메뉴 건너뛰기




Volumn 56, Issue 1, 2001, Pages 65-73

Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to γ radiation dose in simulator study

Author keywords

Crosslinked polyethylene; Hip simulator; Scanning electron microcroscopy; Total hip arthroplasty; Wear debris

Indexed keywords

COMPUTER SIMULATION; MOLECULAR WEIGHT; MORPHOLOGY; RADIATION;

EID: 0035002965     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/1097-4636(200107)56:1<65::AID-JBM1069>3.0.CO;2-Z     Document Type: Article
Times cited : (31)

References (27)
  • 1
    • 0033972562 scopus 로고    scopus 로고
    • Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components
    • Lewis G. Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components. J Bone Jt Surg Am 2000;82:281-287.
    • (2000) J Bone Jt Surg Am , vol.82 , pp. 281-287
    • Lewis, G.1
  • 2
    • 0015894056 scopus 로고
    • The effects of friction and wear in artificial joints
    • Walker PS, Bullough PG. The effects of friction and wear in artificial joints. Orthop Clin North Am 1973;4:275-293.
    • (1973) Orthop Clin North Am , vol.4 , pp. 275-293
    • Walker, P.S.1    Bullough, P.G.2
  • 3
    • 0015875229 scopus 로고
    • The measurement and effects of friction and wear in artificial hip joints
    • Walker PS, Salvati E. The measurement and effects of friction and wear in artificial hip joints. J Biomed Mater Res 1973;7: 327-342.
    • (1973) J Biomed Mater Res , vol.7 , pp. 327-342
    • Walker, P.S.1    Salvati, E.2
  • 7
    • 0033065656 scopus 로고    scopus 로고
    • Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator
    • McKellop HA, Shen FW, Campbell P, Ota T. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. J Orthop Res 1999;17:329-339.
    • (1999) J Orthop Res , vol.17 , pp. 329-339
    • McKellop, H.A.1    Shen, F.W.2    Campbell, P.3    Ota, T.4
  • 8
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prosthesis
    • Wang A, Stark C, Dumbleton JH. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prosthesis. Proc Inst Mech Eng 1996;210:141-155.
    • (1996) Proc Inst Mech Eng , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 9
    • 0021805501 scopus 로고
    • Transfer wear of polymers during combined linear motion and load axis spin
    • Briscoe BJ, Stolarski TA. Transfer wear of polymers during combined linear motion and load axis spin. Wear 1985:104:121-137.
    • (1985) Wear , vol.104 , pp. 121-137
    • Briscoe, B.J.1    Stolarski, T.A.2
  • 11
    • 0030152397 scopus 로고
    • Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions
    • Wang A, Essner A, Stark C, Dumbleton JH. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions. Biomaterials 1995;17:865-871.
    • (1995) Biomaterials , vol.17 , pp. 865-871
    • Wang, A.1    Essner, A.2    Stark, C.3    Dumbleton, J.H.4
  • 14
    • 0004263771 scopus 로고    scopus 로고
    • Comparison of polyethylene wear and polyethylene debris generated on new hip simulator versus direct measurements of in vivo wear
    • Marchant RE, editor. New Orleans, LA. Minneapolis, MN: Society for Biomaterials.
    • Bragdon CB, O'Connor DO, Lowenstein JD, Jasty M. Comparison of polyethylene wear and polyethylene debris generated on new hip simulator versus direct measurements of in vivo wear. In: Marchant RE, editor. Proceeding of the 23rd Annual Meeting, Society for Biomaterials, Vol. 20; 1997; New Orleans, LA. Minneapolis, MN: Society for Biomaterials. p 153.
    • (1997) Proceeding of the 23rd Annual Meeting, Society for Biomaterials , vol.20 , pp. 153
    • Bragdon, C.B.1    O'Connor, D.O.2    Lowenstein, J.D.3    Jasty, M.4
  • 17
    • 0031912659 scopus 로고    scopus 로고
    • Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation
    • Besong AA, Tipper JL, Ingham E, Stone MH, Wroblewski BM, Fisher J. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. J Bone Jt Surg 1998;80B:340-344.
