메뉴 건너뛰기




Volumn 35, Issue 11, 2009, Pages 1469-1476

A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments

Author keywords

Cyclic fatigue; fracture; nickel titanium; rotary instruments

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 70349968039     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2009.06.015     Document Type: Review
Times cited : (293)

References (56)
  • 1
    • 0034157078 scopus 로고    scopus 로고
    • Defects in rotary nickel-titanium files after clinical use
    • Sattapan B., Nervo G.J., Palamara J.E.A., et al. Defects in rotary nickel-titanium files after clinical use. J Endod 26 (2000) 161-165
    • (2000) J Endod , vol.26 , pp. 161-165
    • Sattapan, B.1    Nervo, G.J.2    Palamara, J.E.A.3
  • 3
    • 14944376564 scopus 로고    scopus 로고
    • Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
    • Ullmann C.J., and Peters O.A. Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments. J Endod 31 (2005) 183-186
    • (2005) J Endod , vol.31 , pp. 183-186
    • Ullmann, C.J.1    Peters, O.A.2
  • 4
    • 0042730176 scopus 로고    scopus 로고
    • Factors influencing the fracture of nickeltitanium rotary instruments
    • Martín B., Zelada G., Varela P., et al. Factors influencing the fracture of nickeltitanium rotary instruments. Int Endod J 36 (2003) 262-266
    • (2003) Int Endod J , vol.36 , pp. 262-266
    • Martín, B.1    Zelada, G.2    Varela, P.3
  • 5
    • 4143097917 scopus 로고    scopus 로고
    • Current challenges and concepts in the preparation of root canal systems: a review
    • Peters O.A. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30 (2004) 559-565
    • (2004) J Endod , vol.30 , pp. 559-565
    • Peters, O.A.1
  • 6
    • 5444247733 scopus 로고    scopus 로고
    • Factors influencing defects of rotary nickel titanium endodontic instruments after clinical use
    • Parashos P., Gordon I., and Messer H.H. Factors influencing defects of rotary nickel titanium endodontic instruments after clinical use. J Endod 30 (2004) 722-725
    • (2004) J Endod , vol.30 , pp. 722-725
    • Parashos, P.1    Gordon, I.2    Messer, H.H.3
  • 7
    • 22544487199 scopus 로고    scopus 로고
    • Defects in ProTaper S1 instruments after clinical use: longitudinal examination
    • Peng B., Shen Y., Cheung G.S.P., et al. Defects in ProTaper S1 instruments after clinical use: longitudinal examination. Int Endod J 38 (2005) 550-557
    • (2005) Int Endod J , vol.38 , pp. 550-557
    • Peng, B.1    Shen, Y.2    Cheung, G.S.P.3
  • 8
    • 22544438540 scopus 로고    scopus 로고
    • Defects in ProTaper S1 instruments after clinical use: fractographic examination
    • Cheung G.S., Peng B., Bian Z., et al. Defects in ProTaper S1 instruments after clinical use: fractographic examination. Int Endod J 38 (2005) 802-809
    • (2005) Int Endod J , vol.38 , pp. 802-809
    • Cheung, G.S.1    Peng, B.2    Bian, Z.3
  • 10
    • 12344257590 scopus 로고    scopus 로고
    • SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use
    • Alapati S.B., Brantley W.A., Svec T.A., et al. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use. J Endod 31 (2005) 40-43
    • (2005) J Endod , vol.31 , pp. 40-43
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3
  • 11
    • 70349922435 scopus 로고    scopus 로고
    • ANSI/ADA Specification N° 28-2002. Root canal files and reamers, type K for hand use. Chicago, IL: American Dental Association.
    • ANSI/ADA Specification N° 28-2002. Root canal files and reamers, type K for hand use. Chicago, IL: American Dental Association.
  • 12
    • 70349917115 scopus 로고    scopus 로고
    • Dentistry - Root canal instruments - Part 1: General requirements and test methods
    • ISO 3630-3631
    • ISO 3630-3631:2008. Dentistry - Root canal instruments - Part 1: General requirements and test methods.
