Volumn 19, Issue 4, 2011, Pages 163-176

Optimization of radiation dose reduction in cardiac computed tomographic angiography

Author keywords

ALARA; cardiac computed tomographic angiography; medical radiation exposure; radiation dose reduction; radiation exposure

Indexed keywords

CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIAGNOSTIC IMAGING; HEART SCINTISCANNING; HUMAN; IMAGE QUALITY; PRACTICE GUIDELINE; PROCESS OPTIMIZATION; RADIATION DOSE; RADIATION EXPOSURE; REVIEW; RISK ASSESSMENT; STANDARDIZATION;

EID: 79959264397     PISSN: 10615377     EISSN: 15384683     Source Type: Journal    
DOI: 10.1097/CRD.0b013e31821daa8f     Document Type: Review
Times cited : (25)

References (103)
  • 1
    • 78650993744 scopus 로고    scopus 로고
    • ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography
    • Taylor AJ, Cerqueira M, Hodgson JM, et al. ACCF/SCCT/ACR/AHA/ASE/ASNC/ NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. J Cardiovasc Comput Tomogr. 2010;4:407.e1-e33.
    • (2010) J Cardiovasc Comput Tomogr , vol.4
    • Taylor, A.J.1    Cerqueira, M.2    Hodgson, J.M.3
  • 2
    • 77949419896 scopus 로고    scopus 로고
    • Radiologic and nuclear medicine studies in the United States and worldwide: Frequency, radiation dose, and comparison with other radiation sources - 1950-20071
    • Mettler FA, Bhargavan M, Faulkner K, et al. Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources - 1950-20071. Radiology. 2009;253:520-531.
    • (2009) Radiology , vol.253 , pp. 520-531
    • Mettler, F.A.1    Bhargavan, M.2    Faulkner, K.3
  • 3
    • 56149126478 scopus 로고    scopus 로고
    • Medical radiation exposure in the U.S. in 2006: Preliminary results
    • Mettler FA Jr, Thomadsen BR, Bhargavan M, et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys. 2008;95:502-507.
    • (2008) Health Phys , vol.95 , pp. 502-507
    • Mettler Jr., F.A.1    Thomadsen, B.R.2    Bhargavan, M.3
  • 5
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). Part 1: Description of system
    • Hounsfield GN. Computerized transverse axial scanning (tomography). Part 1: description of system. Br J Radiol. 1973;46:1016-1022.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 6
    • 0015900847 scopus 로고
    • Computerized transverse axial scanning (tomography). Part 2: Clinical application
    • Ambrose J. Computerized transverse axial scanning (tomography). Part 2: clinical application. Br J Radiol. 1973;46:1023-1047.
    • (1973) Br J Radiol , vol.46 , pp. 1023-1047
    • Ambrose, J.1
  • 7
    • 0015852496 scopus 로고
    • Computerized transverse axial scanning (tomography). Part 3: Radiation dose considerations
    • Perry BJ, Bridges C. Computerized transverse axial scanning (tomography). Part 3: radiation dose considerations. Br J Radiol. 1973;46:1048-1051.
    • (1973) Br J Radiol , vol.46 , pp. 1048-1051
    • Perry, B.J.1    Bridges, C.2
  • 8
    • 0019198182 scopus 로고
    • Computed medical imaging
    • Hounsfield GN. Computed medical imaging. Science. 1980;210:22-28. (Pubitemid 11192047)
    • (1980) Science , vol.210 , Issue.4465 , pp. 22-28
    • Hounsfield, G.N.1
  • 9
    • 0019488396 scopus 로고
    • Computed tomography of the heart: ECG-gated and continuous scans
    • Lackner K, Thurn P. Computed tomography of the heart: ECG-gated and continuous scans. Radiology. 1981;140:413-420. (Pubitemid 11039971)
    • (1981) Radiology , vol.140 , Issue.2 , pp. 413-420
    • Lackner, K.1    Thurn, P.2
  • 11
    • 0017062346 scopus 로고
    • Computed tomography of the normal and infarcted myocardium
    • Adams D, Hessel S, Judy P, et al. Computed tomography of the normal and infarcted myocardium. Am J Roentgenol. 1976;126:786-791.
    • (1976) Am J Roentgenol , vol.126 , pp. 786-791
    • Adams, D.1    Hessel, S.2    Judy, P.3
  • 12
    • 0018766290 scopus 로고
    • Evaluation of myocardial ischemic damage of various ages by computerized transmission tomography. Time-dependent effects of contrast material
    • Higgins C, Siemers P, Schmidt W, et al. Evaluation of myocardial ischemic damage of various ages by computerized transmission tomography. Time-dependent effects of contrast material. Circulation. 1979;60:284-291. (Pubitemid 9229216)
    • (1979) Circulation , vol.60 , Issue.2 , pp. 284-291
    • Higgins, C.B.1    Siemers, P.T.2    Schmidt, W.3    Newell, J.D.4
  • 13
    • 0019775580 scopus 로고
    • Detection of intraventricular thrombi by computed tomography
    • Godwin JD, Herfkens RJ, Skiöldebrand CG, et al. Detection of intraventricular thrombi by computed tomography. Radiology. 1981;138:717-721. (Pubitemid 12192253)
    • (1981) Radiology , vol.138 , Issue.5 , pp. 717-721
    • Godwin, J.D.1    Herfkens, R.J.2    Skioldebrand, C.G.3
  • 14
    • 0018908466 scopus 로고
    • Detection of patent coronary bypass grafts by computed tomography. A preliminary report
    • Brundage B, Lipton M, Herfkens R, et al. Detection of patent coronary bypass grafts by computed tomography. A preliminary report. Circulation. 1980;61:826-831.
