Volumn 40, Issue 11, 2010, Pages 1744-1747

The use of breast shielding for dose reduction in pediatric CT: Arguments against the proposition

Author keywords

[No Author keywords available]

Indexed keywords

BISMUTH;

EID: 78650202675     PISSN: 03010449     EISSN: 14321998     Source Type: Journal    
DOI: 10.1007/s00247-010-1808-2     Document Type: Article
Times cited : (29)

References (10)
  • 1
    • 0030688058 scopus 로고    scopus 로고
    • The breast: Inplane x-ray protection during diagnostic thoracic CT - shielding with bismuth radioprotective garments
    • Hopper KD, King SH, Lobell ME et al (1997) The breast: Inplane x-ray protection during diagnostic thoracic CT - shielding with bismuth radioprotective garments. Radiology 205:853-858
    • (1997) Radiology , vol.205 , pp. 853-858
    • Hopper, K.D.1    King, S.H.2    Lobell, M.E.3
  • 2
    • 0037305664 scopus 로고    scopus 로고
    • In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data
    • Fricke BL, Donnelly LF, Frush DP et al (2003) In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data. AJR 180:407-411
    • (2003) AJR , vol.180 , pp. 407-411
    • Fricke, B.L.1    Donnelly, L.F.2    Frush, D.P.3
  • 3
    • 33846634112 scopus 로고    scopus 로고
    • Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose
    • Yilmaz MH, Albayram S, Yasar D et al (2007) Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose. J Comput Assist Tomogr 31:138-142
    • (2007) J Comput Assist Tomogr , vol.31 , pp. 138-142
    • Yilmaz, M.H.1    Albayram, S.2    Yasar, D.3
  • 4
    • 33845942313 scopus 로고    scopus 로고
    • Coronary calcium scoring with MDCT: The radiation dose to the breast and the effectiveness of bismuth breast shield
    • Yilmaz MH, Yasar D, Albayram S et al (2007) Coronary calcium scoring with MDCT: The radiation dose to the breast and the effectiveness of bismuth breast shield. Eur J Radiol 61:139-143
    • (2007) Eur J Radiol , vol.61 , pp. 139-143
    • Yilmaz, M.H.1    Yasar, D.2    Albayram, S.3
  • 5
    • 66749091803 scopus 로고    scopus 로고
    • In-plane shielding for CT: Effect of off-centering, automatic exposure control and shield-tosurface distance
    • Kalra MK, Dang P, Singh S et al (2009) In-plane shielding for CT: Effect of off-centering, automatic exposure control and shield-tosurface distance. Korean J Radiol 10:156-163
    • (2009) Korean J Radiol , vol.10 , pp. 156-163
    • Kalra, M.K.1    Dang, P.2    Singh, S.3
  • 6
    • 78650201654 scopus 로고    scopus 로고
    • Reducing mAs is as effective as a bismuth breast shield to minimize breast dose for chest CT when keeping mediastinal noise constant
    • Berland LL, Yester MV, Fitzpatrick AF (2009) Reducing mAs is as effective as a bismuth breast shield to minimize breast dose for chest CT when keeping mediastinal noise constant. Proceedings of RSNA 2009 Abstract (SSA04-05)
    • (2009) Proceedings of RSNA 2009 Abstract (SSA04-05)
    • Berland, L.L.1    Yester, M.V.2    Fitzpatrick, A.F.3
  • 7
    • 33748454831 scopus 로고    scopus 로고
    • Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    • Geleijns J, Salvado AM, Veldkamp WJ et al (2006) Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol 16:2334-2340
    • (2006) Eur Radiol , vol.16 , pp. 2334-2340
    • Geleijns, J.1    Salvado, A.M.2    Veldkamp, W.J.3
  • 8
    • 48949116166 scopus 로고    scopus 로고
    • Reduction of dose to the female breast in thoracic CT: A comparison of standard-protocol, bismuthshielded, partial and tube-current-modulated CT examinations
    • Vollmar SV, Kalender WA (2008) Reduction of dose to the female breast in thoracic CT: A comparison of standard-protocol, bismuthshielded, partial and tube-current-modulated CT examinations. Eur Radiol 18:1674-1682
    • (2008) Eur Radiol , vol.18 , pp. 1674-1682
    • Vollmar, S.V.1    Kalender, W.A.2
  • 9
    • 43149112505 scopus 로고    scopus 로고
    • The 2007 recommendations of the international commission on radiological protection
    • ICRP
    • ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103
    • (2007) ICRP Publication , vol.103
  • 10
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • McCollough CH, Bruesewitz MR, Kofler JM Jr (2006) CT dose reduction and dose management tools: Overview of available options. Radiographics 26:503-512
    • (2006) Radiographics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.