메뉴 건너뛰기




Volumn 35, Issue 6, 2008, Pages 454-474

The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: A critical review on accuracy

Author keywords

CT based planning; Oral implant; Surgical guide; Transfer

Indexed keywords

COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; HUMAN; MOUTH; PATIENT CARE PLANNING; RADIOGRAPHY; REVIEW; THREE DIMENSIONAL IMAGING; TOOTH DISEASE; TOOTH IMPLANTATION;

EID: 43049114556     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2007.01816.x     Document Type: Review
Times cited : (143)

References (75)
  • 1
    • 0036984765 scopus 로고    scopus 로고
    • Imaging technique selection for the preoperative planning of oral implants: A review of the literature
    • (review).
    • Bou Serhal C, Jacobs R, Quirynen M, van Steenberghe D. Imaging technique selection for the preoperative planning of oral implants: a review of the literature. Clin Implant Dent Relat Res. 2002 4 : 156 172 (review).
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 156-172
    • Bou Serhal, C.1    Jacobs, R.2    Quirynen, M.3    Van Steenberghe, D.4
  • 2
    • 0029340209 scopus 로고
    • Predicting esthetics in implant dentistry using multiplanar angulation: A technical note
    • Sethi A, Sochor P. Predicting esthetics in implant dentistry using multiplanar angulation: a technical note. Int J Oral Maxillofac Implants. 1995 10 : 485 490.
    • (1995) Int J Oral Maxillofac Implants. , vol.10 , pp. 485-490
    • Sethi, A.1    Sochor, P.2
  • 3
    • 33645235271 scopus 로고    scopus 로고
    • Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning
    • Loubele M, Jacobs R, Maes F, Schutyser F, Debaveye D, Bogaerts R et al. Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning. Radiat Prot Dosimetry. 2005 117 : 211 216.
    • (2005) Radiat Prot Dosimetry. , vol.117 , pp. 211-216
    • Loubele, M.1    Jacobs, R.2    Maes, F.3    Schutyser, F.4    Debaveye, D.5    Bogaerts, R.6
  • 4
    • 0344530444 scopus 로고    scopus 로고
    • Variations in radiation dose between the same model of multislice CT scanner at different hospitals
    • Koller CJ, Eatough JP, Bettridge A. Variations in radiation dose between the same model of multislice CT scanner at different hospitals. Br J Radiol. 2003 76 : 798 802.
    • (2003) Br J Radiol. , vol.76 , pp. 798-802
    • Koller, C.J.1    Eatough, J.P.2    Bettridge, A.3
  • 6
    • 0034195222 scopus 로고    scopus 로고
    • A modular software system for computer-aided surgery and its first application in oral implantology
    • Birkfellner W, Huber K, Larson A, Hanson D, Diemling M, Homolka P et al. A modular software system for computer-aided surgery and its first application in oral implantology. IEEE Trans Med Imaging. 2000 19 : 616 620.
    • (2000) IEEE Trans Med Imaging. , vol.19 , pp. 616-620
    • Birkfellner, W.1    Huber, K.2    Larson, A.3    Hanson, D.4    Diemling, M.5    Homolka, P.6
  • 8
    • 0034584826 scopus 로고    scopus 로고
    • Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques
    • Fortin T, Champleboux G, Lormee J, Coudert JL. Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. J Oral Implantol. 2000 26 : 300 303.
    • (2000) J Oral Implantol. , vol.26 , pp. 300-303
    • Fortin, T.1    Champleboux, G.2    Lormee, J.3    Coudert, J.L.4
  • 9
    • 0035290222 scopus 로고    scopus 로고
    • Computer-guided surgery utilizing a computer-milled surgical template
    • quiz 170.
    • Klein M, Abrams M. Computer-guided surgery utilizing a computer-milled surgical template. Pract Proced Aesthet Dent. 2001 13 : 165 169 quiz 170.
    • (2001) Pract Proced Aesthet Dent. , vol.13 , pp. 165-169
    • Klein, M.1    Abrams, M.2
  • 10
    • 33744803207 scopus 로고    scopus 로고
    • Cone beam computerized tomography-based dental imaging for implant planning and surgical guidance, Part 1: Single implant in the mandibular molar region
    • Almog DM, LaMar J, LaMar FR, LaMar F. Cone beam computerized tomography-based dental imaging for implant planning and surgical guidance, Part 1: single implant in the mandibular molar region. J Oral Implantol. 2006 32 : 77 81.
