메뉴 건너뛰기




Volumn 38, Issue 11, 2005, Pages 802-809

Defects in ProTaper S1 instruments after clinical use: Fractographic examination

Author keywords

Fatigue; Fracture; Nickel titanium; Rotary instrument; Shear

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 22544438540     PISSN: 01432885     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2591.2005.01020.x     Document Type: Article
Times cited : (151)

References (37)
  • 1
    • 2442680167 scopus 로고    scopus 로고
    • K3 Endo, ProTaper, and ProFile systems: Breakage and distortion in severely curved root of molars
    • Ankrum MT, Hartwell GR, Truitt JE (2004) K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved root of molars. Journal of Endodontics 30, 234-7.
    • (2004) Journal of Endodontics , vol.30 , pp. 234-237
    • Ankrum, M.T.1    Hartwell, G.R.2    Truitt, J.E.3
  • 3
    • 27644522659 scopus 로고
    • Metals Park, OH, USA: The Materials Information Society
    • ASM International (1987) ASM Handbook, Vol. 12: Fractography. Metals Park, OH, USA: The Materials Information Society, pp. 12-165.
    • (1987) ASM Handbook, Vol. 12: Fractography , vol.12 , pp. 12-165
  • 4
    • 0038137043 scopus 로고    scopus 로고
    • Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile
    • Berutti E, Chiandussi G, Gaviglio I, Ibba A (2003) Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile. Journal of Endodontics 29, 15-9.
    • (2003) Journal of Endodontics , vol.29 , pp. 15-19
    • Berutti, E.1    Chiandussi, G.2    Gaviglio, I.3    Ibba, A.4
  • 5
    • 0032610007 scopus 로고    scopus 로고
    • Analysis of forces developed during mechanical preparation of extracted teeth using ProFile NiTi rotary instruments
    • Blum JY, Cohen A, Machtou P, Micallef JP (1999) Analysis of forces developed during mechanical preparation of extracted teeth using ProFile NiTi rotary instruments. International Endodontic Journal 32, 24-31.
    • (1999) International Endodontic Journal , vol.32 , pp. 24-31
    • Blum, J.Y.1    Cohen, A.2    Machtou, P.3    Micallef, J.P.4
  • 6
    • 0037026414 scopus 로고    scopus 로고
    • Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hank's solution
    • Cissé O, Savadogo O, Wu M, Yahia LH (2002) Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hank's solution. Journal of Biomedical Materials Research 61, 339-45.
    • (2002) Journal of Biomedical Materials Research , vol.61 , pp. 339-345
    • Cissé, O.1    Savadogo, O.2    Wu, M.3    Yahia, L.H.4
  • 8
    • 0035258163 scopus 로고    scopus 로고
    • Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm
    • Daugherty DW, Gound TG, Comer TL (2001) Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm. Journal of Endodontics 27, 93-5.
    • (2001) Journal of Endodontics , vol.27 , pp. 93-95
    • Daugherty, D.W.1    Gound, T.G.2    Comer, T.L.3
  • 11
    • 27644485787 scopus 로고    scopus 로고
    • FKG Dentaire (2005) Race NiTi instruments & SMD. http:// www.fkg.ch/pdf/FKG-Datasheet-Race-AN.pdf [accessed on 2 February 2005].
    • (2005) Race NiTi Instruments & SMD
  • 13
    • 0034208054 scopus 로고    scopus 로고
    • Rationale for the use of low-torque endodontic motors in root canal instrumentation
    • Gambarini G (2000) Rationale for the use of low-torque endodontic motors in root canal instrumentation. Endodontics and Dental Traumatology 16, 95-100.
    • (2000) Endodontics and Dental Traumatology , vol.16 , pp. 95-100
    • Gambarini, G.1
  • 14
    • 0035656334 scopus 로고    scopus 로고
