메뉴 건너뛰기




Volumn 33, Issue 5, 2007, Pages 589-593

Effect of Immersion in Sodium Hypochlorite on Torque and Fatigue Resistance of Nickel-Titanium Instruments

Author keywords

Corrosion; fatigue; nickel titanium; sodium hypochlorite; torque

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; HYPOCHLORITE SODIUM; NICKEL; TITANIUM; TITANIUM NICKELIDE; UNCLASSIFIED DRUG;

EID: 34147128188     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2007.01.007     Document Type: Article
Times cited : (78)

References (30)
  • 1
    • 34147176770 scopus 로고    scopus 로고
    • Eradication of endodontic infection by instrumentation and irrigation solutions
    • Haapasalo M., Endal U., Zandi H., and Coil J.M. Eradication of endodontic infection by instrumentation and irrigation solutions. Endodontic Topics 10 (2005) 77-102
    • (2005) Endodontic Topics , vol.10 , pp. 77-102
    • Haapasalo, M.1    Endal, U.2    Zandi, H.3    Coil, J.M.4
  • 2
    • 33744977214 scopus 로고    scopus 로고
    • Root canal irrigants
    • Zehnder M. Root canal irrigants. J Endod 32 (2006) 389-398
    • (2006) J Endod , vol.32 , pp. 389-398
    • Zehnder, M.1
  • 3
    • 0015745863 scopus 로고
    • Biologic effects of dental materials. 3. Toxicity and antimicrobial effect of endodontic antiseptics in vitro
    • Spångberg L., Engström B., and Langeland K. Biologic effects of dental materials. 3. Toxicity and antimicrobial effect of endodontic antiseptics in vitro. Oral Surg Oral Med Oral Pathol 36 (1973) 856-871
    • (1973) Oral Surg Oral Med Oral Pathol , vol.36 , pp. 856-871
    • Spångberg, L.1    Engström, B.2    Langeland, K.3
  • 4
    • 33749533463 scopus 로고    scopus 로고
    • Dissolution of porcine incisor pulps in sodium hypochlorite solutions of varying compositions and concentrations
    • Clarkson R.M., Moule A.J., Podlich H., et al. Dissolution of porcine incisor pulps in sodium hypochlorite solutions of varying compositions and concentrations. Aust Dent J 51 (2006) 245-251
    • (2006) Aust Dent J , vol.51 , pp. 245-251
    • Clarkson, R.M.1    Moule, A.J.2    Podlich, H.3
  • 5
    • 0346977869 scopus 로고    scopus 로고
    • Some factors affecting the concentration of available chlorine in commercial sources of sodium hypochlorite
    • Frais S., Ng Y.L., and Gulabivala K. Some factors affecting the concentration of available chlorine in commercial sources of sodium hypochlorite. Int Endod J 34 (2001) 206-215
    • (2001) Int Endod J , vol.34 , pp. 206-215
    • Frais, S.1    Ng, Y.L.2    Gulabivala, K.3
  • 6
    • 0141902992 scopus 로고    scopus 로고
    • Cleaning and shaping the root canal system
    • Cohen S., and Burns R.C. (Eds), Mosby, St. Louis MO
    • Ruddle C. Cleaning and shaping the root canal system. In: Cohen S., and Burns R.C. (Eds). Pathways of the Pulp. 8th ed (2002), Mosby, St. Louis MO 231-292
    • (2002) Pathways of the Pulp. 8th ed , pp. 231-292
    • Ruddle, C.1
  • 7
    • 0020741583 scopus 로고
    • A scanning electron microscopic comparison of a high volume final flush with several irrigating solutions: Part 3
    • Yamada R.S., Armas A., Goldman M., and Lin P.S. A scanning electron microscopic comparison of a high volume final flush with several irrigating solutions: Part 3. J Endod 9 (1983) 137-142
    • (1983) J Endod , vol.9 , pp. 137-142
    • Yamada, R.S.1    Armas, A.2    Goldman, M.3    Lin, P.S.4
  • 8
    • 25144482896 scopus 로고    scopus 로고
    • The effects of temperature on sodium hypochlorite short-term stability, pulp dissolution capacity, and antimicrobial efficacy
