메뉴 건너뛰기




Volumn 85, Issue 6, 2001, Pages 585-598

Application of finite element analysis in implant dentistry: A review of the literature

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY;

EID: 0035377329     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2001.115251     Document Type: Review
Times cited : (797)

References (104)
  • 2
    • 0020933362 scopus 로고
    • Stress analysis of single-tooth implants. I. Effect of elastic parameters and geometry of implant
    • Atmaram GH, Mohammed H. Stress analysis of single-tooth implants. I. Effect of elastic parameters and geometry of implant. Implantologist 1983-84;3:24-9.
    • (1983) Implantologist , vol.3 , pp. 24-29
    • Atmaram, G.H.1    Mohammed, H.2
  • 3
    • 0020898298 scopus 로고
    • Stress analysis of single-tooth implants. II. Effect of implant root-length variation and pseudo periodontal ligament incorporation
    • Atmaram GH, Mohammed H. Stress analysis of single-tooth implants. II. Effect of implant root-length variation and pseudo periodontal ligament incorporation. Implantologist 1983-84;3:58-62.
    • (1983) Implantologist , vol.3 , pp. 58-62
    • Atmaram, G.H.1    Mohammed, H.2
  • 5
    • 0020711801 scopus 로고
    • Three-dimensional stress distribution around a dental implant at different stages of interface development
    • Borchers L, Reichart P. Three-dimensional stress distribution around a dental implant at different stages of interface development. J Dent Res 1983;62:155-9.
    • (1983) J Dent Res , vol.62 , pp. 155-159
    • Borchers, L.1    Reichart, P.2
  • 6
    • 0020020445 scopus 로고
    • A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant
    • Cook SD, Weinstein AM, Klawitter JJ. A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant. J Dent Res 1982;61:25-9.
    • (1982) J Dent Res , vol.61 , pp. 25-29
    • Cook, S.D.1    Weinstein, A.M.2    Klawitter, J.J.3
  • 7
    • 0023460248 scopus 로고
    • Finite element analysis of partially edentulous mandible rehabilitated with an osteointegrated cylindrical implant
    • Meroueh KA, Watanabe F, Mentag PJ. Finite element analysis of partially edentulous mandible rehabilitated with an osteointegrated cylindrical implant. J Oral Implantol 1987;13:215-38.
    • (1987) J Oral Implantol , vol.13 , pp. 215-238
    • Meroueh, K.A.1    Watanabe, F.2    Mentag, P.J.3
  • 9
    • 0029678751 scopus 로고    scopus 로고
    • A comparison of stress and strain distribution characteristics of two different rigid implant designs for distal-extension fixed prostheses
    • Akpinar I, Demirel F, Parnas L, Sahin S. A comparison of stress and strain distribution characteristics of two different rigid implant designs for distal-extension fixed prostheses. Quintessence Int 1996;27:11-7.
    • (1996) Quintessence Int , vol.27 , pp. 11-17
    • Akpinar, I.1    Demirel, F.2    Parnas, L.3    Sahin, S.4
  • 10
    • 0030893518 scopus 로고    scopus 로고
    • Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis
    • Korioth TW, Versluis A. Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis. Crit Rev Oral Biol Med 1997;8:90-104.
    • (1997) Crit Rev Oral Biol Med , vol.8 , pp. 90-104
    • Korioth, T.W.1    Versluis, A.2
  • 12
    • 0025441725 scopus 로고
    • Finite element analysis of six endosseous implants
    • Rieger MR, Mayberry M, Brose MO. Finite element analysis of six endosseous implants. J Prosthet Dent 1990;63:671-6.
    • (1990) J Prosthet Dent , vol.63 , pp. 671-676
    • Rieger, M.R.1    Mayberry, M.2    Brose, M.O.3
  • 13
    • 0025407906 scopus 로고
    • Finite element survey of eleven endosseous implants
    • Rieger MR, Adams WK, Kinzel GL. Finite element survey of eleven endosseous implants. J Prosthet Dent 1990;63:457-65.
    • (1990) J Prosthet Dent , vol.63 , pp. 457-465
    • Rieger, M.R.1    Adams, W.K.2    Kinzel, G.L.3
  • 15
    • 0030621894 scopus 로고    scopus 로고
    • Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis
    • Sertgöz A. Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis. Int J Prosthodont 1997;10:19-27.
