. A 2004, 1060:23-41.
    • (2004) J. Chromatogr. A , vol.1060 , pp. 23-41
    • Claessens, H.A.1    van Straten, M.A.2
  • 17
    • 84984085862 scopus 로고
    • Correlation of diffusion coefficients in dilute solutions
    • Wilke C.R., Chang P. Correlation of diffusion coefficients in dilute solutions. Am. Inst. Chem. Eng. J. 1955, 1:264-270.
    • (1955) Am. Inst. Chem. Eng. J. , vol.1 , pp. 264-270
    • Wilke, C.R.1    Chang, P.2
  • 18
    • 33847309138 scopus 로고    scopus 로고
    • Elevated temperature-extended column length conventional liquid chromatography to increase peak capacity for the analysis, of tryptic digest
    • Sandra P., Vanhoenacker G. Elevated temperature-extended column length conventional liquid chromatography to increase peak capacity for the analysis, of tryptic digest. J. Sep. Sci. 2007, 30:241-244.
    • (2007) J. Sep. Sci. , vol.30 , pp. 241-244
    • Sandra, P.1    Vanhoenacker, G.2
  • 19
    • 39749116388 scopus 로고    scopus 로고
    • Superheated water chromatography-a green technology for the future
    • Smith R.M. Superheated water chromatography-a green technology for the future. J. Chromatogr. A 2008, 1184:441-455.
    • (2008) J. Chromatogr. A , vol.1184 , pp. 441-455
    • Smith, R.M.1
  • 20
    • 20544456576 scopus 로고    scopus 로고
    • High temperature liquid chromatography and liquid chromatography-mass spectroscopy analysis of octylphenol ethoxylates on different stationary phases
    • Vanhoenacker G., Sandra P. High temperature liquid chromatography and liquid chromatography-mass spectroscopy analysis of octylphenol ethoxylates on different stationary phases. J. Chromatogr. A 2005, 1082:193-202.
    • (2005) J. Chromatogr. A , vol.1082 , pp. 193-202
    • Vanhoenacker, G.1    Sandra, P.2
  • 21
    • 9144256210 scopus 로고    scopus 로고
    • High temperature liquid chromatography of triazole fungicides on polybutadiene-coated zirconia stationary phase
    • Sanagi M.M., See H.H., Ibrahim W.A.W., Naim A.A. High temperature liquid chromatography of triazole fungicides on polybutadiene-coated zirconia stationary phase. J. Chromatogr. A 2004, 1059:95-101.
    • (2004) J. Chromatogr. A , vol.1059 , pp. 95-101
    • Sanagi, M.M.1    See, H.H.2    Ibrahim, W.A.W.3    Naim, A.A.4
  • 22
    • 29644434784 scopus 로고    scopus 로고
    • High temperature high performance liquid chromatography of triazole fungicides on carbon-clad zirconia stationary phase
    • Sanagi M.M., Heng S.H., Ibrahim W.A.W., Naim A.A. High temperature high performance liquid chromatography of triazole fungicides on carbon-clad zirconia stationary phase. Malays. J. Chem. 2004, 6:55-66.
    • (2004) Malays. J. Chem. , vol.6 , pp. 55-66
    • Sanagi, M.M.1    Heng, S.H.2    Ibrahim, W.A.W.3    Naim, A.A.4
  • 23
    • 37549021951 scopus 로고    scopus 로고
    • Separation of free sterols by high temperature liquid chromatography
    • Riddle L.A., Guiochon G. Separation of free sterols by high temperature liquid chromatography. J. Chromatogr. A 2006, 1137:173-179.
    • (2006) J. Chromatogr. A , vol.1137 , pp. 173-179
    • Riddle, L.A.1    Guiochon, G.2
  • 24
    • 67449164832 scopus 로고    scopus 로고
    • High temperature liquid chromatography of steroids on a bonded hybrid column
    • Al-Khateeb L.A., Smith R.M. High temperature liquid chromatography of steroids on a bonded hybrid column. Anal. Bioanal. Chem. 2009, 394:1255-1260.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 1255-1260
    • Al-Khateeb, L.A.1    Smith, R.M.2
  • 25
    • 0031092087 scopus 로고    scopus 로고
    • Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia
    • Li J., Carr P.W. Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia. Anal. Chem. 1997, 69:837-843.
    • (1997) Anal. Chem. , vol.69 , pp. 837-843
    • Li, J.1    Carr, P.W.2
  • 27
    • 4744367342 scopus 로고    scopus 로고
    • Effect of temperature in reversed phase liquid chromatography
    • Guillarme D., Heinisch S., Rocca J.L. Effect of temperature in reversed phase liquid chromatography. J. Chromatogr. A 2004, 1052:39-51.
    • (2004) J. Chromatogr. A , vol.1052 , pp. 39-51
    • Guillarme, D.1    Heinisch, S.2    Rocca, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.