1
-
-
0025361628
-
Non-invasive cardiac output: Simultaneous comparison of two different methods with thermodilution
-
D.H. Wong, K.K. Tremper, and E.A. Stemmer Non-invasive cardiac output: Simultaneous comparison of two different methods with thermodilution Anesthesiology 72 1990 784 792
-
(1990)
Anesthesiology
, vol.72
, pp. 784-792
-
-
Wong, D.H.1
Tremper, K.K.2
Stemmer, E.A.3
-
2
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
L.A.H. Critchley, and J.A.J.H. Critchley A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 1999 85 91
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 85-91
-
-
Critchley, L.A.H.1
Critchley, J.A.J.H.2
-
3
-
-
57349199888
-
Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
-
G. Biancofiore, L.A.H. Critchley, and A. Lee Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery Br J Aneasth 102 2009 47 54
-
(2009)
Br J Aneasth
, vol.102
, pp. 47-54
-
-
Biancofiore, G.1
Critchley, L.A.H.2
Lee, A.3
-
4
-
-
0026782554
-
Accuracy of the BioMED NCCOM3 bioimpedance cardiac output monitor during induced hypotension: An experimental study in dogs
-
J. Tibballs, M. Hochmann, and A. Osborne Accuracy of the BioMED NCCOM3 bioimpedance cardiac output monitor during induced hypotension: An experimental study in dogs Anaesth Intensive Care 20 1992 326 331
-
(1992)
Anaesth Intensive Care
, vol.20
, pp. 326-331
-
-
Tibballs, J.1
Hochmann, M.2
Osborne, A.3
-
6
-
-
0034869820
-
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
-
J.R.C. Jansen, J.J. Schrueder, and J.P. Mulier A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients Br J Anaesth 87 2001 212 222
-
(2001)
Br J Anaesth
, vol.87
, pp. 212-222
-
-
Jansen, J.R.C.1
Schrueder, J.J.2
Mulier, J.P.3
-
7
-
-
67650678367
-
Pulse contour analysis and transesophageal echocardiography: A comparison of measurements of cardiac output during laparoscopic colon surgery
-
M.R. Concha, V.F. Mertz, and L.I. Corinez Pulse contour analysis and transesophageal echocardiography: A comparison of measurements of cardiac output during laparoscopic colon surgery Anesth Analg 109 2009 114 118
-
(2009)
Anesth Analg
, vol.109
, pp. 114-118
-
-
Concha, M.R.1
Mertz, V.F.2
Corinez, L.I.3
-
8
-
-
70350050949
-
Assessment of the clinical utility of an ultrasonic monitor of cardiac output (the USCOM) and agreement with thermodilution measurement
-
M. Boyle, L. Steel, and G.M. Flynn Assessment of the clinical utility of an ultrasonic monitor of cardiac output (the USCOM) and agreement with thermodilution measurement Crit Care Resusc 11 2009 198 203
-
(2009)
Crit Care Resusc
, vol.11
, pp. 198-203
-
-
Boyle, M.1
Steel, L.2
Flynn, G.M.3
-
9
-
-
39749138803
-
Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device
-
J. Mayer, J. Boldt, and M.W. Wolf Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device Anesth Analg 106 2008 867 872
-
(2008)
Anesth Analg
, vol.106
, pp. 867-872
-
-
Mayer, J.1
Boldt, J.2
Wolf, M.W.3
-
10
-
-
0027447134
-
Errors in the measurement of cardiac output by thermodilution
-
T. Nishikawa, and S. Dohi Errors in the measurement of cardiac output by thermodilution Can J Anaesth 40 1993 142 153
-
(1993)
Can J Anaesth
, vol.40
, pp. 142-153
-
-
Nishikawa, T.1
Dohi, S.2
-
11
-
-
34347375489
-
Agreement between methods of measurement with multiple observations per individual
-
J.M. Bland, and D.G. Altman Agreement between methods of measurement with multiple observations per individual J Biopharm Stat 17 2007 571 582
-
(2007)
J Biopharm Stat
, vol.17
, pp. 571-582
-
-
Bland, J.M.1
Altman, D.G.2
-
12
-
-
0032884749
-
Measuring agreement in method comparison studies
-
J.M. Bland, and D.G. Altman Measuring agreement in method comparison studies Stat Methods Med Res 8 1999 135 160
-
(1999)
Stat Methods Med Res
, vol.8
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
13
-
-
48749095774
-
Statistical models for assessing agreement in method comparison studies with replicate measurements
-
B. Carstensen, J. Simpson, and L.C. Gurrin Statistical models for assessing agreement in method comparison studies with replicate measurements Int J Biostat 4 2008
-
(2008)
Int J Biostat
, vol.4
-
-
Carstensen, B.1
Simpson, J.2
Gurrin, L.C.3
-
14
-
-
0022590888
-
Method of assessing the reproducibility of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers
-
J.D. Mackenzie, N.E. Haites, and J.M. Rawles Method of assessing the reproducibility of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers Br J Anaesth 55 1986 14 24
-
(1986)
Br J Anaesth
, vol.55
, pp. 14-24
-
-
MacKenzie, J.D.1
Haites, N.E.2
Rawles, J.M.3
-
15
-
-
0020445597
-
Reliability of the thermodilution method in the determination of cardiac output in clinical practice
-
C.W. Stetz, R.G. Miller, G.E. Kelly, and T.A. Raffin Reliability of the thermodilution method in the determination of cardiac output in clinical practice Am Rev Respir Dis 126 1982 1001 1004
-
(1982)
Am Rev Respir Dis
, vol.126
, pp. 1001-1004
-
-
Stetz, C.W.1
Miller, R.G.2
Kelly, G.E.3
Raffin, T.A.4
-
16
-
-
0015041424
-
A new technique for measurement of cardiac output by thermodilution in man
-
W. Ganz, R. Donoso, and H.S. Marcus A new technique for measurement of cardiac output by thermodilution in man Am J Cardiol 27 1971 392 396
-
(1971)
Am J Cardiol
, vol.27
, pp. 392-396
-
-
Ganz, W.1
Donoso, R.2
Marcus, H.S.3
-
17
-
-
0023894669
-
Comparison of bioimpedance and thermodilution methods for clinical studies
-
F.G. Spinale, H.D. Reines, and F.A. Crawford Comparison of bioimpedance and thermodilution methods for clinical studies Ann Thorac Surg 45 1988 421 425
-
(1988)
Ann Thorac Surg
, vol.45
, pp. 421-425
-
-
Spinale, F.G.1
Reines, H.D.2
Crawford, F.A.3
|