메뉴 건너뛰기




Volumn 10, Issue 1, 2008, Pages 21-26

Fracture properties of an acrylic bone cement

Author keywords

Biomaterials; Cement; Fatigue; Fracture properties; Fracture toughness

Indexed keywords

BONE CEMENT; POLY(METHYL METHACRYLATE);

EID: 47049103284     PISSN: 1509409X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (34)

References (61)
  • 2
    • 0025388865 scopus 로고
    • A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms
    • TOPOLESKI L.D. et al., A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms, Journal of Biomedical Materials Research, 1990, 24, 2, 135-154.
    • (1990) Journal of Biomedical Materials Research , vol.24 , Issue.2 , pp. 135-154
    • TOPOLESKI, L.D.1
  • 4
    • 0031886313 scopus 로고    scopus 로고
    • Quantitative assessment of walking activity after total hip or knee replacement
    • SCHMALZRIED T.P. et al., Quantitative assessment of walking activity after total hip or knee replacement, J. Bone Joint Surg. Am., 1998, 80, 1, 54-59.
    • (1998) J. Bone Joint Surg. Am , vol.80 , Issue.1 , pp. 54-59
    • SCHMALZRIED, T.P.1
  • 6
    • 34247108723 scopus 로고    scopus 로고
    • Cement mantle fatigue failure in total hip replacement: Experimental and computational testing
    • JEFFERS J.R. et al., Cement mantle fatigue failure in total hip replacement: experimental and computational testing, J. Biomech, 2007, 40, 7, 1525-1533.
    • (2007) J. Biomech , vol.40 , Issue.7 , pp. 1525-1533
    • JEFFERS, J.R.1
  • 7
    • 35048861484 scopus 로고    scopus 로고
    • CRISTOFOLINI L. et al., Preclinical assessment of the long-term endurance of cemented hip stems. Part 1. Effect of daily activities - a comparison of two load histories, Proc. Inst. Mech. Eng. [H], 2007, 221, 6, 569-584.
    • CRISTOFOLINI L. et al., Preclinical assessment of the long-term endurance of cemented hip stems. Part 1. Effect of daily activities - a comparison of two load histories, Proc. Inst. Mech. Eng. [H], 2007, 221, 6, 569-584.
  • 8
    • 34548167626 scopus 로고    scopus 로고
    • CRISTOFOLINI L. et al., Preclinical assessment of the long-term endurance of cemented hip stems. Part 2. In-vitro and ex-vivo fatigue damage of the cement mantle, Proc. Inst. Mech. Eng. [H], 2007, 221, 6, 585-599.
    • CRISTOFOLINI L. et al., Preclinical assessment of the long-term endurance of cemented hip stems. Part 2. In-vitro and ex-vivo fatigue damage of the cement mantle, Proc. Inst. Mech. Eng. [H], 2007, 221, 6, 585-599.
  • 9
    • 3343006998 scopus 로고    scopus 로고
    • Cement microcracks in thin-mantle regions after in vitro fatigue loading
    • MANN K.A. et al., Cement microcracks in thin-mantle regions after in vitro fatigue loading, J. Arthroplasty, 2004, 19, 5, 605-612.
    • (2004) J. Arthroplasty , vol.19 , Issue.5 , pp. 605-612
    • MANN, K.A.1
  • 10
    • 4644221748 scopus 로고    scopus 로고
    • Computer simulation on fatigue behavior of cemented hip prostheses: A physiological model
    • HUNG J.P. et al., Computer simulation on fatigue behavior of cemented hip prostheses: a physiological model, Comput Methods Programs Biomed, 2004, 76, 2, 103-113.
    • (2004) Comput Methods Programs Biomed , vol.76 , Issue.2 , pp. 103-113
    • HUNG, J.P.1
  • 11
    • 0043171162 scopus 로고    scopus 로고
    • Mechanical simulation of muscle loading on the proximal femur: Analysis of cemented femoral component migration with and without muscle loading
    • BRITTON J.R. et al., Mechanical simulation of muscle loading on the proximal femur: analysis of cemented femoral component migration with and without muscle loading, Clin. Biomech. (Bristol, Avon), 2003, 18, 7, 637-646.
