메뉴 건너뛰기




Volumn 224, Issue 12, 2010, Pages 1471-1486

Relative influence of surface topography and surface chemistry on cell response to bone implant materials. Part 1: Physico-chemical effects

Author keywords

bone; coatings; implant; roughness measurement; roughness parameters; surface chemistry; surface topography; surface treatments; XPS

Indexed keywords

BONE IMPLANT MATERIAL; CELL RESPONSE; CELL-MATERIAL INTERACTION; MICRO-SCALES; NANO SCALE; PHYSICO-CHEMICALS; ROUGHNESS AMPLITUDE; ROUGHNESS PARAMETERS; PERFECT CONTROLS;

EID: 79952799931     PISSN: 09544119     EISSN: 20413033     Source Type: Journal    
DOI: 10.1243/09544119JEIM900     Document Type: Conference Paper
Times cited : (83)

References (86)
  • 1
    • 0030034976 scopus 로고    scopus 로고
    • Role of material surfaces in regulating bone and cartilage cell response
    • Boyan B. D., Hummert T. W., Dean D. D., Schwartz Z. Role of material surfaces in regulating bone and cartilage cell response. Biomaterials. 1996 ; 17: 137-146
    • (1996) Biomaterials , vol.17 , pp. 137-146
    • Boyan, B.D.1    Hummert, T.W.2    Dean, D.D.3    Schwartz, Z.4
  • 2
    • 0033083630 scopus 로고    scopus 로고
    • The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo
    • Brunette D. M., Chehroudi B. The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo. J. Biomech. Engng. 1999 ; 121: 49-57
    • (1999) J. Biomech. Engng , vol.121 , pp. 49-57
    • Brunette, D.M.1    Chehroudi, B.2
  • 3
    • 0033961642 scopus 로고    scopus 로고
    • Osteoblast adhesion on biomaterials
    • Anselme K. Osteoblast adhesion on biomaterials. Biomaterials. 2000 ; 21: 667-681
    • (2000) Biomaterials , vol.21 , pp. 667-681
    • Anselme, K.1
  • 5
    • 24944476564 scopus 로고    scopus 로고
    • Topographically induced direct cell mechanotransduction
    • Dalby M. J. Topographically induced direct cell mechanotransduction. Med. Engng Physics. 2005 ; 27: 730-742
    • (2005) Med. Engng Physics , vol.27 , pp. 730-742
    • Dalby, M.J.1
  • 7
    • 0036908789 scopus 로고    scopus 로고
    • Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings
    • Hacking S. A., Tanzer M., Harvey E. J., Krygier J. J., Bobyn J. D. Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings. Clin. Orthop. Related Res. 2002 ; 405: 24-38
    • (2002) Clin. Orthop. Related Res. , vol.405 , pp. 24-38
    • Hacking, S.A.1    Tanzer, M.2    Harvey, E.J.3    Krygier, J.J.4    Bobyn, J.D.5
  • 8
    • 33646491754 scopus 로고    scopus 로고
    • Effect of a gold-palladium coating on the long-term adhesion of human osteoblasts on biocompatible metallic materials
    • Anselme K., Bigerelle M. Effect of a gold-palladium coating on the long-term adhesion of human osteoblasts on biocompatible metallic materials. Surf. Coating Technol. 2006 ; 200: 6325-6330
    • (2006) Surf. Coating Technol. , vol.200 , pp. 6325-6330
    • Anselme, K.1    Bigerelle, M.2
  • 9
    • 33744781338 scopus 로고    scopus 로고
    • Statistical demonstration of the relative effect of surface chemistry and roughness on human osteoblast short-term adhesion
    • Anselme K., Bigerelle M. Statistical demonstration of the relative effect of surface chemistry and roughness on human osteoblast short-term adhesion. J. Mater. Sci.-Mater. Medicine. 2006 ; 17: 471-479
    • (2006) J. Mater. Sci.-Mater. Medicine , vol.17 , pp. 471-479