    • (2006) J Oral Implantol. , vol.32 , pp. 77-81
    • Almog, D.M.1    Lamar, J.2    Lamar, F.R.3    Lamar, F.4
  • 11
    • 0038405208 scopus 로고    scopus 로고
    • Evaluation of accuracy of insertion of dental implants and prosthetic treatment by computer-aided navigation in minipigs
    • Meyer U, Wiesmann HP, Runte C, Fillies T, Meier N, Lueth T et al. Evaluation of accuracy of insertion of dental implants and prosthetic treatment by computer-aided navigation in minipigs. Br J Oral Maxillofac Surg. 2003 41 : 102 108.
    • (2003) Br J Oral Maxillofac Surg. , vol.41 , pp. 102-108
    • Meyer, U.1    Wiesmann, H.P.2    Runte, C.3    Fillies, T.4    Meier, N.5    Lueth, T.6
  • 13
    • 0037292270 scopus 로고    scopus 로고
    • Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study
    • Vrielinck L, Politis C, Schepers S, Pauwels M, Naert I. Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. Int J Oral Maxillofac Surg. 2003 32 : 7 14.
    • (2003) Int J Oral Maxillofac Surg. , vol.32 , pp. 7-14
    • Vrielinck, L.1    Politis, C.2    Schepers, S.3    Pauwels, M.4    Naert, I.5
  • 17
    • 0026145458 scopus 로고
    • Radiologic-prosthetic planning of the surgical phase of the treatment of edentulism by osseointegrated implants: An in vitro study
    • Modica F, Fava C, Benech A, Preti G. Radiologic-prosthetic planning of the surgical phase of the treatment of edentulism by osseointegrated implants: an in vitro study. J Prosthet Dent. 1991 65 : 541 546.
    • (1991) J Prosthet Dent. , vol.65 , pp. 541-546
    • Modica, F.1    Fava, C.2    Benech, A.3    Preti, G.4
  • 18
    • 0026468720 scopus 로고
    • Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients
    • Israelson H, Plemons JM, Watkins P, Sory C. Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. Int J Periodontics Restorative Dent. 1992 12 : 53 61.
    • (1992) Int J Periodontics Restorative Dent. , vol.12 , pp. 53-61
    • Israelson, H.1    Plemons, J.M.2    Watkins, P.3    Sory, C.4
  • 19
    • 0027640527 scopus 로고
    • A computerized tomography (CT) scan appliance for optimal presurgical and preprosthetic planning of the implant patient
    • quiz 39.
    • Klein M, Cranin AN, Sirakian A. A computerized tomography (CT) scan appliance for optimal presurgical and preprosthetic planning of the implant patient. Pract Periodontics Aesthet Dent. 1993 5 : 33 39 quiz 39.
    • (1993) Pract Periodontics Aesthet Dent. , vol.5 , pp. 33-39
    • Klein, M.1    Cranin, A.N.2    Sirakian, A.3
  • 20
    • 0027564197 scopus 로고
    • A dual-purpose stent for the implant-supported prosthesis
    • Verde MA, Morgano MS. A dual-purpose stent for the implant-supported prosthesis. J Prosthet Dent. 1993 69 : 276 280.
    • (1993) J Prosthet Dent. , vol.69 , pp. 276-280
    • Verde, M.A.1    Morgano, M.S.2
  • 21
    • 0029364177 scopus 로고
    • The use of radiopaque templates for predictable implant placement
    • Basten CH. The use of radiopaque templates for predictable implant placement. Quintessence Int. 1995 26 : 609 612.
    • (1995) Quintessence Int. , vol.26 , pp. 609-612
    • Basten, C.H.1
  • 22
    • 0030254328 scopus 로고    scopus 로고
    • The use of barium sulfate for implant templates
    • Basten CH, Kois JC. The use of barium sulfate for implant templates. J Prosthet Dent. 1996 76 : 451 454.
    • (1996) J Prosthet Dent. , vol.76 , pp. 451-454
    • Basten, C.H.1    Kois, J.C.2
  • 23
    • 0029311631 scopus 로고
    • Fabrication of a guide for radiographic evaluation and surgical placements of implants
    • Pesun IJ, Gardner FM. Fabrication of a guide for radiographic evaluation and surgical placements of implants. J Prosthet Dent. 1995 73 : 548 552.
