-
1
-
-
4143097917
-
Current challenges and concepts in the preparation of root canal systems: a review
-
Peters O.A. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30 (2004) 559-567
-
(2004)
J Endod
, vol.30
, pp. 559-567
-
-
Peters, O.A.1
-
2
-
-
3242766050
-
Real World Endo Sequence File
-
Koch K.A., and Brave D.G. Real World Endo Sequence File. Dent Clin North Am 48 (2004) 159-182
-
(2004)
Dent Clin North Am
, vol.48
, pp. 159-182
-
-
Koch, K.A.1
Brave, D.G.2
-
3
-
-
13744258851
-
The EndoSequence file: a guide to clinical use
-
Koch K., and Brave D. The EndoSequence file: a guide to clinical use. Compend Contin Educ Dent 25 (2004) 811-813
-
(2004)
Compend Contin Educ Dent
, vol.25
, pp. 811-813
-
-
Koch, K.1
Brave, D.2
-
4
-
-
0036480111
-
The deterioration of rotary nickel-titanium files under controlled conditions
-
Svec T.A., and Powers J.M. The deterioration of rotary nickel-titanium files under controlled conditions. J Endod 28 (2002) 105-107
-
(2002)
J Endod
, vol.28
, pp. 105-107
-
-
Svec, T.A.1
Powers, J.M.2
-
5
-
-
0030253003
-
Enhanced surface hardness by boron implantation in Nitinol alloy
-
Lee D.H., Park B., Saxena A., and Serene T.P. Enhanced surface hardness by boron implantation in Nitinol alloy. J Endod 22 (1996) 543-546
-
(1996)
J Endod
, vol.22
, pp. 543-546
-
-
Lee, D.H.1
Park, B.2
Saxena, A.3
Serene, T.P.4
-
6
-
-
0035458398
-
Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation
-
Rapisarda E., Bonaccorso A., Tripi T.R., Condorelli G.G., and Torrisi L. Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. J Endod 27 (2001) 588-592
-
(2001)
J Endod
, vol.27
, pp. 588-592
-
-
Rapisarda, E.1
Bonaccorso, A.2
Tripi, T.R.3
Condorelli, G.G.4
Torrisi, L.5
-
7
-
-
0034146318
-
The effect of surface treatments of nickel-titanium files on wear and cutting efficiency
-
Rapisarda E., Bonaccorso A., Tripi T.R., Fragalk I., and Condorelli G.G. The effect of surface treatments of nickel-titanium files on wear and cutting efficiency. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89 (2000) 363-368
-
(2000)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.89
, pp. 363-368
-
-
Rapisarda, E.1
Bonaccorso, A.2
Tripi, T.R.3
Fragalk, I.4
Condorelli, G.G.5
-
8
-
-
0035432084
-
Influence of structure on nickel-titanium endodontic instruments failure
-
Kuhn G., Tavernier B., and Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endod 27 (2001) 516-520
-
(2001)
J Endod
, vol.27
, pp. 516-520
-
-
Kuhn, G.1
Tavernier, B.2
Jordan, L.3
-
9
-
-
13544259558
-
The influence of a manual glide path on the separation rate of NiTi rotary instruments
-
Patino P.V., Biedma B.M., Liebana C.R., Cantatore G., and Bahillo J.G. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 31 (2005) 114-116
-
(2005)
J Endod
, vol.31
, pp. 114-116
-
-
Patino, P.V.1
Biedma, B.M.2
Liebana, C.R.3
Cantatore, G.4
Bahillo, J.G.5
-
10
-
-
0015109962
-
A comparison of canal preparations in straight and curved root canals
-
Schneider S.W. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 32 (1971) 271-275
-
(1971)
Oral Surg Oral Med Oral Pathol
, vol.32
, pp. 271-275
-
-
Schneider, S.W.1
-
11
-
-
14944376564
-
Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
-
Ullmann C.J., and Peters O.A. Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments. J Endod 31 (2005) 183-186