    • Cyclic fatigue of nickel titanium rotary instruments after clinical use with low- and high-torque endodontic motors
    • Gambarini G (2001) Cyclic fatigue of nickel titanium rotary instruments after clinical use with low- and high-torque endodontic motors. Journal of Endodontics 27, 772-4.
    • (2001) Journal of Endodontics , vol.27 , pp. 772-774
    • Gambarini, G.1
  • 15
    • 0029264974 scopus 로고
    • A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments
    • Glosson CR, Haller RH, Dove SB, del Rio CE (1995) A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. Journal of Endodontics 21, 146-51.
    • (1995) Journal of Endodontics , vol.21 , pp. 146-151
    • Glosson, C.R.1    Haller, R.H.2    Dove, S.B.3    Del Rio, C.E.4
  • 16
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haïkel Y, Serfaty R, Bateman G, Senger B, Allemann C (1999) Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. Journal of Endodontics 25, 434-40.
    • (1999) Journal of Endodontics , vol.25 , pp. 434-440
    • Haïkel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allemann, C.5
  • 17
    • 0036431296 scopus 로고    scopus 로고
    • Effect of cold-working ratio on superelastic cyclic behaviour and fatigue life in Ti-41.7 Ni-8.5 Cu (at %) shape-memory alloy wire
    • Hosogi M, Okabe N, Sakuma T, Keiksuke O (2002) Effect of cold-working ratio on superelastic cyclic behaviour and fatigue life in Ti-41.7 Ni-8.5 Cu (at %) shape-memory alloy wire. Materials Science Forum 394-395, 257-60.
    • (2002) Materials Science Forum , vol.394-395 , pp. 257-260
    • Hosogi, M.1    Okabe, N.2    Sakuma, T.3    Keiksuke, O.4
  • 19
    • 0036777866 scopus 로고    scopus 로고
    • Fatigue and mechanical properties of nickel titanium endodontic instruments
    • Kuhn G, Jordan L (2002) Fatigue and mechanical properties of nickel titanium endodontic instruments. Journal of Endodontics 28, 716-20.
    • (2002) Journal of Endodontics , vol.28 , pp. 716-720
    • Kuhn, G.1    Jordan, L.2
  • 20
    • 0036597338 scopus 로고    scopus 로고
    • Cyclic fatigue of endodontic nickel titanium rotary instruments: Static and dynamic tests
    • Li UM, Lee BS, Shih CT, Lan WH, Lin CP (2002) Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. Journal of Endodontics 28, 448-51.
    • (2002) Journal of Endodontics , vol.28 , pp. 448-451
    • Li, U.M.1    Lee, B.S.2    Shih, C.T.3    Lan, W.H.4    Lin, C.P.5
  • 22
    • 0042730176 scopus 로고    scopus 로고
    • Factors influencing the fracture of nickel-titanium rotary instruments
    • Martín B, Zelada G, Varela P et al. (2003) Factors influencing the fracture of nickel-titanium rotary instruments. International Endodontic Journal 36, 262-6.
    • (2003) International Endodontic Journal , vol.36 , pp. 262-266
    • Martín, B.1    Zelada, G.2    Varela, P.3
  • 23
    • 0002383917 scopus 로고    scopus 로고
    • Mechanism of shape memory effect and superelasticity
    • Cambridge, UK: Cambridge University Press
    • Otsuka K, Wayman CM (eds) (1998) Mechanism of shape memory effect and superelasticity. In: Shape Memory Materials. Cambridge, UK: Cambridge University Press, pp. 27-48.
    • (1998) Shape Memory Materials , pp. 27-48
    • Otsuka, K.1    Wayman, C.M.2
  • 24
    • 5444247733 scopus 로고    scopus 로고
    • Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use
    • Parashos P, Gordon I, Messer HH (2004) Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. Journal of Endodontics 30, 722-5.
