메뉴 건너뛰기




Volumn 11, Issue 2, 2011, Pages 148-156

Chip-based detection system for the on-site analysis of animal diseases

Author keywords

Animal disease; DNA chip with electrical detection; On site testing

Indexed keywords

ANIMAL DISEASE; AUTOMATED ANALYSIS; CHIP TECHNOLOGY; DETECTION SYSTEM; DNA AMPLIFICATION; DNA CHIP; DNA DETECTION; ELECTRICAL DETECTION; ENERGY REQUIREMENTS; FOOT-AND-MOUTH DISEASE VIRUS; ON-SITE ANALYSIS; ON-SITE TESTING; PCR CHIPS; PCR PRODUCTS; ROBUST SYSTEMS; SEQUENCE ANALYSIS; SPECIFIC SEQUENCES; THERMOCYCLERS;

EID: 79955444810     PISSN: 16180240     EISSN: 16182863     Source Type: Journal    
DOI: 10.1002/elsc.201000046     Document Type: Article
Times cited : (17)

References (37)
  • 1
    • 77958134696 scopus 로고    scopus 로고
    • Options for decentralized testing of suspected secondary outbreaks of foot-and-mouth disease
    • Sammin, D., Ryan, E., Ferris, N. P., King, D. P. et al., Options for decentralized testing of suspected secondary outbreaks of foot-and-mouth disease. Transboundary Emerging Diseases 2010, 57, 237-243.
    • (2010) Transboundary Emerging Diseases , vol.57 , pp. 237-243
    • Sammin, D.1    Ryan, E.2    Ferris, N.P.3    King, D.P.4
  • 3
    • 44649166350 scopus 로고    scopus 로고
    • A flexible piezoelectric sensor for microfluidic applications using polyvinylidene fluoride
    • Chang, W.-Y., Chu, C.-H., Lin, Y.-C., A flexible piezoelectric sensor for microfluidic applications using polyvinylidene fluoride. IEEE Sens. J. 2008, 8, 495-500.
    • (2008) IEEE Sens. J. , vol.8 , pp. 495-500
    • Chang, W.-Y.1    Chu, C.-H.2    Lin, Y.-C.3
  • 4
    • 23144462014 scopus 로고    scopus 로고
    • Go with the microflow
    • Clayton, J., Go with the microflow. Nat. Methods 2005, 2, 621-627.
    • (2005) Nat. Methods , vol.2 , pp. 621-627
    • Clayton, J.1
  • 5
    • 34548077793 scopus 로고    scopus 로고
    • Microfluidic platforms for lab-on-a-chip applications
    • Haeberle, S., Zengerle, R., Microfluidic platforms for lab-on-a-chip applications. Lab Chip 2007, 7, 1094-1110.
    • (2007) Lab Chip , vol.7 , pp. 1094-1110
    • Haeberle, S.1    Zengerle, R.2
  • 6
    • 79955389694 scopus 로고    scopus 로고
    • DNA chip, DNA chip kit, and method of manufacturing the DNA chip. Application: US US: (S. Korea).
    • Kim, W.-S., Chi, S.-M., Hah, J.-H., Kim, K.-S., DNA chip, DNA chip kit, and method of manufacturing the DNA chip. Application: US US: (S. Korea). 2007, p. 26.
    • (2007) , pp. 26
    • Kim, W.-S.1    Chi, S.-M.2    Hah, J.-H.3    Kim, K.-S.4
  • 7
    • 52449121487 scopus 로고    scopus 로고
    • Sensitive on-chip quantitative real-time PCR performed on an adaptable and robust platform
    • Lund-Olesen, T., Dufva, M., Dahl, J., Collas, P., Hansen, M., Sensitive on-chip quantitative real-time PCR performed on an adaptable and robust platform. Biomed. Microdevices 2008, 10, 769-776.
    • (2008) Biomed. Microdevices , vol.10 , pp. 769-776
    • Lund-Olesen, T.1    Dufva, M.2    Dahl, J.3    Collas, P.4    Hansen, M.5
  • 8
    • 70349303094 scopus 로고    scopus 로고
    • Low cost and manufacturable complete microTAS for detecting bacteria
    • Sauer-Budge, A. F., Mirer, P., Chatterjee, A., Klapperich, C. M. et al., Low cost and manufacturable complete microTAS for detecting bacteria. Lab Chip 2009, 9, 2803-2810.
    • (2009) Lab Chip , vol.9 , pp. 2803-2810
    • Sauer-Budge, A.F.1    Mirer, P.2    Chatterjee, A.3    Klapperich, C.M.4
  • 9
    • 69549122660 scopus 로고    scopus 로고
    • Lab-on-a-chip PCR in continuous flow: an ultrafast analytical tool for B-agents
    • Gaertner, C., Becker, H., Clemens, T., Klemm, R. et al., Lab-on-a-chip PCR in continuous flow: an ultrafast analytical tool for B-agents. Proc. SPIE 2009, 7304, 73040G/1-73040G/6.
    • (2009) Proc. SPIE , vol.7304