-
(2005)
J Endod
, vol.31
, pp. 183-186
-
-
Ullmann, C.J.1
Peters, O.A.2
-
12
-
-
0031064647
-
Cyclic fatigue testing of nickel-titanium endodontic instruments
-
Pruett J.P., Clement D.J., and Carnes Jr. D.L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23 (1997) 77-85
-
(1997)
J Endod
, vol.23
, pp. 77-85
-
-
Pruett, J.P.1
Clement, D.J.2
Carnes Jr., D.L.3
-
13
-
-
1542465898
-
Scanning electron microscope observations of new and used nickel-titanium rotary files
-
Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., and Mitchell J.C. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod 29 (2003) 667-669
-
(2003)
J Endod
, vol.29
, pp. 667-669
-
-
Alapati, S.B.1
Brantley, W.A.2
Svec, T.A.3
Powers, J.M.4
Mitchell, J.C.5
-
14
-
-
12344257590
-
SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
-
Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31 (2005) 40-43
-
(2005)
J Endod
, vol.31
, pp. 40-43
-
-
Alapati, S.B.1
Brantley, W.A.2
Svec, T.A.3
Powers, J.M.4
Nusstein, J.M.5
Daehn, G.S.6
-
15
-
-
0035221977
-
Influence of rotational speed, torque and operator's proficiency on ProFile failures
-
Yared G.M., Bou Dagher F.E., and Machtou P. Influence of rotational speed, torque and operator's proficiency on ProFile failures. Int Endod J 34 (2001) 47-53
-
(2001)
Int Endod J
, vol.34
, pp. 47-53
-
-
Yared, G.M.1
Bou Dagher, F.E.2
Machtou, P.3
-
16
-
-
0034139354
-
Effect of rotational speed on the breakage of nickel-titanium rotary files
-
Dietz D.B., Di Fiore P.M., Bahcall J.K., and Lautenschlager E.P. Effect of rotational speed on the breakage of nickel-titanium rotary files. J Endod 26 (2000) 68-71
-
(2000)
J Endod
, vol.26
, pp. 68-71
-
-
Dietz, D.B.1
Di Fiore, P.M.2
Bahcall, J.K.3
Lautenschlager, E.P.4
-
17
-
-
0042730176
-
Factors influencing the fracture of nickel-titanium rotary instruments
-
Martin B., Zelada G., Varela P., et al. Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J 36 (2003) 262-266
-
(2003)
Int Endod J
, vol.36
, pp. 262-266
-
-
Martin, B.1
Zelada, G.2
Varela, P.3
-
18
-
-
0033147312
-
Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
-
Haikel Y., Serfaty R., Bateman G., Senger B., and Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25 (1999) 434-440
-
(1999)
J Endod
, vol.25
, pp. 434-440
-
-
Haikel, Y.1
Serfaty, R.2
Bateman, G.3
Senger, B.4
Allemann, C.5
-
19
-
-
0036597338
-
Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests
-
Li U.M., Lee B.S., Shih C.T., Lan W.H., and Lin C.P. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 28 (2002) 448-451
-
(2002)
J Endod
, vol.28
, pp. 448-451
-
-
Li, U.M.1
Lee, B.S.2
Shih, C.T.3
Lan, W.H.4
Lin, C.P.5
-
20
-
-
33747122613
-
Nickel-titanium rotary instrument fracture: a clinical practice assessment
-
Di Fiore P.M., Genov K.A., Komaroff E., Li Y., and Lin L. Nickel-titanium rotary instrument fracture: a clinical practice assessment. Int Endod J 39 (2006) 700-708
-
(2006)
Int Endod J
, vol.39
, pp. 700-708
-
-
Di Fiore, P.M.1
Genov, K.A.2
Komaroff, E.3
Li, Y.4
Lin, L.5
-
21
-
-
5444247733
-
Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use
-
Parashos P., Gordon I., and Messer H.H. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. J Endod 30 (2004) 722-725
-
(2004)
J Endod
, vol.30
, pp. 722-725
-
-
Parashos, P.1
Gordon, I.2
Messer, H.H.3
|