    • Anselme, K.1    Bigerelle, M.2
  • 10
    • 65549163087 scopus 로고    scopus 로고
    • Chemical and topographical influence of hydroxyapatite and beta-tricalcium phosphate surfaces on human osteoblastic cell behavior
    • dos Santos E. A., Farina M., Soares G. A., Anselme K. Chemical and topographical influence of hydroxyapatite and beta-tricalcium phosphate surfaces on human osteoblastic cell behavior. J. Biomed. Mater. Res. A. 2009 ; 89: 510-520
    • (2009) J. Biomed. Mater. Res. A , vol.89 , pp. 510-520
    • Dos Santos, E.A.1    Farina, M.2    Soares, G.A.3    Anselme, K.4
  • 11
    • 0037024113 scopus 로고    scopus 로고
    • Use of Ti-coated replicas to investigate the effects on fibroblast shape of surfaces with varying roughness and constant chemical composition
    • Wieland M., Chehroudi B., Textor M., Brunette D. M. Use of Ti-coated replicas to investigate the effects on fibroblast shape of surfaces with varying roughness and constant chemical composition. J. Biomed. Mater. Res. 2002 ; 60: 434-444
    • (2002) J. Biomed. Mater. Res. , vol.60 , pp. 434-444
    • Wieland, M.1    Chehroudi, B.2    Textor, M.3    Brunette, D.M.4
  • 13
    • 28444460781 scopus 로고    scopus 로고
    • Topography effects of pure titanium substrates on human osteoblast long-term adhesion
    • Anselme K., Bigerelle M. Topography effects of pure titanium substrates on human osteoblast long-term adhesion. Acta Biomater. 2005 ; 1: 211-222
    • (2005) Acta Biomater. , vol.1 , pp. 211-222
    • Anselme, K.1    Bigerelle, M.2
  • 14
    • 58849088238 scopus 로고    scopus 로고
    • The relevance of topographic measurements on high precision machined surfaces
    • Gautier A., Revel P., Mazeran P. E., Bigerelle M. The relevance of topographic measurements on high precision machined surfaces. Materiaux et Techniques. 2007 ; 95: 37-46
    • (2007) Materiaux et Techniques , vol.95 , pp. 37-46
    • Gautier, A.1    Revel, P.2    Mazeran, P.E.3    Bigerelle, M.4
  • 15
    • 0029409945 scopus 로고
    • Comparison of surface roughness measurements by stylus profiler, AFM and non-contact optical profiler
    • Poon C. Y., Bhushan B. Comparison of surface roughness measurements by stylus profiler, AFM and non-contact optical profiler. Wear. 1995 ; 190: 76-88
    • (1995) Wear , vol.190 , pp. 76-88
    • Poon, C.Y.1    Bhushan, B.2
  • 16
    • 78651559841 scopus 로고    scopus 로고
    • Multi-scale analysis of high precision surfaces by stylus profiler, scanning white-light interferometry and atomic force microscopy
    • Jouini N., Gautier A., Revel P., Mazeran P. E., Bigerelle M. Multi-scale analysis of high precision surfaces by stylus profiler, scanning white-light interferometry and atomic force microscopy. Int. J. Surf. Sci. Engng. 2009 ; 3: 310-327
    • (2009) Int. J. Surf. Sci. Engng , vol.3 , pp. 310-327
    • Jouini, N.1    Gautier, A.2    Revel, P.3    Mazeran, P.E.4    Bigerelle, M.5
  • 18
    • 32044461813 scopus 로고    scopus 로고
    • Design of hysteresis-compensating iterative learning control for piezo-positioners: Application to atomic force microscopes
    • Leang K. K., Devasia S. Design of hysteresis-compensating iterative learning control for piezo-positioners: Application to atomic force microscopes. Mechatronics. 2006 ; 16: 141-158
    • (2006) Mechatronics , vol.16 , pp. 141-158
    • Leang, K.K.1    Devasia, S.2
  • 19
