메뉴 건너뛰기




Volumn 3, Issue 5, 2010, Pages 536-540

Cardiovascular imaging with computed tomography: Responsible steps to balancing diagnostic yield and radiation exposure

Author keywords

cardiac; computed tomography; coronary; radiation dose

Indexed keywords

CARDIOVASCULAR SYSTEM; CLINICAL PROTOCOL; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC VALUE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RADIATION SAFETY; REVIEW; RISK ASSESSMENT; ARTICLE; CARDIOVASCULAR DISEASE; PATIENT SELECTION; PRACTICE GUIDELINE; PREDICTION AND FORECASTING; RADIATION INDUCED NEOPLASM; RADIATION RESPONSE; RADIOGRAPHY; RISK FACTOR;

EID: 77956036043     PISSN: 1936878X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcmg.2010.03.004     Document Type: Review
Times cited : (22)

References (33)
  • 1
    • 0019198182 scopus 로고
    • Computed medical imaging
    • G.N. Hounsfield Computed medical imaging Science 210 1980 22 28
    • (1980) Science , vol.210 , pp. 22-28
    • Hounsfield, G.N.1
  • 2
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomographyan increasing source of radiation exposure
    • D.J. Brenner, and E.J. Hall Computed tomographyan increasing source of radiation exposure N Engl J Med 357 2007 2277 2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • R. Fazel, H.M. Krumholz, and Y. Wang Exposure to low-dose ionizing radiation from medical imaging procedures N Engl J Med 361 2009 849 857
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 4
    • 77949419896 scopus 로고    scopus 로고
    • Radiologic and nuclear medicine studies in the United States and worldwide: Frequency, radiation dose, and comparison with other radiation sources19502007
    • F.A. Mettler, M. Bhargavan, and K. Faulkner Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources19502007 Radiology 253 2009 520 531
    • (2009) Radiology , vol.253 , pp. 520-531
    • Mettler, F.A.1    Bhargavan, M.2    Faulkner, K.3
  • 5
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • A.J. Einstein, M.J. Henzlova, and S. Rajagopalan Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography JAMA 298 2007 317 323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 6
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • A. Berrington de Gonzlez, M. Mahesh, and K.P. Kim Projected cancer risks from computed tomographic scans performed in the United States in 2007 Arch Intern Med 169 2009 2071 2077
    • (2009) Arch Intern Med , vol.169 , pp. 2071-2077
    • Berrington De Gonzlez, A.1    Mahesh, M.2    Kim, K.P.3
  • 7
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • F.A. Mettler, W. Huda, T.T. Yoshizumi, and M. Mahesh Effective doses in radiology and diagnostic nuclear medicine: a catalog Radiology 248 2008 254 263
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler, F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 8
    • 34948887091 scopus 로고    scopus 로고
    • Effective dose: How should it be applied to medical exposures?
    • C.J. Martin Effective dose: how should it be applied to medical exposures? Br J Radiol 80 2007 639 647
    • (2007) Br J Radiol , vol.80 , pp. 639-647
    • Martin, C.J.1
  • 9
    • 67349168167 scopus 로고    scopus 로고
    • SCCT guidelines for performance of coronary computed tomographic angiography: A report of the Society of Cardiovascular Computed Tomography guidelines committee
    • S. Abbara, A. Arbab-Zadeh, and T.Q. Callister SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography guidelines committee J Cardiovasc Comput Tomogr 3 2009 190 204
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 190-204
    • Abbara, S.1    Arbab-Zadeh, A.2    Callister, T.Q.3
  • 10
    • 63249127583 scopus 로고    scopus 로고
    • SCCT guidelines for the interpretation and reporting of coronary computed tomographc angiography
    • G.L. Raff, A. Abidov, and S. Achenbach SCCT guidelines for the interpretation and reporting of coronary computed tomographc angiography J Cardiovasc Comput Tomogr 3 2009 122 136
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 122-136
    • Raff, G.L.1    Abidov, A.2    Achenbach, S.3
  • 11
    • 57949086584 scopus 로고    scopus 로고
    • ACC/AHA/ACR/ASE/ASNC/HRS/NASCI/RSNA/SAIP/SCAI/SCCT/SCMR/SIR 2008 key data elements and definitions of cardiac imaging: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Data Standards
    • Writing Committee to Develop Clinical Data Standards for Cardiac Imaging
    • R.C. Hendel, M.J. Budoff, and J.F. Cardella ACC/AHA/ACR/ASE/ASNC/HRS/ NASCI/RSNA/SAIP/SCAI/SCCT/SCMR/SIR 2008 key data elements and definitions of cardiac imaging A report of the American College of Cardiology/American Heart Association Task Force on Clinical Data Standards (Writing Committee to Develop Clinical Data Standards for Cardiac Imaging) J Am Coll Cardiol 53 2009 91 124
