메뉴 건너뛰기




Volumn 18, Issue 7, 2003, Pages 637-646

Mechanical simulation of muscle loading on the proximal femur: Analysis of cemented femoral component migration with and without muscle loading

Author keywords

Femur; Inducible displacement; Migration; Pre clinical testing; Standards; Total hip arthroplasty

Indexed keywords

COMPUTER SIMULATION; FATIGUE OF MATERIALS; JOINTS (ANATOMY); MUSCLE; PHYSIOLOGY;

EID: 0043171162     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0033(03)00113-X     Document Type: Article
Times cited : (43)

References (36)
  • 1
    • 85031134387 scopus 로고    scopus 로고
    • Bergmann, G. (Ed.), 2001. Hip98, Loading of the hip joint. Published as a cd-rom attachment to the Journal of Biomechanics. ISBN 3-9807848-0-0
    • Bergmann, G. (Ed.), 2001. Hip98, Loading of the hip joint. Published as a cd-rom attachment to the Journal of Biomechanics. ISBN 3-9807848-0-0.
  • 2
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running measured in two patients
    • Bergmann G., Graichen F., Rohlmann A. Hip joint loading during walking and running measured in two patients. Journal of Biomechanics. 26:1993;969-990.
    • (1993) Journal of Biomechanics , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 4
    • 85031131652 scopus 로고    scopus 로고
    • Britton, J.R., Walsh, L.A., Prendergast, P.J., 2002. In vitro measurement of migration and inducible displacement of 4 cemented hip femoral components - results include cyclic muscle forces. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of the European Society of Biomechanics, pp. 290-291
    • Britton, J.R., Walsh, L.A., Prendergast, P.J., 2002. In vitro measurement of migration and inducible displacement of 4 cemented hip femoral components - results include cyclic muscle forces. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of the European Society of Biomechanics, pp. 290-291.
  • 5
  • 6
    • 0031408302 scopus 로고    scopus 로고
    • A critical analysis of stress shielding evaluation of hip prostheses
    • Cristofolini L. A critical analysis of stress shielding evaluation of hip prostheses. Critical Reviews in Biomedical Engineering. 25:1997;409-483.
    • (1997) Critical Reviews in Biomedical Engineering , vol.25 , pp. 409-483
    • Cristofolini, L.1
  • 11
    • 0024387836 scopus 로고
    • An investigation into the effect of cyclic loading and frequency on the temperature of PMMA bone cement in hip prostheses
    • Humphreys P.K., Orr J.F., Bahrani A.S. An investigation into the effect of cyclic loading and frequency on the temperature of PMMA bone cement in hip prostheses. Proceedings of the Institution of Mechanical Engineers: Part H. 203:1989;167-170.
    • (1989) Proceedings of the Institution of Mechanical Engineers: Part H , vol.203 , pp. 167-170
    • Humphreys, P.K.1    Orr, J.F.2    Bahrani, A.S.3
  • 13
    • 85031131771 scopus 로고    scopus 로고
    • Kärrholm, J., Nivbrant, B., Thanner, J., Anderberg, C., Borlin, N., Herberts, P., Malchau, H., 2000. Radiostereometric evaluation of hip implant design and surface finish. Technical report, Departments of Orthopaedics and Computing Science at Goteborg University and Umea University. Scientific exhibition presented at the 67th annual meeting of the American Academy of Orthopaedic Surgeons. Available from < www.jru.orthop.gu.se
    • Kärrholm, J., Nivbrant, B., Thanner, J., Anderberg, C., Borlin, N., Herberts, P., Malchau, H., 2000. Radiostereometric evaluation of hip implant design and surface finish. Technical report, Departments of Orthopaedics and Computing Science at Goteborg University and Umea University. Scientific exhibition presented at the 67th annual meeting of the American Academy of Orthopaedic Surgeons. Available from < www.jru.orthop.gu.se
  • 14
    • 85031135298 scopus 로고    scopus 로고
    • Kassi, J.P., Heller, M.O.W., Stoeckle, U., Perka, C., Duda, G.N., 2002. Muscle activity is essential for a realistic pre-clinical evaluation of primary stability in THA. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of European Society of Biomechanics, p. 47