    • (2003) Clin. Biomech. (Bristol, Avon) , vol.18 , Issue.7 , pp. 637-646
    • BRITTON, J.R.1
  • 12
    • 0036918429 scopus 로고    scopus 로고
    • Stair climbing is more detrimental to the cement in hip replacement than walking
    • STOLK J. et al., Stair climbing is more detrimental to the cement in hip replacement than walking, Clin. Orthop. Relat. Res., 2002, 405, 294-305.
    • (2002) Clin. Orthop. Relat. Res , vol.405 , pp. 294-305
    • STOLK, J.1
  • 13
    • 24644437293 scopus 로고    scopus 로고
    • In vivo behavior of acrylic bone cement in total hip arthroplasty
    • RIES M.D. et al., In vivo behavior of acrylic bone cement in total hip arthroplasty, Biomaterials, 2006, 27, 2, 256-261.
    • (2006) Biomaterials , vol.27 , Issue.2 , pp. 256-261
    • RIES, M.D.1
  • 14
    • 0035236288 scopus 로고    scopus 로고
    • Some failure modes of four clinical bone cements
    • LIU C. et al., Some failure modes of four clinical bone cements, Proc. Inst. Mech. Eng. [H], 2001, 215, 4, 359-366.
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , Issue.4 , pp. 359-366
    • LIU, C.1
  • 15
    • 0030561029 scopus 로고    scopus 로고
    • Subsidence of the stems due to acrylic cement creep is extremely sensitive to interface friction
    • VERDONSCHOT N., HUISKES R., Subsidence of the stems due to acrylic cement creep is extremely sensitive to interface friction, J. Biomech., 1996, 29, 12, 1569-1575.
    • (1996) J. Biomech , vol.29 , Issue.12 , pp. 1569-1575
    • VERDONSCHOT, N.1    HUISKES, R.2
  • 16
    • 0031765525 scopus 로고    scopus 로고
    • Cemented femoral stem performance. effects of proximal bonding, geometry, and neck length
    • CHANG P.B. et al., Cemented femoral stem performance. effects of proximal bonding, geometry, and neck length, Clinical Orthopaedics and Related Research, 1998, 355, 57-69.
    • (1998) Clinical Orthopaedics and Related Research , vol.355 , pp. 57-69
    • CHANG, P.B.1
  • 17
    • 0033647005 scopus 로고    scopus 로고
    • Toward standardization of methods of determination of fracture properties of acrylic bone cement and statistical analysis of test results
    • LEWIS G., NYMAN J.S., Toward standardization of methods of determination of fracture properties of acrylic bone cement and statistical analysis of test results, Journal of Biomedical Materials Research, 2000, 53, 6, 748-768.
    • (2000) Journal of Biomedical Materials Research , vol.53 , Issue.6 , pp. 748-768
    • LEWIS, G.1    NYMAN, J.S.2
  • 18
    • 23844536198 scopus 로고    scopus 로고
    • Effect of hip stem taper on cement stresses
    • NEW A.M. et al., Effect of hip stem taper on cement stresses, Orthopedics, 2005, 28, 8 Suppl, 857-862.
    • (2005) Orthopedics , vol.28 , Issue.8 SUPPL. , pp. 857-862
    • NEW, A.M.1
  • 19
    • 0038785745 scopus 로고    scopus 로고
    • Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: Finite element analysis
    • MASSIN P. et al., Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis, Rev. Chir. Orthop. Reparatrice Appar. Mot., 2003, 89, 2, 134-143.
    • (2003) Rev. Chir. Orthop. Reparatrice Appar. Mot , vol.89 , Issue.2 , pp. 134-143
    • MASSIN, P.1
  • 20
    • 0141792462 scopus 로고    scopus 로고
    • Comparative in vitro study on the long term performance of cemented hip stems: Validation of a protocol to discriminate between "good" and "bad" designs
    • CRISTOFOLINI L. et al., Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between "good" and "bad" designs, J. Biomech., 2003, 36, 11, 1603-1615.
    • (2003) J. Biomech , vol.36 , Issue.11 , pp. 1603-1615
    • CRISTOFOLINI, L.1
  • 21
    • 0036312327 scopus 로고    scopus 로고
    • Fatigue crack growth rate does not depend on mantle thickness: An idealized cemented stem construct under torsional loading
    • HERTZLER J. et al., Fatigue crack growth rate does not depend on mantle thickness: an idealized cemented stem construct under torsional loading, J. Orthop. Res., 2002, 20, 4, 676-682.