    • (1995) J Prosthet Dent. , vol.73 , pp. 548-552
    • Pesun, I.J.1    Gardner, F.M.2
  • 24
    • 0031218037 scopus 로고    scopus 로고
    • Implant treatment planning using a patient acceptance prothesis, radiographic record base, and surgical template. Part 1: Presurgical phase
    • Amet ME, Ganz SD. Implant treatment planning using a patient acceptance prothesis, radiographic record base, and surgical template. Part 1: presurgical phase. Implant Dent. 1997 6 : 193 197.
    • (1997) Implant Dent. , vol.6 , pp. 193-197
    • Amet, M.E.1    Ganz, S.D.2
  • 25
    • 0032134047 scopus 로고    scopus 로고
    • Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement
    • quiz 766.
    • Mizrahi B, Thunthy KH, Finger I. Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement. Pract Periodontics Aesthet Dent. 1998 10 : 757 765 quiz 766.
    • (1998) Pract Periodontics Aesthet Dent. , vol.10 , pp. 757-765
    • Mizrahi, B.1    Thunthy, K.H.2    Finger, I.3
  • 26
    • 0031602297 scopus 로고    scopus 로고
    • Three-dimensional guidance system for implant insertion: Part I
    • Weinberg LA, Kruger B. Three-dimensional guidance system for implant insertion: part I. Implant Dent. 1998 7 : 81 93.
    • (1998) Implant Dent. , vol.7 , pp. 81-93
    • Weinberg, L.A.1    Kruger, B.2
  • 27
    • 0033252406 scopus 로고    scopus 로고
    • Three-dimensional guidance system for implant insertion: Part II. dual axes table-problem solving
    • Weinberg LA, Kruger B. Three-dimensional guidance system for implant insertion: part II. dual axes table-problem solving. Implant Dent. 1999 8 : 255 262.
    • (1999) Implant Dent. , vol.8 , pp. 255-262
    • Weinberg, L.A.1    Kruger, B.2
  • 28
    • 0033742261 scopus 로고    scopus 로고
    • Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography
    • Besimo CE, Lambrecht JT, Guindy JS. Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. Dentomaxillofac Radiol. 2000 29 : 46 51.
    • (2000) Dentomaxillofac Radiol. , vol.29 , pp. 46-51
    • Besimo, C.E.1    Lambrecht, J.T.2    Guindy, J.S.3
  • 29
    • 0034218952 scopus 로고    scopus 로고
    • Bilaminar dual-purpose stent for placement of dental implants
    • Çehreli MC, Aslan Y, Sahin S. Bilaminar dual-purpose stent for placement of dental implants. J Prosthet Dent. 2000 84 : 55 58.
    • (2000) J Prosthet Dent. , vol.84 , pp. 55-58
    • Çehreli, M.C.1    Aslan, Y.2    Sahin, S.3
  • 30
    • 0034208781 scopus 로고    scopus 로고
    • Predetermined implant positioning by, means of a novel guide template technique
    • Minoretti R, Merz BR, Triaca A. Predetermined implant positioning by, means of a novel guide template technique. Clin Oral Implants Res. 2000 11 : 266 272.
    • (2000) Clin Oral Implants Res. , vol.11 , pp. 266-272
    • Minoretti, R.1    Merz, B.R.2    Triaca, A.3
  • 31
    • 0034305454 scopus 로고    scopus 로고
    • Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants?
    • Naitoh M, Ariji E, Okumura S, Ohsaki C, Kurita K, Ishigami T. Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? Clin Oral Implants Res. 2000 11 : 409 414.
    • (2000) Clin Oral Implants Res. , vol.11 , pp. 409-414
    • Naitoh, M.1    Ariji, E.2    Okumura, S.3    Ohsaki, C.4    Kurita, K.5    Ishigami, T.6
  • 33
    • 0036513384 scopus 로고    scopus 로고
    • Surgical oral radiographic guide with a removable component for implant placement
    • Shahrasbi AH, Hansen CA. Surgical oral radiographic guide with a removable component for implant placement. J Prosthet Dent. 2002 87 : 330 332.
    • (2002) J Prosthet Dent. , vol.87 , pp. 330-332
    • Shahrasbi, A.H.1    Hansen, C.A.2
  • 34
    • 0036559364 scopus 로고    scopus 로고
    • Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. a technical note on the screw-retained type: Part 1
    • Tomotake Y, Ishida O, Kanitani H, Ichikawa T. Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. A technical note on the screw-retained type: part 1. Int J Prosthodont. 2002 15 : 303 306.