    • (2009) J Am Coll Cardiol , vol.53 , pp. 91-124
    • Hendel, R.C.1    Budoff, M.J.2    Cardella, J.F.3
  • 12
    • 33845786010 scopus 로고    scopus 로고
    • Facts and controversies about radiation exposure, part 2: Low-level exposures and cancer risk
    • J. Strzelczyk, J. Damilakis, M.V. Marx, and K.J. Macura Facts and controversies about radiation exposure, part 2: low-level exposures and cancer risk J Am Coll Radiol 4 2007 32 39
    • (2007) J Am Coll Radiol , vol.4 , pp. 32-39
    • Strzelczyk, J.1    Damilakis, J.2    Marx, M.V.3    MacUra, K.J.4
  • 13
    • 64949191402 scopus 로고    scopus 로고
    • The linear no-threshold relationship is inconsistent with radiation biologic and experimental data
    • M. Tubiana, L.R. Feinendegen, C. Yang, and J.M. Kaminski The linear no-threshold relationship is inconsistent with radiation biologic and experimental data Radiology 251 2009 13 22
    • (2009) Radiology , vol.251 , pp. 13-22
    • Tubiana, M.1    Feinendegen, L.R.2    Yang, C.3    Kaminski, J.M.4
  • 14
    • 64949094007 scopus 로고    scopus 로고
    • Risks associated with low doses or low dose rates of ionizing radiation: Why linearity may be (almost) the best we can do
    • M.P. Little, R. Wakeford, E.J. Tawn, S.D. Boufffler, and A. Berrington de Gonzalez Risks associated with low doses or low dose rates of ionizing radiation: why linearity may be (almost) the best we can do Radiology 251 2009 6 12
    • (2009) Radiology , vol.251 , pp. 6-12
    • Little, M.P.1    Wakeford, R.2    Tawn, E.J.3    Boufffler, S.D.4    Berrington De Gonzalez, A.5
  • 15
    • 61849088894 scopus 로고    scopus 로고
    • Ionizing radiation in cardiac imaging: A science advisory from the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention
    • T.C. Gerber, J.J. Carr, and A.E. Arai Ionizing radiation in cardiac imaging A science advisory from the American Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention Circulation 119 2009 1056 1065
    • (2009) Circulation , vol.119 , pp. 1056-1065
    • Gerber, T.C.1    Carr, J.J.2    Arai, A.E.3
  • 16
    • 67650469121 scopus 로고    scopus 로고
    • Coronary artery calcification screening: Estimated radiation dose and cancer risk
    • K.P. Kim, A.J. Einstein, and A. Berrington de Gonzlez Coronary artery calcification screening: estimated radiation dose and cancer risk Arch Intern Med 169 2009 1188 1194
    • (2009) Arch Intern Med , vol.169 , pp. 1188-1194
    • Kim, K.P.1    Einstein, A.J.2    Berrington De Gonzlez, A.3
  • 17
    • 67849090531 scopus 로고    scopus 로고
    • Options for reducing patient radiation dose with cardiovascular computed tomography
    • S. Halliburton Options for reducing patient radiation dose with cardiovascular computed tomography Int J Cardiovasc Imaging 25 2009 153 164
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 153-164
    • Halliburton, S.1
  • 18
    • 33749061448 scopus 로고    scopus 로고
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group
    • American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and the Society of Interventional Radiology
    • R.C. Hendel, M.R. Patel, and C.M. Kramer ACCF/ACR/SCCT/SCMR/ASNC/NASCI/ SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and the Society of Interventional Radiology J Am Coll Cardiol 48 2006 1475 1497
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1475-1497
    • Hendel, R.C.1    Patel, M.R.2    Kramer, C.M.3
  • 19
    • 57449111669 scopus 로고    scopus 로고
    • Limitations of computed tomography coronary angiography
    • S.E. Nissen Limitations of computed tomography coronary angiography J Am Coll Cardiol 52 2008 2145 2147
    • (2008) J Am Coll Cardiol , vol.52 , pp. 2145-2147
    • Nissen, S.E.1
  • 20
    • 34347231277 scopus 로고    scopus 로고
    • ACCF/ASE/ACEP/ASNC/SCAI/SCCT/SCMR 2007 appropriateness criteria for transthoracic and transesophageal echocardiography
    • P.S. Douglas, B. Khandheria, and R.F. Stainback ACCF/ASE/ACEP/ASNC/SCAI/ SCCT/SCMR 2007 appropriateness criteria for transthoracic and transesophageal echocardiography J Am Coll Cardiol 50 2007 187 204
    • (2007) J Am Coll Cardiol , vol.50 , pp. 187-204
    • Douglas, P.S.1    Khandheria, B.2    Stainback, R.F.3
  • 21
    • 66149093844 scopus 로고    scopus 로고
    • ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American college of Cardiology Foundation Appropriate Use Criteria Task Force
    • the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine
    • R.C. Hendel, D.S. Berman, and M.F. Di Carli ACCF/ASNC/ACR/AHA/ASE/SCCT/ SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American college of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine J Am Coll Cardiol 53 2009 2201 2209