    • 20044394787 scopus 로고    scopus 로고
    • Curvature radius analysis for scanning probe microscopy
    • Mazeran P. E., Odoni L., Loubet J. L. Curvature radius analysis for scanning probe microscopy. Surf. Sci. 2005 ; 585: 25-37
    • (2005) Surf. Sci. , vol.585 , pp. 25-37
    • Mazeran, P.E.1    Odoni, L.2    Loubet, J.L.3
  • 20
    • 0019374463 scopus 로고
    • Use of a profilometer for surface mapping
    • Snaith B., Edmondst M. J., Probert S. D. Use of a profilometer for surface mapping. Precis Eng. 1981 ; 3: 87-90
    • (1981) Precis Eng , vol.3 , pp. 87-90
    • Snaith, B.1    Edmondst, M.J.2    Probert, S.D.3
  • 22
    • 34548494625 scopus 로고    scopus 로고
    • Roughness characteristic length scales of micro-machined surfaces: A multi-scale modelling
    • Bigerelle M., Gautier A., Iost A. Roughness characteristic length scales of micro-machined surfaces: A multi-scale modelling. Sensors Actuators B-Chemistry. 2007 ; 126: 126-137
    • (2007) Sensors Actuators B-Chemistry , vol.126 , pp. 126-137
    • Bigerelle, M.1    Gautier, A.2    Iost, A.3
  • 25
    • 10444263795 scopus 로고    scopus 로고
    • Identification of scratch mechanisms on a retrieved metallic femoral head
    • Najjar D., Bigerelle M., Migaud H., Iost A. Identification of scratch mechanisms on a retrieved metallic femoral head. Wear. 2005 ; 258: 240-250
    • (2005) Wear , vol.258 , pp. 240-250
    • Najjar, D.1    Bigerelle, M.2    Migaud, H.3    Iost, A.4
  • 26
    • 33747426979 scopus 로고    scopus 로고
    • About the relevance of roughness parameters used for characterizing worn femoral heads
    • Najjar D., Bigerelle M., Migaud H., Iost A. About the relevance of roughness parameters used for characterizing worn femoral heads. Tribology Int. 2006 ; 39: 1527-1537
    • (2006) Tribology Int. , vol.39 , pp. 1527-1537
    • Najjar, D.1    Bigerelle, M.2    Migaud, H.3    Iost, A.4
  • 27
    • 34249915078 scopus 로고    scopus 로고
    • A numerical method to calculate the Abbott parameters: A wear application
    • Bigerelle M., Iost A. A numerical method to calculate the Abbott parameters: A wear application. Tribology Int. 2007 ; 40: 1319-1334
    • (2007) Tribology Int. , vol.40 , pp. 1319-1334
    • Bigerelle, M.1    Iost, A.2
  • 28
    • 0001480635 scopus 로고    scopus 로고
    • Calcul de la dimension fractale d'un profil par la méthode des autocorrélations moyennées normées A.M.N
    • Bigerelle M., Iost A. Calcul de la dimension fractale d'un profil par la méthode des autocorrélations moyennées normées A.M.N. CR Acad. Sci. Paris. 1996 ; 323: 669-675
    • (1996) CR Acad. Sci. Paris , vol.323 , pp. 669-675
    • Bigerelle, M.1    Iost, A.2
  • 29
    • 34547666988 scopus 로고    scopus 로고
    • A multi-scale approach of roughness measurements: Evaluation of the relevant scale
    • Van Gorp A., Bigerelle M., Grellier A., Iost A., Najjar D. A multi-scale approach of roughness measurements: Evaluation of the relevant scale. Mater. Sci. Engng C-Bio S. 2007 ; 27: 1434-1438
    • (2007) Mater. Sci. Engng C-Bio S , vol.27 , pp. 1434-1438
    • Van Gorp, A.1    Bigerelle, M.2    Grellier, A.3    Iost, A.4    Najjar, D.5
  • 33
    • 84864027028 scopus 로고    scopus 로고
    • American Society for Mechanical Engineers. (ASME, New York)
    • American Society for Mechanical Engineers. ASME Y14.36M: Surface texture symbols, 1996 (ASME, New York).
