메뉴 건너뛰기




Volumn 12, Issue 3, 1997, Pages 281-290

Wear in retrieved condylar knee arthroplasties: A comparison of wear in different designs of 280 retrieved condylar knee prostheses

Author keywords

Delamination; Knee arthroplasty; Polyethylene; Retrieved prostheses; Wear

Indexed keywords

POLYETHYLENE;

EID: 0031544587     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(97)90024-3     Document Type: Article
Times cited : (189)

References (33)
  • 1
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra high molecular weight components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness, and material on stresses in ultra high molecular weight components for total joint replacement. J Bone Joint Surg 68:1041, 1986
    • (1986) J Bone Joint Surg , vol.68 , pp. 1041
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 2
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
    • Hood RW, Wright TW, Burstein AH: Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 17:829, 1983
    • (1983) J Biomed Mater Res , vol.17 , pp. 829
    • Hood, R.W.1    Wright, T.W.2    Burstein, A.H.3
  • 3
    • 0025353276 scopus 로고
    • A prognosis for ultra high molecular weight polyethylene
    • Rose RM, Radin EL: A prognosis for ultra high molecular weight polyethylene. Biomaterials 11:63, 1990
    • (1990) Biomaterials , vol.11 , pp. 63
    • Rose, R.M.1    Radin, E.L.2
  • 5
    • 0028384735 scopus 로고
    • Optimisation of bearing geometry of total knees
    • Sathasivam S, Walker PS: Optimisation of bearing geometry of total knees. J Biomech 27:255, 1993
    • (1993) J Biomech , vol.27 , pp. 255
    • Sathasivam, S.1    Walker, P.S.2
  • 6
    • 0019364909 scopus 로고
    • The deformation and wear of plastic components in artificial knee joints
    • Walker PS, Ben-Dov M, Askew MJ, Pugh J: The deformation and wear of plastic components in artificial knee joints. Eng Med 10:33, 1981
    • (1981) Eng Med , vol.10 , pp. 33
    • Walker, P.S.1    Ben-Dov, M.2    Askew, M.J.3    Pugh, J.4
  • 7
    • 0026346472 scopus 로고
    • Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
    • Collier JP, Mayor MB, McNamara JL et al: Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273:232, 1991
    • (1991) Clin Orthop , vol.273 , pp. 232
    • Collier, J.P.1    Mayor, M.B.2    McNamara, J.L.3
  • 8
    • 0022107624 scopus 로고
    • The effect of conformity, thickness and material stresses in metal backed plastic implants
    • Bartel PL, Bicknell VC, Wright TM: The effect of conformity, thickness and material stresses in metal backed plastic implants. J Biomech Eng 107:193, 1985
    • (1985) J Biomech Eng , vol.107 , pp. 193
    • Bartel, P.L.1    Bicknell, V.C.2    Wright, T.M.3
  • 10
    • 0020433171 scopus 로고
    • The influence of total knee replacement design and stair climbing
    • Andriacchi TP, Galante JO, Ferrier RW: The influence of total knee replacement design and stair climbing. J Bone Joint Surg 64A:1328, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 1328
    • Andriacchi, T.P.1    Galante, J.O.2    Ferrier, R.W.3
  • 11
    • 0026350108 scopus 로고
    • The dominance of cyclic sliding in producing wear in total knee replacements
    • Blunn GW, Walker PS, Joshi A, Hardinge K: The dominance of cyclic sliding in producing wear in total knee replacements. Clin Orthop 274:253, 1991
    • (1991) Clin Orthop , vol.274 , pp. 253
    • Blunn, G.W.1    Walker, P.S.2    Joshi, A.3    Hardinge, K.4
  • 12
    • 0023697318 scopus 로고
    • Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses
    • Landy MM, Walker PS: Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 3:S73, 1988
    • (1988) J Arthroplasty , vol.3
    • Landy, M.M.1    Walker, P.S.2
  • 14
    • 0026347408 scopus 로고
    • Investigation of early surface delamination observed in retrieved heat pressed tibial inserts
    • Bloebaum RD, Nelson K, Dorr ID et al: Investigation of early surface delamination observed in retrieved heat pressed tibial inserts. Clin Orthop 269:120, 1991
    • (1991) Clin Orthop , vol.269 , pp. 120
    • Bloebaum, R.D.1    Nelson, K.2    Dorr, I.D.3
  • 15
    • 0023689745 scopus 로고
    • Analysis of surface damage in retrieved carbon-fibre reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements
    • Wright TM, Rimnac CM, Faris PM, Bansal M: Analysis of surface damage in retrieved carbon-fibre reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. J Bone Joint Surg 70A: 1312, 1988
    • (1988) J Bone Joint Surg , vol.70 A , pp. 1312
    • Wright, T.M.1    Rimnac, C.M.2    Faris, P.M.3    Bansal, M.4
  • 16
    • 9444254922 scopus 로고
    • Contact pressure dependence of wear rates of UHMWPE