    • (1997) Int J Prosthodont , vol.10 , pp. 19-27
    • Sertgöz, A.1
  • 16
    • 0025495260 scopus 로고
    • Automated three-dimensional finite element modeling of bone: A new method
    • Keyak JH, Meagher JM, Skinner HB, Mote CD. Automated three-dimensional finite element modeling of bone: a new method. J Biomed Eng 1990;12:389-97.
    • (1990) J Biomed Eng , vol.12 , pp. 389-397
    • Keyak, J.H.1    Meagher, J.M.2    Skinner, H.B.3    Mote, C.D.4
  • 17
    • 0040569956 scopus 로고
    • Interactive modeling environment for craniofacial reconstruction. Visual data exploration and analysis
    • Cahoon P, Hannam AG. Interactive modeling environment for craniofacial reconstruction. Visual data exploration and analysis. SPIE Proc 1994;2178:206-15.
    • (1994) SPIE Proc , vol.2178 , pp. 206-215
    • Cahoon, P.1    Hannam, A.G.2
  • 18
    • 0019496440 scopus 로고
    • Determination of stress patterns in root-filled teeth incorporating various dowel designs
    • Davy DT, Dilley GL, Krejci RF. Determination of stress patterns in root-filled teeth incorporating various dowel designs. J Dent Res 1981;60:1303-10.
    • (1981) J Dent Res , vol.60 , pp. 1303-1310
    • Davy, D.T.1    Dilley, G.L.2    Krejci, R.F.3
  • 19
    • 0018534424 scopus 로고
    • Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments
    • Wright KW, Yettram AL. Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments. J Prosthet Dent 1979;42:411-6.
    • (1979) J Prosthet Dent , vol.42 , pp. 411-416
    • Wright, K.W.1    Yettram, A.L.2
  • 20
    • 0016651274 scopus 로고
    • Effects of cement bases on the stresses in amalgam restorations
    • Farah JW, Hood JA, Craig RG. Effects of cement bases on the stresses in amalgam restorations. J Dent Res 1975;54:10-5.
    • (1975) J Dent Res , vol.54 , pp. 10-15
    • Farah, J.W.1    Hood, J.A.2    Craig, R.G.3
  • 21
    • 0024815560 scopus 로고
    • Finite element analysis of three- and four-unit bridges
    • Farah JW, Craig RG, Meroueh KA. Finite element analysis of three- and four-unit bridges. J Oral Rehabil 1989;16:603-11.
    • (1989) J Oral Rehabil , vol.16 , pp. 603-611
    • Farah, J.W.1    Craig, R.G.2    Meroueh, K.A.3
  • 22
    • 0021260475 scopus 로고
    • Periodontal ligament stresses in the initiation of occlusal traumatism
    • Reinhardt RA, Pao YC, Krejci RF. Periodontal ligament stresses in the initiation of occlusal traumatism. J Periodontal Res 1984;19:238-46.
    • (1984) J Periodontal Res , vol.19 , pp. 238-246
    • Reinhardt, R.A.1    Pao, Y.C.2    Krejci, R.F.3
  • 23
    • 0018993043 scopus 로고
    • Stress analysis of mandibular partial dentures with bounded and free-end saddles
    • MacGregor AR, Miller TP, Farah JW. Stress analysis of mandibular partial dentures with bounded and free-end saddles. J Dent 1980;8:27-34.
    • (1980) J Dent , vol.8 , pp. 27-34
    • MacGregor, A.R.1    Miller, T.P.2    Farah, J.W.3
  • 24
    • 0019452267 scopus 로고
    • Estimation of physiologic stresses with a nature tooth considering fibrous PDL structure
    • Atmaram GH, Mohammed H. Estimation of physiologic stresses with a nature tooth considering fibrous PDL structure. J Dent Res 1981;60:873-7.
    • (1981) J Dent Res , vol.60 , pp. 873-877
    • Atmaram, G.H.1    Mohammed, H.2
  • 25
    • 0023868463 scopus 로고
    • On the dependence of the elasticity and strength of cancellous bone on apparent density
    • Rice JC, Cowin SC, Bowman JA. On the dependence of the elasticity and strength of cancellous bone on apparent density. J Biomech 1988;21:155-68.
    • (1988) J Biomech , vol.21 , pp. 155-168
    • Rice, J.C.1    Cowin, S.C.2    Bowman, J.A.3
  • 26
    • 0020173242 scopus 로고
    • A model for the implant-bone interface characteristics of porous dental implants
    • Cook SD, Klawitter JJ, Weinstein AM. A model for the implant-bone interface characteristics of porous dental implants. J Dent Res 1982;61:1006-9.