    • (2002) Int J Prosthodont. , vol.15 , pp. 303-306
    • Tomotake, Y.1    Ishida, O.2    Kanitani, H.3    Ichikawa, T.4
  • 35
    • 0036367728 scopus 로고    scopus 로고
    • Precision surgical template for implant placement: A new systematic approach
    • Wat PY, Chow TW, Luk HW, Comfort MB. Precision surgical template for implant placement: a new systematic approach. Clin Implant Dent Relat Res. 2002 4 : 88 92.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 88-92
    • Wat, P.Y.1    Chow, T.W.2    Luk, H.W.3    Comfort, M.B.4
  • 36
    • 0141575639 scopus 로고    scopus 로고
    • Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging
    • Kopp KC, Koslow AH, Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent. 2003 89 : 611 5.
    • (2003) J Prosthet Dent. , vol.89 , pp. 611-5
    • Kopp, K.C.1    Koslow, A.H.2    Abdo, O.S.3
  • 40
    • 0344428714 scopus 로고    scopus 로고
    • An image-guided planning system for oral implants surgery
    • In: Proceedings of the International Symposium on Computer and Communication Systems for Image Guided Diagnosis and Therapy
    • Verstreken K, Van Cleynenbreugel J, Marchal G, Suetens P, van Steenberghe D. An image-guided planning system for oral implants surgery. In : Computer assisted radiolog. Proceedings of the International Symposium on Computer and Communication Systems for Image Guided Diagnosis and Therapy 1996.
    • (1996) Computer Assisted Radiolog.
    • Verstreken, K.1    Van Cleynenbreugel, J.2    Marchal, G.3    Suetens, P.4    Van Steenberghe, D.5
  • 43
    • 0037946955 scopus 로고    scopus 로고
    • Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers
    • van Steenberghe D, Malevez C, Van Cleynenbreugel J, Serhal CB, Dhoore E, Schutyser F et al. Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. Clin Oral Implants Res. 2003 14 : 131 136.
    • (2003) Clin Oral Implants Res. , vol.14 , pp. 131-136
    • Van Steenberghe, D.1    Malevez, C.2    Van Cleynenbreugel, J.3    Serhal, C.B.4    Dhoore, E.5    Schutyser, F.6
  • 45
    • 20744446711 scopus 로고    scopus 로고
    • A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study
    • van Steenberghe D, Glauser R, Blomback U, Andersson M. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res. 2005 7 (Suppl. 1 S111 S120.
    • (2005) Clin Implant Dent Relat Res. , vol.7 , Issue.1
    • Van Steenberghe, D.1    Glauser, R.2    Blomback, U.3    Andersson, M.4
  • 46
    • 1342285090 scopus 로고    scopus 로고
    • The use of a custom template for immediate loading with the definitive prosthesis: A clinical report
    • Marchack CB, Moy PK. The use of a custom template for immediate loading with the definitive prosthesis: a clinical report. J Calif Dent Assoc. 2003 31 : 925 929.
    • (2003) J Calif Dent Assoc. , vol.31 , pp. 925-929
    • Marchack, C.B.1    Moy, P.K.2
  • 47
    • 11144240533 scopus 로고    scopus 로고
    • An immediately loaded CAD/CAM-guided definitive prosthesis: A clinical report
    • Marchack CB. An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report. J Prosthet Dent. 2005 93 : 8 12.
    • (2005) J Prosthet Dent. , vol.93 , pp. 8-12
    • Marchack, C.B.1
  • 48
    • 4644317251 scopus 로고    scopus 로고
    • Interactive imaging for implant planning, placement, and prosthesis construction. American Association of Oral and Maxillofacial Surgeons
    • Parel SM, Triplett RG. Interactive imaging for implant planning, placement, and prosthesis construction. American Association of Oral and Maxillofacial Surgeons. J Oral Maxillofac Surg. 2004 62 : 41 47.
    • (2004) J Oral Maxillofac Surg. , vol.62 , pp. 41-47
    • Parel, S.M.1    Triplett, R.G.2
  • 49
    • 33644616085 scopus 로고    scopus 로고
    • Three-dimensional software for fabrication of a surgical template and final implant-supported restoration for a fully edentulous maxilla: A case report
    • 804-807
    • Becker W, Doerr J. Three-dimensional software for fabrication of a surgical template and final implant-supported restoration for a fully edentulous maxilla: a case report. Compend Contin Educ Dent. 2005 26 : 802, 804 807.