    • (1980) Circulation , vol.61 , pp. 826-831
    • Brundage, B.1    Lipton, M.2    Herfkens, R.3
  • 15
    • 0018862904 scopus 로고
    • The use of computed tomography in the diagnosis of coronary artery bypass graft patency
    • DOI 10.1007/BF02551956
    • Guthaner D, Brody W, Ricci M, et al. The use of computed tomography in the diagnosis of coronary artery bypass graft patency. Cardiovasc Intervent Radiol. 1980;3:3-8. (Pubitemid 10157262)
    • (1980) CardioVascular and Interventional Radiology , vol.3 , Issue.1 , pp. 3-8
    • Guthaner, D.F.1    Brody, W.R.2    Ricci, M.3
  • 16
    • 0017740652 scopus 로고
    • Stop-action cardiac computed tomography
    • Harell GS, Guthaner DF, Breiman RS, et al. Stop-action cardiac computed tomography. Radiology. 1977;123:515-517.
    • (1977) Radiology , vol.123 , pp. 515-517
    • Harell, G.S.1    Guthaner, D.F.2    Breiman, R.S.3
  • 17
    • 0018891166 scopus 로고
    • Physics and technical considerations in the design of the DSR: A high temporal resolution volume scanner
    • Ritman E, Kinsey J, Robb R, et al. Physics and technical considerations in the design of the DSR: a high temporal resolution volume scanner. Am J Roentgenol. 1980;134:369-374. (Pubitemid 10182157)
    • (1980) American Journal of Roentgenology , vol.134 , Issue.2 , pp. 369-374
    • Ritman, E.L.1    Kinsey, J.H.2    Robb, R.A.3
  • 18
    • 0021145251 scopus 로고
    • Cardiac imaging with a high-speed Cine-CT scanner: Preliminary results
    • Lipton MJ, Higgins CB, Farmer D, et al. Cardiac imaging with a high-speed Cine-CT Scanner: preliminary results. Radiology. 1984;152:579-582. (Pubitemid 14060597)
    • (1984) Radiology , vol.152 , Issue.3 , pp. 579-582
    • Lipton, M.J.1    Higgins, C.B.2    Farmer, D.3    Boyd, D.P.4
  • 19
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford CR, King KF. Computed tomography scanning with simultaneous patient translation. Med Phys. 1990;17:967-982.
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 20
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, et al. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology. 1990;176:181-183. (Pubitemid 20208133)
    • (1990) Radiology , vol.176 , Issue.1 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 21
    • 0030066343 scopus 로고    scopus 로고
    • Dual-slice spiral versus single-slice spiral scanning: Comparison of the physical performance of two computed tomography scanners
    • DOI 10.1118/1.597705
    • Liang Y, Kruger RA. Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. Med Phys. 1996;23:205-220. (Pubitemid 26060371)
    • (1996) Medical Physics , vol.23 , Issue.2 , pp. 205-220
    • Liang, Y.1    Kruger, R.A.2
  • 22
    • 0034610434 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT
    • Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation. 2000;102:2823-2828.
    • (2000) Circulation , vol.102 , pp. 2823-2828
    • Achenbach, S.1    Ulzheimer, S.2    Baum, U.3
  • 23
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • DOI 10.1001/jama.298.3.317
    • Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA. 2007;298:317-323. (Pubitemid 47080486)
    • (2007) Journal of the American Medical Association , vol.298 , Issue.3 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 24
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • Fazel R, Krumholz HM, Wang Y, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009;361:849-857.
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 25
    • 77950136923 scopus 로고    scopus 로고
    • National Council on Radiation Protection and Measurements Report shows substantial medical exposure increase
    • Schauer DA, Linton OW. National Council on Radiation Protection and Measurements Report shows substantial medical exposure increase. Radiology. 2009;253:293-296.
    • (2009) Radiology , vol.253 , pp. 293-296
    • Schauer, D.A.1    Linton, O.W.2
  • 26
    • 77956050676 scopus 로고    scopus 로고
    • Weighing the risks and benefits of cardiac imaging with ionizing radiation
    • Gerber TC, Gibbons RJ. Weighing the risks and benefits of cardiac imaging with ionizing radiation. JACC Cardiovasc Imaging. 2010;3:528-535.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 528-535
    • Gerber, T.C.1    Gibbons, R.J.2
  • 27
    • 77956020093 scopus 로고    scopus 로고
    • Low-level ionizing radiation from noninvasive cardiac imaging: Can we extrapolate estimated risks from epidemiologic data to the clinical setting?
