-
1
-
-
0024052338
-
An initial investigation of the bending and torsional properties of Nitinol root canal files
-
Walia H.M., Brantley W.A., and Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 14 (1988) 346-351
-
(1988)
J Endod
, vol.14
, pp. 346-351
-
-
Walia, H.M.1
Brantley, W.A.2
Gerstein, H.3
-
2
-
-
3042563899
-
Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study
-
Schäfer E., Schulz-Bongert U., and Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. J Endod 30 (2004) 432-435
-
(2004)
J Endod
, vol.30
, pp. 432-435
-
-
Schäfer, E.1
Schulz-Bongert, U.2
Tulus, G.3
-
3
-
-
0036517113
-
A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique
-
Chen J.L., and Messer H.H. A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique. Aust Dent J 47 (2002) 12-20
-
(2002)
Aust Dent J
, vol.47
, pp. 12-20
-
-
Chen, J.L.1
Messer, H.H.2
-
4
-
-
0035461551
-
The use of computed tomography when comparing nickel titanium and stainless steel files during preparation of simulated curved canals
-
Garip Y., and Gunday M. The use of computed tomography when comparing nickel titanium and stainless steel files during preparation of simulated curved canals. Int Endod J 34 (2001) 452-457
-
(2001)
Int Endod J
, vol.34
, pp. 452-457
-
-
Garip, Y.1
Gunday, M.2
-
5
-
-
0035433359
-
Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals
-
Schäfer E. Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 92 (2001) 215-220
-
(2001)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.92
, pp. 215-220
-
-
Schäfer, E.1
-
6
-
-
1542570495
-
Evaluation of single-use rotary nickel-titanium instruments
-
Arens F.C., Hoen M.M., Steiman H.R., and Dietz Jr. G.C. Evaluation of single-use rotary nickel-titanium instruments. J Endod 29 (2003) 664-666
-
(2003)
J Endod
, vol.29
, pp. 664-666
-
-
Arens, F.C.1
Hoen, M.M.2
Steiman, H.R.3
Dietz Jr., G.C.4
-
7
-
-
0031064647
-
Cyclic fatigue testing of nickel-titanium endodontic instruments
-
Pruett J.P., Clement D.J., and Carnes Jr. D.L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23 (1997) 77-85
-
(1997)
J Endod
, vol.23
, pp. 77-85
-
-
Pruett, J.P.1
Clement, D.J.2
Carnes Jr., D.L.3
-
8
-
-
0034157078
-
Defects in rotary nickel-titanium files after clinical use
-
Sattapan B., Nervo G.J., Palamara J.E., and Messer H.H. Defects in rotary nickel-titanium files after clinical use. J Endod 26 (2000) 161-165
-
(2000)
J Endod
, vol.26
, pp. 161-165
-
-
Sattapan, B.1
Nervo, G.J.2
Palamara, J.E.3
Messer, H.H.4
-
9
-
-
33644518234
-
Comparison of defects in ProFile and ProTaper systems after clinical use
-
Shen Y., Cheung G.S., Bian Z., and Peng B. Comparison of defects in ProFile and ProTaper systems after clinical use. J Endod 32 (2006) 61-65
-
(2006)
J Endod
, vol.32
, pp. 61-65
-
-
Shen, Y.1
Cheung, G.S.2
Bian, Z.3
Peng, B.4
-
11
-
-
0036527406
-
A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals
-
Hata G., Uemura M., Kato A.S., Imura N., Novo N.F., and Toda T. A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals. J Endod 28 (2002) 316-321
-
(2002)
J Endod
, vol.28
, pp. 316-321
-
-
Hata, G.1
Uemura, M.2
Kato, A.S.3
Imura, N.4
Novo, N.F.5
Toda, T.6
-
12
-
-
2442680167
-
K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved root of molars
-
Ankrum M.T., Hartwell G.R., and Truitt J.E. K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved root of molars. J Endod 30 (2004) 234-237
