메뉴 건너뛰기




Volumn 29, Issue 12, 1996, Pages 1569-1575

Subsidence of THA stems due to acrylic cement creep is extremely sensitive to interface friction

Author keywords

Acrylic cement; Creep; Subsidence; Total hip arthroplasty

Indexed keywords

ACRYLICS; BONE CEMENT; CREEP; DYNAMIC LOADS; FINITE ELEMENT METHOD; FRICTION; INTERFACES (MATERIALS); MATHEMATICAL MODELS; SUBSIDENCE; SURFACE ROUGHNESS; SURGERY;

EID: 0030561029     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(96)80008-X     Document Type: Article
Times cited : (52)

References (18)
  • 1
    • 0020093517 scopus 로고
    • Transient and residual stresses in self curing bone cement. Part II: Thermoelastic analysis of the stem fixation system
    • Ahmed, A. M., Nair, R., Burke, E. L. and Miller, J. E. (1982) Transient and residual stresses in self curing bone cement. Part II: Thermoelastic analysis of the stem fixation system. J. Biomech. Engng 104, 28-37.
    • (1982) J. Biomech. Engng , vol.104 , pp. 28-37
    • Ahmed, A.M.1    Nair, R.2    Burke, E.L.3    Miller, J.E.4
  • 2
    • 0021361757 scopus 로고
    • Long-term compressive creep deformation and damage in acrylic bone elements
    • Chwirut, D. J. (1984) Long-term compressive creep deformation and damage in acrylic bone elements. J. Biomed. Mater. Res. 18, 25-37.
    • (1984) J. Biomed. Mater. Res. , vol.18 , pp. 25-37
    • Chwirut, D.J.1
  • 5
    • 0026438865 scopus 로고
    • Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacement?
    • Harris, W. H. (1992) Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacement? Clin. Orthop. 285, 67-72.
    • (1992) Clin. Orthop. , vol.285 , pp. 67-72
    • Harris, W.H.1
  • 7
    • 0027535641 scopus 로고
    • Extensive porosity at the cement-femoral prosthesis interface: A preliminary study
    • James, S. P., Schmalzried, T. P., McGary, F. J. and Harris, W. H. (1993) Extensive porosity at the cement-femoral prosthesis interface: a preliminary study. J. Biomed. Mater. Res. 27, 71-78.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 71-78
    • James, S.P.1    Schmalzried, T.P.2    McGary, F.J.3    Harris, W.H.4
  • 8
    • 0001891466 scopus 로고
    • Time-dependent properties of polymethylmethacrylate bone cement
    • Edited by Older, J., Ch. 12, Springer, Berlin
    • Lee, A. J. C., Perkins, R. D. and Ling, R. S. M. (1990) Time-dependent properties of polymethylmethacrylate bone cement. In Implant Bone Interface (Edited by Older, J.), Ch. 12, pp. 85-90. Springer, Berlin.
    • (1990) Implant Bone Interface , pp. 85-90
    • Lee, A.J.C.1    Perkins, R.D.2    Ling, R.S.M.3
  • 9
    • 0026452452 scopus 로고
    • The use of a collar and precoating on cemented femoral stems is unnecessary and detrimental
    • Ling, R. S. M. (1992) The use of a collar and precoating on cemented femoral stems is unnecessary and detrimental. Clin. Orthop. 285, 73-82.
    • (1992) Clin. Orthop. , vol.285 , pp. 73-82
    • Ling, R.S.M.1
  • 11
    • 0024694991 scopus 로고
    • Creep studies of multiphase acrylic systems
    • Oysæed, H. and Ruyter, I. E. (1989) Creep studies of multiphase acrylic systems. J. Biomed. Mater. Res. 23, 719-733.
    • (1989) J. Biomed. Mater. Res. , vol.23 , pp. 719-733
    • Oysæed, H.1    Ruyter, I.E.2
  • 12
    • 0019991224 scopus 로고
    • Stress relaxation and creep behavior of normal and carbon fibre reinforced acrylic bone cement
    • Saha, S. and Pal, S. (1982) Stress relaxation and creep behavior of normal and carbon fibre reinforced acrylic bone cement. Biomaterials 3, 93-96.
    • (1982) Biomaterials , vol.3 , pp. 93-96
    • Saha, S.1    Pal, S.2
  • 13
    • 0021412468 scopus 로고
    • Mechanical properties of bone cement: A review
    • Saha, S. and Pal, S. (1984) Mechanical properties of bone cement: a review. J. Biomed. Mater. Res. 18, 435-462.
    • (1984) J. Biomed. Mater. Res. , vol.18 , pp. 435-462
    • Saha, S.1    Pal, S.2
  • 14
    • 0016532159 scopus 로고
    • Factors influencing the creep behavior of poly(methyl methacrylate) cements
    • Treharne, R. W. and Brown, N. (1975) Factors influencing the creep behavior of poly(methyl methacrylate) cements. J. Biomed. Mater. Res. 6, 81-88.
    • (1975) J. Biomed. Mater. Res. , vol.6 , pp. 81-88
    • Treharne, R.W.1    Brown, N.2
  • 15
    • 0028501857 scopus 로고
    • The creep behavior of hand-mixed Simplex P bone cement under cyclic tensile loading
    • Verdonschot, N. and Huiskes, R. (1994) The creep behavior of hand-mixed Simplex P bone cement under cyclic tensile loading. J. Appl. Biomater. 5, 235-243.
    • (1994) J. Appl. Biomater. , vol.5 , pp. 235-243
    • Verdonschot, N.1    Huiskes, R.2
  • 16
    • 0029038282 scopus 로고
    • Dynamic creep behavior of acrylic bone cement
    • Verdonschot, N. and Huiskes, R. (1995a) Dynamic creep behavior of acrylic bone cement. J. Biomed. Mater. Res. 29, 575-581.
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 575-581
    • Verdonschot, N.1    Huiskes, R.2
  • 17
    • 0011872912 scopus 로고
    • The effect of stem-cement interface characteristics on the survival of femoral THR
    • in press
    • Verdonschot, N. and Huiskes, R. (1995b) The effect of stem-cement interface characteristics on the survival of femoral THR. Clin. Orthop. Rel. Res. (in press).
    • (1995) Clin. Orthop. Rel. Res.
    • Verdonschot, N.1    Huiskes, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.