    • (1996) 36M: Surface texture symbols
  • 35
    • 34249915078 scopus 로고    scopus 로고
    • A numerical method to calculate the Abbott parameters: A wear application
    • Bigerelle M., Iost A. A numerical method to calculate the Abbott parameters: A wear application. Tribology Int. 2007 ; 40: 1319-1334
    • (2007) Tribology Int. , vol.40 , pp. 1319-1334
    • Bigerelle, M.1    Iost, A.2
  • 36
    • 10444275603 scopus 로고    scopus 로고
    • Multiscale functional analysis of wear-A fractal model of the grinding process
    • Bigerelle M., Najjar D., Iost A. Multiscale functional analysis of wear-A fractal model of the grinding process. Wear. 2005 ; 258: 232-239
    • (2005) Wear , vol.258 , pp. 232-239
    • Bigerelle, M.1    Najjar, D.2    Iost, A.3
  • 38
    • 51349148837 scopus 로고    scopus 로고
    • Multiscale roughness analysis in injection-molding process
    • Bigerelle M., Van Gorp A., Lost A. Multiscale roughness analysis in injection-molding process. Polymer Engng Sci. 2008 ; 48: 1725-1736
    • (2008) Polymer Engng Sci. , vol.48 , pp. 1725-1736
    • Bigerelle, M.1    Van Gorp, A.2    Lost, A.3
  • 39
    • 77649295238 scopus 로고    scopus 로고
    • Effects of working parameters on the surface roughness in belt grinding process: The size-scale estimation influence
    • Van Gorp A., Bigerelle M., El Mansori M., Ghidossi P., Iost A. Effects of working parameters on the surface roughness in belt grinding process: The size-scale estimation influence. Int. J. Mater. Prod. Technol. 2010 ; 38: 16-34
    • (2010) Int. J. Mater. Prod. Technol. , vol.38 , pp. 16-34
    • Van Gorp, A.1    Bigerelle, M.2    El Mansori, M.3    Ghidossi, P.4    Iost, A.5
  • 40
    • 0038268044 scopus 로고    scopus 로고
    • Relevance of roughness parameters for describing and modelling machined surfaces
    • Bigerelle M., Najjar D., Iost A. Relevance of roughness parameters for describing and modelling machined surfaces. J. Mater. Sci. 2003 ; 38: 2525-2536
    • (2003) J. Mater. Sci. , vol.38 , pp. 2525-2536
    • Bigerelle, M.1    Najjar, D.2    Iost, A.3
  • 41
    • 0038207795 scopus 로고    scopus 로고
    • The computer-based bootstrap method as a tool to select a relevant surface roughness parameter
    • Najjar D., Bigerelle M., Iost A. The computer-based bootstrap method as a tool to select a relevant surface roughness parameter. Wear. 2003 ; 254: 450-460
    • (2003) Wear , vol.254 , pp. 450-460
    • Najjar, D.1    Bigerelle, M.2    Iost, A.3
  • 42
    • 33646407579 scopus 로고    scopus 로고
    • Influence of the morphological texture on the low wear damage of paint coated sheets
    • Hennebelle F., Najjar D., Bigerelle M., Iost A. Influence of the morphological texture on the low wear damage of paint coated sheets. Prog. Org. Coatings. 2006 ; 56: 81-89
    • (2006) Prog. Org. Coatings , vol.56 , pp. 81-89
    • Hennebelle, F.1    Najjar, D.2    Bigerelle, M.3    Iost, A.4
  • 43
    • 33645838421 scopus 로고    scopus 로고
    • Contribution of statistical methods to the study of worn paint coatings surface topography
    • Najjar D., Bigerelle M., Hennebelle F., Iost A. Contribution of statistical methods to the study of worn paint coatings surface topography. Surf. Coating Technol. 2006 ; 200: 6088-6100
    • (2006) Surf. Coating Technol. , vol.200 , pp. 6088-6100
    • Najjar, D.1    Bigerelle, M.2    Hennebelle, F.3    Iost, A.4
  • 44
    • 44649127494 scopus 로고    scopus 로고
    • Multiscale analysis of abrasion damage on stainless steel
    • Giljean S., Najjar D., Bigerelle M., Iost A. Multiscale analysis of abrasion damage on stainless steel. Surf. Engng. 2008 ; 24: 8-17