    • Rostoker W, Galante JO: Contact pressure dependence of wear rates of UHMWPE. J Biomed Mater Res 13:857, 1979
    • (1979) J Biomed Mater Res , vol.13 , pp. 857
    • Rostoker, W.1    Galante, J.O.2
  • 17
    • 0026698866 scopus 로고
    • Massive femoral osteolysis and bony disintegration of a polyethylene bearing surface of a total knee replacement: A case report
    • Kilgus DJ, Funashashi TT, Campbell PA: Massive femoral osteolysis and bony disintegration of a polyethylene bearing surface of a total knee replacement: a case report. J Bone Joint Surg 74A:770, 1992
    • (1992) J Bone Joint Surg , vol.74 A , pp. 770
    • Kilgus, D.J.1    Funashashi, T.T.2    Campbell, P.A.3
  • 18
    • 0026569950 scopus 로고
    • Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement
    • Nolan JF, Bucknill TM: Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement. J Bone Joint Surg 74B:23, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 23
    • Nolan, J.F.1    Bucknill, T.M.2
  • 19
    • 0026655386 scopus 로고
    • Polyethylene wear in unicondylar knee prostheses: 106 retrieved Marmor, PCA and St. Georg tibial components compared
    • Blunn GW, Joshi AB, Lilley PA et al: Polyethylene wear in unicondylar knee prostheses: 106 retrieved Marmor, PCA and St. Georg tibial components compared. Acta Orthop Scand 63:247, 1992
    • (1992) Acta Orthop Scand , vol.63 , pp. 247
    • Blunn, G.W.1    Joshi, A.B.2    Lilley, P.A.3
  • 20
    • 0026574554 scopus 로고
    • Polyethylene wear in meniscal knee replacement: A one to nine year retrieval analysis of the Oxford knee
    • Argenson J, O'Connor JJ: Polyethylene wear in meniscal knee replacement: a one to nine year retrieval analysis of the Oxford knee. J Bone Joint Surg 74B:228, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 228
    • Argenson, J.1    O'Connor, J.J.2
  • 21
    • 0024103556 scopus 로고
    • Bearing surface design in total knee replacement
    • Walker PS: Bearing surface design in total knee replacement. Eng Med 17:149, 1988
    • (1988) Eng Med , vol.17 , pp. 149
    • Walker, P.S.1
  • 22
    • 0018101581 scopus 로고
    • Influence of design on the transmission of torque across knee prostheses
    • Werner F, Foster D, Murray DG: Influence of design on the transmission of torque across knee prostheses. J Bone Joint Surg 60A:342, 1978
    • (1978) J Bone Joint Surg , vol.60 A , pp. 342
    • Werner, F.1    Foster, D.2    Murray, D.G.3
  • 23
    • 0019963292 scopus 로고
    • The effect of knee-prosthesis geometry on cruciate ligament mechanics during flexion
    • Lew WD, Lewis JL: The effect of knee-prosthesis geometry on cruciate ligament mechanics during flexion. J Bone Joint Surg 64A:734, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 734
    • Lew, W.D.1    Lewis, J.L.2
  • 24
    • 0026356990 scopus 로고
    • Catastrophic wear of tibial polyethylene inserts
    • Kilgus DJ, Moreland JR, Finerman GA et al: Catastrophic wear of tibial polyethylene inserts. Clin Orthop 273:223, 1991
    • (1991) Clin Orthop , vol.273 , pp. 223
    • Kilgus, D.J.1    Moreland, J.R.2    Finerman, G.A.3
  • 25
    • 13044279915 scopus 로고
    • Stresses and surface damage in PCA and Total Condylar polyethylene components
    • Gunsallus KL, Bartel DL: Stresses and surface damage in PCA and Total Condylar polyethylene components. Trans 38th Annu Meet Orthop Res Soc 17:329, 1992
    • (1992) Trans 38th Annu Meet Orthop Res Soc , vol.17 , pp. 329
    • Gunsallus, K.L.1    Bartel, D.L.2
  • 26
    • 0342799094 scopus 로고
    • The behavior of UHMWPE when subjected to sterilization by ionizing radiation
    • Willert HG, Buckhorn EP (eds): Hogrefe & Huber, Toronto
    • Steicher RM: The behavior of UHMWPE when subjected to sterilization by ionizing radiation. p. 66. In Willert HG, Buckhorn EP (eds): Ultra high molecular weight polyethylene as biomaterial in orthopaedic surgery. Hogrefe & Huber, Toronto, 1991
    • (1991) Ultra High Molecular Weight Polyethylene As Biomaterial in Orthopaedic Surgery , pp. 66
    • Steicher, R.M.1
  • 28
  • 30
    • 0002738931 scopus 로고
    • Oxidation vs depth and time for polyethylene gamma sterilised in air
    • Saum KA: Oxidation vs depth and time for polyethylene gamma sterilised in air. Trans 40th Annu Meet Orthop Res Soc 19:174, 1994
    • (1994) Trans 40th Annu Meet Orthop Res Soc , vol.19 , pp. 174
    • Saum, K.A.1
  • 32
    • 0026202775 scopus 로고
    • Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation
    • Jahan MS, Wang C, Schwartz G, Davidson JA: Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation. J Biomed Mater Res 25:1005, 1991
    • (1991) J Biomed Mater Res , vol.25 , pp. 1005
    • Jahan, M.S.1    Wang, C.2    Schwartz, G.3    Davidson, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.