    • (2005) Compend Contin Educ Dent. , vol.26 , pp. 802
    • Becker, W.1    Doerr, J.2
  • 50
    • 33745394071 scopus 로고    scopus 로고
    • Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region
    • Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region. Int J Periodontics Restorative Dent. 2006 26 : 239 247.
    • (2006) Int J Periodontics Restorative Dent. , vol.26 , pp. 239-247
    • Balshi, S.F.1    Wolfinger, G.J.2    Balshi, T.J.3
  • 51
    • 33847619608 scopus 로고    scopus 로고
    • Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the internet for immediate loading of dental implants
    • Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the internet for immediate loading of dental implants. J Esthet Restor Dent. 2006 18 : 312 323.
    • (2006) J Esthet Restor Dent. , vol.18 , pp. 312-323
    • Balshi, S.F.1    Wolfinger, G.J.2    Balshi, T.J.3
  • 52
    • 33748945018 scopus 로고    scopus 로고
    • Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: A case report
    • Kupeyan HK, Shaffner M, Armstrong J. Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report. Clin Implant Dent Relat Res. 2006 8 : 161 167.
    • (2006) Clin Implant Dent Relat Res. , vol.8 , pp. 161-167
    • Kupeyan, H.K.1    Shaffner, M.2    Armstrong, J.3
  • 53
    • 0348048836 scopus 로고    scopus 로고
    • Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: An in vivo study
    • Fortin T, Bosson JL, Coudert JL, Isidori M. Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. Int J Oral Maxillofac Implants. 2003 18 : 886 893.
    • (2003) Int J Oral Maxillofac Implants. , vol.18 , pp. 886-893
    • Fortin, T.1    Bosson, J.L.2    Coudert, J.L.3    Isidori, M.4
  • 54
    • 8344263850 scopus 로고    scopus 로고
    • An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: A clinical report on immediate loading
    • Fortin T, Isidori M, Blanchet E, Perriat M, Bouchet H, Coudert JL. An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. Clin Implant Dent Relat Res. 2004 6 : 111 119.
    • (2004) Clin Implant Dent Relat Res. , vol.6 , pp. 111-119
    • Fortin, T.1    Isidori, M.2    Blanchet, E.3    Perriat, M.4    Bouchet, H.5    Coudert, J.L.6
  • 57
    • 0041510493 scopus 로고    scopus 로고
    • Stereolithographic surgical templates for placement of dental implants in complex cases
    • Sarment DP, Al-Shammari K, Kazor CE. Stereolithographic surgical templates for placement of dental implants in complex cases. Int J Periodontics Restorative Dent. 2003 23 : 287 295.
    • (2003) Int J Periodontics Restorative Dent. , vol.23 , pp. 287-295
    • Sarment, D.P.1    Al-Shammari, K.2    Kazor, C.E.3
  • 58
    • 1442278453 scopus 로고    scopus 로고
    • Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants
    • Ganz SD. Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants. Pract Proced Aesthet dent. 2003 15 : 763 771.
    • (2003) Pract Proced Aesthet Dent. , vol.15 , pp. 763-771
    • Ganz, S.D.1
  • 59
    • 0141608169 scopus 로고    scopus 로고
    • Computer-assisted implant placement. a case report: Treatment of the mandible
    • Tardieu PB, Vrielinck L, Escolano E. Computer-assisted implant placement. A case report: treatment of the mandible. Int J Oral Maxillofac Implants. 2003 18 : 599 604.
    • (2003) Int J Oral Maxillofac Implants. , vol.18 , pp. 599-604
    • Tardieu, P.B.1    Vrielinck, L.2    Escolano, E.3
  • 60
    • 19044400459 scopus 로고    scopus 로고
    • Clinical application of stereolithographic surgical guides for implant placement: Preliminary results
    • Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol. 2005 76 : 503 507.
    • (2005) J Periodontol. , vol.76 , pp. 503-507
    • Di Giacomo, G.A.1    Cury, P.R.2    De Araujo, N.S.3    Sendyk, W.R.4    Sendyk, C.L.5
  • 61
    • 23944440357 scopus 로고    scopus 로고
    • Presurgical planning with CT-derived fabrication of surgical guides
    • Ganz SD. Presurgical planning with CT-derived fabrication of surgical guides. J Oral Maxillofac Surg. 2005 63 : 59 71.