    • Sirtes G., Waltimo T., Schaetzle M., and Zehnder M. The effects of temperature on sodium hypochlorite short-term stability, pulp dissolution capacity, and antimicrobial efficacy. J Endod 31 (2005) 669-671
    • (2005) J Endod , vol.31 , pp. 669-671
    • Sirtes, G.1    Waltimo, T.2    Schaetzle, M.3    Zehnder, M.4
  • 9
    • 4143097917 scopus 로고    scopus 로고
    • Current challenges and concepts in the preparation of root canal systems: a review
    • Peters O.A. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30 (2004) 559-597
    • (2004) J Endod , vol.30 , pp. 559-597
    • Peters, O.A.1
  • 10
    • 0033110728 scopus 로고    scopus 로고
    • Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files
    • Pettiette M.T., Metzger Z., Phillips C., and Trope M. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files. J Endod 25 (1999) 230-234
    • (1999) J Endod , vol.25 , pp. 230-234
    • Pettiette, M.T.1    Metzger, Z.2    Phillips, C.3    Trope, M.4
  • 11
    • 0035496468 scopus 로고    scopus 로고
    • Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the Am J of Dentistry
    • Bergmans L., Van Cleynenbreugel J., Wevers M., and Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the Am J of Dentistry. Am J Dent 14 (2001) 324-333
    • (2001) Am J Dent , vol.14 , pp. 324-333
    • Bergmans, L.1    Van Cleynenbreugel, J.2    Wevers, M.3    Lambrechts, P.4
  • 12
    • 0036528158 scopus 로고    scopus 로고
    • Dynamic torque and apical forces of ProFile. 04 rotary instruments during preparation of curved canals
    • Peters O.A., and Barbakow F. Dynamic torque and apical forces of ProFile. 04 rotary instruments during preparation of curved canals. Int Endod J 35 (2002) 379-389
    • (2002) Int Endod J , vol.35 , pp. 379-389
    • Peters, O.A.1    Barbakow, F.2
  • 13
    • 33646345401 scopus 로고    scopus 로고
    • Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments
    • Bahia M.G.A., Melo M.C.C., and Buono V.T.L. Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instruments. Oral Surg Oral Med Oral Path Oral Radiol Endod 101 (2006) 675-680
    • (2006) Oral Surg Oral Med Oral Path Oral Radiol Endod , vol.101 , pp. 675-680
    • Bahia, M.G.A.1    Melo, M.C.C.2    Buono, V.T.L.3
  • 15
    • 0242721011 scopus 로고    scopus 로고
    • The effect of cleaning procedures on fracture properties and corrosion of NiTi files
    • O'Hoy P.Y., Messer H.H., and Palamara J.E. The effect of cleaning procedures on fracture properties and corrosion of NiTi files. Int Endod J 36 (2003) 724-732
    • (2003) Int Endod J , vol.36 , pp. 724-732
    • O'Hoy, P.Y.1    Messer, H.H.2    Palamara, J.E.3
  • 16
    • 4644257082 scopus 로고    scopus 로고
    • Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions
    • Darabara M., Bourithis L., Zinelis S., and Papadimitriou G.D. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J 37 (2004) 705-710
    • (2004) Int Endod J , vol.37 , pp. 705-710
    • Darabara, M.1    Bourithis, L.2    Zinelis, S.3    Papadimitriou, G.D.4
  • 17
    • 34147114494 scopus 로고    scopus 로고
    • Korrosion von Nickel-Titan-Instrumenten
    • Sonntag D., and Heithecker K. Korrosion von Nickel-Titan-Instrumenten. Endodontie 15 (2006) 23-30
    • (2006) Endodontie , vol.15 , pp. 23-30
    • Sonntag, D.1    Heithecker, K.2
  • 18
    • 33847033756 scopus 로고    scopus 로고
    • Impact of lubricant parameter on rotary instrument torque and force
    • Boessler C., Peters O.A., and Zehnder M. Impact of lubricant parameter on rotary instrument torque and force. J Endod 33 (2007) 280-283
    • (2007) J Endod , vol.33 , pp. 280-283
    • Boessler, C.1    Peters, O.A.2    Zehnder, M.3
  • 19
    • 33947124998 scopus 로고    scopus 로고