    • (2008) Surf. Engng , vol.24 , pp. 8-17
    • Giljean, S.1    Najjar, D.2    Bigerelle, M.3    Iost, A.4
  • 45
    • 43449090093 scopus 로고    scopus 로고
    • Chemical and biological functionalization of titanium for dental implants
    • Schliephake H., Scharnweber D. Chemical and biological functionalization of titanium for dental implants. J. Mater. Chemistry. 2008 ; 18: 2404-2414
    • (2008) J. Mater. Chemistry , vol.18 , pp. 2404-2414
    • Schliephake, H.1    Scharnweber, D.2
  • 46
    • 0032745323 scopus 로고    scopus 로고
    • Understanding and controlling the bone-implant interface
    • Puleo D. A., Nanci A. Understanding and controlling the bone-implant interface. Biomaterials. 1999 ; 20: 2311-2321
    • (1999) Biomaterials , vol.20 , pp. 2311-2321
    • Puleo, D.A.1    Nanci, A.2
  • 47
    • 34248356846 scopus 로고    scopus 로고
    • Surface treatments of titanium dental implants for rapid osseointegration
    • Le Guehennec L., Soueidan A., Layrolle P., Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent. Mater. 2007 ; 23: 844-854
    • (2007) Dent. Mater. , vol.23 , pp. 844-854
    • Le Guehennec, L.1    Soueidan, A.2    Layrolle, P.3    Amouriq, Y.4
  • 49
    • 0031127164 scopus 로고    scopus 로고
    • Bioactivity of titanium treated with hydrogen peroxide solutions containing metal chlorides
    • Ohtsuki C., Iida H., Hayakawa S., Osaka A. Bioactivity of titanium treated with hydrogen peroxide solutions containing metal chlorides. J. Biomed. Mater. Res. 1997 ; 35: 39-47
    • (1997) J. Biomed. Mater. Res. , vol.35 , pp. 39-47
    • Ohtsuki, C.1    Iida, H.2    Hayakawa, S.3    Osaka, A.4
  • 50
    • 4844220511 scopus 로고    scopus 로고
    • Surface treatments and roughness properties of Ti-based biomaterials
    • Bagno A., Di Bello C. Surface treatments and roughness properties of Ti-based biomaterials. J Mater Sci-Mater Med. 2004 ; 15: 935-949
    • (2004) J Mater Sci-Mater Med , vol.15 , pp. 935-949
    • Bagno, A.1    Di Bello, C.2
  • 51
    • 33645096659 scopus 로고    scopus 로고
    • Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces
    • Rupp F., Scheideler L., Olshanska N., de Wild M., Wieland M., Geis-Gerstorfer J. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces. J. Biomed. Mater. Res. A. 2006 ; 76: 323-334
    • (2006) J. Biomed. Mater. Res. A , vol.76 , pp. 323-334
    • Rupp, F.1    Scheideler, L.2    Olshanska, N.3    De Wild, M.4    Wieland, M.5    Geis-Gerstorfer, J.6
  • 52
    • 0034960852 scopus 로고    scopus 로고
    • The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes
    • Sul Y. T., Johansson C. B., Jeong Y., Albrektsson T. The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes. Med. Engng Physics. 2001 ; 23: 329-346
    • (2001) Med. Engng Physics , vol.23 , pp. 329-346
    • Sul, Y.T.1    Johansson, C.B.2    Jeong, Y.3    Albrektsson, T.4
  • 53
    • 0030232323 scopus 로고    scopus 로고
    • Surface spectroscopic characterization of titanium implant materials
    • Lausmaa J. Surface spectroscopic characterization of titanium implant materials. J. Electron Spectroscopy. 1996 ; 81: 343-361
    • (1996) J. Electron Spectroscopy , vol.81 , pp. 343-361
    • Lausmaa, J.1
  • 54
  • 55
    • 0036533256 scopus 로고    scopus 로고
    • Improvement in the morphology of surfaces for cell adhesion: A new process to double human osteoblast adhesion on Ti-based substrates
    • Bigerelle M., Anselme K., Noël B., Ruderman I., Hardouin P., Iost A. Improvement in the morphology of surfaces for cell adhesion: A new process to double human osteoblast adhesion on Ti-based substrates. Biomaterials. 2002 ; 23: 1563-1577
