Volumn 21, Issue 2, 2008, Pages 297-304

Prediction and evaluation of cleanliness levels inside a mini-environment by measuring mean air-age and effective flow rate

Author keywords

Cleanliness level; Cleanroom; Mean air age; Mini environment

Indexed keywords

AIR POLLUTION; FLOW MEASUREMENT; FLOW RATE; NUMERICAL METHODS;

EID: 43849103963     PISSN: 08946507     EISSN: None     Source Type: Journal    
DOI: 10.1109/TSM.2008.2000271     Document Type: Conference Paper
Times cited : (6)

References (16)
  • 1
    • 34249788555 scopus 로고    scopus 로고
    • A trend of giga level cleanroom technology
    • Clean Technology and Management for Indoor Air, Korea Ait-Cleaning Association
    • M. D. Oh, "A trend of giga level cleanroom technology," in Proc. Int. Symp. Clean Technology and Management for Indoor Air, Korea Ait-Cleaning Association, 2002, pp. 17-62.
    • (2002) Proc. Int. Symp , pp. 17-62
    • Oh, M.D.1
  • 5
    • 0037330811 scopus 로고    scopus 로고
    • Numerical simulation for air flow in mini-environment and SMIF enclosure
    • H. R. Shiu, H. Y. Huang, S. L. Chen, and M. T. Ke, "Numerical simulation for air flow in mini-environment and SMIF enclosure," IEEE Trans. Semiconduct. Manuf., vol. 16, pp. 60-67, 2003.
    • (2003) IEEE Trans. Semiconduct. Manuf , vol.16 , pp. 60-67
    • Shiu, H.R.1    Huang, H.Y.2    Chen, S.L.3    Ke, M.T.4
  • 6
    • 0344896827 scopus 로고    scopus 로고
    • Experimental study of airflow and particle characteristics of a 300-mm FOUP/LPU minienvironment system
    • S. C. Hu and T. M. Wu, "Experimental study of airflow and particle characteristics of a 300-mm FOUP/LPU minienvironment system," IEEE Trans. Semiconduct. Manuf., vol. 16, pp. 660-667, 2003.
    • (2003) IEEE Trans. Semiconduct. Manuf , vol.16 , pp. 660-667
    • Hu, S.C.1    Wu, T.M.2
  • 7
    • 0036467508 scopus 로고    scopus 로고
    • Design and evaluation of a minienvironment for semiconductor manufacture process
    • S. C. Hu, Y. K. Chuah, and M. C. Yen, "Design and evaluation of a minienvironment for semiconductor manufacture process," Build. Environ., vol. 37, pp. 201-208, 2002.
    • (2002) Build. Environ , vol.37 , pp. 201-208
    • Hu, S.C.1    Chuah, Y.K.2    Yen, M.C.3
  • 8
    • 0033992189 scopus 로고    scopus 로고
    • Simultaneous control of particle contaminants and VOC pollution under different operating conditions of a mini-environment that contains a coating process
    • Y. K. Chuah, C. H. Tasi, and S. C. Hu, "Simultaneous control of particle contaminants and VOC pollution under different operating conditions of a mini-environment that contains a coating process," Build. Environ., vol. 35, pp. 91-99, 2000.
    • (2000) Build. Environ , vol.35 , pp. 91-99
    • Chuah, Y.K.1    Tasi, C.H.2    Hu, S.C.3
  • 9
    • 33947578109 scopus 로고    scopus 로고
    • Characterization of minienvironments in a clean room: Design characteristics and environmental performance
    • T. Xu, "Characterization of minienvironments in a clean room: Design characteristics and environmental performance," Build. Environ., vol. 42, pp. 2993-3000, 2007.
    • (2007) Build. Environ , vol.42 , pp. 2993-3000
    • Xu, T.1
  • 10
    • 33947610784 scopus 로고    scopus 로고
    • A study on the operation performance of a minienvironment system
    • T. Xu, "A study on the operation performance of a minienvironment system," J. IEST, vol. 49, pp. 63-71, 2006.
    • (2006) J. IEST , vol.49 , pp. 63-71
    • Xu, T.1
  • 11
    • 0020944408 scopus 로고
    • Ventilation efficiency as a guide to design
    • M. Sandberg, "Ventilation efficiency as a guide to design," ASHRAE Trans., vol. 89, pp. 455-479, 1983.
    • (1983) ASHRAE Trans , vol.89 , pp. 455-479
    • Sandberg, M.1
  • 12
    • 34249813254 scopus 로고    scopus 로고
    • Numerical analysis of local exhaust effectiveness using reverse-flow calculation method
    • H. T. Han, "Numerical analysis of local exhaust effectiveness using reverse-flow calculation method," J. SAREK, vol. 10, pp. 658-665, 1998.
    • (1998) J. SAREK , vol.10 , pp. 658-665
    • Han, H.T.1
  • 13
    • 34249789422 scopus 로고
    • Analysis of 3-Dimensional Flow Characteristics in a Clean Room With Low Pressure Drop Filter Installation,
    • Ph.D. dissertation, Hanyang Univ, Seoul, Korea
    • M. S. Park, "Analysis of 3-Dimensional Flow Characteristics in a Clean Room With Low Pressure Drop Filter Installation," Ph.D. dissertation, Hanyang Univ., Seoul, Korea, 1993.
    • (1993)
    • Park, M.S.1
  • 14
    • 34249818317 scopus 로고    scopus 로고
    • A numerical analysis on the airflow characteristics in super cleanrooms with different design types
    • K. C. Noh, S. C. Lee, and M. D. Oh, "A numerical analysis on the airflow characteristics in super cleanrooms with different design types," J. SAREK, vol. 15, pp. 751-761, 2003.
    • (2003) J. SAREK , vol.15 , pp. 751-761
    • Noh, K.C.1    Lee, S.C.2    Oh, M.D.3