    • Laskey WK, Feinendegen LE, Neumann RD, et al. Low-level ionizing radiation from noninvasive cardiac imaging: can we extrapolate estimated risks from epidemiologic data to the clinical setting? JACC Cardiovasc Imaging. 2010;3:517-524.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 517-524
    • Laskey, W.K.1    Feinendegen, L.E.2    Neumann, R.D.3
  • 28
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • Hausleiter J, Meyer T, Hermann F, et al. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009;301:500-507.
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 29
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med. 2007;357:2277-2284. (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 30
    • 84928096460 scopus 로고    scopus 로고
    • Tracking radiation exposure from diagnostic imaging devices at the NIH
    • Neumann RD, Bluemke DA. Tracking radiation exposure from diagnostic imaging devices at the NIH. J Am Coll Radiol. 2010;7:87-89.
    • (2010) J Am Coll Radiol , vol.7 , pp. 87-89
    • Neumann, R.D.1    Bluemke, D.A.2
  • 31
    • 34948887091 scopus 로고    scopus 로고
    • Effective dose: How should it be applied to medical exposures?
    • DOI 10.1259/bjr/25922439
    • Martin CJ. Effective dose: how should it be applied to medical exposures? Br J Radiol. 2007;80:639-647. (Pubitemid 47517809)
    • (2007) British Journal of Radiology , vol.80 , Issue.956 , pp. 639-647
    • Martin, C.J.1
  • 32
    • 45149085205 scopus 로고    scopus 로고
    • The application of effective dose to medical exposures
    • DOI 10.1093/rpd/ncm425
    • Martin CJ. The application of effective dose to medical exposures. Radiat Prot Dosimetry. 2008;128:1-4. (Pubitemid 351827514)
    • (2008) Radiation Protection Dosimetry , vol.128 , Issue.1 , pp. 1-4
    • Martin, C.J.1
  • 33
    • 77950600954 scopus 로고    scopus 로고
    • How effective is effective dose as a predictor of radiation risk?
    • McCollough CH, Christner JA, Kofler JM. How effective is effective dose as a predictor of radiation risk? Am J Roentgenol. 2010;194:890-896.
    • (2010) Am J Roentgenol , vol.194 , pp. 890-896
    • McCollough, C.H.1    Christner, J.A.2    Kofler, J.M.3
  • 34
    • 64949191402 scopus 로고    scopus 로고
    • The linear no-threshold relationship is inconsistent with radiation biologic and experimental data
    • Tubiana M, Feinendegen LE, Yang C, et al. The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology. 2009;251:13-22.
    • (2009) Radiology , vol.251 , pp. 13-22
    • Tubiana, M.1    Feinendegen, L.E.2    Yang, C.3
  • 35
    • 85032843101 scopus 로고    scopus 로고
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, Board on Radiation Effects Research, Division on Earth and Life Studies, National Research Counsil of the National Academies Washington, DC: National Academies Press
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, Board on Radiation Effects Research, Division on Earth and Life Studies, National Research Counsil of the National Academies. Health Risks From Exposure to Low Levels of Ionizing Radiation: BIER VII-Phase 2. Washington, DC: National Academies Press; 2006.
    • (2006) Health Risks from Exposure to Low Levels of Ionizing Radiation: BIER VII-Phase 2
  • 36
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 Recommendations of the International Commission on Radiological Protection
    • IRCP. ICRP Publication 103
    • IRCP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP. 2007:37:1-332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 37
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • DOI 10.1007/s00330-001-1278-x
    • Jakobs T, Becker C, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol. 2002;12:1081-1086. (Pubitemid 36940173)
    • (2002) European Radiology , vol.12 , Issue.5 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3    Flohr, T.4    Suess, C.5    Schoepf, U.J.6    Reiser, M.F.7
  • 38
    • 64049099090 scopus 로고    scopus 로고
    • Radiation dose in a "triple rule-out" coronary CT angiography protocol of emergency department patients using 64-MDCT: The impact of ECG-based tube current modulation on age, sex, and body mass index
    • Takakuwa KM, Halpern EJ, Gingold EL, et al. Radiation dose in a "triple rule-out" coronary CT angiography protocol of emergency department patients using 64-MDCT: the impact of ECG-based tube current modulation on age, sex, and body mass index. Am J Roentgenol. 2009;192:866-872.
    • (2009) Am J Roentgenol , vol.192 , pp. 866-872
    • Takakuwa, K.M.1    Halpern, E.J.2    Gingold, E.L.3
  • 40
    • 33745546975 scopus 로고    scopus 로고
    • MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose
    • DOI 10.2214/AJR.05.0216
    • Abada HT, Larchez C, Daoud B, et al. MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. Am J Roentgenol. 2006;186:S387-S390. (Pubitemid 46105409)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.6 SUPPL. A
    • Abada, H.T.1    Larchez, C.2    Daoud, B.3    Sigal-Cinqualbre, A.4    Paul, J.-F.5
  • 41
    • 77955539456 scopus 로고    scopus 로고
    • Cardiac computed tomography technology and dose-reduction strategies
    • Earls JP, Leipsic J. Cardiac computed tomography technology and dose-reduction strategies. Radiol Clin North Am. 2010;48:657-674.