    • (2002) J. Orthop. Res , vol.20 , Issue.4 , pp. 676-682
    • HERTZLER, J.1
  • 22
    • 0141993593 scopus 로고    scopus 로고
    • AYERS D., MANN K., The importance of proximal cement filling of the calcar region: a biomechanical justification, J. Arthroplasty, 2003, 18, 7 Suppl 1, 103-109.
    • AYERS D., MANN K., The importance of proximal cement filling of the calcar region: a biomechanical justification, J. Arthroplasty, 2003, 18, 7 Suppl 1, 103-109.
  • 23
    • 33947704275 scopus 로고    scopus 로고
    • Investigation into the effect of cementing techniques on load transfer in the resurfaced femoral head: A multi-femur finite element analysis
    • RADCLIFFE I.A., TAYLOR M., Investigation into the effect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis, Clin. Biomech. (Bristol, Avon), 2007, 22, 4, 422-430.
    • (2007) Clin. Biomech. (Bristol, Avon) , vol.22 , Issue.4 , pp. 422-430
    • RADCLIFFE, I.A.1    TAYLOR, M.2
  • 24
    • 0030298348 scopus 로고    scopus 로고
    • An analysis of crack propagation paths at implant/bone-cement interfaces
    • MCCORMACK B.A., PRENDERGAST P.J., An analysis of crack propagation paths at implant/bone-cement interfaces, J. Biomech. Eng., 1996, 118, 4, 579-585.
    • (1996) J. Biomech. Eng , vol.118 , Issue.4 , pp. 579-585
    • MCCORMACK, B.A.1    PRENDERGAST, P.J.2
  • 25
    • 0032778690 scopus 로고    scopus 로고
    • The influence of the time-dependent properties of bone cement on stress in the femoral cement mantle of total hip arthroplasty
    • WHEELER J.P. et al., The influence of the time-dependent properties of bone cement on stress in the femoral cement mantle of total hip arthroplasty, J. Mater. Sci. Mater. Med., 1999, 10, 8, 497-501.
    • (1999) J. Mater. Sci. Mater. Med , vol.10 , Issue.8 , pp. 497-501
    • WHEELER, J.P.1
  • 26
    • 0024000434 scopus 로고
    • Fatigue properties of acrylic bone cements: Review of the literature
    • KRAUSE W., MATHIS R.S., Fatigue properties of acrylic bone cements: review of the literature, Journal of Biomedical Materials Research, 1988, 22, A1 Suppl, 37-53.
    • (1988) Journal of Biomedical Materials Research , vol.22 , Issue.A1 SUPPL. , pp. 37-53
    • KRAUSE, W.1    MATHIS, R.S.2
  • 27
    • 0024246219 scopus 로고
    • Fatigue properties of acrylic bone cement: S-N, P-N, and P-S-N data
    • KRAUSE W. et al., Fatigue properties of acrylic bone cement: S-N, P-N, and P-S-N data, Journal of Biomedical Materials Research, 1988, 22, 3 Suppl, 221-244.
    • (1988) Journal of Biomedical Materials Research , vol.22 , Issue.3 SUPPL. , pp. 221-244
    • KRAUSE, W.1
  • 28
    • 0033814276 scopus 로고    scopus 로고
    • Tensile characteristics of ten commercial acrylic bone cements
    • HARPER E.J., BONFIELD W., Tensile characteristics of ten commercial acrylic bone cements, Journal of Biomedical Materials Research, 2000, 53, 5, 605-616.
    • (2000) Journal of Biomedical Materials Research , vol.53 , Issue.5 , pp. 605-616
    • HARPER, E.J.1    BONFIELD, W.2
  • 29
    • 0017758413 scopus 로고
    • The modulus of elasticity and flexural strength of some acrylic bone cements
    • HOLM N.J., The modulus of elasticity and flexural strength of some acrylic bone cements, Acta Orthopaedica Scandinavica, 1977, 48, 5, 436-442.
