메뉴 건너뛰기




Volumn 26, Issue 30, 2005, Pages 6034-6040

Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis

Author keywords

Alumina; In vivo test; Knee replacement; Polyethylene; Wear debris

Indexed keywords

ALUMINA; BIOLOGICAL ORGANS; CERAMIC MATERIALS; MEDICAL IMAGING; PARTICLE SIZE ANALYSIS; POLYETHYLENES; SCANNING ELECTRON MICROSCOPY; STERILIZATION (CLEANING); WEAR OF MATERIALS;

EID: 20444422532     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.biomaterials.2005.03.022     Document Type: Article
Times cited : (38)

References (27)
  • 1
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • H.G. Willert Reactions of the articular capsule to wear products of artificial joint prostheses J Biomed Mater Res 11 1977 157 164
    • (1977) J Biomed Mater Res , vol.11 , pp. 157-164
    • Willert, H.G.1
  • 2
    • 0030152803 scopus 로고    scopus 로고
    • Bone formation and bone resorption in failed total joint arthroplasties: Histomorphometric analysis with histochemical and immunohistochemical technique
    • Y. Kadoya, P.A. Revell, N. al-Saffar, A. Kobayashi, G. Scott, and M.A. Freeman Bone formation and bone resorption in failed total joint arthroplasties: histomorphometric analysis with histochemical and immunohistochemical technique J Orthop Res 14 1996 473 482
    • (1996) J Orthop Res , vol.14 , pp. 473-482
    • Kadoya, Y.1    Revell, P.A.2    Al-Saffar, N.3    Kobayashi, A.4    Scott, G.5    Freeman, M.A.6
  • 5
    • 0026527293 scopus 로고
    • Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prosthesis
    • G.A. Engh, K.A. Dwyer, and C.K. Hanes Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prosthesis J Bone Joint Surg 74B 1988 9 17
    • (1988) J Bone Joint Surg , vol.74 , pp. 9-17
    • Engh, G.A.1    Dwyer, K.A.2    Hanes, C.K.3
  • 6
    • 0032400845 scopus 로고    scopus 로고
    • Pathologic supracondylar fracture due to osteolytic pseudotumor of knee following cementless total knee replacement
    • J. Benevenia, F.Y. Lee, F. Buechel, and J.R. Parsons Pathologic supracondylar fracture due to osteolytic pseudotumor of knee following cementless total knee replacement J Biomed Mater Res 43 1998 473 477
    • (1998) J Biomed Mater Res , vol.43 , pp. 473-477
    • Benevenia, J.1    Lee, F.Y.2    Buechel, F.3    Parsons, J.R.4
  • 8
    • 0001388870 scopus 로고    scopus 로고
    • Meniscal-bearing knee replacement
    • Insall JN, Scott WN, editors. 3rd ed. Philadelphia: Churchill Livingstone;
    • Insall JN, Aglietti P, Baldini A, Easley ME. Meniscal-bearing knee replacement. In: Insall JN, Scott WN, editors. Surgery of the Knee, vol. 2, 3rd ed. Philadelphia: Churchill Livingstone; 2001. p. 1717-38.
    • (2001) Surgery of the Knee , vol.2 , pp. 1717-1738
    • Insall, J.N.1    Aglietti, P.2    Baldini, A.3    Easley, M.E.4
  • 10
    • 0026663034 scopus 로고
    • Alumina versus polyethylene in total knee arthroplasty
    • H. Oonishi, M. Aono, N. Murata, and S. Kushitani Alumina versus polyethylene in total knee arthroplasty Clin Orthop 282 1992 95 104
    • (1992) Clin Orthop , vol.282 , pp. 95-104
    • Oonishi, H.1    Aono, M.2    Murata, N.3    Kushitani, S.4
  • 11
    • 0033739555 scopus 로고    scopus 로고
    • The Bisurface total knee replacement: A unique design for flexion. Four-to-nine-year follow-up study
    • M. Akagi, T. Nakamura, Y. Matsusue, T. Ueo, K. Nishijyo, and E. Ohnishi The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study J Bone Joint Surg 82A 2000 1626 1633
    • (2000) J Bone Joint Surg , vol.82 , pp. 1626-1633
    • Akagi, M.1    Nakamura, T.2    Matsusue, Y.3    Ueo, T.4    Nishijyo, K.5    Ohnishi, E.6
  • 12
    • 13444275367 scopus 로고    scopus 로고
    • Comparison of the wear propeties of polyethylene plate in total knee prostheses using different femoral component materials
    • M. Ueno, K. Ikeuchi, T. Nakamura, and M. Akagi Comparison of the wear propeties of polyethylene plate in total knee prostheses using different femoral component materials Biocermics 15 2002 801 804
    • (2002) Biocermics , vol.15 , pp. 801-804
    • Ueno, M.1    Ikeuchi, K.2    Nakamura, T.3    Akagi, M.4
  • 13
    • 4644344420 scopus 로고    scopus 로고
    • Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties
    • Y. Minoda, A. Kobayashi, H. Iwaki, M. Miyaguchi, Y. Kadoya, H. Ohashi, and K. Takaoka Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties J Biomed Mater Res 71B 2004 1 6
    • (2004) J Biomed Mater Res , vol.71 , pp. 1-6
    • Minoda, Y.1    Kobayashi, A.2    Iwaki, H.3    Miyaguchi, M.4    Kadoya, Y.5    Ohashi, H.6    Takaoka, K.7
  • 14
    • 0021321419 scopus 로고
    • Treatment of primary osteoarthritis of the hip. a comparison of total joint and surface replacement arthroplasty
    • H.C. Amstutz, B.J. Thomas, R. Jinnah, W. Kim, T. Grogan, and C. Yale Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty J Bone Joint Surg 66A 1984 228 241
    • (1984) J Bone Joint Surg , vol.66 , pp. 228-241
    • Amstutz, H.C.1    Thomas, B.J.2    Jinnah, R.3    Kim, W.4    Grogan, T.5    Yale, C.6
  • 15
  • 16
    • 0030880257 scopus 로고    scopus 로고
    • Number of polyethylene particles and osteolysis in total joint replacements. a quantitative study using a tissue-digestion method
    • A. Kobayashi, M.A. Freeman, W. Bonfield, Y. Kadoya, T. Yamac, N. Al-Saffar, G. Scott, and P.A. Revell Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method J Bone Joint Surg 79B 1997 844 848
    • (1997) J Bone Joint Surg , vol.79 , pp. 844-848
    • Kobayashi, A.1    Freeman, M.A.2    Bonfield, W.3    Kadoya, Y.4    Yamac, T.5    Al-Saffar, N.6    Scott, G.7    Revell, P.A.8
  • 20
    • 0038441585 scopus 로고    scopus 로고
    • Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up
    • P. Hernigou, and T. Bahrami Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up J Bone Joint Surg 85B 2003 504 509
    • (2003) J Bone Joint Surg , vol.85 , pp. 504-509
    • Hernigou, P.1    Bahrami, T.2
  • 21
    • 0043172244 scopus 로고    scopus 로고
    • Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina
    • K. Tanaka, J. Tamura, K. Kawanabe, M. Shimizu, and T. Nakamura Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina J Bone Joint Surg 85B 2003 655 660
    • (2003) J Bone Joint Surg , vol.85 , pp. 655-660
    • Tanaka, K.1    Tamura, J.2    Kawanabe, K.3    Shimizu, M.4    Nakamura, T.5
  • 22
    • 0000672338 scopus 로고
    • Cementless alumina ceramic total knee prostheses
    • H. Oonishi, and T. Hasegawa Cementless alumina ceramic total knee prostheses Orthop Ceramic Implants 1 1981 157 160
    • (1981) Orthop Ceramic Implants , vol.1 , pp. 157-160
    • Oonishi, H.1    Hasegawa, T.2
  • 23
    • 0034333626 scopus 로고    scopus 로고
    • Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose
    • J.B. Matthews, A.A. Besong, T.R. Green, M.H. Stone, B.M. Wroblewski, J. Fisher, and E. Ingham Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose J Biomed Mater Res 52 2000 296 307
    • (2000) J Biomed Mater Res , vol.52 , pp. 296-307
    • Matthews, J.B.1    Besong, A.A.2    Green, T.R.3    Stone, M.H.4    Wroblewski, B.M.5    Fisher, J.6    Ingham, E.7
  • 24
    • 0036017230 scopus 로고    scopus 로고
    • Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation
    • S.Y. Yang, W. Ren, Y. Park, A. Sieving, S. Hsu, S. Nasser, and P.H. Wooley Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation Biomaterials 23 2002 3535 3543
    • (2002) Biomaterials , vol.23 , pp. 3535-3543
    • Yang, S.Y.1    Ren, W.2    Park, Y.3    Sieving, A.4    Hsu, S.5    Nasser, S.6    Wooley, P.H.7
  • 25
    • 0031148607 scopus 로고    scopus 로고
    • Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene
    • R.S. Pascaud, W.T. Evans, P.J. McCullagh, and D.P. FitzPatrick Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene Biomaterials 18 1997 727 735
    • (1997) Biomaterials , vol.18 , pp. 727-735
    • Pascaud, R.S.1    Evans, W.T.2    McCullagh, P.J.3    Fitzpatrick, D.P.4
  • 26
    • 0032438463 scopus 로고    scopus 로고
    • The impact of sterilization method on wear in knee arthroplasty
    • I.R. Williams, M.B. Mayor, and J.P. Collier The impact of sterilization method on wear in knee arthroplasty Clin Orthop 356 1998 170 180
    • (1998) Clin Orthop , vol.356 , pp. 170-180
    • Williams, I.R.1    Mayor, M.B.2    Collier, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.