메뉴 건너뛰기




Volumn 25, Issue 5, 2010, Pages 947-952

Bone loading caused by different types of misfits of implant-supported fixed dental prostheses: A three-dimensional finite element analysis based on experimental Results

Author keywords

Bone loading; Finite element analysis; Implant supported restoration; Misfit; Passive fit

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; BIOMECHANICS; COMPUTER SIMULATION; DENTAL CARE; DENTURE; FINITE ELEMENT ANALYSIS; HUMAN; JAW; METHODOLOGY; PHYSIOLOGY; PROSTHESIS; THREE DIMENSIONAL IMAGING; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 79952045426     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (48)

References (25)
  • 1
    • 0033088969 scopus 로고    scopus 로고
    • Strategies to achieve fit in implant prosthodontics: A review of the literature
    • Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics: A review of the literature. Int J Prosthodont 1999; 12: 167-178.
    • (1999) Int J Prosthodont , vol.12 , pp. 167-178
    • Wee, A.G.1    Aquilino, S.A.2    Schneider, R.L.3
  • 2
    • 0029185973 scopus 로고
    • The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?
    • Tan KB. The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?. Ann Acad Med Singapore 1995; 24: 138-157.
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 138-157
    • Tan, K.B.1
  • 4
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics: Current status
    • Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: Current status. Implant Dent 2001; 10: 85-92.
    • (2001) Implant Dent , vol.10 , pp. 85-92
    • Sahin, S.1    Cehreli, M.C.2
  • 5
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998; 79: 74-78.
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, T.D.1
  • 6
    • 0032018774 scopus 로고    scopus 로고
    • Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants
    • Hellden LB, Derand T. Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants. Int J Oral Maxillofac Implants 1998; 13: 190-196.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 190-196
    • Hellden, L.B.1    Derand, T.2
  • 8
    • 33644854187 scopus 로고    scopus 로고
    • Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis
    • Natali AN, Pavan PG, Ruggero AL. Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis. Dent Mater 2006; 22: 388-395.
    • (2006) Dent Mater , vol.22 , pp. 388-395
    • Natali, A.N.1    Pavan, P.G.2    Ruggero, A.L.3
  • 9
    • 0030277405 scopus 로고    scopus 로고
    • The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    • Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996; 76: 500-509.
    • (1996) J Prosthet Dent , vol.76 , pp. 500-509
    • Carr, A.B.1    Gerard, D.A.2    Larsen, P.E.3
  • 10
    • 0032602123 scopus 로고    scopus 로고
    • Cemented versus screw-retained implant prostheses: Which is better? [current issues forum]
    • Chee W, Felton DA, Johnson PF, Sullivan DY. Cemented versus screw-retained implant prostheses: Which is better? [current issues forum]. Int J Oral Maxillofac Implants 1999; 14: 137-141.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 137-141
    • Chee, W.1    Felton, D.A.2    Johnson, P.F.3    Sullivan, D.Y.4
  • 11
    • 0142024931 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: A critical review
    • Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: A critical review. Int J Oral Maxillofac Implants 2003; 18: 719-728.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 719-728
    • Michalakis, K.X.1    Hirayama, H.2    Garefis, P.D.3
  • 12
    • 0032603876 scopus 로고    scopus 로고
    • New techniques in spark erosion: The solution to an accurately fitting screw-retained implant restoration
    • Rübeling G. New techniques in spark erosion: The solution to an accurately fitting screw-retained implant restoration. Quintessence Int 1999; 30: 38-48.
    • (1999) Quintessence Int , vol.30 , pp. 38-48
    • Rübeling, G.1
  • 14
    • 2942546370 scopus 로고    scopus 로고
    • A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding
    • Longoni S, Sartori M, Davide R. A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding. J Prosthet Dent 2004; 91: 595-598.
    • (2004) J Prosthet Dent , vol.91 , pp. 595-598
    • Longoni, S.1    Sartori, M.2    Davide, R.3
  • 16
    • 0030226140 scopus 로고    scopus 로고
    • Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996; 5: 193-200.
    • (1996) J Prosthodont , vol.5 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 17
    • 44349111750 scopus 로고    scopus 로고
    • Prosthetic considerations
    • Mericske-Stern R. Prosthetic considerations. Aust Dent J 2008; 53(suppl 1): 49-59.
    • (2008) Aust Dent J , vol.53 , pp. 49-59
    • Mericske-Stern, R.1
  • 18
    • 34250163479 scopus 로고    scopus 로고
    • Evaluation of a new method to achieve optimal passivity of implant-supported superstructures
    • Goossens IC, Herbst D. Evaluation of a new method to achieve optimal passivity of implant-supported superstructures. SADJ 2003; 58: 279-285.
    • (2003) SADJ , vol.58 , pp. 279-285
    • Goossens, I.C.1    Herbst, D.2
  • 20
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001; 85: 585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3
  • 22
    • 58449083652 scopus 로고    scopus 로고
    • Finite element analysis of stress in bone adjacent to dental implants
    • Rubo JH, Souza EA. Finite element analysis of stress in bone adjacent to dental implants. J Oral Implantol 2008; 34: 248-255.
    • (2008) J Oral Implantol , vol.34 , pp. 248-255
    • Rubo, J.H.1    Souza, E.A.2
  • 23
    • 0036514370 scopus 로고    scopus 로고
    • Finite element analysis on dental implant-supported prostheses without passive fit
    • Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 2002; 11: 30-40.
    • (2002) J Prosthodont , vol.11 , pp. 30-40
    • Kunavisarut, C.1    Lang, L.A.2    Stoner, B.R.3    Felton, D.A.4
  • 24
    • 33750551961 scopus 로고    scopus 로고
    • Fixation of 5-unit implant-supported fixed partial dentures and resulting bone loading: A finite element assessment based on in vivo strain measurements
    • Karl M, Winter W, Taylor TD, Heckmann SM. Fixation of 5-unit implant-supported fixed partial dentures and resulting bone loading: A finite element assessment based on in vivo strain measurements. Int J Oral Maxillofac Implants 2006; 21: 756-762.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 756-762
    • Karl, M.1    Winter, W.2    Taylor, T.D.3    Heckmann, S.M.4
  • 25
    • 33646509625 scopus 로고    scopus 로고
    • Loading of bone surrounding implants through three-unit fixed partial denture fixation: A finite-element analysis based on in vitro and in vivo strain measurements
    • Heckmann SM, Karl M, Wichmann MG, Winter W, Graef F, Taylor TD. Loading of bone surrounding implants through three-unit fixed partial denture fixation: A finite-element analysis based on in vitro and in vivo strain measurements. Clin Oral Implants Res 2006; 17: 345-350.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 345-350
    • Heckmann, S.M.1    Karl, M.2    Wichmann, M.G.3    Winter, W.4    Graef, F.5    Taylor, T.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.