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2201-2209
    • Hendel, R.C.1    Berman, D.S.2    Di Carli, M.F.3
  • 22
    • 0033522279 scopus 로고    scopus 로고
    • ACC/AHA guidelines for coronary angiography: Executive summary and recommendations: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography)
    • P.J. Scanlon, D.P. Faxon, and A.M. Audet ACC/AHA guidelines for coronary angiography: executive summary and recommendations A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) Circulation 99 1999 2345 2357
    • (1999) Circulation , vol.99 , pp. 2345-2357
    • Scanlon, P.J.1    Faxon, D.P.2    Audet, A.M.3
  • 23
    • 0030787769 scopus 로고    scopus 로고
    • ACC/AHA guidelines for exercise testing: Executive summary: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing)
    • R.J. Gibbons, G.J. Balady, and J.W. Beasley ACC/AHA guidelines for exercise testing: executive summary A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing) J Am Coll Cardiol 30 1997 260 315
    • (1997) J Am Coll Cardiol , vol.30 , pp. 260-315
    • Gibbons, R.J.1    Balady, G.J.2    Beasley, J.W.3
  • 24
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • J.P. Earls, E.L. Berman, and B.A. Urban Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose Radiology 246 2008 742 753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 25
    • 70349675803 scopus 로고    scopus 로고
    • Prospective and retrospective ECG gating for thoracic CT angiography: A comparative study
    • W. Wu, J. Budovec, and W.D. Foley Prospective and retrospective ECG gating for thoracic CT angiography: a comparative study AJR Am J Roentgenol 193 2009 955 963
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 955-963
    • Wu, W.1    Budovec, J.2    Foley, W.D.3
  • 26
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
    • M. Lell, M. Marwan, and T. Schepis Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience Eur Radiol 19 2009 2576 2583
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 27
    • 71449119488 scopus 로고    scopus 로고
    • Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: First experience
    • S. Leschka, P. Stolzmann, and L. Desbiolles Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience Eur Radiol 19 2009 2896 2903
    • (2009) Eur Radiol , vol.19 , pp. 2896-2903
    • Leschka, S.1    Stolzmann, P.2    Desbiolles, L.3
  • 28
    • 67849105498 scopus 로고    scopus 로고
    • Prospectively gated low-dose CCTA: 24 months experience in more than 2000 clinical cases
    • J.P. Earls, and E.C. Schrack Prospectively gated low-dose CCTA: 24 months experience in more than 2000 clinical cases Int J Cardiovasc Imaging 25 2009 177 187
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 177-187
    • Earls, J.P.1    Schrack, E.C.2
  • 29
    • 68549088465 scopus 로고    scopus 로고
    • Impact of a reduced tube voltage on CT angiography and radiation dose: Results of the PROTECTION i study
    • B. Bischoff, F. Hein, and T. Meyer Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study J Am Coll Cardiol Img 2 2009 940 946
    • (2009) J Am Coll Cardiol Img , vol.2 , pp. 940-946
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 30
    • 73449146325 scopus 로고    scopus 로고
    • Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study
    • G.M. Feuchtner, D. Jodocy, and A. Klauser Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study Eur J Radiol 12 2009 1016
    • (2009) Eur J Radiol , vol.12 , pp. 1016
    • Feuchtner, G.M.1    Jodocy, D.2    Klauser, A.3
  • 31
    • 34249087431 scopus 로고    scopus 로고
    • Estimating radiation doses from multidetector CT using Monte Carlo simulations: Effects of different size voxelized patient models on magnitudes of organ and effect dose
    • J.J. DeMarco, C.H. Cagnon, and D.D. Cody Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effect dose Phys Med Biol 52 2007 2583 2597
    • (2007) Phys Med Biol , vol.52 , pp. 2583-2597
    • Demarco, J.J.1    Cagnon, C.H.2    Cody, D.D.3
  • 32
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • J. Hausleiter, T. Meyer, and F. Hermann Estimated radiation dose associated with cardiac CT angiography JAMA 301 2009 500 507
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 33
    • 84928096460 scopus 로고    scopus 로고
    • Tracking radiation exposure from diagnostic imaging devices at the NIH
    • R.D. Neumann, and D.A. Bluemke Tracking radiation exposure from diagnostic imaging devices at the NIH J Am Coll Radiol 7 2010 87 89
    • (2010) J Am Coll Radiol , vol.7 , pp. 87-89
    • Neumann, R.D.1    Bluemke, D.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.