메뉴 건너뛰기




Volumn 38, Issue 15, 2006, Pages 20-26

Applications of High-Temperature Liquid Chromatography (HT-LC) in a pharmaceutical setting: Challenges and accomplishments

Author keywords

[No Author keywords available]

Indexed keywords

DRUG PRODUCTS; PERMITTIVITY; THROUGHPUT; VISCOSITY;

EID: 33751040802     PISSN: 00447749     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (8)
  • 1
    • 0038439527 scopus 로고    scopus 로고
    • High-temperature liquid chromatography
    • Greibrokk, T.; Andersen, T. High-temperature liquid chromatography. J. Chromatogr. A 2003, 1000(1), 743-55.
    • (2003) J. Chromatogr. A , vol.1000 , Issue.1 , pp. 743-755
    • Greibrokk, T.1    Andersen, T.2
  • 2
    • 11844251199 scopus 로고    scopus 로고
    • Elevated temperature HPLC: Principles and applications to small molecules and biomolecules
    • Zhu, C.; Goodall, D.M.; Wren, S.A.C. Elevated temperature HPLC: principles and applications to small molecules and biomolecules. LC·GC North Amer. 2005, 23(1), 54-72.
    • (2005) LC·GC North Amer. , vol.23 , Issue.1 , pp. 54-72
    • Zhu, C.1    Goodall, D.M.2    Wren, S.A.C.3
  • 3
    • 8844240708 scopus 로고    scopus 로고
    • Using high temperature HPLC for improved analysis
    • Clark, J. Using high temperature HPLC for improved analysis. Pharm. Tech. Eur. 2004, 16(5), 41-6.
    • (2004) Pharm. Tech. Eur. , vol.16 , Issue.5 , pp. 41-46
    • Clark, J.1
  • 4
    • 33751024690 scopus 로고    scopus 로고
    • Temperature-programmed HPLC
    • Clark, J. Temperature-programmed HPLC. Today's Chemist at Work 2004, 13(8), 43-5.
    • (2004) Today's Chemist at Work , vol.13 , Issue.8 , pp. 43-45
    • Clark, J.1
  • 5
    • 9144256210 scopus 로고    scopus 로고
    • High temperature liquid chromatography of triazole fungicides on polybutadiene-coated zirconia stationary phase
    • Sanagi, M.M.; See, H.H.; Ibrahim, W.A.W.; Naim, A.A. High temperature liquid chromatography of triazole fungicides on polybutadiene-coated zirconia stationary phase. J. Chromatogr. A 2004, 1059(1), 95-101.
    • (2004) J. Chromatogr. A , vol.1059 , Issue.1 , pp. 95-101
    • Sanagi, M.M.1    See, H.H.2    Ibrahim, W.A.W.3    Naim, A.A.4
  • 6
    • 0036500211 scopus 로고    scopus 로고
    • A study of the critical criteria for analyte stability in high-temperature liquid chromatography
    • Thompson, J.D.; Carr, P.W. A study of the critical criteria for analyte stability in high-temperature liquid chromatography. Anal. Chem. 2002, 74(5), 1017-23.
    • (2002) Anal. Chem. , vol.74 , Issue.5 , pp. 1017-1023
    • Thompson, J.D.1    Carr, P.W.2
  • 7
    • 20444481662 scopus 로고    scopus 로고
    • High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability
    • Yang, X.; Ma, L.; Carr, P.W. High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability. J. Chromatogr. A 2005, 1079(1), 213-20.
    • (2005) J. Chromatogr. A , vol.1079 , Issue.1 , pp. 213-220
    • Yang, X.1    Ma, L.2    Carr, P.W.3
  • 8
    • 1242338068 scopus 로고    scopus 로고
    • Effect of high-temperature on high-performance liquid chromatography column stability and performance under temperature-programmed conditions
    • Marin, S.J.; Jones, B.A.; Felix, W.D.; Clark, J. Effect of high-temperature on high-performance liquid chromatography column stability and performance under temperature-programmed conditions. J. Chromatogr. A 2004, 1030(1), 255-62.
    • (2004) J. Chromatogr. A , vol.1030 , Issue.1 , pp. 255-262
    • Marin, S.J.1    Jones, B.A.2    Felix, W.D.3    Clark, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.