메뉴 건너뛰기




Volumn 15, Issue 7, 2009, Pages 1027-1030

Fabrication and characterization of a polymethyl methacrylate continuous-flow PCR microfluidic chip using CO2 laser ablation

Author keywords

[No Author keywords available]

Indexed keywords

BASE PAIRS; CONTINUOUS-FLOW; DNA-TEMPLATE; FABRICATION PROCESS; HEATING SYSTEM; HIGH FLEXIBILITY; LASER ABLATION TECHNIQUE; LASER FABRICATION; LASER OUTPUT POWER; LASER SCANNING VELOCITY; LOW COSTS; LOW POWER; MICROFABRICATION METHODS; MICROFLUIDIC CHIP; POLYMERASE CHAIN REACTION;

EID: 67650450447     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-009-0843-0     Document Type: Article
Times cited : (37)

References (18)
  • 1
    • 0033732466 scopus 로고    scopus 로고
    • Hot embossing as a method for the fabrication of polymer high aspect ratio structures
    • 10.1016/S0924-4247(00)00296-X
    • H Becker U Heim 2000 Hot embossing as a method for the fabrication of polymer high aspect ratio structures Sens Actuators A Phys 83 130 135 10.1016/S0924-4247(00)00296-X
    • (2000) Sens Actuators A Phys , vol.83 , pp. 130-135
    • Becker, H.1    Heim, U.2
  • 4
    • 33749182056 scopus 로고    scopus 로고
    • Application of Real Time PCR in post transplant monitoring of cytomegalovirus infection: Comparison with other diagnostic approaches
    • A Gaeta C Nazzari S Verzaro MC Latte G Fabri C Mancini 2006 Application of real time PCR in post transplant monitoring of cytomegalovirus infection: comparison with other diagnostic approaches New Microbiol 29 185 192 (Pubitemid 44476552)
    • (2006) New Microbiologica , vol.29 , Issue.3 , pp. 185-192
    • Gaeta, A.1    Nazzari, C.2    Verzaro, S.3    Latte, M.C.4    Fabri, G.5    Mancini, C.6
  • 6
    • 27744529987 scopus 로고    scopus 로고
    • Development of a real-time RT-PCR assay for detection and quantitation of parainfluenza virus 3
    • 10.1016/j.jviromet.2005.06.014
    • AZ Hu M Colella PZ Zhao FL Li JS Tam R Rappaport SM Cheng 2006 Development of a real-time RT-PCR assay for detection and quantitation of parainfluenza virus 3 J Virol Methods 130 145 148 10.1016/j.jviromet.2005.06.014
    • (2006) J Virol Methods , vol.130 , pp. 145-148
    • Hu, A.Z.1    Colella, M.2    Zhao, P.Z.3    Li, F.L.4    Tam, J.S.5    Rappaport, R.6    Cheng, S.M.7
  • 7
    • 15244349874 scopus 로고    scopus 로고
    • 2 laser system: characterization and fabrication of cavities produced by raster scanning of the laser beam
    • 10.1039/b308153b
    • 2 laser system: characterization and fabrication of cavities produced by raster scanning of the laser beam Lab Chip 3 302 307 10.1039/b308153b
    • (2003) Lab Chip , vol.3 , pp. 302-307
    • Jensen, M.F.1    Noerholm, M.2    Christensen, L.H.3    Geschke, O.4
  • 8
    • 0042040751 scopus 로고    scopus 로고
    • CO, laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems
    • 10.1039/b206409j
    • H Klank JP Kutter O Geschke 2000 CO, laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems Lab Chip 2 242 246 10.1039/b206409j
    • (2000) Lab Chip , vol.2 , pp. 242-246
    • Klank, H.1    Kutter, J.P.2    Geschke, O.3
  • 9
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: continuous-flow PCR on a chip
    • 10.1126/science.280.5366.1046
    • MU Kopp AJ De Mello A Manz 1998 Chemical amplification: continuous-flow PCR on a chip Science 280 1046 1048 10.1126/science.280.5366.1046
    • (1998) Science , vol.280 , pp. 1046-1048
    • Kopp, M.U.1    De Mello, A.J.2    Manz, A.3
  • 10
    • 33748056478 scopus 로고    scopus 로고
    • The mechanical properties of MWNT/PMMA nanocomposites fabricated by modified injection molding