    • (1982) J Dent Res , vol.61 , pp. 1006-1009
    • Cook, S.D.1    Klawitter, J.J.2    Weinstein, A.M.3
  • 27
  • 28
    • 0017600568 scopus 로고
    • A mathematical model of an in vitro human mandible
    • Knoell AC. A mathematical model of an in vitro human mandible. J Biomech 1977;10:159-66.
    • (1977) J Biomech , vol.10 , pp. 159-166
    • Knoell, A.C.1
  • 29
    • 0024726781 scopus 로고
    • Finite element method simulation of bone resorption beneath a complete denture
    • Maeda Y, Wood WW. Finite element method simulation of bone resorption beneath a complete denture. J Dent Res 1989;68:1370-3.
    • (1989) J Dent Res , vol.68 , pp. 1370-1373
    • Maeda, Y.1    Wood, W.W.2
  • 30
  • 32
    • 0029303148 scopus 로고
    • Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis
    • Lewinstein I, Banks-Sills L, Eliasi R. Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. Int J Oral Maxillofac Implants 1995;10:355-66.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 355-366
    • Lewinstein, I.1    Banks-Sills, L.2    Eliasi, R.3
  • 34
    • 0028712150 scopus 로고
    • Aparametric finite element analysis study of the stresses in an endosseous implant
    • Lewis G. Aparametric finite element analysis study of the stresses in an endosseous implant. Biomed Mater Eng 1994;4:495-502.
    • (1994) Biomed Mater Eng , vol.4 , pp. 495-502
    • Lewis, G.1
  • 35
    • 0026096845 scopus 로고
    • Mechanical properties of metaphysical bone in the proximal femur
    • Lotz JC, Gerhart YN, Hayes WC. Mechanical properties of metaphysical bone in the proximal femur. J Biomech 1991;24:317-29.
    • (1991) J Biomech , vol.24 , pp. 317-329
    • Lotz, J.C.1    Gerhart, Y.N.2    Hayes, W.C.3
  • 36
    • 0040569959 scopus 로고    scopus 로고
    • Strain assessment by bone cells
    • Cowin SC. Strain assessment by bone cells. Tissue Eng 1988:181-6.
    • Tissue Eng , vol.1988 , pp. 181-186
    • Cowin, S.C.1
  • 38
    • 0039384915 scopus 로고    scopus 로고
    • The boundary design of mandibular model by means of the three-dimensional finite element method
    • Zhou X, Zhao Z, Zhao M, Fan Y. The boundary design of mandibular model by means of the three-dimensional finite element method. West China J Stomatol 1999;17:1-6.
    • (1999) West China J Stomatol , vol.17 , pp. 1-6
    • Zhou, X.1    Zhao, Z.2    Zhao, M.3    Fan, Y.4
  • 39
    • 0032038092 scopus 로고    scopus 로고
    • A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics
    • Teixeira ER, Sato Y, Shindoi N. A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil 1998;25:299-303.
    • (1998) J Oral Rehabil , vol.25 , pp. 299-303
    • Teixeira, E.R.1    Sato, Y.2    Shindoi, N.3
  • 40
    • 0033172944 scopus 로고    scopus 로고
    • The effectiveness of a new algorithm on a three-dimensional finite element model construction of bone trabeculae in implant biomechanics
    • Sato Y, Teixeira ER, Tsuga K, Shindoi N. The effectiveness of a new algorithm on a three-dimensional finite element model construction of bone trabeculae in implant biomechanics. J Oral REhabil 1999;26:640-3.
    • (1999) J Oral Rehabil , vol.26 , pp. 640-643
    • Sato, Y.1    Teixeira, E.R.2    Tsuga, K.3    Shindoi, N.4
  • 42
    • 0030147360 scopus 로고    scopus 로고
    • Factors affecting crestal bone loss with dental implants partially covered with a porous coating: A finite element analysis
    • Vaillancourt H, Pillar RM, McCammond D. Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis. Int J Oral Maxillofac Implants 1996;11:351-9.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 351-359
    • Vaillancourt, H.1    Pillar, R.M.2    McCammond, D.3
  • 44
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-8.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 45
  • 46
    • 0026976828 scopus 로고
    • Finite element stress and strain analysis of the bone surrounding a dental implant: Effect of variations in bone modulus
    • Clift SE, Fisher J, Watson CJ. Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus. Proc Inst Mech Eng [H] 1992;206:233-41.
