메뉴 건너뛰기




Volumn 14, Issue 2, 2010, Pages

Pitfalls in haemodynamic monitoring based on the arterial pressure waveform

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; BLOOD PRESSURE; BLOOD VESSEL TONE; DIASTOLIC BLOOD PRESSURE; FEMORAL ARTERY; HEART HEMODYNAMICS; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; HUMAN; INTENSIVE CARE UNIT; NOTE; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; PULSE PRESSURE; RADIAL ARTERY; SYSTOLIC BLOOD PRESSURE; VASOCONSTRICTION; VASODILATATION; BLOOD PRESSURE MEASUREMENT; CRITICAL ILLNESS; HEMODYNAMICS; METHODOLOGY; VITAL SIGN;

EID: 77957355322     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc8845     Document Type: Note
Times cited : (38)

References (15)
  • 1
    • 77951628544 scopus 로고    scopus 로고
    • Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo(R)-derived cardiac output measurements: a prospective comparison study
    • 2811929, 19900267, 10.1186/cc8161
    • Eleftheriadis S, Galatoudis Z, Didilis V, Bougioukas I, Schon J, Heinze H, Berger KU, Heringlake M. Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo(R)-derived cardiac output measurements: a prospective comparison study. Crit Care 2009, 13:R179. 2811929, 19900267, 10.1186/cc8161.
    • (2009) Crit Care , vol.13
    • Eleftheriadis, S.1    Galatoudis, Z.2    Didilis, V.3    Bougioukas, I.4    Schon, J.5    Heinze, H.6    Berger, K.U.7    Heringlake, M.8
  • 3
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • table of contents, 10.1213/ane.0b013e318168b309, 18420863
    • Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008, 106:1480-1486. table of contents, 10.1213/ane.0b013e318168b309, 18420863.
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Vallet, A.4    Cochard, J.F.5    Revel, P.6    Sztark, F.7
  • 4
    • 34548254794 scopus 로고    scopus 로고
    • Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
    • 10.1093/bja/aem177, 17611251
    • Sakka SG, Kozieras J, Thuemer O, van Hout N. Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007, 99:337-342. 10.1093/bja/aem177, 17611251.
    • (2007) Br J Anaesth , vol.99 , pp. 337-342
    • Sakka, S.G.1    Kozieras, J.2    Thuemer, O.3    van Hout, N.4
  • 5
    • 41949139754 scopus 로고    scopus 로고
    • Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients
    • 10.1093/bja/aem409, 18256056
    • Compton FD, Zukunft B, Hoffmann C, Zidek W, Schaefer JH. Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients. Br J Anaesth 2008, 100:451-456. 10.1093/bja/aem409, 18256056.
    • (2008) Br J Anaesth , vol.100 , pp. 451-456
    • Compton, F.D.1    Zukunft, B.2    Hoffmann, C.3    Zidek, W.4    Schaefer, J.H.5
  • 6
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • 10.1093/bja/ael341, 17218375
    • Mayer J, Boldt J, Schollhorn T, Rohm KD, Mengistu AM, Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007, 98:176-182. 10.1093/bja/ael341, 17218375.
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3    Rohm, K.D.4    Mengistu, A.M.5    Suttner, S.6
  • 7
    • 65649112876 scopus 로고    scopus 로고
    • Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis
    • 10.1053/j.jvca.2009.03.003, 19464625
    • Mayer J, Boldt J, Poland R, Peterson A, Manecke GR. Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth 2009, 23:401-406. 10.1053/j.jvca.2009.03.003, 19464625.
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 401-406
    • Mayer, J.1    Boldt, J.2    Poland, R.3    Peterson, A.4    Manecke, G.R.5
  • 8
    • 0034086529 scopus 로고    scopus 로고
    • Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass
    • 10.1016/S1053-0770(00)90124-1, 10890480
    • Chauhan S, Saxena N, Mehrotra S, Rao BH, Sahu M. Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass. J Cardiothorac Vasc Anesth 2000, 14:274-276. 10.1016/S1053-0770(00)90124-1, 10890480.
    • (2000) J Cardiothorac Vasc Anesth , vol.14 , pp. 274-276
    • Chauhan, S.1    Saxena, N.2    Mehrotra, S.3    Rao, B.H.4    Sahu, M.5
  • 11
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • 10.1097/00003246-199810000-00014, 9781720
    • Dorman T, Breslow MJ, Lipsett PA, Rosenberg JM, Balser JR, Almog Y, Rosenfeld BA. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998, 26:1646-1649. 10.1097/00003246-199810000-00014, 9781720.
    • (1998) Crit Care Med , vol.26 , pp. 1646-1649
    • Dorman, T.1    Breslow, M.J.2    Lipsett, P.A.3    Rosenberg, J.M.4    Balser, J.R.5    Almog, Y.6    Rosenfeld, B.A.7
  • 12
    • 22944441604 scopus 로고    scopus 로고
    • Radial to femoral arterial blood pressure differences during liver transplantation
    • 10.1111/j.1365-2044.2005.04257.x, 16029225
    • Arnal D, Garutti I, Perez-Pena J, Olmedilla L, Tzenkov IG. Radial to femoral arterial blood pressure differences during liver transplantation. Anaesthesia 2005, 60:766-771. 10.1111/j.1365-2044.2005.04257.x, 16029225.
    • (2005) Anaesthesia , vol.60 , pp. 766-771
    • Arnal, D.1    Garutti, I.2    Perez-Pena, J.3    Olmedilla, L.4    Tzenkov, I.G.5
  • 14
    • 72149091552 scopus 로고    scopus 로고
    • Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients
    • Hofer CK, Button D, Weibel L, Genoni M, Zollinger A. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients. J Cardiothorac Vasc Anesth 2009,
    • (2009) J Cardiothorac Vasc Anesth
    • Hofer, C.K.1    Button, D.2    Weibel, L.3    Genoni, M.4    Zollinger, A.5
  • 15
    • 77950019418 scopus 로고    scopus 로고
    • Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary catheter thermodilution measurements?
    • Schramm S, Albrecht E, Frascarolo P, Chassot PG, Spahn DR. Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary catheter thermodilution measurements?. J Cardiothorac Vasc Anesth 2009,
    • (2009) J Cardiothorac Vasc Anesth
    • Schramm, S.1    Albrecht, E.2    Frascarolo, P.3    Chassot, P.G.4    Spahn, D.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.