    • (2004) Journal of Endodontics , vol.30 , pp. 722-725
    • Parashos, P.1    Gordon, I.2    Messer, H.H.3
  • 25
    • 22544487199 scopus 로고    scopus 로고
    • Defects in ProTaper S1 instruments after clinical use: Longitudinal examination
    • Peng B, Shen Y, Cheung GSP, Xia TJ (2005) Defects in ProTaper S1 instruments after clinical use: longitudinal examination. International Endodontic Journal, 38, 550-7.
    • (2005) International Endodontic Journal , vol.38 , pp. 550-557
    • Peng, B.1    Shen, Y.2    Cheung, G.S.P.3    Xia, T.J.4
  • 26
  • 28
    • 0035458398 scopus 로고    scopus 로고
    • Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: Effect of ion implantation
    • Rapisarda E, Bonaccorso A, Tripi TR, Condorelli GG, Torrisi L (2001) Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. Journal of Endodontics 27, 588-92.
    • (2001) Journal of Endodontics , vol.27 , pp. 588-592
    • Rapisarda, E.1    Bonaccorso, A.2    Tripi, T.R.3    Condorelli, G.G.4    Torrisi, L.5
  • 30
    • 0002220515 scopus 로고    scopus 로고
    • Ti-Ni shape memory alloys
    • Otsuka K, Wayman CM, eds. Cambridge, UK: Cambridge University Press
    • Saburi T (1998) Ti-Ni shape memory alloys. In: Otsuka K, Wayman CM, eds. Shape Memory Materials. Cambridge, UK: Cambridge University Press, pp. 49-96.
    • (1998) Shape Memory Materials , pp. 49-96
    • Saburi, T.1
  • 33
    • 0031296835 scopus 로고    scopus 로고
    • Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    • Silvaggio J, Hicks ML (1997) Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files. Journal of Endodontics 23, 731-4.
    • (1997) Journal of Endodontics , vol.23 , pp. 731-734
    • Silvaggio, J.1    Hicks, M.L.2
  • 34
    • 0242636753 scopus 로고    scopus 로고
    • Root-canal shaping with manual and rotary Ni-Ti files performed by students
    • Sonntag D, Delschen S, Stachniss V (2003) Root-canal shaping with manual and rotary Ni-Ti files performed by students. International Endodontic Journal 36, 715-23.
    • (2003) International Endodontic Journal , vol.36 , pp. 715-723
    • Sonntag, D.1    Delschen, S.2    Stachniss, V.3
  • 35
    • 0035654496 scopus 로고    scopus 로고
    • Comparison of distortion and separation utilizing ProFile and Pow-R nickel-titanium rotary files
    • Tygesen YA, Steiman HR, Ciavarro C (2001) Comparison of distortion and separation utilizing ProFile and Pow-R nickel-titanium rotary files. Journal of Endodontics 27, 762-4.
    • (2001) Journal of Endodontics , vol.27 , pp. 762-764
    • Tygesen, Y.A.1    Steiman, H.R.2    Ciavarro, C.3
  • 36
    • 14944376564 scopus 로고    scopus 로고
    • Effect of cyclic fatigue on static fracture loads in ProTaper nickel titanium rotary instruments
    • Ullmann CJ, Peters OA (2005) Effect of cyclic fatigue on static fracture loads in ProTaper nickel titanium rotary instruments. Journal of Endodontics 31, 183-6.
    • (2005) Journal of Endodontics , vol.31 , pp. 183-186
    • Ullmann, C.J.1    Peters, O.A.2
  • 37
    • 0036597259 scopus 로고    scopus 로고
    • Failure of ProFile Ni-Ti instruments used by an inexperienced operator under access limitations
    • Yared GM, Kulkarni GK (2002) Failure of ProFile Ni-Ti instruments used by an inexperienced operator under access limitations. International Endodontic Journal 35, 536-41.
    • (2002) International Endodontic Journal , vol.35 , pp. 536-541
    • Yared, G.M.1    Kulkarni, G.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.