    • Kassi, J.P., Heller, M.O.W., Stoeckle, U., Perka, C., Duda, G.N., 2002. Muscle activity is essential for a realistic pre-clinical evaluation of primary stability in THA. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of European Society of Biomechanics, p. 47.
  • 16
    • 0036171714 scopus 로고    scopus 로고
    • Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence
    • Lennon A.B., Prendergast P.J. Residual stress due to curing can initiate damage in porous bone cement: experimental and theoretical evidence. Journal of Biomechanics. 35:2002;311-321.
    • (2002) Journal of Biomechanics , vol.35 , pp. 311-321
    • Lennon, A.B.1    Prendergast, P.J.2
  • 17
    • 0031278813 scopus 로고    scopus 로고
    • Influence of muscle activity on the forces in the femur: An in vivo study
    • Lu T.W., Taylor S.T.G., O'Connor J.J., Walker P.S. Influence of muscle activity on the forces in the femur: an in vivo study. Journal of Biomechanics. 30:1997;1101-1106.
    • (1997) Journal of Biomechanics , vol.30 , pp. 1101-1106
    • Lu, T.W.1    Taylor, S.T.G.2    O'Connor, J.J.3    Walker, P.S.4
  • 18
    • 0036139769 scopus 로고    scopus 로고
    • Discriminating the loosening behaviour of cemented hip prostheses using measurements of migration and inducible displacement
    • Maher S.A., Prendergast P.J. Discriminating the loosening behaviour of cemented hip prostheses using measurements of migration and inducible displacement. Journal of Biomechanics. 35:2002;257-265.
    • (2002) Journal of Biomechanics , vol.35 , pp. 257-265
    • Maher, S.A.1    Prendergast, P.J.2
  • 19
    • 0034030695 scopus 로고    scopus 로고
    • Design and validation of a machine for reproducible precision insertion of femoral hip prostheses for preclinical testing
    • Maher S.A., Prendergast P.J., Reid A.J., Waide D.V., Toni A. Design and validation of a machine for reproducible precision insertion of femoral hip prostheses for preclinical testing. Journal of Biomechanical Engineering. 122:2000;203-207.
    • (2000) Journal of Biomechanical Engineering , vol.122 , pp. 203-207
    • Maher, S.A.1    Prendergast, P.J.2    Reid, A.J.3    Waide, D.V.4    Toni, A.5
  • 20
    • 0034999397 scopus 로고    scopus 로고
    • Measurement of the migration of a cemented hip prosthesis in an in vitro test
    • Maher S.A., Prendergast P.J., Lyons C.G. Measurement of the migration of a cemented hip prosthesis in an in vitro test. Clinical Biomechanics. 16:2001;307-314.
    • (2001) Clinical Biomechanics , vol.16 , pp. 307-314
    • Maher, S.A.1    Prendergast, P.J.2    Lyons, C.G.3
  • 21
    • 85031133081 scopus 로고    scopus 로고
    • Malchau, H., Herberts, P., Garellick, G., Söderman, P., Eisler, T., 2002. Prognosis of total hip replacement: update of results and risk-ratio analysis for revision and re-revision from the Swedish national hip arthroplasty register 1979-2000. Technical report, Department of Orthopaedics, Göteborg University, Sweden. Scientific exhibition presented at the 69th Annual Meeting of the AAOS, February, 2002, Dallas, USA. Available from < www.jru.orthop.gu.se
    • Malchau, H., Herberts, P., Garellick, G., Söderman, P., Eisler, T., 2002. Prognosis of total hip replacement: update of results and risk-ratio analysis for revision and re-revision from the Swedish national hip arthroplasty register 1979-2000. Technical report, Department of Orthopaedics, Göteborg University, Sweden. Scientific exhibition presented at the 69th Annual Meeting of the AAOS, February, 2002, Dallas, USA. Available from < www.jru.orthop.gu.se
  • 25
    • 0029347467 scopus 로고
    • Fixation and effect on bone strain pattern of a stemless hip prosthesis
    • Munting E., Verhelpen M. Fixation and effect on bone strain pattern of a stemless hip prosthesis. Journal of Biomechanics. 28:1995;949-961.
    • (1995) Journal of Biomechanics , vol.28 , pp. 949-961
    • Munting, E.1    Verhelpen, M.2
  • 26
    • 0030625937 scopus 로고    scopus 로고
    • Development of standards for orthopaedic implants
    • Paul J.P. Development of standards for orthopaedic implants. Journal of Engineering in Medicine. 211:1997;119-126.