    • (1998) J Bone Jt Surg , vol.80 B , pp. 340-344
    • Besong, A.A.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Wroblewski, B.M.5    Fisher, J.6
  • 18
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999;17:157-167.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 19
    • 0001903996 scopus 로고
    • The low wear of cross-linked polyethylene socket in total hip prosthesis
    • Wise DL, Trantolo DJ, Altobelli DE, Yaszemski MJ, Gresser JD, Schwartz ER, editors. New York: Marcel Dekker
    • Oonishi H, Takayama Y, Tsuji E. The low wear of cross-linked polyethylene socket in total hip prosthesis. In: Wise DL, Trantolo DJ, Altobelli DE, Yaszemski MJ, Gresser JD, Schwartz ER, editors. Encyclopedic handbook of biomaterials and bioengineering. Part A, Volume 2. New York: Marcel Dekker; 1995. p 1853-1868.
    • (1995) Encyclopedic Handbook of Biomaterials and Bioengineering. , vol.2 , Issue.PART A , pp. 1853-1868
    • Oonishi, H.1    Takayama, Y.2    Tsuji, E.3
  • 20
    • 0031027550 scopus 로고    scopus 로고
    • The optimum dose of gamma radiation - Heavy doses to low wear polyethylene in total hip prosthesis
    • Oonishi H, Kuno M, Tsuji E, Fujisawa A. The optimum dose of gamma radiation - heavy doses to low wear polyethylene in total hip prosthesis. J Mater Sci Mater Med 1997;8:11-18.
    • (1997) J Mater Sci Mater Med , vol.8 , pp. 11-18
    • Oonishi, H.1    Kuno, M.2    Tsuji, E.3    Fujisawa, A.4
  • 21
    • 0002989262 scopus 로고    scopus 로고
    • Forces transmitted by joints in human body
    • Paul JP. Forces transmitted by joints in human body. Proc Inst Mech Eng 1996;181:8-15.
    • (1996) Proc Inst Mech Eng , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 22
    • 2342594291 scopus 로고    scopus 로고
    • SEM wear-mode comparison of extensively cross-linked PE-cups: In-vitro and ex-vivo
    • LaBerge M, Agrawal CM, editors. Providence, RI. Minneapolis, MN: Society for Biomaterials.
    • Yamamoto K, Oonishi H, Kawanabe K, Masuda S, Williams P, Yu L, Clarke IC. SEM wear-mode comparison of extensively cross-linked PE-cups: in-vitro and ex-vivo. In: LaBerge M, Agrawal CM, editors. Proceedings of the 25th Annual Meeting, Society for Biomaterials Vol. 22; 1999; Providence, RI. Minneapolis, MN: Society for Biomaterials. p 503.
    • (1999) Proceedings of the 25th Annual Meeting, Society for Biomaterials , vol.22 , pp. 503
    • Yamamoto, K.1    Oonishi, H.2    Kawanabe, K.3    Masuda, S.4    Williams, P.5    Yu, L.6    Clarke, I.C.7
  • 23
    • 0005638915 scopus 로고    scopus 로고
    • Physical, chemical study and biological safety test for UHMW polyethylene cross-linked by high-dose γ-irradiation
    • Fujisawa A, Masuda S, Oonishi H, Ikada Y, Clarke IC, Good V. Physical, chemical study and biological safety test for UHMW polyethylene cross-linked by high-dose γ-irradiation. J Jpn Soc Biomater 1998;16:29-35.
    • (1998) J Jpn Soc Biomater , vol.16 , pp. 29-35
    • Fujisawa, A.1    Masuda, S.2    Oonishi, H.3    Ikada, Y.4    Clarke, I.C.5    Good, V.6
  • 25
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene
    • Wroblewski BM, Siney PD, Dowson D, Collons SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene. J Bone Jt Surg 1996;78B:280-285.
    • (1996) J Bone Jt Surg , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collons, S.N.4
  • 26
    • 0018500913 scopus 로고
    • The effects of radiation sterilization on the properties of ultrahigh molecular weight polyethylene
    • Nusbaum HJ, Rose RM The effects of radiation sterilization on the properties of ultrahigh molecular weight polyethylene. J Biomed Mater Res 1979;13:557-576.
    • (1979) J Biomed Mater Res , vol.13 , pp. 557-576
    • Nusbaum, H.J.1    Rose, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.