메뉴 건너뛰기




Volumn 92, Issue 1, 2010, Pages 78-85

Polyethylene wear debris produced in a knee simulator model: Effect of crosslinking and counterface material

Author keywords

Ceramic; Crosslinking; Debris; Knee; Polyethylene

Indexed keywords

CERAMIC; COUNTER-FACE MATERIALS; CROSSLINKED PE; KNEE SIMULATORS; MORPHOLOGICAL CHANGES; PE CROSSLINKING; POLYETHYLENE WEAR; SUBMICRON; TOTAL HIP REPLACEMENTS; TOTAL KNEE REPLACEMENT; WEAR DEBRIS; WEAR SIMULATION;

EID: 74749086276     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31491     Document Type: Article
Times cited : (13)

References (55)
  • 1
    • 85170151548 scopus 로고    scopus 로고
    • : Total joint replacement: Effects of materials and designs on osteolysis
    • Garino J, Beredjiklian P, editors, Mosby, New York: Elsevier;
    • Clarke I, Donaldson T, Jobe C. Chapter 1: Total joint replacement: Effects of materials and designs on osteolysis. In: Garino J, Beredjiklian P, editors. Adult Reconstruction and Arthroplasty: Core Knowledge in Orthopaedics. Mosby, New York: Elsevier; 2007. pp 1-40.
    • (2007) Adult Reconstruction and Arthroplasty: Core Knowledge in Orthopaedics , pp. 1-40
    • Clarke, I.1    Donaldson, T.2    Jobe, C.3
  • 2
    • 0000432016 scopus 로고    scopus 로고
    • Bearing surfaces
    • Callaghan JJ, Rosenberg A, Rubash H, editors, Philadelphia: Lippincott-Raven;
    • Schmalzreid TP, Clarke IC, McKellop H. Bearing surfaces. In: Callaghan JJ, Rosenberg A, Rubash H, editors. The Adult Hip. Philadelphia: Lippincott-Raven; 1998. pp 247-265.
    • (1998) The Adult Hip , pp. 247-265
    • Schmalzreid, T.P.1    Clarke, I.C.2    McKellop, H.3
  • 3
    • 34548707139 scopus 로고    scopus 로고
    • Highly crosslinked polyethylenes in hip replacements: Improved wear performance or paradox?
    • Williams PA, Yamamoto K, Masaoka T, Oonishi H, Clarke IC. Highly crosslinked polyethylenes in hip replacements: Improved wear performance or paradox? Tribol Trans 2007; 50:277-290.
    • (2007) Tribol Trans , vol.50 , pp. 277-290
    • Williams, P.A.1    Yamamoto, K.2    Masaoka, T.3    Oonishi, H.4    Clarke, I.C.5
  • 4
    • 0026311405 scopus 로고
    • Tribology of total artificial joints
    • Fisher J, Dowson D. Tribology of total artificial joints. Proc Inst Mech Eng [H] 1991;205:73-79.
    • (1991) Proc Inst Mech Eng [H] , vol.205 , pp. 73-79
    • Fisher, J.1    Dowson, D.2
  • 5
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999;17:157-167.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 7
    • 19044373042 scopus 로고    scopus 로고
    • The comparison of the wear behavior of four different types of crosslinked acetabular components
    • Muratoglu OK. The comparison of the wear behavior of four different types of crosslinked acetabular components. J Orthop Res 2001;19:1210.
    • (2001) J Orthop Res , vol.19 , pp. 1210
    • Muratoglu, O.K.1
  • 8
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 2001;16:149-160.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 9
    • 33749866654 scopus 로고    scopus 로고
    • Wear and toughness of crosslinked polyethylene for total knee replacements: A study using a simulator and small-punch testing
    • Akagi M, Asano T, Clarke IC, Niiyama N, Kyomoto M, Nakamura T, Hamanishi C. Wear and toughness of crosslinked polyethylene for total knee replacements: A study using a simulator and small-punch testing. J Orthop Res 2006;24:2021-2027.
    • (2006) J Orthop Res , vol.24 , pp. 2021-2027
    • Akagi, M.1    Asano, T.2    Clarke, I.C.3    Niiyama, N.4    Kyomoto, M.5    Nakamura, T.6    Hamanishi, C.7
  • 10
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • Wang A, Essner A, Polineni VK, Stark C, Dumbleton JH. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribol Int 1998;31:17-33.