    • Gaertner, C.1    Becker, H.2    Clemens, T.3    Klemm, R.4
  • 10
    • 77953942156 scopus 로고    scopus 로고
    • Miniature on-chip detection of unpurified methicillin-resistant Staphylococcus aureus (MRSA) DNA using real-time PCR
    • House, D. L., Chon, C.-H., Creech, C. B., Skaar, E. P., Li, D.-Q., Miniature on-chip detection of unpurified methicillin-resistant Staphylococcus aureus (MRSA) DNA using real-time PCR. J. Biotechnol. 2010, 146, 93-99.
    • (2010) J. Biotechnol. , vol.146 , pp. 93-99
    • House, D.L.1    Chon, C.-H.2    Creech, C.B.3    Skaar, E.P.4    Li, D.-Q.5
  • 11
    • 71749085611 scopus 로고    scopus 로고
    • Modular plastic chip for one-shot human papillomavirus diagnostic analysis
    • Vecchio, G., Sabella, S., Tagliaferro, L., Menegazzi, P. et al., Modular plastic chip for one-shot human papillomavirus diagnostic analysis. Anal. Biochem. 2010, 397, 53-59.
    • (2010) Anal. Biochem. , vol.397 , pp. 53-59
    • Vecchio, G.1    Sabella, S.2    Tagliaferro, L.3    Menegazzi, P.4
  • 12
    • 51349118322 scopus 로고    scopus 로고
    • Optimization of a microfluidic cartridge for lab-on-a-chip (LOC) application and bio-testing for DNA/RNA extraction
    • Xie, L., Premachandran, C. S., Chew, M., Chong, S. C. et al., Optimization of a microfluidic cartridge for lab-on-a-chip (LOC) application and bio-testing for DNA/RNA extraction. IEEE Electron. Compon. Technol. Conf. 2008, 58, 1310-1316.
    • (2008) IEEE Electron. Compon. Technol. Conf. , vol.58 , pp. 1310-1316
    • Xie, L.1    Premachandran, C.S.2    Chew, M.3    Chong, S.C.4
  • 14
    • 66149128058 scopus 로고    scopus 로고
    • Flexible biochips for detection of biomolecules
    • Peter, M., Schuler, T., Furthner, F., Rensing, P. A. et al., Flexible biochips for detection of biomolecules. Langmuir 2009, 25, 5384-5390.
    • (2009) Langmuir , vol.25 , pp. 5384-5390
    • Peter, M.1    Schuler, T.2    Furthner, F.3    Rensing, P.A.4
  • 15
    • 0031800106 scopus 로고    scopus 로고
    • Microarrays: biotechnology's discovery platform for functional genomics
    • Schena, M., Heller, R. A., Theriault, T. P., Konrad, K. et al., Microarrays: biotechnology's discovery platform for functional genomics. Trends Biotechnol. 1998, 16, 301-306.
    • (1998) Trends Biotechnol. , vol.16 , pp. 301-306
    • Schena, M.1    Heller, R.A.2    Theriault, T.P.3    Konrad, K.4
  • 16
    • 16244384998 scopus 로고    scopus 로고
    • Planar chip device for PCR and hybridization with surface acoustic wave pump
    • Guttenberg, Z., Mueller, H., Habermueller, H., Geisbauer, A. et al., Planar chip device for PCR and hybridization with surface acoustic wave pump. Lab Chip 2005, 5, 308-317.
    • (2005) Lab Chip , vol.5 , pp. 308-317
    • Guttenberg, Z.1    Mueller, H.2    Habermueller, H.3    Geisbauer, A.4
  • 17
    • 42549140252 scopus 로고    scopus 로고
    • Growth and percolation of metal nanostructures in electrode gaps leading to conductive paths for electrical DNA analysis
    • Festag, G., Schueler, T., Moeller, R., Csaki, A., Fritzsche, W., Growth and percolation of metal nanostructures in electrode gaps leading to conductive paths for electrical DNA analysis. Nanotechnology 2008, 19, 125303/1-125303/9.
    • (2008) Nanotechnology , vol.19
    • Festag, G.1    Schueler, T.2    Moeller, R.3    Csaki, A.4    Fritzsche, W.5
  • 19
    • 37449021541 scopus 로고    scopus 로고
    • Electrical DNA-chip-based identification of different species of the genus Kitasatospora
    • Moeller, R., Schueler, T., Guenther, S., Carlsohn, M. R. et al., Electrical DNA-chip-based identification of different species of the genus Kitasatospora. Appl. Microbiol. Biotechnol. 2008, 77, 1181-1188.
    • (2008) Appl. Microbiol. Biotechnol. , vol.77 , pp. 1181-1188