    • (1992) Proc Inst Mech Eng [H] , vol.206 , pp. 233-241
    • Clift, S.E.1    Fisher, J.2    Watson, C.J.3
  • 47
    • 0040569958 scopus 로고    scopus 로고
    • Hong Kong: Hong Kong Tranfor Publishing Co Ltd
    • Geng J, Liu H. Exceptional prosthodontics. Hong Kong: Hong Kong Tranfor Publishing Co Ltd; 1999. p. 60-76.
    • (1999) Exceptional Prosthodontics , pp. 60-76
    • Geng, J.1    Liu, H.2
  • 48
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis - A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis - a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998;24:80-8.
    • (1998) J Oral Implantol , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 49
    • 0032198792 scopus 로고    scopus 로고
    • Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    • Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil 1998;25:847-58.
    • (1998) J Oral Rehabil , vol.25 , pp. 847-858
    • Barbier, L.1    Vander Sloten, J.2    Krzesinski, G.3    Schepers, E.4    Van Der Perre, G.5
  • 50
    • 0040569957 scopus 로고    scopus 로고
    • The study of effects of changes of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis
    • Zhang JK, Chen ZQ. The study of effects of changes of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis. West China J Stomatol 1998;16:274-8.
    • (1998) West China J Stomatol , vol.16 , pp. 274-278
    • Zhang, J.K.1    Chen, Z.Q.2
  • 51
    • 0029263858 scopus 로고
    • Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae
    • Benzing UR, Gall H, Weber H. Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae. Int J Oral Maxillofac Implants 1995;10:188-98.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 188-198
    • Benzing, U.R.1    Gall, H.2    Weber, H.3
  • 52
    • 0032197414 scopus 로고    scopus 로고
    • Influence of prosthesis material on stress distribution in bone and implant: A 3-dimensional finite element analysis
    • Stegaroiu R, Kusakari H, Nishiyama S, Miyakawa O. Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 1998;13:781-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 781-790
    • Stegaroiu, R.1    Kusakari, H.2    Nishiyama, S.3    Miyakawa, O.4
  • 53
    • 0026920402 scopus 로고
    • The influence of occlusal surface material on peak masticatory forces using ossointegrated implant-supported prostheses
    • Hobkirk JA, Psarros KJ. The influence of occlusal surface material on peak masticatory forces using ossointegrated implant-supported prostheses. Int J Oral Maxillofac Implants 1992;7:345-52.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 345-352
    • Hobkirk, J.A.1    Psarros, K.J.2
  • 54
    • 0026823748 scopus 로고
    • Determining the force absorption on quotient for restorative materials used in implant occlusal surfaces
    • Cibirka RM, Razzoog ME, Lang BR, Stohler CS. Determining the force absorption on quotient for restorative materials used in implant occlusal surfaces. J Prosthet Dent 1992;67:361-4.
    • (1992) J Prosthet Dent , vol.67 , pp. 361-364
    • Cibirka, R.M.1    Razzoog, M.E.2    Lang, B.R.3    Stohler, C.S.4
  • 55
    • 0024675462 scopus 로고
    • Bone resorption at the entry of osseointegrated implants - A biomechanical phenomenon. Finite element study
    • Mailath G, Stoiber B, Watzek G, Matejka M. Bone resorption at the entry of osseointegrated implants - a biomechanical phenomenon. Finite element study [in German]. Z Stomatol 1989;86:207-16.
    • (1989) Z Stomatol , vol.86 , pp. 207-216
    • Mailath, G.1    Stoiber, B.2    Watzek, G.3    Matejka, M.4
  • 57
    • 0024278938 scopus 로고
    • Biomechanical principles of endosseous screw implants
    • Stoiber B. Biomechanical principles of endosseous screw implants [in German]. Wien Klin Wochenschr 1988;100:522-4.
    • (1988) Wien Klin Wochenschr , vol.100 , pp. 522-524
    • Stoiber, B.1
  • 58
    • 0025581284 scopus 로고
    • Two-dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution
    • Matsushita Y, Kitoh M, Mizuta K, Ikeda H, Suetsugu T. Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J Oral Implantol 1990;16:611.