    • (1998) Tribol Int , vol.31 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 11
    • 33745533512 scopus 로고    scopus 로고
    • Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation
    • Tsukamoto R, Chen S, Asano T, Ogino M, Shoji H, Nakamura T, Clarke IC. Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation. Acta Orthop 2006;77:505-511.
    • (2006) Acta Orthop , vol.77 , pp. 505-511
    • Tsukamoto, R.1    Chen, S.2    Asano, T.3    Ogino, M.4    Shoji, H.5    Nakamura, T.6    Clarke, I.C.7
  • 12
    • 35548992847 scopus 로고    scopus 로고
    • Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties
    • Asano T, Akagi M, Clarke IC, Masuda S, Ishii T, Nakamura T. Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties. J Biomed Mater Res B Appl Biomater 2007;83:615-622.
    • (2007) J Biomed Mater Res B Appl Biomater , vol.83 , pp. 615-622
    • Asano, T.1    Akagi, M.2    Clarke, I.C.3    Masuda, S.4    Ishii, T.5    Nakamura, T.6
  • 16
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement
    • Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng [H] 2000;214:21-37.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 17
    • 4744355541 scopus 로고    scopus 로고
    • The role of macrophages in osteolysis of total joint replacement
    • Ingham E, Fisher J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005;26:1271-1286.
    • (2005) Biomaterials , vol.26 , pp. 1271-1286
    • Ingham, E.1    Fisher, J.2
  • 19
    • 1542268872 scopus 로고    scopus 로고
    • The influence of molecular weight, crosslinking and counterface roughness on TNF-α production by macrophages in response to ultra high molecular weight polyethylene particles
    • Ingram JH, Stone M, Fisher J, Ingham E. The influence of molecular weight, crosslinking and counterface roughness on TNF-α production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials 2004; 25:3511-3522.
    • (2004) Biomaterials , vol.25 , pp. 3511-3522
    • Ingram, J.H.1    Stone, M.2    Fisher, J.3    Ingham, E.4
  • 20
    • 0036023690 scopus 로고    scopus 로고
    • Comparison of the biological activity of grade GUR 1120 and GUR 415HP UHMWPE wear debris
    • Ingram J, Matthews JB, Tipper J, Stone M, Fisher J, Ingham E. Comparison of the biological activity of grade GUR 1120 and GUR 415HP UHMWPE wear debris. Biomed Mater Eng 2002;12:177-188.
    • (2002) Biomed Mater Eng , vol.12 , pp. 177-188
    • Ingram, J.1    Matthews, J.B.2    Tipper, J.3    Stone, M.4    Fisher, J.5    Ingham, E.6
  • 23
    • 0035002965 scopus 로고    scopus 로고
    • Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study
    • Yamamoto K, Clarke IC, Masaoka T, Oonishi H, Williams PA, Good VD, Imakiire A. Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study. J Biomed Mater Res 2001;56:65-73.
    • (2001) J Biomed Mater Res , vol.56 , pp. 65-73
    • Yamamoto, K.1    Clarke, I.C.2    Masaoka, T.3    Oonishi, H.4    Williams, P.A.5    Good, V.D.6    Imakiire, A.7
  • 24
    • 0036116447 scopus 로고    scopus 로고
    • Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
    • Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng [H] 2002; 216:111-122.
    • (2002) Proc Inst Mech Eng [H] , vol.216 , pp. 111-122
    • Endo, M.1    Tipper, J.L.2    Barton, D.C.3    Stone, M.H.4    Ingham, E.5    Fisher, J.6
  • 25
    • 34548707139 scopus 로고    scopus 로고
    • Highly crosslinked polyethylenes in hip replacements: Improved wear performance or paradox?
    • Williams P, Yamamoto K, Oonishi H, Clarke I. Highly crosslinked polyethylenes in hip replacements: Improved wear performance or paradox? Tribol Trans 2007;50:277-290.
