메뉴 건너뛰기




Volumn 33, Issue 1, 2007, Pages 52-54

The Effect of Operational Speed on the Fracture of Nickel-Titanium Rotary Instruments

Author keywords

Fracture; rotary; speed

Indexed keywords

NICKEL; TITANIUM; TITANIUM NICKELIDE; UNCLASSIFIED DRUG;

EID: 33846189396     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2006.09.004     Document Type: Article
Times cited : (40)

References (15)
  • 1
    • 0016662355 scopus 로고
    • Potential applications of certain nickel-titanium (Nitinol) alloys
    • Civjan S., Huget E.F., and DeSimon L.B. Potential applications of certain nickel-titanium (Nitinol) alloys. J Dent Res 54 (1975) 89-96
    • (1975) J Dent Res , vol.54 , pp. 89-96
    • Civjan, S.1    Huget, E.F.2    DeSimon, L.B.3
  • 2
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia H., Brantley W.A., and Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14 (1988) 346-351
    • (1988) J Endod , vol.14 , pp. 346-351
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 3
    • 0029264974 scopus 로고
    • A comparison of root canals preparations using Ni-Ti hand, Ni-Ti engine driven, and K-Flex endodontic instruments
    • Glosson C.R., Haller R.H., Dove S.B., and del Rio C.E. A comparison of root canals preparations using Ni-Ti hand, Ni-Ti engine driven, and K-Flex endodontic instruments. J Endod 21 (1995) 146-151
    • (1995) J Endod , vol.21 , pp. 146-151
    • Glosson, C.R.1    Haller, R.H.2    Dove, S.B.3    del Rio, C.E.4
  • 4
    • 77049220185 scopus 로고
    • Microscopic investigation of the root apexes
    • Kuttler Y. Microscopic investigation of the root apexes. J Am Dent Assoc 50 (1955) 544-552
    • (1955) J Am Dent Assoc , vol.50 , pp. 544-552
    • Kuttler, Y.1
  • 5
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haikel Y., Serfaty R., Bateman G., Senger B., and Allenmann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allenmann, C.5
  • 6
    • 0034157078 scopus 로고    scopus 로고
    • Defects in rotary nickel titanium file after clinical use
    • Sattapan B., Nervo G., Palamara J., and Messer H. Defects in rotary nickel titanium file after clinical use. J Endod 26 (2000) 161-165
    • (2000) J Endod , vol.26 , pp. 161-165
    • Sattapan, B.1    Nervo, G.2    Palamara, J.3    Messer, H.4
  • 7
    • 33846194515 scopus 로고    scopus 로고
    • Kelly SM. Fatigue. Web document. Virginia Tech, 1997. http://www.sv.vt.edu/classes/MSE2094_NoteBook/97ClassProj/anal/kelly/fatigue.html . Accessed August 25, 2006.
  • 8
    • 0036597338 scopus 로고    scopus 로고
    • Cyclic fatigue of endodontic nickel-titanium rotary instruments: static and dynamic tests
    • Li U., Lee B., Shih C., Lan W., and Lin C. Cyclic fatigue of endodontic nickel-titanium rotary instruments: static and dynamic tests. J Endod 28 (2002) 448-451
    • (2002) J Endod , vol.28 , pp. 448-451
    • Li, U.1    Lee, B.2    Shih, C.3    Lan, W.4    Lin, C.5
  • 9
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel-titanium endodontic instruments
    • Pruett J.P., Clement D.J., and Carnes D.L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23 (1997) 77-85
    • (1997) J Endod , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes, D.L.3
  • 10
    • 0015109962 scopus 로고
    • A comparison of canal preparation in straight and curved root canals
    • Schneider S.W. A comparison of canal preparation in straight and curved root canals. Oral Surg 32 (1971) 271-275
    • (1971) Oral Surg , vol.32 , pp. 271-275
    • Schneider, S.W.1
  • 11
    • 33644515982 scopus 로고    scopus 로고
    • Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model
    • Yao J.H., Schwartz S.A., and Beeson T.J. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 32 (2006) 55-57
    • (2006) J Endod , vol.32 , pp. 55-57
    • Yao, J.H.1    Schwartz, S.A.2    Beeson, T.J.3
  • 12
    • 0022670883 scopus 로고
    • The effects of cyclical axial motion on rotary endodontic instrument fatigue
    • Dederich D.N., and Zakariasen K.L. The effects of cyclical axial motion on rotary endodontic instrument fatigue. Oral Surg 61 (1986) 192-196
    • (1986) Oral Surg , vol.61 , pp. 192-196
    • Dederich, D.N.1    Zakariasen, K.L.2
  • 13
    • 20444489249 scopus 로고    scopus 로고
    • A comparison of torque required to fracture rotary files with tips bound in simulated curved canal
    • Guilford W.L., Lemons J.E., and Eleazer P.D. A comparison of torque required to fracture rotary files with tips bound in simulated curved canal. J Endod 31 (2005) 468-470
    • (2005) J Endod , vol.31 , pp. 468-470
    • Guilford, W.L.1    Lemons, J.E.2    Eleazer, P.D.3
  • 15
    • 0035258163 scopus 로고    scopus 로고
    • Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm
    • Daugherty D.W., Gound T.G., and Comer T.L. Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm. J Endod 27 (2001) 93-95
    • (2001) J Endod , vol.27 , pp. 93-95
    • Daugherty, D.W.1    Gound, T.G.2    Comer, T.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.