    • (1990) J Oral Implantol , vol.16 , pp. 611
    • Matsushita, Y.1    Kitoh, M.2    Mizuta, K.3    Ikeda, H.4    Suetsugu, T.5
  • 59
    • 0026305224 scopus 로고
    • A biomechanical rationale for the use of short implants
    • Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol 1991;17:126-31.
    • (1991) J Oral Implantol , vol.17 , pp. 126-131
    • Lum, L.B.1
  • 60
    • 0034088454 scopus 로고    scopus 로고
    • Use of short endosseous implants and an overdenture in the extremely resorbed mandible: A five-year retrospective study
    • Stellingsma C, Meijer HJ, Raghoebar GM. Use of short endosseous implants and an overdenture in the extremely resorbed mandible: a five-year retrospective study. J Oral Maxillofac Surg 2000;58:382-7; discussion 387-8.
    • (2000) J Oral Maxillofac Surg , vol.58 , pp. 382-387
    • Stellingsma, C.1    Meijer, H.J.2    Raghoebar, G.M.3
  • 61
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants 1989;4:333-40.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 333-340
    • Siegele, D.1    Soltesz, U.2
  • 62
    • 0029436116 scopus 로고
    • Comparative analysis of bone stresses and strains in the intoss dental implant with and without a flexible internal post
    • Clift SE, Fisher J, Edwards BN. Comparative analysis of bone stresses and strains in the Intoss dental implant with and without a flexible internal post. Proc Inst Mech Eng [H] 1995;209:139-47.
    • (1995) Proc Inst Mech Eng [H] , vol.209 , pp. 139-147
    • Clift, S.E.1    Fisher, J.2    Edwards, B.N.3
  • 63
    • 0025292949 scopus 로고
    • Mechanical and chemical bonding of artificial joints
    • Oonishi H. Mechanical and chemical bonding of artificial joints. Clin Mater 1990;5:217-33.
    • (1990) Clin Mater , vol.5 , pp. 217-233
    • Oonishi, H.1
  • 65
    • 0029415087 scopus 로고
    • Finite element analysis of crestal bone loss around porous-coated dental implants
    • Vaillancourt H, Pilliar RM, McCammond D. Finite element analysis of crestal bone loss around porous-coated dental implants. J Appl Biomater 1995;6:267-82.
    • (1995) J Appl Biomater , vol.6 , pp. 267-282
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 66
    • 0030147360 scopus 로고    scopus 로고
    • Factors affecting crestal bone loss with dental implants partially covered with a porous coating: A finite element analysis
    • Vaillancourt H, Pilliar RM, McCammond D. Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis. Int J Oral Maxillofac Implants 1996;11:351-9.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 351-359
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 67
    • 0033251930 scopus 로고    scopus 로고
    • Lack of integration of smooth titanium surfaces: A working hypothesis based on strains generated in the surrounding bone
    • Wiskott HW, Belser UC. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res 1999;10:429-44.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 429-444
    • Wiskott, H.W.1    Belser, U.C.2
  • 68
    • 0033212422 scopus 로고    scopus 로고
    • The implant neck: Smooth or provided with retention elements
    • Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405.
    • (1999) A Biomechanical Approach. Clin Oral Implants Res , vol.10 , pp. 394-405
    • Hansson, S.1
  • 69
    • 0026266914 scopus 로고
    • Three-dimensional finite element stress analysis in and around the Screw-Vent implant
    • Clelland NL, Ismail YH, Zaki HS, Pipko D. Three-dimensional finite element stress analysis in and around the Screw-Vent implant. Int J Oral Maxillofac Implants 1991;6:391-8.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, N.L.1    Ismail, Y.H.2    Zaki, H.S.3    Pipko, D.4
  • 70
    • 0027032178 scopus 로고
    • Load transfer from endosteal implants to supporting bone: An analysis using statics. Part one: Horizontal loading
    • Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part one: Horizontal loading. J Oral Implantol 1992;18:343-8.
    • (1992) J Oral Implantol , vol.18 , pp. 343-348
    • Lum, L.B.1    Osier, J.F.2
  • 71
    • 0026976828 scopus 로고
    • Finite element stress and strain analysis of the bone surrounding a dental implant: Effect of variations in bone modulus
    • Clift SE, Fisher J, Watson CJ. Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus. Proc Inst Mech Eng [H] 1992;206:233-41.
    • (1992) Proc Inst Mech Eng [H] , vol.206 , pp. 233-241
    • Clift, S.E.1    Fisher, J.2    Watson, C.J.3
  • 72
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-11.