-
(2004)
J Endod
, vol.30
, pp. 234-237
-
-
Ankrum, M.T.1
Hartwell, G.R.2
Truitt, J.E.3
-
13
-
-
71049142478
-
Instrument fracture: mechanisms, removal of fragments, and clinical outcomes
-
Cheung G.S.P. Instrument fracture: mechanisms, removal of fragments, and clinical outcomes. Endod Topics 16 (2009) 1-26
-
(2009)
Endod Topics
, vol.16
, pp. 1-26
-
-
Cheung, G.S.P.1
-
14
-
-
43549102627
-
Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis
-
Kim H.C., Cheung G.S., Lee C.J., Kim B.M., Park J.K., and Kang S.I. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis. J Endod 34 (2008) 743-747
-
(2008)
J Endod
, vol.34
, pp. 743-747
-
-
Kim, H.C.1
Cheung, G.S.2
Lee, C.J.3
Kim, B.M.4
Park, J.K.5
Kang, S.I.6
-
15
-
-
47049088743
-
Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods
-
Gambarini G., Grande N.M., Plotino G., et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 34 (2008) 1003-1005
-
(2008)
J Endod
, vol.34
, pp. 1003-1005
-
-
Gambarini, G.1
Grande, N.M.2
Plotino, G.3
-
16
-
-
60649120454
-
Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments
-
Larsen C.M., Watanabe I., Glickman G.N., and He J. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod 35 (2009) 401-403
-
(2009)
J Endod
, vol.35
, pp. 401-403
-
-
Larsen, C.M.1
Watanabe, I.2
Glickman, G.N.3
He, J.4
-
17
-
-
0035656334
-
Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors
-
Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 27 (2001) 772-774
-
(2001)
J Endod
, vol.27
, pp. 772-774
-
-
Gambarini, G.1
-
18
-
-
0035432084
-
Influence of structure on nickel-titanium endodontic instruments failure
-
Kuhn G., Tavernier B., and Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endod 27 (2001) 516-520
-
(2001)
J Endod
, vol.27
, pp. 516-520
-
-
Kuhn, G.1
Tavernier, B.2
Jordan, L.3
-
19
-
-
33645070177
-
Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections
-
Xu X., Eng M., Zheng Y., and Eng D. Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections. J Endod 32 (2006) 372-375
-
(2006)
J Endod
, vol.32
, pp. 372-375
-
-
Xu, X.1
Eng, M.2
Zheng, Y.3
Eng, D.4
-
20
-
-
33644515982
-
Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
-
Yao J.H., Schwartz S.A., and Beeson T.J. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 32 (2006) 55-57
-
(2006)
J Endod
, vol.32
, pp. 55-57
-
-
Yao, J.H.1
Schwartz, S.A.2
Beeson, T.J.3
-
21
-
-
66749179992
-
Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals
-
Kim H.C., Kim H.J., Lee C.J., Kim B.M., Park J.K., and Versluis A. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. Int Endod J 42 (2009) 593-602
-
(2009)
Int Endod J
, vol.42
, pp. 593-602
-
-
Kim, H.C.1
Kim, H.J.2
Lee, C.J.3
Kim, B.M.4
Park, J.K.5
Versluis, A.6
-
22
-
-
33845405587
-
Cleaning and shaping of the root canal system
-
Cohen S., and Hargreaves K.M. (Eds), CV Mosby, St Louis
-
Peters O.A., and Peters C.I. Cleaning and shaping of the root canal system. In: Cohen S., and Hargreaves K.M. (Eds). Pathways of the pulp. 9th ed (2006), CV Mosby, St Louis 290-357
-
(2006)
Pathways of the pulp. 9th ed
, pp. 290-357
-
-
Peters, O.A.1
Peters, C.I.2
-
23
-
-
0035653584
-
Defects in GT rotary instruments after use: an SEM study
-
Tripi T.R., Bonaccorso A., Tripi V., Condorelli G.G., and Rapisarda E. Defects in GT rotary instruments after use: an SEM study. J Endod 27 (2001) 782-785