    • (2010) Radiol Clin North Am , vol.48 , pp. 657-674
    • Earls, J.P.1    Leipsic, J.2
  • 42
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • DOI 10.1161/CIRCULATIONAHA.105.602490, PII 0000301720060314000008
    • Hausleiter J, Meyer T, Hadamitzky M, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006;113:1305-1310. (Pubitemid 43739452)
    • (2006) Circulation , vol.113 , Issue.10 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5    Martinoff, S.6    Kastrati, A.7    Schomig, A.8
  • 43
    • 67849090531 scopus 로고    scopus 로고
    • Options for reducing patient radiation dose with cardiovascular computed tomography
    • Halliburton SS. Options for reducing patient radiation dose with cardiovascular computed tomography. Int J Cardiovasc Imaging. 2009;25:153-164.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 153-164
    • Halliburton, S.S.1
  • 44
    • 0017665285 scopus 로고
    • A quantitative theory of the Hounsfield unit and its application to dual energy scanning
    • Brooks RA. A quantitative theory of the Hounsfield unit and its application to dual energy scanning. J Comput Assist Tomogr. 1977;1:487-493. (Pubitemid 8228115)
    • (1977) Journal of Computer Assisted Tomography , vol.1 , Issue.4 , pp. 487-493
    • Brooks, R.A.1
  • 45
    • 49049083272 scopus 로고    scopus 로고
    • Low kilovoltage cardiac dualsource CT: Attenuation, noise, and radiation dose
    • Leschka S, Stolzmann P, Schmid F, et al. Low kilovoltage cardiac dualsource CT: attenuation, noise, and radiation dose. Eur Radiol. 2008;18:1809-1817.
    • (2008) Eur Radiol , vol.18 , pp. 1809-1817
    • Leschka, S.1    Stolzmann, P.2    Schmid, F.3
  • 46
    • 77953872454 scopus 로고    scopus 로고
    • Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study
    • Feuchtner GM, Jodocy D, Klauser A, et al. Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol. 2010;75:e51-e56.
    • (2010) Eur J Radiol , vol.75
    • Feuchtner, G.M.1    Jodocy, D.2    Klauser, A.3
  • 47
    • 68549088465 scopus 로고    scopus 로고
    • Impact of a reduced tube voltage on CT angiography and radiation dose results of the PROTECTION I study
    • Bischoff B, Hein F, Meyer T, et al. Impact of a reduced tube voltage on CT angiography and radiation dose results of the PROTECTION I study. JACC Cardiovasc Imaging. 2009;2:940-946.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 940-946
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 48
    • 72449180069 scopus 로고    scopus 로고
    • Trends in radiation protection in CT: Present and future status
    • Bischoff B, Hein F, Meyer T, et al. Trends in radiation protection in CT: present and future status. J Cardiovasc Comput Tomogr. 2009;3:S65-S73.
    • (2009) J Cardiovasc Comput Tomogr , vol.3
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 49
    • 78249261294 scopus 로고    scopus 로고
    • Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II trial
    • Hausleiter J, Martinoff S, Hadamitzky M, et al. Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II trial. JACC Cardiovasc Imaging. 2010;3:1113-1123.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 1113-1123
    • Hausleiter, J.1    Martinoff, S.2    Hadamitzky, M.3
  • 51
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose 1
    • Earls JP, Berman EL, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose 1. Radiology. 2008;246:742-753.
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 52
    • 49049120370 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose
    • Hirai N, Horiguchi J, Fujioka C, et al. Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology. 2008;248:424-430.
    • (2008) Radiology , vol.248 , pp. 424-430
    • Hirai, N.1    Horiguchi, J.2    Fujioka, C.3
  • 53
    • 53949098971 scopus 로고    scopus 로고
    • Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: Comparison with retrospective electrocardiogram-gated helical scan
    • Maruyama T, Takada M, Hasuike T, et al. Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol. 2008;52:1450-1455.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1450-1455
    • Maruyama, T.1    Takada, M.2    Hasuike, T.3
  • 54
    • 68449090034 scopus 로고    scopus 로고
    • Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques
    • Arnoldi E, Johnson T, Rist C, et al. Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol. 2009;19:2147-2155.
    • (2009) Eur Radiol , vol.19 , pp. 2147-2155
    • Arnoldi, E.1    Johnson, T.2    Rist, C.3
  • 55
    • 64149120137 scopus 로고    scopus 로고
    • Radiation dose and image quality of prospective triggering with dual-source cardiac computed tomography
    • Blankstein R, Shah A, Pale R, et al. Radiation dose and image quality of prospective triggering with dual-source cardiac computed tomography. Am J Cardiol. 2009;103:1168-1173.
    • (2009) Am J Cardiol , vol.103 , pp. 1168-1173
    • Blankstein, R.1    Shah, A.2    Pale, R.3
  • 56
    • 71749092079 scopus 로고    scopus 로고
    • Comparison of image quality and radiation dose of coronary computed tomographic angiography between conventional helical scanning and a strategy incorporating sequential scanning
    • Einstein AJ, Wolff SD, Manheimer ED, et al. Comparison of image quality and radiation dose of coronary computed tomographic angiography between conventional helical scanning and a strategy incorporating sequential scanning. Am J Cardiol. 2009;104:1343-1350.