    • (1997) J Oral Implantol , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 73
    • 0030338099 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function
    • Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent 1996;76:633-40.
    • (1996) J Prosthet Dent , vol.76 , pp. 633-640
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3    Felton, D.A.4
  • 74
    • 0030209046 scopus 로고    scopus 로고
    • The three-dimensional bone interface of an osseointegrated implant. I: A morphometric evaluation in initial healing
    • Wadamoto M, Akagawa Y, Sato Y, Kubo T. The three-dimensional bone interface of an osseointegrated implant. I: a morphometric evaluation in initial healing. J Prosthet Dent 1996;76:170-5.
    • (1996) J Prosthet Dent , vol.76 , pp. 170-175
    • Wadamoto, M.1    Akagawa, Y.2    Sato, Y.3    Kubo, T.4
  • 75
    • 0027653288 scopus 로고
    • Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant
    • Clelland NL, Lee JK, Bimbenet OC, Gilat A. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J Prosthodont 1993;2:183-9.
    • (1993) J Prosthodont , vol.2 , pp. 183-189
    • Clelland, N.L.1    Lee, J.K.2    Bimbenet, O.C.3    Gilat, A.4
  • 76
    • 0027829234 scopus 로고
    • Nonlinear finite element contact analysis of dental implant components
    • Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8:655-61.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 77
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jorneus, L.1    Jemt, T.2    Carlsson, L.3
  • 80
    • 0029185973 scopus 로고
    • The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?
    • Tan KBC. The clinical significance of distortion in implant prosthodontics: is there such a thing as passive fit? Ann Acad Med Singapore 1995;24:138-57.
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 138-157
    • Tan, K.B.C.1
  • 82
    • 0028437836 scopus 로고
    • Deflection of superstructure and stress concentrations in the IMZ implant system
    • Holmes DC, Haganman CR, Aquilino SA. Deflection of superstructure and stress concentrations in the IMZ implant system. Int J Prosthodont 1994;7:239-46.
    • (1994) Int J Prosthodont , vol.7 , pp. 239-246
    • Holmes, D.C.1    Haganman, C.R.2    Aquilino, S.A.3
  • 83
    • 0027031544 scopus 로고
    • Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis
    • Holmes DC, Grigsby WR, Goel VK, Keller JC. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis. Int J Oral Maxillofac Implants 1992;7:450-8.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 450-458
    • Holmes, D.C.1    Grigsby, W.R.2    Goel, V.K.3    Keller, J.C.4
  • 84
  • 87
    • 0030224418 scopus 로고    scopus 로고
    • Comparison of stress distribution around vertical and angled implants with finite-element analysis
    • Canay S, Hersek N, Akpinar I, Asik Z. Comparison of stress distribution around vertical and angled implants with finite-element analysis. Quintessence Int 1996;27:591-8.
    • (1996) Quintessence Int , vol.27 , pp. 591-598
    • Canay, S.1    Hersek, N.2    Akpinar, I.3    Asik, Z.4
  • 88
    • 0027792619 scopus 로고
    • A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis
    • Kregzde M. A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis. Int J Oral Maxillofac Implants 1993;8:662-73.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 662-673
    • Kregzde, M.1
  • 89
    • 0033158247 scopus 로고    scopus 로고
    • Influence of mandibular superstructure shape on implant stresses during simulated posterior biting
    • Korioth TW, Johann AR. Influence of mandibular superstructure shape on implant stresses during simulated posterior biting. J Prosthet Dent 1999;82:67-72.
    • (1999) J Prosthet Dent , vol.82 , pp. 67-72
    • Korioth, T.W.1    Johann, A.R.2
  • 90
    • 0031598192 scopus 로고    scopus 로고
    • Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method
    • Young FA, Williams KR, Draughn R, Strohaver R. Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method. Dent Mater 1998;14:37-43.
    • (1998) Dent Mater , vol.14 , pp. 37-43
    • Young, F.A.1    Williams, K.R.2    Draughn, R.3    Strohaver, R.4
  • 91
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    • Sertgöz A, Güvener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent 1996;76:165-9.