    • 10.1016/j.compstruct.2005.11.008
    • WJ Lee SE Lee CG Kim 2006 The mechanical properties of MWNT/PMMA nanocomposites fabricated by modified injection molding Compos Struct 76 406 410 10.1016/j.compstruct.2005.11.008
    • (2006) Compos Struct , vol.76 , pp. 406-410
    • Lee, W.J.1    Lee, S.E.2    Kim, C.G.3
  • 11
    • 27644552128 scopus 로고    scopus 로고
    • A comparative study of channel formation in polymer materials using VUV and UV nano-second laser sources for use in micro-fluidic applications
    • 10.1117/12.605144
    • S McGinty GM O'Commor TJ Glynn 2005 A comparative study of channel formation in polymer materials using VUV and UV nano-second laser sources for use in micro-fluidic applications Proc SPIE Optoelectron Photonic Devices Opt Netw 5825 622 633 10.1117/12.605144
    • (2005) Proc SPIE Optoelectron Photonic Devices Opt Netw , vol.5825 , pp. 622-633
    • McGinty, S.1    O'Commor, G.M.2    Glynn, T.J.3
  • 12
    • 0141426476 scopus 로고    scopus 로고
    • Continuous-flow DNA and RNA amplification chip combined with laser-induced fluorescence detection
    • 10.1016/S0003-2670(03)00898-5
    • PJ Obeid TK Christopoulos 2003 Continuous-flow DNA and RNA amplification chip combined with laser-induced fluorescence detection Anal Chim Acta 494 1 9 10.1016/S0003-2670(03)00898-5
    • (2003) Anal Chim Acta , vol.494 , pp. 1-9
    • Obeid, P.J.1    Christopoulos, T.K.2
  • 13
    • 10744227060 scopus 로고    scopus 로고
    • Miniaturized flow-through PCR with different template types in a silicon chip thermocycler
    • 10.1039/b103846j
    • I Schneegaß R Bräutigam JM Köhler 2001 Miniaturized flow-through PCR with different template types in a silicon chip thermocycler Lab Chip 1 42 49 10.1039/b103846j
    • (2001) Lab Chip , vol.1 , pp. 42-49
    • I. Schneegaß1    R. Bräutigam2    J.M. Köhler3
  • 14
    • 29944439904 scopus 로고    scopus 로고
    • Polymeric microfluidic system for DNA analysis
    • 10.1016/j.aca.2005.09.035
    • Y Sun YC Kwok 2006 Polymeric microfluidic system for DNA analysis Anal Chim Acta 556 80 96 10.1016/j.aca.2005.09.035
    • (2006) Anal Chim Acta , vol.556 , pp. 80-96
    • Sun, Y.1    Kwok, Y.C.2
  • 15
    • 0037095347 scopus 로고    scopus 로고
    • A heater-integrated transparent microchannel chip for continuous-flow PCR
    • 10.1016/S0925-4005(02)00016-3
    • K Sun A Yamaguchi Y Ishida S Matsuo H Misawa 2002 A heater-integrated transparent microchannel chip for continuous-flow PCR Sens Actuators B Chem 84 283 289 10.1016/S0925-4005(02)00016-3
    • (2002) Sens Actuators B Chem , vol.84 , pp. 283-289
    • Sun, K.1    Yamaguchi, A.2    Ishida, Y.3    Matsuo, S.4    Misawa, H.5
  • 16
    • 2442589520 scopus 로고    scopus 로고
    • Protein patterning in polycarbonate microfluidic channels
    • 10.1117/12.524675
    • DA Thomson JP Hayes H Thissen 2003 Protein patterning in polycarbonate microfluidic channels Proc SPIE BioMEMS Nanotechnol 5275 161 167 10.1117/12.524675
    • (2003) Proc SPIE BioMEMS Nanotechnol , vol.5275 , pp. 161-167
    • Thomson, D.A.1    Hayes, J.P.2    Thissen, H.3
  • 18
    • 0029989857 scopus 로고    scopus 로고
    • Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device
    • 10.1021/ac960718q
    • AT Woolley D Hadley P Landre AJ De Mello RA Mathies MA Northrup 1996 Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device Anal Chem 68 4081 4086 10.1021/ac960718q
    • (1996) Anal Chem , vol.68 , pp. 4081-4086
    • Woolley, A.T.1    Hadley, D.2    Landre, P.3    De Mello, A.J.4    Mathies, R.A.5    Northrup, M.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.