메뉴 건너뛰기




Volumn 30, Issue 10, 2004, Pages 722-725

Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use

Author keywords

[No Author keywords available]

Indexed keywords

NICKEL; TITANIUM;

EID: 5444247733     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.DON.0000129963.42882.C9     Document Type: Article
Times cited : (246)

References (19)
  • 1
    • 0034189130 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after clinical use
    • Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of ProFile rotary instruments after clinical use. Int Endod J 2000;33:204-7.
    • (2000) Int Endod J , vol.33 , pp. 204-207
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3
  • 2
    • 0035409020 scopus 로고    scopus 로고
    • Cyclic fatigue of ProFile rotary instruments after prolonged clinical use
    • Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 2001;34:386-9.
    • (2001) Int Endod J , vol.34 , pp. 386-389
    • Gambarini, G.1
  • 3
    • 0036777866 scopus 로고    scopus 로고
    • Fatigue and mechanical properties of nickel-titanium endodontic instruments
    • Kuhn G, Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endodon 2002;28:716-20.
    • (2002) J Endodon , vol.28 , pp. 716-720
    • Kuhn, G.1    Jordan, L.2
  • 4
    • 0036528158 scopus 로고    scopus 로고
    • Dynamic torque and apical forces of ProFile 04 rotary instruments during preparation of curved canals
    • Peters OA, Barbakow F. Dynamic torque and apical forces of ProFile 04 rotary instruments during preparation of curved canals. Int Endod J 2002;35:379-89.
    • (2002) Int Endod J , vol.35 , pp. 379-389
    • Peters, O.A.1    Barbakow, F.2
  • 5
    • 0036635798 scopus 로고    scopus 로고
    • The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments
    • Zelada G, Varela P, Martin B, Bahíllo JG, Magán F, Ahn S. The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. J Endodon 2002;28:540-2.
    • (2002) J Endodon , vol.28 , pp. 540-542
    • Zelada, G.1    Varela, P.2    Martin, B.3    Bahíllo, J.G.4    Magán, F.5    Ahn, S.6
  • 6
    • 1542465898 scopus 로고    scopus 로고
    • Scanning electron microscope observations of new and used nickel-titanium rotary files
    • Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endodon 2003;29:667-9.
    • (2003) J Endodon , vol.29 , pp. 667-669
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Mitchell, J.C.5
  • 7
    • 1542570495 scopus 로고    scopus 로고
    • Evaluation of single-use rotary nickel-titanium instruments
    • Arens FC, Hoen MM, Steiman HR, Dietz GC. Jr. Evaluation of single-use rotary nickel-titanium instruments. J Endodon 2003;29:664-6.
    • (2003) J Endodon , vol.29 , pp. 664-666
    • Arens, F.C.1    Hoen, M.M.2    Steiman, H.R.3    Dietz Jr., G.C.4
  • 9
    • 0038146983 scopus 로고    scopus 로고
    • ProTaper rotary root canal preparation: Assessment of torque and force in relation to canal anatomy
    • Peters OA, Peters CI, Schonenberger K, Barbakow F. ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy. Int Endod J 2003;36:93-9.
    • (2003) Int Endod J , vol.36 , pp. 93-99
    • Peters, O.A.1    Peters, C.I.2    Schonenberger, K.3    Barbakow, F.4
  • 11
    • 0347416962 scopus 로고    scopus 로고
    • Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo
    • Al-Fouzan KS. Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo. Int Endod J 2003;36:864-7.
    • (2003) Int Endod J , vol.36 , pp. 864-867
    • Al-Fouzan, K.S.1
  • 13
    • 0036366281 scopus 로고    scopus 로고
    • Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files
    • Yared GM, Bou Dagher FE, Machtou P, Kulkarni GK. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. Int Endod J 2002;35:7-12.
    • (2002) Int Endod J , vol.35 , pp. 7-12
    • Yared, G.M.1    Bou Dagher, F.E.2    Machtou, P.3    Kulkarni, G.K.4
  • 14
    • 0242636753 scopus 로고    scopus 로고
    • Root-canal shaping with manual and rotary Ni-Ti files performed by students
    • Sonntag D, Delschen S, Stachniss V. Root-canal shaping with manual and rotary Ni-Ti files performed by students. Int Endod J 2003;36:715-23.
    • (2003) Int Endod J , vol.36 , pp. 715-723
    • Sonntag, D.1    Delschen, S.2    Stachniss, V.3
  • 15
    • 0033222799 scopus 로고    scopus 로고
    • Effect of rotational speed on nickel-titanium file distortion
    • Gabel WP, Hoen M, Steiman HR, Pink FE, Dietz R. Effect of rotational speed on nickel-titanium file distortion. J Endodon 1999;25:752-4.
    • (1999) J Endodon , vol.25 , pp. 752-754
    • Gabel, W.P.1    Hoen, M.2    Steiman, H.R.3    Pink, F.E.4    Dietz, R.5
  • 16
    • 1542786387 scopus 로고    scopus 로고
    • Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: An experimental study
    • Ward JR, Parashos P, Messer HH. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study. J Endodon 2003;29:756-63.
    • (2003) J Endodon , vol.29 , pp. 756-763
    • Ward, J.R.1    Parashos, P.2    Messer, H.H.3
  • 17
    • 1542786390 scopus 로고    scopus 로고
    • Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: Clinical cases
    • Ward JR, Parashos P, Messer HH. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases. J Endodon 2003;29:764-7.
    • (2003) J Endodon , vol.29 , pp. 764-767
    • Ward, J.R.1    Parashos, P.2    Messer, H.H.3
  • 18
    • 0036632661 scopus 로고    scopus 로고
    • The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments
    • Roland DD, Andelin WE, Browning DF, Hsu G-HR, Torabinejad M. The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. J Endodon 2002;28:543-5.
    • (2002) J Endodon , vol.28 , pp. 543-545
    • Roland, D.D.1    Andelin, W.E.2    Browning, D.F.3    Hsu, G.-H.R.4    Torabinejad, M.5
  • 19
    • 0036480111 scopus 로고    scopus 로고
    • The deterioration of rotary nickel-titanium files under controlled conditions
    • Svec TA, Powers JM. The deterioration of rotary nickel-titanium files under controlled conditions. J Endodon 2002;28:105-7.
    • (2002) J Endodon , vol.28 , pp. 105-107
    • Svec, T.A.1    Powers, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.