    • (2008)
  • 13
    • 0022670883 scopus 로고
    • The effects of cyclical axial motion on rotary endodontic instrument fatigue
    • Dederich D.N., and Zakariasen K.L. The effects of cyclical axial motion on rotary endodontic instrument fatigue. Oral Surg Oral Med Oral Pathol 61 (1986) 192-196
    • (1986) Oral Surg Oral Med Oral Pathol , vol.61 , pp. 192-196
    • Dederich, D.N.1    Zakariasen, K.L.2
  • 14
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel titanium endodontic instruments
    • Pruett J.P., Clement D.J., and Carnes D.L. Cyclic fatigue testing of nickel titanium endodontic instruments. J Endod 23 (1997) 77-85
    • (1997) J Endod , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes, D.L.3
  • 15
    • 0015109962 scopus 로고
    • A comparison of canal preparations in straight and curved root canals
    • Schneider S.W. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 32 (1971) 271-275
    • (1971) Oral Surg Oral Med Oral Pathol , vol.32 , pp. 271-275
    • Schneider, S.W.1
  • 16
    • 34548524624 scopus 로고    scopus 로고
    • Fracture resistance of electropolished rotary nickel-titanium endodontic instruments
    • Anderson M.E., Price J.W.H., and Parashos P. Fracture resistance of electropolished rotary nickel-titanium endodontic instruments. J Endod 33 (2007) 1212-1216
    • (2007) J Endod , vol.33 , pp. 1212-1216
    • Anderson, M.E.1    Price, J.W.H.2    Parashos, P.3
  • 17
    • 36248991299 scopus 로고    scopus 로고
    • Influence of previous angular deformation on flexural fatigue resistance of K3 nickel-titanium rotary instruments
    • Barbosa F.O.G., Gomes J.A., and de Araujo M.C.P. Influence of previous angular deformation on flexural fatigue resistance of K3 nickel-titanium rotary instruments. J Endod 33 (2007) 1477-1480
    • (2007) J Endod , vol.33 , pp. 1477-1480
    • Barbosa, F.O.G.1    Gomes, J.A.2    de Araujo, M.C.P.3
  • 18
    • 0032241088 scopus 로고    scopus 로고
    • Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    • Mize S.B., Clement D.J., Pruett J.P., et al. Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 24 (1998) 843-847
    • (1998) J Endod , vol.24 , pp. 843-847
    • Mize, S.B.1    Clement, D.J.2    Pruett, J.P.3
  • 19
    • 0033090305 scopus 로고    scopus 로고
    • Cyclic fatigue of Profile rotary instruments after simulated clinical use
    • Yared G.M., Bou Dagher F.E., and Machtou P. Cyclic fatigue of Profile rotary instruments after simulated clinical use. Int Endod J 32 (1999) 115-119
    • (1999) Int Endod J , vol.32 , pp. 115-119
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3
  • 20
    • 0034189130 scopus 로고    scopus 로고
    • Cyclic fatigue of Profile rotary instruments after clinical use
    • Yared G.M., Bou Dagher F.E., and Machtou P. Cyclic fatigue of Profile rotary instruments after clinical use. Int Endod J 33 (2000) 204-207
    • (2000) Int Endod J , vol.33 , pp. 204-207
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3
  • 21
    • 0036835346 scopus 로고    scopus 로고
    • Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments
    • Melo M.C., Bahia M.G.A., and Buono V.T.L. Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments. J Endod 28 (2002) 765-769
    • (2002) J Endod , vol.28 , pp. 765-769
    • Melo, M.C.1    Bahia, M.G.A.2    Buono, V.T.L.3
  • 22
    • 33644515982 scopus 로고    scopus 로고
    • Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
    • Yao J.H., Schwartz S.A., and Beeson T.J. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 32 (2006) 55-57
    • (2006) J Endod , vol.32 , pp. 55-57
    • Yao, J.H.1    Schwartz, S.A.2    Beeson, T.J.3
  • 23
    • 33846251939 scopus 로고    scopus 로고
    • Cyclic fatigue of Protaper instruments
    • Lopes H.P., Moreira E.J.L., Elias C.N., et al. Cyclic fatigue of Protaper instruments. J Endod 33 (2007) 55-57
    • (2007) J Endod , vol.33 , pp. 55-57
    • Lopes, H.P.1    Moreira, E.J.L.2    Elias, C.N.3
  • 24
    • 38349035870 scopus 로고    scopus 로고
    • Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency
    • Bui T.B., Mitchell J.C., and Baumgartner J.C. Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency. J Endod 34 (2008) 190-193
    • (2008) J Endod , vol.34 , pp. 190-193
    • Bui, T.B.1    Mitchell, J.C.2    Baumgartner, J.C.3
  • 25
    • 60649083184 scopus 로고    scopus 로고
    • An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files
    • Kramkowski T.R., and Bahcall J. An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files. J Endod 35 (2009) 404-407