    • (2009) Am J Cardiol , vol.104 , pp. 1343-1350
    • Einstein, A.J.1    Wolff, S.D.2    Manheimer, E.D.3
  • 57
    • 67649400902 scopus 로고    scopus 로고
    • First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose
    • Hoe J, Toh KH. First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose. J Cardiovasc Comput Tomogr. 2009;3:257-261.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 257-261
    • Hoe, J.1    Toh, K.H.2
  • 58
    • 77953257520 scopus 로고    scopus 로고
    • Comparison of sequential and helical scanning for radiation dose and image quality: Results of the prospective multicenter study on radiation dose estimates of cardiac CT angiography (PROTECTION) I study
    • Bischoff B, Hein F, Meyer T, et al. Comparison of sequential and helical scanning for radiation dose and image quality: results of the prospective multicenter study on radiation dose estimates of cardiac CT angiography (PROTECTION) I study. Am J Roentgenol. 2010;194:1495-1499.
    • (2010) Am J Roentgenol , vol.194 , pp. 1495-1499
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 59
    • 77951104451 scopus 로고    scopus 로고
    • Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: Comparison of image quality and radiation dose
    • Jin K, Park E-A, Shin C-I, et al. Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Cardiovasc Imaging. 2010;26:63-73.
    • (2010) Int J Cardiovasc Imaging , vol.26 , pp. 63-73
    • Jin, K.1    Park, E.-A.2    Shin, C.-I.3
  • 60
    • 77957932120 scopus 로고    scopus 로고
    • Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: A phantom study
    • Lehmkuhl L, Gosch D, Nagel HD, et al. Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study. Eur Radiol. 2010;20:2116-2125.
    • (2010) Eur Radiol , vol.20 , pp. 2116-2125
    • Lehmkuhl, L.1    Gosch, D.2    Nagel, H.D.3
  • 61
    • 77950618805 scopus 로고    scopus 로고
    • Effect of padding duration on radiation dose and image interpretation in prospectively ECG-triggered coronary CT angiography
    • LaBounty TM, Leipsic J, Min JK, et al. Effect of padding duration on radiation dose and image interpretation in prospectively ECG-triggered coronary CT angiography. Am J Roentgenol. 2010;194:933-937.
    • (2010) Am J Roentgenol , vol.194 , pp. 933-937
    • LaBounty, T.M.1    Leipsic, J.2    Min, J.K.3
  • 62
    • 67849105498 scopus 로고    scopus 로고
    • Prospectively gated low-dose CCTA: 24 months experience in more than 2,000 clinical cases
    • Earls JP, Schrack EC. Prospectively gated low-dose CCTA: 24 months experience in more than 2,000 clinical cases. Int J Cardiovasc Imaging. 2008;25:177-187.
    • (2008) Int J Cardiovasc Imaging , vol.25 , pp. 177-187
    • Earls, J.P.1    Schrack, E.C.2
  • 63
    • 50249178242 scopus 로고    scopus 로고
    • Low-dose CT coronary angiography in the step-and-shoot mode: Diagnostic performance
    • Scheffel H, Alkadhi H, Leschka S, et al. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart. 2008;94:1132-1137.
    • (2008) Heart , vol.94 , pp. 1132-1137
    • Scheffel, H.1    Alkadhi, H.2    Leschka, S.3
  • 64
    • 57149117486 scopus 로고    scopus 로고
    • Influence of calcifications on diagnostic accuracy of coronary CT angiography using prospective ECG triggering
    • Stolzmann P, Scheffel H, Leschka S, et al. Influence of calcifications on diagnostic accuracy of coronary CT angiography using prospective ECG triggering. Am J Roentgenol. 2008;191:1684-1689.
    • (2008) Am J Roentgenol , vol.191 , pp. 1684-1689
    • Stolzmann, P.1    Scheffel, H.2    Leschka, S.3
  • 65
    • 70349774691 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: Comparison of results with cardiac catheterization in a head-to-head pilot investigation
    • Dewey M, Zimmermann E, Deissenrieder F, et al. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation. 2009;120:867-875.
    • (2009) Circulation , vol.120 , pp. 867-875
    • Dewey, M.1    Zimmermann, E.2    Deissenrieder, F.3
  • 66
    • 63449097524 scopus 로고    scopus 로고
    • High-pitch spiral acquisition: A new scan mode for coronary CT angiography
    • Achenbach S, Marwan M, Schepis T, et al. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr. 2009;3:117-121.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 117-121
    • Achenbach, S.1    Marwan, M.2    Schepis, T.3
  • 67
    • 67649399882 scopus 로고    scopus 로고
    • Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols
    • Hausleiter J, Bischoff B, Hein F, et al. Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols. J Cardiovasc Comput Tomogr. 2009;3:236-242.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 236-242
    • Hausleiter, J.1    Bischoff, B.2    Hein, F.3
  • 68
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECG-triggered highpitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
    • Lell M, Marwan M, Schepis T, et al. Prospectively ECG-triggered highpitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol. 2009;19:2576-2583.