-
(2001)
J Endod
, vol.27
, pp. 782-785
-
-
Tripi, T.R.1
Bonaccorso, A.2
Tripi, V.3
Condorelli, G.G.4
Rapisarda, E.5
-
24
-
-
0036777233
-
Surface analysis of ProFile instruments by scanning election microscopy and X-ray energy dispersive spectroscopy: a preliminary study
-
Martins R.C., Bahia M.G., and Buono V.T. Surface analysis of ProFile instruments by scanning election microscopy and X-ray energy dispersive spectroscopy: a preliminary study. Int Endod J 35 (2002) 848-853
-
(2002)
Int Endod J
, vol.35
, pp. 848-853
-
-
Martins, R.C.1
Bahia, M.G.2
Buono, V.T.3
-
25
-
-
22544438540
-
Defects in ProTaper S1 instruments after clinical use: fractographic examination
-
Cheung G.S.P., Peng B., Bian Z., Shen Y., and Darvell B.W. Defects in ProTaper S1 instruments after clinical use: fractographic examination. Int Endod J 38 (2005) 802-809
-
(2005)
Int Endod J
, vol.38
, pp. 802-809
-
-
Cheung, G.S.P.1
Peng, B.2
Bian, Z.3
Shen, Y.4
Darvell, B.W.5
-
26
-
-
33646345401
-
Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments
-
Bahia M.G., Melo M.C., and Buono V.T. Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101 (2006) 675-680
-
(2006)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.101
, pp. 675-680
-
-
Bahia, M.G.1
Melo, M.C.2
Buono, V.T.3
-
29
-
-
0036777866
-
Fatigue and mechanical properties of nickel-titanium endodontic instruments
-
Kuhn G., and Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endod 28 (2002) 716-720
-
(2002)
J Endod
, vol.28
, pp. 716-720
-
-
Kuhn, G.1
Jordan, L.2
-
30
-
-
34547312762
-
Fatigue testing of a NiTi rotary instrument: part 2-fractographic analysis
-
Cheung G.S., and Darvell B.W. Fatigue testing of a NiTi rotary instrument: part 2-fractographic analysis. Int Endod J 40 (2007) 619-625
-
(2007)
Int Endod J
, vol.40
, pp. 619-625
-
-
Cheung, G.S.1
Darvell, B.W.2
-
31
-
-
19444362094
-
Understanding the surface features of fatigue fractures: how they describe the failure cause and the failure history
-
Sachs N.W. Understanding the surface features of fatigue fractures: how they describe the failure cause and the failure history. J Fail Anal Prev 5 (2005) 11-15
-
(2005)
J Fail Anal Prev
, vol.5
, pp. 11-15
-
-
Sachs, N.W.1
-
32
-
-
57649244370
-
Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis
-
Kim T.O., Cheung G.S.P., Lee J.M., Kim B.M., Hur B., and Kim H.C. Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis. Int Endod J 42 (2009) 14-21
-
(2009)
Int Endod J
, vol.42
, pp. 14-21
-
-
Kim, T.O.1
Cheung, G.S.P.2
Lee, J.M.3
Kim, B.M.4
Hur, B.5
Kim, H.C.6
-
33
-
-
12344257590
-
SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
-
Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31 (2005) 40-43
-
(2005)
J Endod
, vol.31
, pp. 40-43
-
-
Alapati, S.B.1
Brantley, W.A.2
Svec, T.A.3
Powers, J.M.4
Nusstein, J.M.5
Daehn, G.S.6
-
34
-
-
1542465898
-
Scanning electron microscope observation of new and used nickel-titanium rotary files
-
Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., and Mitchell J. Scanning electron microscope observation of new and used nickel-titanium rotary files. J Endod 29 (2003) 667-669
-
(2003)
J Endod
, vol.29
, pp. 667-669
-
-
Alapati, S.B.1
Brantley, W.A.2
Svec, T.A.3
Powers, J.M.4
Mitchell, J.5
-
35
-
-
34548537569
-
Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?