    • (1997) Journal of Engineering in Medicine , vol.211 , pp. 119-126
    • Paul, J.P.1
  • 27
    • 0030626349 scopus 로고    scopus 로고
    • Letter to the editor re: Stress and strain distribution within the intact femur: Compression or bending? by Taylor et al
    • Paul J.P. Letter to the editor re: Stress and strain distribution within the intact femur: compression or bending? by Taylor et al. Medical Engineering and Physics. 19:1997;97.
    • (1997) Medical Engineering and Physics , vol.19 , pp. 97
    • Paul, J.P.1
  • 28
    • 0033119355 scopus 로고    scopus 로고
    • Strength requirements for internal and external prostheses
    • Paul J.P. Strength requirements for internal and external prostheses. Journal of Biomechanics. 32:1999;381-393.
    • (1999) Journal of Biomechanics , vol.32 , pp. 381-393
    • Paul, J.P.1
  • 29
    • 0003632299 scopus 로고
    • (P. Maquet, R. Furlong, Trans.). Berlin, Germany: Springer-Verlag
    • Pauwels F. Biomechanics of the Locomotor Apparatus. (P. Maquet, R. Furlong, Trans.):1980;Springer-Verlag, Berlin, Germany.
    • (1980) Biomechanics of the Locomotor Apparatus
    • Pauwels, F.1
  • 30
    • 85031132582 scopus 로고    scopus 로고
    • Polgar, K., Gill, H.S., Murray, D.W., O'Connor, J.J., 2002. Simulation of physiological muscle loading in finite element modelling of the intact femur. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of European Society of Biomechanics, pp. 129-130
    • Polgar, K., Gill, H.S., Murray, D.W., O'Connor, J.J., 2002. Simulation of physiological muscle loading in finite element modelling of the intact femur. In: Bedziński, R., Pezowicz, C., Ścigala, K. (Eds.), Acta of Bioengineering and Biomechanics: Proceedings of the 13th conference of European Society of Biomechanics, pp. 129-130.
  • 31
    • 0034989298 scopus 로고    scopus 로고
    • Hip-joint and abductor muscle forces adequately represent in vivo loading of a cemented total hip reconstruction
    • Stolk J., Verdonschot N., Huiskes R. Hip-joint and abductor muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. Journal of Biomechanics. 34:2001;917-926.
    • (2001) Journal of Biomechanics , vol.34 , pp. 917-926
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 32
    • 0012054912 scopus 로고
    • Variability in the torsional and bending response of a commercially available composite femur
    • Szivek J.A., Weng M., Karpman R. Variability in the torsional and bending response of a commercially available composite femur. Journal of Applied Biomaterials. 1:1990;183-186.
    • (1990) Journal of Applied Biomaterials , vol.1 , pp. 183-186
    • Szivek, J.A.1    Weng, M.2    Karpman, R.3
  • 33
    • 0034163705 scopus 로고    scopus 로고
    • An experimental method for the application of lateral muscle loading and its effect on femoral strain distribution
    • Szivek J.A., Benjamin J.B., Anderson P.L. An experimental method for the application of lateral muscle loading and its effect on femoral strain distribution. Medical Engineering and Physics. 22:2000;109-116.
    • (2000) Medical Engineering and Physics , vol.22 , pp. 109-116
    • Szivek, J.A.1    Benjamin, J.B.2    Anderson, P.L.3
  • 34
    • 0028501857 scopus 로고
    • Creep behaviour of hand-mixed Simplex P bone cement under cyclic tensile loading
    • Verdonschot N., Huiskes R. Creep behaviour of hand-mixed Simplex. P bone cement under cyclic tensile loading Journal of Applied Biomaterials. 5:1994;235-243.
    • (1994) Journal of Applied Biomaterials , vol.5 , pp. 235-243
    • Verdonschot, N.1    Huiskes, R.2
  • 35
    • 0029135432 scopus 로고
    • Prediction of clinical outcome of THR from migration measurements on standard radiographs
    • Walker P.S., Mai S.F., Cobb A.G., Bentley G., Hua J. Prediction of clinical outcome of THR from migration measurements on standard radiographs. Journal of Bone and Joint Surgery. 77B:1995;705-714.
    • (1995) Journal of Bone and Joint Surgery , vol.77 , pp. 705-714
    • Walker, P.S.1    Mai, S.F.2    Cobb, A.G.3    Bentley, G.4    Hua, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.