    • (2009) J Endod , vol.35 , pp. 404-407
    • Kramkowski, T.R.1    Bahcall, J.2
  • 26
    • 22544455071 scopus 로고    scopus 로고
    • Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals
    • Bahia M., and Buono V. Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 100 (2005) 249-255
    • (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.100 , pp. 249-255
    • Bahia, M.1    Buono, V.2
  • 27
    • 34248163857 scopus 로고    scopus 로고
    • Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments
    • Ounsi H.F., Salameh Z., Al-Shalan T., et al. Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments. J Endod 33 (2007) 737-741
    • (2007) J Endod , vol.33 , pp. 737-741
    • Ounsi, H.F.1    Salameh, Z.2    Al-Shalan, T.3
  • 28
    • 0036597338 scopus 로고    scopus 로고
    • Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests
    • Li U.M., Lee B.S., Shih C.T., et al. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 28 (2002) 448-451
    • (2002) J Endod , vol.28 , pp. 448-451
    • Li, U.M.1    Lee, B.S.2    Shih, C.T.3
  • 29
    • 33748946592 scopus 로고    scopus 로고
    • Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments
    • Li U.M., Lee B.S., Shin C.S., et al. Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. Dent Mater J 25 (2006) 247-252
    • (2006) Dent Mater J , vol.25 , pp. 247-252
    • Li, U.M.1    Lee, B.S.2    Shin, C.S.3
  • 30
    • 33846189396 scopus 로고    scopus 로고
    • The effect of operational speed on the fracture of nickel-titanium rotary instruments
    • Kitchens G.G., Liewehr F.R., and Moon P.C. The effect of operational speed on the fracture of nickel-titanium rotary instruments. J Endod 33 (2007) 52-54
    • (2007) J Endod , vol.33 , pp. 52-54
    • Kitchens, G.G.1    Liewehr, F.R.2    Moon, P.C.3
  • 31
    • 36248982083 scopus 로고    scopus 로고
    • Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model
    • Ray J.J., Kirkpatrick T.C., and Rutledge R.E. Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model. J Endod 33 (2007) 1469-1472
    • (2007) J Endod , vol.33 , pp. 1469-1472
    • Ray, J.J.1    Kirkpatrick, T.C.2    Rutledge, R.E.3
  • 34
    • 34547306412 scopus 로고    scopus 로고
    • Low-cycle fatigue of NiTi rotary instruments of various cross-sectional shapes
    • Cheung G.S., and Darvell B.W. Low-cycle fatigue of NiTi rotary instruments of various cross-sectional shapes. Int Endod J 40 (2007) 626-632
    • (2007) Int Endod J , vol.40 , pp. 626-632
    • Cheung, G.S.1    Darvell, B.W.2
  • 35
    • 34548537569 scopus 로고    scopus 로고
    • Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?
    • Cheung G.S., Shen Y., and Darvell B.W. Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?. J Endod 33 (2007) 1217-1221
    • (2007) J Endod , vol.33 , pp. 1217-1221
    • Cheung, G.S.1    Shen, Y.2    Darvell, B.W.3
  • 36
    • 36248943047 scopus 로고    scopus 로고
    • Effect of environment on low-cycle fatigue of a nickel-titanium instrument
    • Cheung G.S., Shen Y., and Darvell B.W. Effect of environment on low-cycle fatigue of a nickel-titanium instrument. J Endod 33 (2007) 1433-1437
    • (2007) J Endod , vol.33 , pp. 1433-1437
    • Cheung, G.S.1    Shen, Y.2    Darvell, B.W.3
  • 39
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel titanium endodontic instruments
    • Haikel Y., Serfaty R., Bateman G., et al. Dynamic and cyclic fatigue of engine-driven rotary nickel titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3
  • 40
    • 0035409020 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after prolonged clinical use
    • Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 34 (2001) 386-389
    • (2001) Int Endod J , vol.34 , pp. 386-389
    • Gambarini, G.1
  • 41
    • 0035656334 scopus 로고    scopus 로고
    • Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low-and high-torque endodontic motors
    • Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low-and high-torque endodontic motors. J Endod 27 (2001) 772-774
    • (2001) J Endod , vol.27 , pp. 772-774
    • Gambarini, G.1
  • 43
    • 33747144201 scopus 로고    scopus 로고
    • Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments
    • Berutti E., Angelini E., Rigolone M., et al. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. Int Endod J 39 (2006) 693-699
    • (2006) Int Endod J , vol.39 , pp. 693-699
    • Berutti, E.1    Angelini, E.2    Rigolone, M.3
  • 44
    • 33748746918 scopus 로고    scopus 로고