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 69
    • 78649755609 scopus 로고    scopus 로고
    • Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT
    • Sommer WH, Albrecht E, Bamberg F, et al. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. Am J Roentgenol. 2010;195:1306-1312.
    • (2010) Am J Roentgenol , vol.195 , pp. 1306-1312
    • Sommer, W.H.1    Albrecht, E.2    Bamberg, F.3
  • 70
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • Achenbach S, Marwan M, Ropers D, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Euro Heart J. 2010;31:340-346.
    • (2010) Euro Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 71
    • 73949094933 scopus 로고    scopus 로고
    • High-pitch electrocardiogram-triggered computed tomography of the chest: Initial results
    • Lell M, Hinkmann F, Anders K, et al. High-pitch electrocardiogram- triggered computed tomography of the chest: initial results. Invest Radiol. 2009;44:728-733.
    • (2009) Invest Radiol , vol.44 , pp. 728-733
    • Lell, M.1    Hinkmann, F.2    Anders, K.3
  • 72
    • 56349130541 scopus 로고    scopus 로고
    • Technical principles of dual source CT
    • Petersilka M, Bruder H, Krauss B, et al. Technical principles of dual source CT. Eur J Radiol. 2008;68:362-368.
    • (2008) Eur J Radiol , vol.68 , pp. 362-368
    • Petersilka, M.1    Bruder, H.2    Krauss, B.3
  • 73
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • Thibault J-B, Sauer KD, Bouman CA, et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007;34:4526-4544. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 74
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • Leipsic J, LaBounty TM, Heilbron B, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. Am J Roentgenol. 2010;195:655-660.
    • (2010) Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    LaBounty, T.M.2    Heilbron, B.3
  • 76
    • 67949094410 scopus 로고    scopus 로고
    • New radiation dose saving technologies for 256-slice cardiac computed tomography angiography
    • Walker MJ, Olszewski ME, Desai MY, et al. New radiation dose saving technologies for 256-slice cardiac computed tomography angiography. Int J Cardiovasc Imaging. 2009;25:189-199.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 189-199
    • Walker, M.J.1    Olszewski, M.E.2    Desai, M.Y.3
  • 77
    • 60649112128 scopus 로고    scopus 로고
    • A new method to reduce radiation exposure during multi-row detector cardiac computed tomographic angiography
    • Gopal A, Budoff MJ. A new method to reduce radiation exposure during multi-row detector cardiac computed tomographic angiography. Int J Cardiol. 2009;132:435-436.
    • (2009) Int J Cardiol , vol.132 , pp. 435-436
    • Gopal, A.1    Budoff, M.J.2
  • 78
    • 74749092491 scopus 로고    scopus 로고
    • Dose reduction in helical CT: Dynamically adjustable z-axis x-ray beam collimation
    • Christner JA, Zavaletta VA, Eusemann CD, et al. Dose reduction in helical CT: dynamically adjustable z-axis x-ray beam collimation. Am J Roentgenol. 2009;194:W49-W55.
    • (2009) Am J Roentgenol , vol.194
    • Christner, J.A.1    Zavaletta, V.A.2    Eusemann, C.D.3
  • 79
    • 21144440833 scopus 로고    scopus 로고
    • The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
    • DOI 10.1118/1.1924309
    • Tzedakis A, Damilakis J, Perisinakis K, et al. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations. Med Phys. 2005;32:1621-1629. (Pubitemid 40880556)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1621-1629
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Stratakis, J.4    Gourtsoyiannis, N.5
  • 80
    • 33845655515 scopus 로고    scopus 로고
    • Overranging in multisection CT: Quantification and relative contribution to dose - Comparison of four 16-section CT scanners
    • DOI 10.1148/radiol.2421051350
    • van der Molen AJ, Geleijns J. Overranging in multisection ct: quantification and relative contribution to dose - comparison of four 16-section CT scanners. Radiology. 2007;242:208-216. (Pubitemid 44956026)
    • (2007) Radiology , vol.242 , Issue.1 , pp. 208-216
    • Van Der, M.A.J.1    Geleijns, J.2
  • 81
    • 36249014925 scopus 로고    scopus 로고
    • Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: Initial experience
    • DOI 10.1148/radiol.2453070094
    • Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology. 2007;245:703-711. (Pubitemid 350127340)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 703-711
    • Oncel, D.1    Oncel, G.2    Tastan, A.3
  • 82
    • 67849114628 scopus 로고    scopus 로고
    • Maximizing dose reductions with cardiac CT
    • Budoff MJ. Maximizing dose reductions with cardiac CT. Int J Cardiovasc Imaging. 2008;25:279-287.
    • (2008) Int J Cardiovasc Imaging , vol.25 , pp. 279-287
    • Budoff, M.J.1
  • 83
    • 63049124916 scopus 로고    scopus 로고
    • Ethical issues related to lung nodules on cardiac CT
    • Budoff MJ. Ethical issues related to lung nodules on cardiac CT. Am J Roentgenol. 2009;192:W146.
    • (2009) Am J Roentgenol , vol.192
    • Budoff, M.J.1
  • 84
    • 78650202675 scopus 로고    scopus 로고
    • The use of breast shielding for dose reduction in pediatric CT: Arguments against the proposition
    • Geleijns J, Wang J, McCollough C. The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition. Pediatr Radiol. 2010;40:1744-1747.
