Volumn 191, Issue 6, 2008, Pages 1684-1689

Influence of calcifications on diagnostic accuracy of coronary CT angiography using prospective ECG triggering

Author keywords

Calcifications; CT coronary angiography; Diagnostic accuracy; Low dose; Prospective ECG triggering

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY CALCIFICATION; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; CONVENTIONAL ANGIOGRAPHY; DIAGNOSTIC ACCURACY; ELECTROCARDIOGRAM; FEMALE; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY;

EID: 57149117486     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.4040     Document Type: Article
Times cited : (58)

References (26)
  • 1
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: First experience
    • Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 2005; 26:1482-1487
    • (2005) Eur Heart J , vol.26 , pp. 1482-1487
    • Leschka, S.1    Alkadhi, H.2    Plass, A.3
  • 2
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005; 46:552-557
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 3
    • 26844549564 scopus 로고    scopus 로고
    • High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography
    • Mollet NR, Cademartiri F, van Mieghem CA, et al. High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 2005; 112:2318-2323
    • (2005) Circulation , vol.112 , pp. 2318-2323
    • Mollet, N.R.1    Cademartiri, F.2    van Mieghem, C.A.3
  • 4
    • 33947399137 scopus 로고    scopus 로고
    • Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control
    • Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 2006; 16:2739-2747
    • (2006) Eur Radiol , vol.16 , pp. 2739-2747
    • Scheffel, H.1    Alkadhi, H.2    Plass, A.3
  • 5
    • 37449003958 scopus 로고    scopus 로고
    • Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
    • Ropers U, Ropers D, Pflederer T, et al. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 2007; 50:2393-2398
    • (2007) J Am Coll Cardiol , vol.50 , pp. 2393-2398
    • Ropers, U.1    Ropers, D.2    Pflederer, T.3
  • 6
    • 38449089116 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
    • Johnson TR, Nikolaou K, Busch S, et al. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol 2007; 42:684-691
    • (2007) Invest Radiol , vol.42 , pp. 684-691
    • Johnson, T.R.1    Nikolaou, K.2    Busch, S.3
  • 7
    • 41149084470 scopus 로고    scopus 로고
    • Dual-source computed tomography coronary angiography: Influence of obesity, calcium load, and heart rate on diagnostic accuracy
    • Alkadhi H, Scheffel H, Desbiolles L, et al. Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. Eur Heart J 2008; 29:766-776
    • (2008) Eur Heart J , vol.29 , pp. 766-776
    • Alkadhi, H.1    Scheffel, H.2    Desbiolles, L.3
  • 8
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • Earls JP, Berman EL, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 2008; 246:742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 9
    • 40849085022 scopus 로고    scopus 로고
    • Predicting success of prospective and retrospective gating with dual-source coronary computed tomography angiography: Development of selection criteria and initial experience
    • Gutstein A, Wolak A, Lee C, et al. Predicting success of prospective and retrospective gating with dual-source coronary computed tomography angiography: development of selection criteria and initial experience. J Cardiovasc CT 2008; 2:81-90
    • (2008) J Cardiovasc CT , vol.2 , pp. 81-90
    • Gutstein, A.1    Wolak, A.2    Lee, C.3
  • 10
    • 38849093344 scopus 로고    scopus 로고
    • Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: A phantom study
    • Horiguchi J, Kiguchi M, Fujioka C, et al. Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: a phantom study. AJR 2008; 190:315-320
    • (2008) AJR , vol.190 , pp. 315-320
    • Horiguchi, J.1    Kiguchi, M.2    Fujioka, C.3
  • 11
    • 50249178242 scopus 로고    scopus 로고
    • Low-dose CT coronary angiography in the step-and-shoot mode: Diagnostic performance
    • Scheffel H, Alkadhi H, Leschka S, et al. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 2008; 94:1132-1137
    • (2008) Heart , vol.94 , pp. 1132-1137
    • Scheffel, H.1    Alkadhi, H.2    Leschka, S.3
  • 12
    • 40849117981 scopus 로고    scopus 로고