    • The effect of sodium hypochlorite on the surface characteristics and fatigue resistance of ProFile nickel-titanium instruments
    • de Castro Martins R., Bahia M.G., Buono V.T., et al. The effect of sodium hypochlorite on the surface characteristics and fatigue resistance of ProFile nickel-titanium instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102 (2006) e99-105
    • (2006) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.102
    • de Castro Martins, R.1    Bahia, M.G.2    Buono, V.T.3
  • 46
    • 33747132889 scopus 로고    scopus 로고
    • Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments
    • Viana A.C., Gonzalez B.M., Buono V.T., et al. Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments. Int Endod J 39 (2006) 709-715
    • (2006) Int Endod J , vol.39 , pp. 709-715
    • Viana, A.C.1    Gonzalez, B.M.2    Buono, V.T.3
  • 47
    • 36148956236 scopus 로고    scopus 로고
    • Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature
    • Inan U., Aydin C., and Tunca Y.M. Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104 (2007) 837-840
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.104 , pp. 837-840
    • Inan, U.1    Aydin, C.2    Tunca, Y.M.3
  • 48
    • 38149007720 scopus 로고    scopus 로고
    • Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments
    • Vieira E.P., França E.C., Martins R.C., et al. Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments. Int Endod J 41 (2008) 163-172
    • (2008) Int Endod J , vol.41 , pp. 163-172
    • Vieira, E.P.1    França, E.C.2    Martins, R.C.3
  • 49
    • 34147128188 scopus 로고    scopus 로고
    • Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments
    • Peters O.A., Roehlike J.O., and Baumann M.A. Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments. J Endod 33 (2007) 589-593
    • (2007) J Endod , vol.33 , pp. 589-593
    • Peters, O.A.1    Roehlike, J.O.2    Baumann, M.A.3
  • 50
    • 53349161910 scopus 로고    scopus 로고
    • Comparison between a novel nickel-titanium Alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments
    • Johnson E., Lloyd A., Kuttler S., et al. Comparison between a novel nickel-titanium Alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments. J Endod 34 (2008) 1406-1409
    • (2008) J Endod , vol.34 , pp. 1406-1409
    • Johnson, E.1    Lloyd, A.2    Kuttler, S.3
  • 51
    • 60649120454 scopus 로고    scopus 로고
    • Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments
    • Larsen C.M., Watanabe I., Glickman G.N., et al. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod 35 (2009) 401-403
    • (2009) J Endod , vol.35 , pp. 401-403
    • Larsen, C.M.1    Watanabe, I.2    Glickman, G.N.3
  • 52
    • 33747102691 scopus 로고    scopus 로고
    • A comparison of cyclic fatigue between used and new Mtwo NiTi rotary instruments
    • Plotino G., Grande N.M., Sorci E., et al. A comparison of cyclic fatigue between used and new Mtwo NiTi rotary instruments. Int Endod J 39 (2006) 716-723
    • (2006) Int Endod J , vol.39 , pp. 716-723
    • Plotino, G.1    Grande, N.M.2    Sorci, E.3
  • 53
    • 33748316675 scopus 로고    scopus 로고
    • Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems
    • Grande N.M., Plotino G., Pecci R., et al. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int Endod J 39 (2006) 755-763
    • (2006) Int Endod J , vol.39 , pp. 755-763
    • Grande, N.M.1    Plotino, G.2    Pecci, R.3
  • 54
    • 33845760979 scopus 로고    scopus 로고
    • Influence of a brushing working motion on the fatigue life of NiTi rotary instruments
    • Plotino G., Grande N.M., Sorci E., et al. Influence of a brushing working motion on the fatigue life of NiTi rotary instruments. Int Endod J 40 (2007) 45-51
    • (2007) Int Endod J , vol.40 , pp. 45-51
    • Plotino, G.1    Grande, N.M.2    Sorci, E.3
  • 55
    • 47049088743 scopus 로고    scopus 로고
    • Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods
    • Gambarini G., Grande N.M., Plotino G., et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 34 (2008) 1003-1005
    • (2008) J Endod , vol.34 , pp. 1003-1005
    • Gambarini, G.1    Grande, N.M.2    Plotino, G.3
  • 56
    • 69049116154 scopus 로고    scopus 로고
    • Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests
    • Plotino G., Grande N.M., Testarelli L., et al. Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108 3 (2009 Sep) e152-e156
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.108 , Issue.3
    • Plotino, G.1    Grande, N.M.2    Testarelli, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.