    • (2002) Biomaterials , vol.23 , pp. 1563-1577
    • Bigerelle, M.1    Anselme, K.2    Noël, B.3    Ruderman, I.4    Hardouin, P.5    Iost, A.6
  • 57
    • 3242661774 scopus 로고    scopus 로고
    • Quantitative methods for analysis of integrin binding and focal adhesion formation on biomaterial surfaces
    • Keselowsky B. G., Garcia A. J. Quantitative methods for analysis of integrin binding and focal adhesion formation on biomaterial surfaces. Biomaterials. 2005 ; 26: 413-418
    • (2005) Biomaterials , vol.26 , pp. 413-418
    • Keselowsky, B.G.1    Garcia, A.J.2
  • 58
    • 0034579054 scopus 로고    scopus 로고
    • The effect of peptide surface density on mineralization of a matrix deposited by osteogenic cells
    • Rezania A., Healy K. E. The effect of peptide surface density on mineralization of a matrix deposited by osteogenic cells. J. Biomed. Mater. Res. 2000 ; 52: 595-600
    • (2000) J. Biomed. Mater. Res. , vol.52 , pp. 595-600
    • Rezania, A.1    Healy, K.E.2
  • 59
    • 0036205115 scopus 로고    scopus 로고
    • A technique to immobilize bioactive proteins, including bone morphogenetic protein-4 (BMP-4), on titanium alloy
    • Puleo D. A., Kissling R. A., Sheu M. S. A technique to immobilize bioactive proteins, including bone morphogenetic protein-4 (BMP-4), on titanium alloy. Biomaterials. 2002 ; 23: 2079-2087
    • (2002) Biomaterials , vol.23 , pp. 2079-2087
    • Puleo, D.A.1    Kissling, R.A.2    Sheu, M.S.3
  • 60
    • 0142186177 scopus 로고    scopus 로고
    • Characterization and protein-adsorption behavior of deposited organic thin film onto titanium by plasma polymerization with hexamethyldisiloxane
    • Hayakawa T., Yoshinari M., Nemoto K. Characterization and protein-adsorption behavior of deposited organic thin film onto titanium by plasma polymerization with hexamethyldisiloxane. Biomaterials. 2004 ; 25: 119-127
    • (2004) Biomaterials , vol.25 , pp. 119-127
    • Hayakawa, T.1    Yoshinari, M.2    Nemoto, K.3
  • 61
    • 67651089544 scopus 로고    scopus 로고
    • Opposite responses of cells and bacteria to micro/nanopatterned surfaces prepared by pulsed plasma polymerization and UV-irradiation
    • Ploux L., Anselme K., Dirani A., Ponche A., Soppera O., Roucoules V. Opposite responses of cells and bacteria to micro/nanopatterned surfaces prepared by pulsed plasma polymerization and UV-irradiation. Langmuir. 2009 ; 25: 8161-8169
    • (2009) Langmuir , vol.25 , pp. 8161-8169
    • Ploux, L.1    Anselme, K.2    Dirani, A.3    Ponche, A.4    Soppera, O.5    Roucoules, V.6
  • 62
    • 0042388626 scopus 로고    scopus 로고
    • Surface engineering of titanium by collagen immobilization. Surface characterization and in vitro and in vivo studies
    • Morra M., Cassinelli C., Cascardo G., Cahalan P., Cahalan L., Fini M., Giardino R. Surface engineering of titanium by collagen immobilization. Surface characterization and in vitro and in vivo studies. Biomaterials. 2003 ; 24: 4639-4654
    • (2003) Biomaterials , vol.24 , pp. 4639-4654
    • Morra, M.1    Cassinelli, C.2    Cascardo, G.3    Cahalan, P.4    Cahalan, L.5    Fini, M.6    Giardino, R.7
  • 63
    • 67349085757 scopus 로고    scopus 로고
    • Applications of plasma-based technology to microelectronics and biomedical engineering
    • Chu P. K. Applications of plasma-based technology to microelectronics and biomedical engineering. Surf. Coating Technol. 2009 ; 203: 2793-2798
    • (2009) Surf. Coating Technol. , vol.203 , pp. 2793-2798
    • Chu, P.K.1
  • 64