    • Moeller, R.1    Schueler, T.2    Guenther, S.3    Carlsohn, M.R.4
  • 20
    • 70349384628 scopus 로고    scopus 로고
    • A review of RT-PCR technologies used in veterinary virology and disease control: sensitive and specific diagnosis of five livestock diseases notifiable to the World Organisation for Animal Health
    • Hoffmann, B., Beer, M., Reid, S. M., Mertens, P. et al., A review of RT-PCR technologies used in veterinary virology and disease control: sensitive and specific diagnosis of five livestock diseases notifiable to the World Organisation for Animal Health. Vet. Microbiol. 2009, 139, 1-23.
    • (2009) Vet. Microbiol. , vol.139 , pp. 1-23
    • Hoffmann, B.1    Beer, M.2    Reid, S.M.3    Mertens, P.4
  • 21
    • 33748788597 scopus 로고    scopus 로고
    • Foot-and-mouth disease virus: a first inter-laboratory comparison trial to evaluate virus isolation and RT-PCR detection methods
    • Ferris, N. P., King, D. P., Reid, S. M., Hutchings, G. H. et al., Foot-and-mouth disease virus: a first inter-laboratory comparison trial to evaluate virus isolation and RT-PCR detection methods. Vet. Microbiol. 2006, 117, 130-140.
    • (2006) Vet. Microbiol. , vol.117 , pp. 130-140
    • Ferris, N.P.1    King, D.P.2    Reid, S.M.3    Hutchings, G.H.4
  • 22
    • 0037291996 scopus 로고    scopus 로고
    • Evaluation of automated RT-PCR to accelerate the laboratory diagnosis of foot-and-mouth disease virus
    • Reid, S. M., Grierson, S. S., Ferris, N. P., Hutchings, G. H., Alexandersen, S., Evaluation of automated RT-PCR to accelerate the laboratory diagnosis of foot-and-mouth disease virus. J. Virol. Methods 2003, 107, 129-139.
    • (2003) J. Virol. Methods , vol.107 , pp. 129-139
    • Reid, S.M.1    Grierson, S.S.2    Ferris, N.P.3    Hutchings, G.H.4    Alexandersen, S.5
  • 23
    • 4544300183 scopus 로고    scopus 로고
    • Quantitative analysis of foot-and-mouth disease virus RNA loads in bovine tissues: Implications for the site of viral persistence
    • Zhang, Z., Alexandersen, S., Quantitative analysis of foot-and-mouth disease virus RNA loads in bovine tissues: Implications for the site of viral persistence. J. Gen. Virol. 2004, 85, 2567-2575.
    • (2004) J. Gen. Virol. , vol.85 , pp. 2567-2575
    • Zhang, Z.1    Alexandersen, S.2
  • 24
    • 35748979475 scopus 로고    scopus 로고
    • Performance of a foot-and-mouth disease virus reverse transcription-polymerase chain reaction with amplification controls between three real-time instruments
    • Moniwa, M., Clavijo, A., Li, M., Collignon, B., Kitching, P. R., Performance of a foot-and-mouth disease virus reverse transcription-polymerase chain reaction with amplification controls between three real-time instruments. J. Vet. Diagn. Invest. 2007, 19, 9-20.
    • (2007) J. Vet. Diagn. Invest. , vol.19 , pp. 9-20
    • Moniwa, M.1    Clavijo, A.2    Li, M.3    Collignon, B.4    Kitching, P.R.5
  • 25
    • 70350728940 scopus 로고    scopus 로고
    • Simple and rapid lateral-flow assay for the detection of foot-and-mouth disease virus
    • Oem, J. K., Ferris, N. P., Lee, K.-N., Joo, Y.-S. et al., Simple and rapid lateral-flow assay for the detection of foot-and-mouth disease virus. Clin. Vaccine Immunol. 2009, 16, 1660-1664.
    • (2009) Clin. Vaccine Immunol. , vol.16 , pp. 1660-1664
    • Oem, J.K.1    Ferris, N.P.2    Lee, K.-N.3    Joo, Y.-S.4
  • 26
    • 0035748880 scopus 로고    scopus 로고
    • Clinical picture and differential diagnosis of foot and mouth disease in cattle
    • Doll, K., Clinical picture and differential diagnosis of foot and mouth disease in cattle. Dtsch. Tierarztl. Wochenschr. 2001, 108, 494-498.
    • (2001) Dtsch. Tierarztl. Wochenschr. , vol.108 , pp. 494-498
    • Doll, K.1
  • 27
    • 34249070199 scopus 로고    scopus 로고