-
Cheung G.S., Shen Y., and Darvell B.W. Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?. J Endod 33 (2007) 1217-1221
-
(2007)
J Endod
, vol.33
, pp. 1217-1221
-
-
Cheung, G.S.1
Shen, Y.2
Darvell, B.W.3
-
36
-
-
0036431877
-
Effect of surface preparation on mechanical properties of a NiTi alloy
-
Miao W., Mi X., Zhu M., Guo J., and Kou Y. Effect of surface preparation on mechanical properties of a NiTi alloy. Mater Sci Forum 394-395 (2002) 173-176
-
(2002)
Mater Sci Forum
, vol.394-395
, pp. 173-176
-
-
Miao, W.1
Mi, X.2
Zhu, M.3
Guo, J.4
Kou, Y.5
-
37
-
-
0034146318
-
The effect of surface treatments of nickel titanium files on wear and cutting efficiency
-
Rapisarda E., Bonaccorso A., Tripi T.R., Fragalk I., and Condorelli G.G. The effect of surface treatments of nickel titanium files on wear and cutting efficiency. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89 (2000) 363-368
-
(2000)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.89
, pp. 363-368
-
-
Rapisarda, E.1
Bonaccorso, A.2
Tripi, T.R.3
Fragalk, I.4
Condorelli, G.G.5
-
38
-
-
34248181012
-
A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and Profile nickel titanium rotary files using an extracted molar tooth model
-
Herold K.S., Johnson B.R., and Wenckus C.S. A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and Profile nickel titanium rotary files using an extracted molar tooth model. J Endod 33 (2007) 712-714
-
(2007)
J Endod
, vol.33
, pp. 712-714
-
-
Herold, K.S.1
Johnson, B.R.2
Wenckus, C.S.3
-
39
-
-
33750025281
-
Surface integrity
-
Crookall J.R., Shaw M.C., and Suh N.P. (Eds), Oxford University Press, New York
-
Shaw M.C. Surface integrity. In: Crookall J.R., Shaw M.C., and Suh N.P. (Eds). Metal cutting principles. 2nd ed (2005), Oxford University Press, New York 472-478
-
(2005)
Metal cutting principles. 2nd ed
, pp. 472-478
-
-
Shaw, M.C.1
-
42
-
-
85164879076
-
-
Taylor & Francis Group, Boca Raton, FL
-
Hutchings M.T., Withers P.J., Holder T.M., and Lorentzen T. Introduction to the characterization of residual stress by neutron diffraction (2005), Taylor & Francis Group, Boca Raton, FL
-
(2005)
Introduction to the characterization of residual stress by neutron diffraction
-
-
Hutchings, M.T.1
Withers, P.J.2
Holder, T.M.3
Lorentzen, T.4
-
45
-
-
33645104462
-
Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments
-
Miyai K., Ebihara A., Hayashi Y., Doi H., Suda H., and Yoneyama T. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments. Int Endod J 39 (2006) 119-126
-
(2006)
Int Endod J
, vol.39
, pp. 119-126
-
-
Miyai, K.1
Ebihara, A.2
Hayashi, Y.3
Doi, H.4
Suda, H.5
Yoneyama, T.6
-
46
-
-
33947425205
-
Phase transformation behaviour and bending properties of hybrid nickel-titanium rotary endodontic instruments
-
Hayashi Y., Yoneyama T., Yahata Y., et al. Phase transformation behaviour and bending properties of hybrid nickel-titanium rotary endodontic instruments. Int Endod J 40 (2007) 247-253
-
(2007)
Int Endod J
, vol.40
, pp. 247-253
-
-
Hayashi, Y.1
Yoneyama, T.2
Yahata, Y.3
|