    • (1996) J Prosthet Dent , vol.76 , pp. 165-169
    • Sertgöz, A.1    Güvener, S.2
  • 92
    • 0030322726 scopus 로고    scopus 로고
    • A prospective 15-year follow-up study of mandibular fixed prostheses supported by ossointegrated implants. Clinical results and marginal bone loss
    • Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by ossointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res 1996;7:329-36.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 329-336
    • Lindquist, L.W.1    Carlsson, G.E.2    Jemt, T.3
  • 93
    • 0027620595 scopus 로고
    • A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible
    • Meijer HJ, Starmans FJ, Steen WH, Bosman F. A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible. Arch Oral Biol 1993;38:491-6.
    • (1993) Arch Oral Biol , vol.38 , pp. 491-496
    • Meijer, H.J.1    Starmans, F.J.2    Steen, W.H.3    Bosman, F.4
  • 94
    • 0028083161 scopus 로고
    • Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure
    • Meijer HJ, Starmans FJ, Steen WH, Bosman F. Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure. J Oral Rehabil 1994;21:47-56.
    • (1994) J Oral Rehabil , vol.21 , pp. 47-56
    • Meijer, H.J.1    Starmans, F.J.2    Steen, W.H.3    Bosman, F.4
  • 95
    • 0030278657 scopus 로고    scopus 로고
    • Loading conditions of endosseous implants in an edentulous human mandible: A three-dimensional, finite-element study
    • Meijer HJ, Starmans FJ, Steen WH, Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three-dimensional, finite-element study. J Oral Rehabil 1996;23:757-63.
    • (1996) J Oral Rehabil , vol.23 , pp. 757-763
    • Meijer, H.J.1    Starmans, F.J.2    Steen, W.H.3    Bosman, F.4
  • 96
    • 0027017737 scopus 로고
    • Finite element analysis (FEA) studies in 2.5-mm round bar design: The effects of bar length and material composition on bar failure
    • Bidez MW, Chen Y, McLoughlin SW, English CE. Finite element analysis (FEA) studies in 2.5-mm round bar design: the effects of bar length and material composition on bar failure. J Oral Implantol 1992;18:122-8.
    • (1992) J Oral Implantol , vol.18 , pp. 122-128
    • Bidez, M.W.1    Chen, Y.2    McLoughlin, S.W.3    English, C.E.4
  • 99
    • 0032060144 scopus 로고    scopus 로고
    • Mandibular implant-retained overdenture: Finite element analysis of two anchorage systems
    • Menicucci G, Lorenzetti M, Pera P, Preti G. Mandibular implant-retained overdenture: finite element analysis of two anchorage systems. Int J Oral Maxillofac Implants 1998;13:369-76.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 369-376
    • Menicucci, G.1    Lorenzetti, M.2    Pera, P.3    Preti, G.4
  • 101
    • 0025500307 scopus 로고
    • Modification of osseointegrated implants for distal-extension prostheses
    • el Charkawi HG, el Wakad MT, Naser ME. Modification of osseointegrated implants for distal-extension prostheses. J Prosthet Dent 1990;64:469-72.
    • (1990) J Prosthet Dent , vol.64 , pp. 469-472
    • El Charkawi, H.G.1    El Wakad, M.T.2    Naser, M.E.3
  • 102
    • 0027620440 scopus 로고
    • Finite element stress analysis of tooth-to-implant fixed partial denture designs
    • Misch CM, Ismail YH. Finite element stress analysis of tooth-to-implant fixed partial denture designs. J Prosthodont 1993;2:83-92.
    • (1993) J Prosthodont , vol.2 , pp. 83-92
    • Misch, C.M.1    Ismail, Y.H.2
  • 103
    • 0029439742 scopus 로고
    • Comparative stress analyses of fixed free-end osseointegrated prostheses using the finite element method
    • Melo C, Matsushita Y, Koyano K, Hirowatari H, Suetsugu T. Comparative stress analyses of fixed free-end osseointegrated prostheses using the finite element method. J Oral implantol 1995;21:290-4.
    • (1995) J Oral Implantol , vol.21 , pp. 290-294
    • Melo, C.1    Matsushita, Y.2    Koyano, K.3    Hirowatari, H.4    Suetsugu, T.5
  • 104
    • 0031264284 scopus 로고    scopus 로고
    • Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients. Part 1: Laboratory and clinical studies
    • Gross M, Laufer BZ. Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients. Part 1: laboratory and clinical studies. J Oral Rehabil 1997;24:863-70.
    • (1997) J Oral Rehabil , vol.24 , pp. 863-870
    • Gross, M.1    Laufer, B.Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.