    • (1977) Acta Orthopaedica Scandinavica , vol.48 , Issue.5 , pp. 436-442
    • HOLM, N.J.1
  • 30
    • 0033996523 scopus 로고    scopus 로고
    • Correlation between impact strength and fracture toughness of pmma-based bone cements
    • LEWIS G., MLADSI S., Correlation between impact strength and fracture toughness of pmma-based bone cements, Biomaterials, 2000, 21, 775-781.
    • (2000) Biomaterials , vol.21 , pp. 775-781
    • LEWIS, G.1    MLADSI, S.2
  • 31
    • 11244337458 scopus 로고    scopus 로고
    • A procedure and criterion for bone cement fracture toughness tests
    • GUANDALINI L. et al., A procedure and criterion for bone cement fracture toughness tests, Proc. Inst. Mech. Eng. [H], 2004, 218, 6, 445-450.
    • (2004) Proc. Inst. Mech. Eng. [H] , vol.218 , Issue.6 , pp. 445-450
    • GUANDALINI, L.1
  • 32
  • 33
    • 84871119282 scopus 로고
    • Asm Handbook
    • ASM International, Materials Park
    • NEWBY J., Asm Handbook, Volume 8. Mechanical Testing, ASM International, Materials Park, 1992.
    • (1992) Mechanical Testing , vol.8
    • NEWBY, J.1
  • 34
    • 0842268582 scopus 로고    scopus 로고
    • The influence of the viscosity classification of an acrylic bone cement on its in vitro fatigue performance
    • LEWIS G., JANNA S., The influence of the viscosity classification of an acrylic bone cement on its in vitro fatigue performance, Bio-Medical Materials and Engineering, 2004, 14, 1, 33-42.
    • (2004) Bio-Medical Materials and Engineering , vol.14 , Issue.1 , pp. 33-42
    • LEWIS, G.1    JANNA, S.2
  • 35
    • 16444384258 scopus 로고    scopus 로고
    • Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: Barium sulfate-containing cement versus iodine-containing cement
    • LEWIS G. et al., Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: barium sulfate-containing cement versus iodine-containing cement, Journal of Biomedical Materials Research (Applied Biomaterials), 2005, 73, 1, 77-87.
    • (2005) Journal of Biomedical Materials Research (Applied Biomaterials) , vol.73 , Issue.1 , pp. 77-87
    • LEWIS, G.1
  • 36
    • 0037089654 scopus 로고    scopus 로고
    • Mechanical performance of acrylic bone cements containing different radiopacifying agents
    • GINEBRA M.P. et al., Mechanical performance of acrylic bone cements containing different radiopacifying agents, Biomaterials, 2002, 23, 8, 1873-1882.
    • (2002) Biomaterials , vol.23 , Issue.8 , pp. 1873-1882
    • GINEBRA, M.P.1
  • 38
    • 47049125659 scopus 로고    scopus 로고
    • Influence of specimen molding technique on fatigue properties of a bone cement
    • PENNATI G. et al., Influence of specimen molding technique on fatigue properties of a bone cement, Journal of Applied Biomaterials and Biomechanics, 2003, 1, 2, 148-153.
    • (2003) Journal of Applied Biomaterials and Biomechanics , vol.1 , Issue.2 , pp. 148-153
    • PENNATI, G.1
  • 39
    • 0034980107 scopus 로고    scopus 로고
    • Influence of mixing techniques on the physical properties of acrylic bone cement
    • DUNNE N.J., ORR J.F., Influence of mixing techniques on the physical properties of acrylic bone cement, Biomaterials, 2001, 22, 13, 1819-1826.
    • (2001) Biomaterials , vol.22 , Issue.13 , pp. 1819-1826
    • DUNNE, N.J.1    ORR, J.F.2
  • 40
    • 0037210089 scopus 로고    scopus 로고
    • The relationship between porosity and fatigue characteristics of bone cements
    • DUNNE N.J. et al., The relationship between porosity and fatigue characteristics of bone cements, Biomaterials, 2003, 24, 2, 239-245.
    • (2003) Biomaterials , vol.24 , Issue.2 , pp. 239-245
    • DUNNE, N.J.1
  • 41
    • 0033635099 scopus 로고    scopus 로고
    • Fracture and fatigue properties of acrylic bone cement: The effects of mixing method, sterilization treatment, and molecular weight
    • GRAHAM J. et al., Fracture and fatigue properties of acrylic bone cement: the effects of mixing method, sterilization treatment, and molecular weight, The Journal of Arthroplasty, 2000, 15, 8, 1028-1035.