    • Effect of prion decontamination protocols on Nickel-Titanium rotary surfaces
    • in press
    • Sonntag D., and Peters O.A. Effect of prion decontamination protocols on Nickel-Titanium rotary surfaces. J Endod (2007) in press
    • (2007) J Endod
    • Sonntag, D.1    Peters, O.A.2
  • 20
    • 33747144201 scopus 로고    scopus 로고
    • Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper rotary instruments
    • Berutti E., Angelini E., Rigolone M., et al. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper rotary instruments. Int Endod J 39 (2006) 693-699
    • (2006) Int Endod J , vol.39 , pp. 693-699
    • Berutti, E.1    Angelini, E.2    Rigolone, M.3
  • 22
    • 0036545858 scopus 로고    scopus 로고
    • Engine-driven preparation of curved root canals: measuring cyclic fatigue and other physical parameters
    • Peters O.A., Kappeler S., Bucher W., and Barbakow F. Engine-driven preparation of curved root canals: measuring cyclic fatigue and other physical parameters. Aust Endod J 28 (2002) 11-17
    • (2002) Aust Endod J , vol.28 , pp. 11-17
    • Peters, O.A.1    Kappeler, S.2    Bucher, W.3    Barbakow, F.4
  • 23
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haikel Y., Serfaty R., Bateman G., et al. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3
  • 24
    • 33748746918 scopus 로고    scopus 로고
    • The effect of sodium hypochlorite on the surface characteristics and fatigue resistance of ProFile nickel-titanium instruments
    • Castro Martins R., Bahia M.G.A., and Buono V.T.L. The effect of sodium hypochlorite on the surface characteristics and fatigue resistance of ProFile nickel-titanium instruments. Oral Surg Oral Med Oral Path Oral Radiol Endod 102 (2006) 99-105
    • (2006) Oral Surg Oral Med Oral Path Oral Radiol Endod , vol.102 , pp. 99-105
    • Castro Martins, R.1    Bahia, M.G.A.2    Buono, V.T.L.3
  • 25
    • 2942659317 scopus 로고    scopus 로고
    • Hydrogen embrittlement of work-hardened Ni-Ti alloy in fluoride solutions
    • Yokoyama K., Kaneko K., Ogawa T., et al. Hydrogen embrittlement of work-hardened Ni-Ti alloy in fluoride solutions. Biomaterials 26 (2005) 101-108
    • (2005) Biomaterials , vol.26 , pp. 101-108
    • Yokoyama, K.1    Kaneko, K.2    Ogawa, T.3
  • 26
    • 0036777866 scopus 로고    scopus 로고
    • Fatigue and mechanical properties of nickel-titanium endodontic instruments
    • Kuhn G., and Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endod 28 (2002) 716-720
    • (2002) J Endod , vol.28 , pp. 716-720
    • Kuhn, G.1    Jordan, L.2
  • 27
    • 0032214962 scopus 로고    scopus 로고
    • Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment
    • Haikel Y., Serfaty R., Wilson P., et al. Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24 (1998) 731-735
    • (1998) J Endod , vol.24 , pp. 731-735
    • Haikel, Y.1    Serfaty, R.2    Wilson, P.3
  • 29
    • 0842333861 scopus 로고    scopus 로고
    • Cleaning of rotary nickel-titanium endodontic instruments
    • Linsuwanont P., Parashos P., and Messer H.H. Cleaning of rotary nickel-titanium endodontic instruments. Int Endod J 37 (2004) 19-28
    • (2004) Int Endod J , vol.37 , pp. 19-28
    • Linsuwanont, P.1    Parashos, P.2    Messer, H.H.3
  • 30
    • 0034666762 scopus 로고    scopus 로고
    • Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
    • Thierry B., Tabrizian M., Trepanier C., et al. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res 51 (2000) 685-693
    • (2000) J Biomed Mater Res , vol.51 , pp. 685-693
    • Thierry, B.1    Tabrizian, M.2    Trepanier, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.