    • (2010) Pediatr Radiol , vol.40 , pp. 1744-1747
    • Geleijns, J.1    Wang, J.2    McCollough, C.3
  • 85
    • 33846634112 scopus 로고    scopus 로고
    • Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose
    • DOI 10.1097/01.rct.0000235070.50055.e6, PII 0000472820070100000022
    • Yilmaz MH, Albayram S, Yasar D, et al. Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose. J Comput Assisted Tomogr. 2007;31:138-142. (Pubitemid 46183352)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.1 , pp. 138-142
    • Yilmaz, M.H.1    Albayram, S.2    Yasar, D.3    Ozer, H.4    Adaletli, I.5    Selcuk, D.6    Akman, C.7    Altug, A.8
  • 87
    • 66749091803 scopus 로고    scopus 로고
    • In-plane shielding for CT: Effect of off-centering, automatic exposure control and shield-to-surface distance
    • Kalra MK, Dang P, Singh S, et al. In-plane shielding for CT: effect of off-centering, automatic exposure control and shield-to-surface distance. Korean J Radiol. 2009;10:156-163.
    • (2009) Korean J Radiol , vol.10 , pp. 156-163
    • Kalra, M.K.1    Dang, P.2    Singh, S.3
  • 88
    • 33748454831 scopus 로고    scopus 로고
    • Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    • DOI 10.1007/s00330-006-0217-2
    • Geleijns J, Salvadó Artells M, Veldkamp WJ, et al. Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol. 2006;16:2334-2340. (Pubitemid 44349882)
    • (2006) European Radiology , vol.16 , Issue.10 , pp. 2334-2340
    • Geleijns, J.1    Salvado, A.M.2    Veldkamp, W.J.H.3    Lopez, T.M.4    Calzado, C.A.5
  • 89
    • 48949116166 scopus 로고    scopus 로고
    • Reduction of dose to the female breast in thoracic CT: A comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations
    • Vollmar S, Kalender W. Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations. Eur Radiol. 2008;18:1674-1682.
    • (2008) Eur Radiol , vol.18 , pp. 1674-1682
    • Vollmar, S.1    Kalender, W.2
  • 90
    • 79959197404 scopus 로고    scopus 로고
    • Reducing mAs is as effective as a bismuth breast shield to minimize breast dose for chest CT when keeping mediastinal noise constant
    • Abstract (SSA04-05)
    • Berland LL, Yester MV, Fitzpatrick AF. Reducing mAs is as effective as a bismuth breast shield to minimize breast dose for chest CT when keeping mediastinal noise constant. In: Proceedings of RSNA; 2009. Abstract (SSA04-05).
    • Proceedings of RSNA; 2009
    • Berland, L.L.1    Yester, M.V.2    Fitzpatrick, A.F.3
  • 91
    • 38449112969 scopus 로고    scopus 로고
    • Pediatric chest mdct using tube current modulation: Effect on radiation dose with breast shielding
    • Coursey C, Frush DP, Yoshizumi T, et al. Pediatric chest mdct using tube current modulation: effect on radiation dose with breast shielding. Am J Roentgenol. 2008;190:W54-W61.
    • (2008) Am J Roentgenol , vol.190
    • Coursey, C.1    Frush, D.P.2    Yoshizumi, T.3
  • 92
    • 23844510187 scopus 로고    scopus 로고
    • Coronary artery calcium measurement with multi-detector row CT and low radiation dose: Comparison between 55 and 165 mAs
    • DOI 10.1148/radiol.2363040039
    • Shemesh J, Evron R, Koren-Morag N, et al. Coronary artery calcium measurement with multi-detector row CT and low radiation dose: comparison between 55 and 165 mAs1. Radiology. 2005;236:810-814. (Pubitemid 41170841)
    • (2005) Radiology , vol.236 , Issue.3 , pp. 810-814
    • Shemesh, J.1    Evron, R.2    Koren-Morag, N.3    Apter, S.4    Rozenman, J.5    Shaham, D.6    Itzchak, Y.7    Motro, M.8
  • 93
    • 0037700135 scopus 로고    scopus 로고
    • Quantification of coronary artery calcium with multi-detector row CT: Assessing interscan variability with different tube currents - Pilot study
    • DOI 10.1148/radiol.2281012035
    • Takahashi N, Bae KT. Quantification of coronary artery calcium with multi-detector row CT: assessing interscan variability with different tube currents - pilot study 1. Radiology. 2003;228:101-106. (Pubitemid 36736075)
    • (2003) Radiology , vol.228 , Issue.1 , pp. 101-106
    • Takahashi, N.1    Bae, K.T.2
  • 94
    • 33747038401 scopus 로고    scopus 로고
    • Coronary artery calcium scoring with multislice computed tomography: In vitro assessment of a low tube voltage protocol
    • DOI 10.1097/01.rli.0000233324.09603.dd, PII 0000442420060900000003
    • Thomas CK, Muhlenbruch G, Wildberger JE, et al. Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol. 2006;41:668-673. (Pubitemid 44213744)
    • (2006) Investigative Radiology , vol.41 , Issue.9 , pp. 668-673
    • Thomas, C.K.1    Muhlenbruch, G.2    Wildberger, J.E.3    Hohl, C.4    Das, M.5    Gunther, R.W.6    Mahnken, A.H.7