    • 0033993822 scopus 로고    scopus 로고
    • Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings
    • Zheng X. B., Huang M. H., Ding C. X. Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings. Biomaterials. 2000 ; 21: 841-849
    • (2000) Biomaterials , vol.21 , pp. 841-849
    • Zheng, X.B.1    Huang, M.H.2    Ding, C.X.3
  • 65
    • 0142033801 scopus 로고    scopus 로고
    • Bond strength, compositional, and structural properties of hydroxyapatite coating on Ti, ZrO2-coated Ti, and TPS-coated Ti substrate
    • Yang Y. Z., Ong J. L. Bond strength, compositional, and structural properties of hydroxyapatite coating on Ti, ZrO2-coated Ti, and TPS-coated Ti substrate. J. Biomed. Mater. Res. A. 2003 ; 64: 509-516
    • (2003) J. Biomed. Mater. Res. A , vol.64 , pp. 509-516
    • Yang, Y.Z.1    Ong, J.L.2
  • 68
    • 0242606916 scopus 로고    scopus 로고
    • Preparation of bioactive titanium metal via anodic oxidation treatment
    • Yang B. C., Uchida M., Kim H. M., Zhang X. D., Kokubo T. Preparation of bioactive titanium metal via anodic oxidation treatment. Biomaterials. 2004 ; 25: 1003-1010
    • (2004) Biomaterials , vol.25 , pp. 1003-1010
    • Yang, B.C.1    Uchida, M.2    Kim, H.M.3    Zhang, X.D.4    Kokubo, T.5
  • 69
    • 0041887305 scopus 로고    scopus 로고
    • Apatite deposition on thermally and anodically oxidized titanium surfaces in a simulated body fluid
    • Wang X. X., Yan W., Hayakawa S., Tsuru K., Osaka A. Apatite deposition on thermally and anodically oxidized titanium surfaces in a simulated body fluid. Biomaterials. 2003 ; 24: 4631-4637
    • (2003) Biomaterials , vol.24 , pp. 4631-4637
    • Wang, X.X.1    Yan, W.2    Hayakawa, S.3    Tsuru, K.4    Osaka, A.5
  • 70
    • 33745037931 scopus 로고    scopus 로고
    • Surface modifications of bone implants through wet chemistry
    • Duan K., Wang R. Z. Surface modifications of bone implants through wet chemistry. J. Mater. Chemistry. 2006 ; 16: 2309-2321
    • (2006) J. Mater. Chemistry , vol.16 , pp. 2309-2321
    • Duan, K.1    Wang, R.Z.2
  • 71
    • 0000776920 scopus 로고    scopus 로고
    • Oxides formed on titanium by polishing, etching, anodizing, or thermal oxidizing
    • Birch J. R., Burleigh T. D. Oxides formed on titanium by polishing, etching, anodizing, or thermal oxidizing. Corrosion. 2000 ; 56: 1233-1241
    • (2000) Corrosion , vol.56 , pp. 1233-1241
    • Birch, J.R.1    Burleigh, T.D.2
  • 72
    • 4644336075 scopus 로고    scopus 로고
    • XPS characterization of anodic titanium oxide films grown in phosphate buffer solutions
    • Marino C. E. B., Nascente P. A. P., Biaggio S. R., Rocha R. C., Bocchi N. XPS characterization of anodic titanium oxide films grown in phosphate buffer solutions. Thin Solid Films. 2004 ; 468: 109-112
    • (2004) Thin Solid Films , vol.468 , pp. 109-112
    • Marino, C.E.B.1    Nascente, P.A.P.2    Biaggio, S.R.3    Rocha, R.C.4    Bocchi, N.5
  • 74
    • 0036131596 scopus 로고    scopus 로고
    • Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition
    • Sul Y.-T., Johansson C. B., Petronis S., Krozer A., Jeong Y., Wennerberg A., Albrektsson T. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials. 2002 ; 23: 491-501
    • (2002) Biomaterials , vol.23 , pp. 491-501
    • Sul, Y.-T.1    Johansson, C.B.2    Petronis, S.3    Krozer, A.4    Jeong, Y.5    Wennerberg, A.6    Albrektsson, T.7
  • 75
    • 22144435925 scopus 로고    scopus 로고
    • Effect of several sterilisation techniques on homogeneous self assembled monolayers