    • (2007) Tribol Trans , vol.50 , pp. 277-290
    • Williams, P.1    Yamamoto, K.2    Oonishi, H.3    Clarke, I.4
  • 27
    • 0032401792 scopus 로고    scopus 로고
    • Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro
    • Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. Biomaterials 1998;19:2297-2302.
    • (1998) Biomaterials , vol.19 , pp. 2297-2302
    • Green, T.R.1    Fisher, J.2    Stone, M.3    Wroblewski, B.M.4    Ingham, E.5
  • 28
    • 0033814272 scopus 로고    scopus 로고
    • Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles
    • Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res 2000;53:490-497.
    • (2000) J Biomed Mater Res , vol.53 , pp. 490-497
    • Green, T.R.1    Fisher, J.2    Matthews, J.B.3    Stone, M.H.4    Ingham, E.5
  • 32
    • 0036187642 scopus 로고    scopus 로고
    • Factors affecting polyethylene wear in total knee arthroplasty
    • Kuster MS, Stachowiak GW. Factors affecting polyethylene wear in total knee arthroplasty. Orthopedics 2002;25 (2 Suppl):s235-s242.
    • (2002) Orthopedics , vol.25 , Issue.2 SUPPL.
    • Kuster, M.S.1    Stachowiak, G.W.2
  • 33
    • 0031544587 scopus 로고    scopus 로고
    • Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses
    • Blunn GW, Joshi AB, Minns RJ, Lidgren L, Lilley P, Ryd L, Engelbrecht E, Walker PS. Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J Arthroplasty 1997; 12:281-290.
    • (1997) J Arthroplasty , vol.12 , pp. 281-290
    • Blunn, G.W.1    Joshi, A.B.2    Minns, R.J.3    Lidgren, L.4    Lilley, P.5    Ryd, L.6    Engelbrecht, E.7    Walker, P.S.8
  • 34
    • 0016899064 scopus 로고
    • Wear and conformity in total knee replacement
    • Trent PS, Walker PS. Wear and conformity in total knee replacement. Wear 1976;36:175-187.
    • (1976) Wear , vol.36 , pp. 175-187
    • Trent, P.S.1    Walker, P.S.2
  • 36
    • 0031239130 scopus 로고    scopus 로고
    • Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements
    • Schmalzried TP, Campbell P, Schmitt AK, Brown IC, Amstutz HC. Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements. J Biomed Mater Res 1997;38:203-210.
    • (1997) J Biomed Mater Res , vol.38 , pp. 203-210
    • Schmalzried, T.P.1    Campbell, P.2    Schmitt, A.K.3    Brown, I.C.4    Amstutz, H.C.5
  • 37
    • 0028501856 scopus 로고
    • Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses
    • Schmalzried TP, Jasty M, Rosenberg A, Harris WH. Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. J Appl Biomater 1994;5:185-190.
    • (1994) J Appl Biomater , vol.5 , pp. 185-190
    • Schmalzried, T.P.1    Jasty, M.2    Rosenberg, A.3    Harris, W.H.4
  • 38
    • 33747434108 scopus 로고    scopus 로고
    • Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators
    • Tipper JL, Galvin AL, Williams S, McEwen HM, Stone MH, Ingham E, Fisher J. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. J Biomed Mater Res A 2006;78:473-480.
    • (2006) J Biomed Mater Res A , vol.78 , pp. 473-480
    • Tipper, J.L.1    Galvin, A.L.2    Williams, S.3    McEwen, H.M.4    Stone, M.H.5    Ingham, E.6    Fisher, J.7
  • 39
    • 2342552077 scopus 로고    scopus 로고
    • Bearing surface options for total hip replacement in young patients
    • Heisel C, Silva M, Schmalzried TP. Bearing surface options for total hip replacement in young patients. Instr Course Lect 2004;53:49-65.
    • (2004) Instr Course Lect , vol.53 , pp. 49-65
    • Heisel, C.1    Silva, M.2    Schmalzried, T.P.3
  • 41
    • 0035053741 scopus 로고    scopus 로고
    • Influence of polyethylene and femoral head surface quality on wear: A retrieval study
