메뉴 건너뛰기




Volumn 34, Issue 8, 2008, Pages 1003-1005

Fatigue Resistance of Engine-driven Rotary Nickel-Titanium Instruments Produced by New Manufacturing Methods

Author keywords

Cyclic fatigue; endodontic instruments; manufacturing process; nickel titanium

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 47049088743     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2008.05.007     Document Type: Article
Times cited : (281)

References (30)
  • 1
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of Nitinol root canal files
    • Walia H., Brantley W.A., and Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 14 (1988) 346-351
    • (1988) J Endod , vol.14 , pp. 346-351
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 2
    • 0034296268 scopus 로고    scopus 로고
    • A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests
    • Kazemi R.B., Stenman E., and Spångberg L.S. A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests. Oral Surg 90 (2000) 500-506
    • (2000) Oral Surg , vol.90 , pp. 500-506
    • Kazemi, R.B.1    Stenman, E.2    Spångberg, L.S.3
  • 3
    • 33645070177 scopus 로고    scopus 로고
    • Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections
    • Xu X., Eng M., Zheng Y., and Eng D. Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections. J Endod 32 (2006) 372-375
    • (2006) J Endod , vol.32 , pp. 372-375
    • Xu, X.1    Eng, M.2    Zheng, Y.3    Eng, D.4
  • 4
    • 34548524624 scopus 로고    scopus 로고
    • Fracture resistance of electropolished rotary nickel-titanium endodontic instruments
    • Anderson M.E., Price J.W., and Parashos P. Fracture resistance of electropolished rotary nickel-titanium endodontic instruments. J Endod 33 (2007) 1212-1216
    • (2007) J Endod , vol.33 , pp. 1212-1216
    • Anderson, M.E.1    Price, J.W.2    Parashos, P.3
  • 5
    • 33845320153 scopus 로고    scopus 로고
    • Separation incidence of protaper rotary instruments: a large cohort clinical evaluation
    • Wolcott S., Wolcott J., Ishley D., Kennedy W., Johnson S., Minnich S., and Meyers J. Separation incidence of protaper rotary instruments: a large cohort clinical evaluation. J Endod 32 (2006) 1139-1141
    • (2006) J Endod , vol.32 , pp. 1139-1141
    • Wolcott, S.1    Wolcott, J.2    Ishley, D.3    Kennedy, W.4    Johnson, S.5    Minnich, S.6    Meyers, J.7
  • 6
    • 33750008122 scopus 로고    scopus 로고
    • Rotary NiTi instrument fracture and its consequences
    • Parashos P., and Messer H.H. Rotary NiTi instrument fracture and its consequences. J Endod 32 (2006) 1031-1043
    • (2006) J Endod , vol.32 , pp. 1031-1043
    • Parashos, P.1    Messer, H.H.2
  • 7
    • 33749986991 scopus 로고    scopus 로고
    • A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study
    • Iqbal M.K., Kohli M.R., and Kim J.S. A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study. J Endod 32 (2006) 1048-1052
    • (2006) J Endod , vol.32 , pp. 1048-1052
    • Iqbal, M.K.1    Kohli, M.R.2    Kim, J.S.3
  • 8
    • 33847081737 scopus 로고    scopus 로고
    • Analysis of defects in ProTaper hand-operated instruments after clinical use
    • Shen Y., Bian Z., Cheung G.S., and Peng B. Analysis of defects in ProTaper hand-operated instruments after clinical use. J Endod 33 (2007) 287-290
    • (2007) J Endod , vol.33 , pp. 287-290
    • Shen, Y.1    Bian, Z.2    Cheung, G.S.3    Peng, B.4
  • 9
    • 33847064289 scopus 로고    scopus 로고
    • Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use
    • Wei X., Ling J., Jiang J., Huang X., and Liu L. Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use. J Endod 33 (2007) 276-279
    • (2007) J Endod , vol.33 , pp. 276-279
    • Wei, X.1    Ling, J.2    Jiang, J.3    Huang, X.4    Liu, L.5
  • 10
    • 0035656334 scopus 로고    scopus 로고
    • Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors
    • Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 27 (2001) 772-774
    • (2001) J Endod , vol.27 , pp. 772-774
    • Gambarini, G.1
  • 11
    • 36248982083 scopus 로고    scopus 로고
    • Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model
    • Ray J.J., Kirkpatrick T.C., and Rutledge R.E. Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model. J Endod 33 (2007) 1469-1472
    • (2007) J Endod , vol.33 , pp. 1469-1472
    • Ray, J.J.1    Kirkpatrick, T.C.2    Rutledge, R.E.3
  • 13
    • 33846189396 scopus 로고    scopus 로고
    • The effect of operational speed on the fracture of nickel-titanium rotary instruments
    • Kitchens Jr. G.G., Liewehr F.R., and Moon P.C. The effect of operational speed on the fracture of nickel-titanium rotary instruments. J Endod 33 (2007) 52-54
    • (2007) J Endod , vol.33 , pp. 52-54
    • Kitchens Jr., G.G.1    Liewehr, F.R.2    Moon, P.C.3
  • 14
    • 34147128188 scopus 로고    scopus 로고
    • Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments
    • Peters O.A., Roehlike J.O., and Baumann M.A. Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments. J Endod 33 (2007) 589-593
    • (2007) J Endod , vol.33 , pp. 589-593
    • Peters, O.A.1    Roehlike, J.O.2    Baumann, M.A.3
  • 15
    • 38349035870 scopus 로고    scopus 로고
    • Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency
    • Bui T.B., Mitchell J.C., and Baumgartner J.C. Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency. J Endod 34 (2008) 190-193
    • (2008) J Endod , vol.34 , pp. 190-193
    • Bui, T.B.1    Mitchell, J.C.2    Baumgartner, J.C.3
  • 16
    • 37249053931 scopus 로고    scopus 로고
    • Quantitative and qualitative elemental analysis of different nickel-titanium rotary instruments by using scanning electron microscopy and energy dispersive spectroscopy
    • Ounsi H.F., Al-Shalan T., Salameh Z., Grandini S., and Ferrari M. Quantitative and qualitative elemental analysis of different nickel-titanium rotary instruments by using scanning electron microscopy and energy dispersive spectroscopy. J Endod 34 (2008) 53-55
    • (2008) J Endod , vol.34 , pp. 53-55
    • Ounsi, H.F.1    Al-Shalan, T.2    Salameh, Z.3    Grandini, S.4    Ferrari, M.5
  • 17
    • 47049131016 scopus 로고    scopus 로고
    • Dentsply Tulsa Dental Specialties, Tulsa, OK
    • GT Seriex X Brochure (2008), Dentsply Tulsa Dental Specialties, Tulsa, OK
    • (2008) GT Seriex X Brochure
  • 19
    • 33747102691 scopus 로고    scopus 로고
    • A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments
    • Plotino G., Grande N.M., Sorci E., Malagnino V.A., and Somma F. A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments. Int Endod J 39 (2006) 716-723
    • (2006) Int Endod J , vol.39 , pp. 716-723
    • Plotino, G.1    Grande, N.M.2    Sorci, E.3    Malagnino, V.A.4    Somma, F.5
  • 20
    • 33748316675 scopus 로고    scopus 로고
    • Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems
    • Grande N.M., Plotino G., Pecci R., Bedini R., Malagnino V.A., and Somma F. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int Endod J 10 (2006) 755-763
    • (2006) Int Endod J , vol.10 , pp. 755-763
    • Grande, N.M.1    Plotino, G.2    Pecci, R.3    Bedini, R.4    Malagnino, V.A.5    Somma, F.6
  • 21
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel-titanium endodontic instruments
    • Pruett J.P., Clement D.J., and Carnes Jr. D.L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23 (1997) 77-85
    • (1997) J Endod , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes Jr., D.L.3
  • 22
    • 33748745197 scopus 로고    scopus 로고
    • Cyclic fatigue of different nickel-titanium rotary instruments
    • Tripi T.R., Bonaccorso A., and Condorelli G.G. Cyclic fatigue of different nickel-titanium rotary instruments. Oral Surg 102 (2006) 106-114
    • (2006) Oral Surg , vol.102 , pp. 106-114
    • Tripi, T.R.1    Bonaccorso, A.2    Condorelli, G.G.3
  • 23
    • 33644515982 scopus 로고    scopus 로고
    • Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
    • Yao J.H., Schwartz S.A., and Beeson T.J. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 32 (2006) 55-57
    • (2006) J Endod , vol.32 , pp. 55-57
    • Yao, J.H.1    Schwartz, S.A.2    Beeson, T.J.3
  • 24
    • 0036835346 scopus 로고    scopus 로고
    • Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments
    • Chaves Craveiro de Melo M., Bahia M.G.D.A., and Lopes Bueno V.T. Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments. J Endod 28 (2002) 765-769
    • (2002) J Endod , vol.28 , pp. 765-769
    • Chaves Craveiro de Melo, M.1    Bahia, M.G.D.A.2    Lopes Bueno, V.T.3
  • 25
    • 34547306412 scopus 로고    scopus 로고
    • Low cycle fatigue of NiTi rotary instruments of various cross-sectional shape
    • Cheung G.S.P., and Darvell B.W. Low cycle fatigue of NiTi rotary instruments of various cross-sectional shape. Int Endod J 40 (2007) 626-632
    • (2007) Int Endod J , vol.40 , pp. 626-632
    • Cheung, G.S.P.1    Darvell, B.W.2
  • 26
    • 33644515982 scopus 로고    scopus 로고
    • Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
    • Yao J.H., Schwartz S.A., and Beeson T.J. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 32 (2006) 55-57
    • (2006) J Endod , vol.32 , pp. 55-57
    • Yao, J.H.1    Schwartz, S.A.2    Beeson, T.J.3
  • 27
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel titanium endodontic instruments
    • Haikel Y., Serfaty R., Bateman G., Senger B., and Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allemann, C.5
  • 28
    • 33748745197 scopus 로고    scopus 로고
    • Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    • Tripi T.R., Bonaccorso A., and Condorelli G.G. Cyclic fatigue of different nickel-titanium endodontic rotary instruments. Oral Surg 102 (2006) e106-e114
    • (2006) Oral Surg , vol.102
    • Tripi, T.R.1    Bonaccorso, A.2    Condorelli, G.G.3
  • 29
    • 5444247733 scopus 로고    scopus 로고
    • Factors influencing defects of rotary nickel-titanium instruments after clinical use
    • Parashos P., Gordon I., and Messer H.H. Factors influencing defects of rotary nickel-titanium instruments after clinical use. J Endod 30 (2004) 722-725
    • (2004) J Endod , vol.30 , pp. 722-725
    • Parashos, P.1    Gordon, I.2    Messer, H.H.3
  • 30
    • 0035409020 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after prolonged clinical use
    • Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 34 (2001) 386-389
    • (2001) Int Endod J , vol.34 , pp. 386-389
    • Gambarini, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.