    • Fleith S., Ponche A., Bareille R., Amedee J., Nardin M. Effect of several sterilisation techniques on homogeneous self assembled monolayers. Colloid Surf. B. 2005 ; 44: 15-24
    • (2005) Colloid Surf. B , vol.44 , pp. 15-24
    • Fleith, S.1    Ponche, A.2    Bareille, R.3    Amedee, J.4    Nardin, M.5
  • 77
    • 0038118491 scopus 로고    scopus 로고
    • Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour
    • Ponsonnet L., Reybier K., Jaffrezic N., Comte V., Lagneau C., Lissac M., Martelet C. Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour. Mater. Sci. Engng C. 2003 ; 23: 551-560
    • (2003) Mater. Sci. Engng C , vol.23 , pp. 551-560
    • Ponsonnet, L.1    Reybier, K.2    Jaffrezic, N.3    Comte, V.4    Lagneau, C.5    Lissac, M.6    Martelet, C.7
  • 78
    • 0028630401 scopus 로고
    • Surface-energy characterization of unalloyed titanium implants
    • Kilpadi D. V., Lemons J. E. Surface-energy characterization of unalloyed titanium implants. J. Biomed. Mater. Res. 1994 ; 28: 1419-1425
    • (1994) J. Biomed. Mater. Res. , vol.28 , pp. 1419-1425
    • Kilpadi, D.V.1    Lemons, J.E.2
  • 80
    • 38049083862 scopus 로고    scopus 로고
    • Spectroscopic analysis of titanium surface functional groups under various surface modification and their behaviors in vitro and in vivo
    • Lu X., Wang Y., Yang X., Zhang Q., Zhao Z., Weng L. T., Leng Y. Spectroscopic analysis of titanium surface functional groups under various surface modification and their behaviors in vitro and in vivo. J. Biomed. Mater. Res. 2008 ; 84: 523-534
    • (2008) J. Biomed. Mater. Res. , vol.84 , pp. 523-534
    • Lu, X.1    Wang, Y.2    Yang, X.3    Zhang, Q.4    Zhao, Z.5    Weng, L.T.6    Leng, Y.7
  • 81
    • 67651166609 scopus 로고    scopus 로고
    • Semi-conducting properties of titanium dioxide surfaces on titanium implants
    • Petersson I. U., Loberg J. E. L., Fredriksson A. S., Ahlberg E. K. Semi-conducting properties of titanium dioxide surfaces on titanium implants. Biomaterials. 2009 ; 30: 4471-4479
    • (2009) Biomaterials , vol.30 , pp. 4471-4479
    • Petersson, I.U.1    Loberg, J.E.L.2    Fredriksson, A.S.3    Ahlberg, E.K.4
  • 82
    • 0035501262 scopus 로고    scopus 로고
    • Visualisation of human plasma fibrinogen adsorbed on titanium implant surfaces with different roughness
    • Cacciafesta P., Hallam K. R., Watkinson A. C., Allen G. C., Miles M. J., Jandt K. D. Visualisation of human plasma fibrinogen adsorbed on titanium implant surfaces with different roughness. Surf. Sci. 2001 ; 491: 405-420
    • (2001) Surf. Sci. , vol.491 , pp. 405-420
    • Cacciafesta, P.1    Hallam, K.R.2    Watkinson, A.C.3    Allen, G.C.4    Miles, M.J.5    Jandt, K.D.6
  • 83
    • 67650497946 scopus 로고    scopus 로고
    • Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina-blasted/acid-etched Ti-6Al-4V implant surfaces
    • Coelho P. G., Lemons J. E. Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina-blasted/acid- etched Ti-6Al-4V implant surfaces. J. Biomed. Mater. Res. A. 2009 ; 90A: 351-361
    • (2009) J. Biomed. Mater. Res. A , vol.90 , pp. 351-361
    • Coelho, P.G.1    Lemons, J.E.2
  • 84
  • 86
    • 0031211066 scopus 로고    scopus 로고
    • Surface roughness effects in quantitative XPS: Magic angle for determining overlayer thickness
    • Gunter P. L. J., Gijzeman O. L. J., Niemantsverdriet J. W. Surface roughness effects in quantitative XPS: Magic angle for determining overlayer thickness. Appl. Surf. Sci. 1997 ; 115: 342-346
    • (1997) Appl. Surf. Sci. , vol.115 , pp. 342-346
    • Gunter, P.L.J.1    Gijzeman, O.L.J.2    Niemantsverdriet, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.