  • 95
    • 71949090707 scopus 로고    scopus 로고
    • Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography
    • Nakazato R, Dey D, Gutstein A, et al. Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography. J Cardiovasc Comput Tomogr. 2009;3:394-400.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 394-400
    • Nakazato, R.1    Dey, D.2    Gutstein, A.3
  • 96
    • 10644277990 scopus 로고    scopus 로고
    • Calcified coronary artery plaque measurement with cardiac CT in population-based studies: Standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study
    • DOI 10.1148/radiol.2341040439
    • Carr JJ, Nelson JC, Wong ND, et al. Calcified coronary artery plaque measurement with cardiac CT in population-based studies: standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study. Radiology. 2005;234:35-43. (Pubitemid 39658367)
    • (2005) Radiology , vol.234 , Issue.1 , pp. 35-43
    • Carr, J.J.1    Nelson, J.C.2    Wong, N.D.3    McNitt-Gray, M.4    Arad, Y.5    Jacobs Jr., D.R.6    Sidney, S.7    Bild, D.E.8    Williams, O.D.9    Detrano, R.C.10
  • 97
    • 77956036043 scopus 로고    scopus 로고
    • Cardiovascular imaging with computed tomography: Responsible steps to balancing diagnostic yield and radiation exposure
    • Halliburton SS, Schoenhagen P. Cardiovascular imaging with computed tomography: responsible steps to balancing diagnostic yield and radiation exposure. JACC Cardiovasc Imaging. 2010;3:536-540.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 536-540
    • Halliburton, S.S.1    Schoenhagen, P.2
  • 98
    • 70249150384 scopus 로고    scopus 로고
    • Triple-rule-out ct angiography for evaluation of acute chest pain and possible acute coronary syndrome
    • Halpern EJ. Triple-rule-out ct angiography for evaluation of acute chest pain and possible acute coronary syndrome. Radiology. 2009;252:332-345.
    • (2009) Radiology , vol.252 , pp. 332-345
    • Halpern, E.J.1
  • 99
    • 79951581829 scopus 로고    scopus 로고
    • Usefulness of Comprehensive Cardiothoracic Computed Tomography in the Evaluation of Acute Undifferentiated Chest Discomfort in the Emergency Department (CAPTURE)
    • Rogers IS, Banerji D, Siegel EL, et al. Usefulness of Comprehensive Cardiothoracic Computed Tomography in the Evaluation of Acute Undifferentiated Chest Discomfort in the Emergency Department (CAPTURE). Am J Cardiol. 2011;107:643-650.
    • (2011) Am J Cardiol , vol.107 , pp. 643-650
    • Rogers, I.S.1    Banerji, D.2    Siegel, E.L.3
  • 100
    • 79959380405 scopus 로고    scopus 로고
    • Low-dose triple-rule-out using 320-row-detector volume MDCT - Less contrast medium and lower radiation exposure
    • In press
    • Durmus T, Rogalla P, Lembcke A, et al. Low-dose triple-rule-out using 320-row-detector volume MDCT - less contrast medium and lower radiation exposure. Eur Radiol. In press.
    • Eur Radiol
    • Durmus, T.1    Rogalla, P.2    Lembcke, A.3
  • 101
    • 79952771284 scopus 로고    scopus 로고
    • Comparison of radiation dose and image quality of triple-rule-out computed tomography angiography between conventional helical scanning and a strategy incorporating sequential scanning
    • Manheimer ED, Peters MR, Wolff SD, et al. Comparison of radiation dose and image quality of triple-rule-out computed tomography angiography between conventional helical scanning and a strategy incorporating sequential scanning. Am J Cardiol. 2011;107:1093-1098.
    • (2011) Am J Cardiol , vol.107 , pp. 1093-1098
    • Manheimer, E.D.1    Peters, M.R.2    Wolff, S.D.3
  • 102
    • 78649323300 scopus 로고    scopus 로고
    • Effect of a standardized qualityimprovement protocol on radiation dose in coronary computed tomographic angiography
    • LaBounty TM, Earls JP, Leipsic J, et al. Effect of a standardized qualityimprovement protocol on radiation dose in coronary computed tomographic angiography. Am J Cardiol. 2010;106:1663-1667.
    • (2010) Am J Cardiol , vol.106 , pp. 1663-1667
    • LaBounty, T.M.1    Earls, J.P.2    Leipsic, J.3
  • 103
    • 77955680061 scopus 로고    scopus 로고
    • Effect of a standardized radiation dose reduction protocol on diagnostic accuracy of coronary computed tomographic angiography
    • LaBounty TM, Leipsic J, Mancini GB, et al. Effect of a standardized radiation dose reduction protocol on diagnostic accuracy of coronary computed tomographic angiography. Am J Cardiol. 2010;106:287-292.
    • (2010) Am J Cardiol , vol.106 , pp. 287-292
    • LaBounty, T.M.1    Leipsic, J.2    Mancini, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.