    • The revival of step-and-shoot computed tomography coronary angiography: Benefits and open questions
    • Alkadhi H. The revival of step-and-shoot computed tomography coronary angiography: benefits and open questions. J Cardiovasc CT 2008; 2:91-92
    • (2008) J Cardiovasc CT , vol.2 , pp. 91-92
    • Alkadhi, H.1
  • 13
    • 1642389455 scopus 로고    scopus 로고
    • Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004; 231:169-174
    • (2004) Radiology , vol.231 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.F.5
  • 14
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006; 16:256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 15
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease: Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975; 51:5-40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 17
    • 34547792220 scopus 로고    scopus 로고
    • Reliable high-speed coronary computed tomography in symptomatic patients
    • Weustink AC, Meijboom WB, Mollet NR, et al. Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 2007; 50:786-794
    • (2007) J Am Coll Cardiol , vol.50 , pp. 786-794
    • Weustink, A.C.1    Meijboom, W.B.2    Mollet, N.R.3
  • 18
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002; 106:2051-2054
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3    Raaijmakers, R.4    Pattynama, P.M.5    de Feyter, P.J.6
  • 19
    • 0003892109 scopus 로고    scopus 로고
    • Menzel H, Schibilla H, Teunen D, eds, Luxembourg: European Commission, Publication No. EUR 16262 EN
    • Menzel H, Schibilla H, Teunen D, eds. European guidelines on quality criteria for computed tomography. Luxembourg: European Commission, 2000; Publication No. EUR 16262 EN
    • (2000) European guidelines on quality criteria for computed tomography
  • 20
    • 39049158286 scopus 로고    scopus 로고
    • Radiation dose estimates in dual-source computed tomography coronary angiography
    • Stolzmann P, Scheffel H, Schertler T, et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 2008; 18:592-599
    • (2008) Eur Radiol , vol.18 , pp. 592-599
    • Stolzmann, P.1    Scheffel, H.2    Schertler, T.3
  • 21
    • 33750292412 scopus 로고    scopus 로고
    • Noninvasive coronary angiography with 64-section CT: Effect of average heart rate and heart rate variability on image quality
    • Leschka S, Wildermuth S, Boehm T, et al. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 2006; 241:378-385
    • (2006) Radiology , vol.241 , pp. 378-385
    • Leschka, S.1    Wildermuth, S.2    Boehm, T.3
  • 22
    • 36448991889 scopus 로고    scopus 로고
    • Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT
    • Seifarth H, Wienbeck S, Püsken M, et al. Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR 2007; 189:1317-1323
    • (2007) AJR , vol.189 , pp. 1317-1323
    • Seifarth, H.1    Wienbeck, S.2    Püsken, M.3
  • 23
    • 34548256734 scopus 로고    scopus 로고
    • Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability
    • Matt D, Scheffel H, Leschka S, et al. Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR 2007; 189:567-573
    • (2007) AJR , vol.189 , pp. 567-573
    • Matt, D.1    Scheffel, H.2    Leschka, S.3
  • 24
    • 33744967019 scopus 로고    scopus 로고
    • Ong TK, Chin SP, Liew CK, et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 2006; 151:1323.e1-1323.e6
    • Ong TK, Chin SP, Liew CK, et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 2006; 151:1323.e1-1323.e6
  • 25
    • 34249023378 scopus 로고    scopus 로고
    • Dose performance of a 64-channel dual-source CT scanner
    • McCollough CH, Primak AN, Saba O, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology 2007; 243:775-784
    • (2007) Radiology , vol.243 , pp. 775-784
    • McCollough, C.H.1    Primak, A.N.2    Saba, O.3
  • 26
    • 33745546975 scopus 로고    scopus 로고
    • MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose
    • Abada HT, Larchez C, Daoud B, Sigal-Cinqualbre A, Paul JF. MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR 2006; 186[6 suppl 2]:S387-S390
    • (2006) AJR , vol.186 , Issue.6 SUPPL. 2
    • Abada, H.T.1    Larchez, C.2    Daoud, B.3    Sigal-Cinqualbre, A.4    Paul, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.