    • (2000) The Journal of Arthroplasty , vol.15 , Issue.8 , pp. 1028-1035
    • GRAHAM, J.1
  • 42
    • 0032951762 scopus 로고    scopus 로고
    • Effect of mixing method and storage temperature of cement constituents on the fatigue and porosity of acrylic bone cement
    • LEWIS G., Effect of mixing method and storage temperature of cement constituents on the fatigue and porosity of acrylic bone cement, Journal of Biomedical Materials Research (Applied Biomaterials), 1999, 48, 2, 143-149.
    • (1999) Journal of Biomedical Materials Research (Applied Biomaterials) , vol.48 , Issue.2 , pp. 143-149
    • LEWIS, G.1
  • 43
    • 0032894783 scopus 로고    scopus 로고
    • Apparent fracture toughness of acrylic bone cement: Effect of test specimen configuration and sterilization method
    • LEWIS G., Apparent fracture toughness of acrylic bone cement: effect of test specimen configuration and sterilization method, Biomaterials, 1999, 20, 1, 69-78.
    • (1999) Biomaterials , vol.20 , Issue.1 , pp. 69-78
    • LEWIS, G.1
  • 44
    • 0037677765 scopus 로고    scopus 로고
    • Effect of test specimen cross-sectional shape on the in vitro fatigue life of acrylic bone cement
    • LEWIS G., JANNA S., Effect of test specimen cross-sectional shape on the in vitro fatigue life of acrylic bone cement, Biomaterials, 2003, 24, 23, 4315-4321.
    • (2003) Biomaterials , vol.24 , Issue.23 , pp. 4315-4321
    • LEWIS, G.1    JANNA, S.2
  • 46
    • 0022723858 scopus 로고
    • Molecular and mechanical property changes during aging of bone cement in vitro and in vivo
    • LOONEY M.A., PARK J.B., Molecular and mechanical property changes during aging of bone cement in vitro and in vivo, J. Biomed. Mater. Res., 1986, 20, 5, 555-63.
    • (1986) J. Biomed. Mater. Res , vol.20 , Issue.5 , pp. 555-563
    • LOONEY, M.A.1    PARK, J.B.2
  • 47
    • 0022590581 scopus 로고
    • In vivo versus in vitro polymerization of acrylic bone cement: Effect on material properties
    • BARGAR W.L. et al., In vivo versus in vitro polymerization of acrylic bone cement: effect on material properties, Journal of Orthopaedic Research, 1986, 4, 1, 86-89.
    • (1986) Journal of Orthopaedic Research , vol.4 , Issue.1 , pp. 86-89
    • BARGAR, W.L.1
  • 48
    • 35548943181 scopus 로고    scopus 로고
    • NOTTROTT M. et al., Time dependent mechanical properties of bone cement. An in vitro study over one year, J. Biomed. Mater. Res. B, Appl. Biomater., 2007, 83, 2, 416-421.
    • NOTTROTT M. et al., Time dependent mechanical properties of bone cement. An in vitro study over one year, J. Biomed. Mater. Res. B, Appl. Biomater., 2007, 83, 2, 416-421.
  • 49
    • 0035735447 scopus 로고    scopus 로고
    • MINARI C. et al., The effect on the fatigue strength of bone cement of adding sodium fluoride, Proceedings of the Institutions of Mechanical Engineers Part H, 2001, 215, 2, 251-253.
    • MINARI C. et al., The effect on the fatigue strength of bone cement of adding sodium fluoride, Proceedings of the Institutions of Mechanical Engineers Part H, 2001, 215, 2, 251-253.
  • 51
    • 0037277103 scopus 로고    scopus 로고
    • Fatigue strength of pmma bone cement mixed with gentamicin and barium sulphate vs pure pmma
    • BALEANI M. et al., Fatigue strength of pmma bone cement mixed with gentamicin and barium sulphate vs pure pmma, Proc. Inst. Mech. Eng. [H], 2003, 217, 1, 9-12.
    • (2003) Proc. Inst. Mech. Eng. [H] , vol.217 , Issue.1 , pp. 9-12
    • BALEANI, M.1
  • 52
    • 0034318763 scopus 로고    scopus 로고
    • On the magnitude and variability of the fatigue strength of acrylic bone cement
    • MURPHY B.P., PRENDERGAST P.J., On the magnitude and variability of the fatigue strength of acrylic bone cement, International Journal of Fatigue, 2000, 22, 855-864.