    • Implementation of a one-step real-time RT-PCR protocol for diagnosis of foot-and-mouth disease
    • Shaw, A. E., Reid, S. M., Ebert, K., Hutchings, G. H. et al., Implementation of a one-step real-time RT-PCR protocol for diagnosis of foot-and-mouth disease. J. Virol. Methods 2007, 143, 81-85.
    • (2007) J. Virol. Methods , vol.143 , pp. 81-85
    • Shaw, A.E.1    Reid, S.M.2    Ebert, K.3    Hutchings, G.H.4
  • 28
    • 2542483732 scopus 로고    scopus 로고
    • Investigations on the compatibility of chemically oxidized silicon (SiOx)-surfaces for applications towards chip-based polymerase chain reaction
    • Felbel, J., Bieber, I., Pipper, J., Kohler, J. M., Investigations on the compatibility of chemically oxidized silicon (SiOx)-surfaces for applications towards chip-based polymerase chain reaction. Chem. Eng. J. (Amsterdam, Neth.) 2004, 101, 333-338.
    • (2004) Chem. Eng. J. (Amsterdam, Neth.) , vol.101 , pp. 333-338
    • Felbel, J.1    Bieber, I.2    Pipper, J.3    Kohler, J.M.4
  • 30
    • 68049132852 scopus 로고    scopus 로고
    • A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA
    • Schueler, T., Kretschmer, R., Jessing, S., Urban, M. et al., A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA. Biosens. Bioelectron. 2009, 25, 15-21.
    • (2009) Biosens. Bioelectron. , vol.25 , pp. 15-21
    • Schueler, T.1    Kretschmer, R.2    Jessing, S.3    Urban, M.4
  • 32
    • 0023277545 scopus 로고
    • Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction
    • Chomczynski, P., Sacchi, N., Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction. Anal. Biochem. 1987, 162, 156-159.
    • (1987) Anal. Biochem. , vol.162 , pp. 156-159
    • Chomczynski, P.1    Sacchi, N.2
  • 33
    • 25144439135 scopus 로고    scopus 로고
    • Development of a Lightcycler-based reverse transcription polymerase chain reaction for the detection of foot-and-mouth disease virus
    • Oem, J. K., Kye, S. J., Lee, K. N., Kim, Y. J. et al., Development of a Lightcycler-based reverse transcription polymerase chain reaction for the detection of foot-and-mouth disease virus. J. Vet. Sci. 2005, 6, 207-212.
    • (2005) J. Vet. Sci. , vol.6 , pp. 207-212
    • Oem, J.K.1    Kye, S.J.2    Lee, K.N.3    Kim, Y.J.4
  • 34
    • 77956902264 scopus 로고    scopus 로고
    • Lambda exonuclease pre-treatment for improved DNA-chip performance depends on the relative probe-target position
    • Brinker, A., Schulze, H., Bachmann, T., Moeller, R., Lambda exonuclease pre-treatment for improved DNA-chip performance depends on the relative probe-target position. Biosens. Bioelectron. 2010, 26, 898-902.
    • (2010) Biosens. Bioelectron. , vol.26 , pp. 898-902
    • Brinker, A.1    Schulze, H.2    Bachmann, T.3    Moeller, R.4
  • 35
    • 35349011173 scopus 로고    scopus 로고
    • Metal nanoparticle-based detection for DNA analysis
    • Moeller, R., Fritzsche, W., Metal nanoparticle-based detection for DNA analysis. Curr. Pharm. Biotechnol. 2007, 8, 274-285.
    • (2007) Curr. Pharm. Biotechnol. , vol.8 , pp. 274-285
    • Moeller, R.1    Fritzsche, W.2
  • 36
    • 0037330131 scopus 로고    scopus 로고
    • A paralleled readout system for an electrical DNA-hybridization assay based on a microstructured electrode array
    • Urban, M., Moller, R., Fritzsche, W., A paralleled readout system for an electrical DNA-hybridization assay based on a microstructured electrode array. Rev. Sci. Instrum. 2003, 74, 1077-1081.
    • (2003) Rev. Sci. Instrum. , vol.74 , pp. 1077-1081
    • Urban, M.1    Moller, R.2    Fritzsche, W.3
  • 37
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • Sia, S. K., Whitesides, G. M., Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies. Electrophoresis 2003, 24, 3563-3576.
    • (2003) Electrophoresis , vol.24 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.