    • Haraguchi K, Sugano N, Nishii T, Sakai T, Yoshikawa H, Ohzono K. Influence of polyethylene and femoral head surface quality on wear: A retrieval study. Int Orthop 2001;25: 29-34.
    • (2001) Int Orthop , vol.25 , pp. 29-34
    • Haraguchi, K.1    Sugano, N.2    Nishii, T.3    Sakai, T.4    Yoshikawa, H.5    Ohzono, K.6
  • 43
  • 44
    • 62349085896 scopus 로고    scopus 로고
    • Ceramic versus cobalt-chrome femoral components; Wear of polyethylene insert in total knee prosthesis
    • Oonishi H, Ueno M, Kim SC, Iwamoto M, Kyomoto M. Ceramic versus cobalt-chrome femoral components; Wear of polyethylene insert in total knee prosthesis. J Arthroplasty 2008;24:374-382.
    • (2008) J Arthroplasty , vol.24 , pp. 374-382
    • Oonishi, H.1    Ueno, M.2    Kim, S.C.3    Iwamoto, M.4    Kyomoto, M.5
  • 49
    • 38749121013 scopus 로고    scopus 로고
    • Wear behavior and wear debris distribution of UHMWPE against Si3N4 ball in bi-directional sliding
    • Ge SR, Wang SB, Gitis N, Vinogradov M, Xiao J. Wear behavior and wear debris distribution of UHMWPE against Si3N4 ball in bi-directional sliding. Wear 2008264:571-578.
    • Wear 2008264 , pp. 571-578
    • Ge, S.R.1    Wang, S.B.2    Gitis, N.3    Vinogradov, M.4    Xiao, J.5
  • 50
    • 74749088441 scopus 로고    scopus 로고
    • A unified approach for evaluation of UHMWPE performance in a hip simulator using wear volume and debris size distribution: Effect of fabrication method
    • San Diego, California, February 11-14
    • Williams P, Clarke I. A unified approach for evaluation of UHMWPE performance in a hip simulator using wear volume and debris size distribution: Effect of fabrication method. Proceedings of the 53rd Annual Meeting of the Orthopaedic Research Socciety, San Diego, California, February 11-14, 2007.
    • (2007) Proceedings of the 53rd Annual Meeting of the Orthopaedic Research Socciety
    • Williams, P.1    Clarke, I.2
  • 51
    • 0035124730 scopus 로고    scopus 로고
    • Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene
    • Endo MM, Barbour PS, Barton DC, Fisher J, Tipper JL, Ingham E, Stone MH. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Biomed Mater Eng 2001;11:23-35.
    • (2001) Biomed Mater Eng , vol.11 , pp. 23-35
    • Endo, M.M.1    Barbour, P.S.2    Barton, D.C.3    Fisher, J.4    Tipper, J.L.5    Ingham, E.6    Stone, M.H.7
  • 52
    • 0035361147 scopus 로고    scopus 로고
    • The quantitative assessment of UHMWPE wear debris produced in hip simulator testing: The influence of head material and roughness, motion and loading
    • Elfick APD, Smith SL, Green SM, Unsworth A. The quantitative assessment of UHMWPE wear debris produced in hip simulator testing: The influence of head material and roughness, motion and loading. Wear 2001;249:517-527.
    • (2001) Wear , vol.249 , pp. 517-527
    • Elfick, A.P.D.1    Smith, S.L.2    Green, S.M.3    Unsworth, A.4
  • 53
    • 65749119251 scopus 로고    scopus 로고
    • Understanding polyethylene wear mechanisms by modeling of debris size distributions
    • Williams PA, Clarke IC. Understanding polyethylene wear mechanisms by modeling of debris size distributions. Wear 17th Int Conf Wear Mater 2009;267:646-652.
    • (2009) Wear 17th Int Conf Wear Mater , vol.267 , pp. 646-652
    • Williams, P.A.1    Clarke, I.C.2
  • 54
    • 0035065827 scopus 로고    scopus 로고
    • Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups
    • Affatato S, Vandelli C, Bordini B, Toni A. Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups. Proc Inst Mech Eng [H] 2001;215:107-111.
    • (2001) Proc Inst Mech Eng [H] , vol.215 , pp. 107-111
    • Affatato, S.1    Vandelli, C.2    Bordini, B.3    Toni, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.