    • (2000) International Journal of Fatigue , vol.22 , pp. 855-864
    • MURPHY, B.P.1    PRENDERGAST, P.J.2
  • 53
    • 0033928607 scopus 로고    scopus 로고
    • Relative influence of composition and viscosity of acrylic bone cement on its apparent fracture toughness
    • LEWIS G., Relative influence of composition and viscosity of acrylic bone cement on its apparent fracture toughness, Bio-Medical Materials and Engineering, 2000, 10, 1, 1-11.
    • (2000) Bio-Medical Materials and Engineering , vol.10 , Issue.1 , pp. 1-11
    • LEWIS, G.1
  • 54
    • 34250015819 scopus 로고    scopus 로고
    • The effect of gentamicin sulphate on the fracture properties of a manually mixed bone cement
    • BALEANI M. et al., The effect of gentamicin sulphate on the fracture properties of a manually mixed bone cement, Fatigue & Fracture of Enginneering Materials & Structures, 2007, 30, 479-488.
    • (2007) Fatigue & Fracture of Enginneering Materials & Structures , vol.30 , pp. 479-488
    • BALEANI, M.1
  • 55
    • 0028671970 scopus 로고
    • Mechanical properties of vaccummixed acrylic bone cement
    • LEWIS G., AUSTIN G., Mechanical properties of vaccummixed acrylic bone cement, Journal of Applied Biomaterials, 1994, 5, 307-314.
    • (1994) Journal of Applied Biomaterials , vol.5 , pp. 307-314
    • LEWIS, G.1    AUSTIN, G.2
  • 56
    • 15944424328 scopus 로고    scopus 로고
    • Influence of the method of blending an antibiotic powder with an acrylic bone cement powder on physical, mechanical, and thermal properties of the cured cement
    • LEWIS G. et al., Influence of the method of blending an antibiotic powder with an acrylic bone cement powder on physical, mechanical, and thermal properties of the cured cement, Biomaterials, 2005, 26, 20, 4317-4325.
    • (2005) Biomaterials , vol.26 , Issue.20 , pp. 4317-4325
    • LEWIS, G.1
  • 57
    • 0021234258 scopus 로고
    • The effect of antibiotic additions on the fracture properties of bone cements
    • WRIGHT T.M. et al., The effect of antibiotic additions on the fracture properties of bone cements, Acta Orthopaedica Scandinavica, 1984, 55, 4, 414-418.
    • (1984) Acta Orthopaedica Scandinavica , vol.55 , Issue.4 , pp. 414-418
    • WRIGHT, T.M.1
  • 58
    • 0016992709 scopus 로고
    • Fracture characteristics of acrylic bone cements. Fracture toughness
    • FREITAG T.A., CANNON S.L., Fracture characteristics of acrylic bone cements. Fracture toughness, J. Biomed. Mater. Res., 1976, 10, 5, 805-828.
    • (1976) J. Biomed. Mater. Res , vol.10 , Issue.5 , pp. 805-828
    • FREITAG, T.A.1    CANNON, S.L.2
  • 59
    • 0032078538 scopus 로고    scopus 로고
    • The apparent fracture toughness of acrylic bone cement: Effect of three variables
    • LEWIS G. et al., The apparent fracture toughness of acrylic bone cement: effect of three variables, Biomaterials, 1998, 19, 10, 961-967.
    • (1998) Biomaterials , vol.19 , Issue.10 , pp. 961-967
    • LEWIS, G.1
  • 61
    • 0032947397 scopus 로고    scopus 로고
    • Effect of porosity and environment on the mechanical behavior of acrylic bone cement modified with acrylonitrile- butadiene-styrene particles
    • VILA M.M. et al., Effect of porosity and environment on the mechanical behavior of acrylic bone cement modified with acrylonitrile- butadiene-styrene particles. I. Fracture toughness, Journal of Biomedical Materials Research, 1999, 48, 2, 121-127.
    • (1999) I. Fracture toughness, Journal of Biomedical Materials Research , vol.48 , Issue.2 , pp. 121-127
    • VILA, M.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.