    • (2005) J Oral Maxillofac Surg. , vol.63 , pp. 59-71
    • Ganz, S.D.1
  • 62
    • 33644645128 scopus 로고    scopus 로고
    • Techniques for the use of CT imaging for the fabrication of surgical guides
    • Ganz SD. Techniques for the use of CT imaging for the fabrication of surgical guides. Atlas Oral Maxillofac Surg Clin North Am. 2006 14 : 75 97.
    • (2006) Atlas Oral Maxillofac Surg Clin North Am. , vol.14 , pp. 75-97
    • Ganz, S.D.1
  • 63
    • 19744377979 scopus 로고    scopus 로고
    • Computer-guided implant placement with immediate provisionalization: A case report
    • Sudbrink SD. Computer-guided implant placement with immediate provisionalization: a case report. J Oral Maxillofac Surg. 2005 63 : 771 774.
    • (2005) J Oral Maxillofac Surg. , vol.63 , pp. 771-774
    • Sudbrink, S.D.1
  • 64
    • 33645164549 scopus 로고    scopus 로고
    • Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. the Concept
    • Lal K, White GS, Morea DN, Wright RF. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The Concept. J Prosthodont. 2006 15 : 51 58.
    • (2006) J Prosthodont. , vol.15 , pp. 51-58
    • Lal, K.1    White, G.S.2    Morea, D.N.3    Wright, R.F.4
  • 65
    • 33645963125 scopus 로고    scopus 로고
    • Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. a clinical report
    • Lal K, White GS, Morea DN, Wright RF. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. J Prosthodont. 2006 15 : 117 122.
    • (2006) J Prosthodont. , vol.15 , pp. 117-122
    • Lal, K.1    White, G.S.2    Morea, D.N.3    Wright, R.F.4
  • 66
    • 33747109599 scopus 로고    scopus 로고
    • Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: Rapid-prototype medical modeling
    • Rosenfeld AL, Mandelaris GA, Tardieu PB. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: rapid-prototype medical modeling. Int J Periodontics Restorative Dent. 2006 26 : 347 353.
    • (2006) Int J Periodontics Restorative Dent. , vol.26 , pp. 347-353
    • Rosenfeld, A.L.1    Mandelaris, G.A.2    Tardieu, P.B.3
  • 67
    • 33745380017 scopus 로고    scopus 로고
    • Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 1: Diagnostics, imaging, and collaborative accountability
    • Rosenfeld AL, Mandelaris GA, Tardieu PB. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 1: diagnostics, imaging, and collaborative accountability. Int J Periodontics Restorative Dent. 2006 26 : 215 221.
    • (2006) Int J Periodontics Restorative Dent. , vol.26 , pp. 215-221
    • Rosenfeld, A.L.1    Mandelaris, G.A.2    Tardieu, P.B.3
  • 68
    • 26944469120 scopus 로고    scopus 로고
    • In vitro accuracy of a novel registration and targeting technique for image-guided template production
    • Widmann G, Widmann R, Widmann E, Jaschke W, Bale RJ. In vitro accuracy of a novel registration and targeting technique for image-guided template production. Clin Oral Implants Res. 2005 16 : 502 508.
    • (2005) Clin Oral Implants Res. , vol.16 , pp. 502-508
    • Widmann, G.1    Widmann, R.2    Widmann, E.3    Jaschke, W.4    Bale, R.J.5
  • 69
    • 0041380912 scopus 로고    scopus 로고
    • Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: Assessment of accuracy
    • Wagner A, Wanschitz F, Birkfellner W, Zauza K, Klug C, Schicho K et al. Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. Clin Oral Impl Res. 2003 14 : 340 348.
    • (2003) Clin Oral Impl Res. , vol.14 , pp. 340-348
    • Wagner, A.1    Wanschitz, F.2    Birkfellner, W.3    Zauza, K.4    Klug, C.5    Schicho, K.6
  • 70
    • 8444252897 scopus 로고    scopus 로고
    • Navigation surgery for dental implants: Assessment of accuracy of the image guided implantology system
    • Casap N, Wexler A, Persky N, Schneider A, Lustmann J. Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system. J Oral Maxillofac Surg. 2004 62 : 116 119.
    • (2004) J Oral Maxillofac Surg. , vol.62 , pp. 116-119
    • Casap, N.1    Wexler, A.2    Persky, N.3    Schneider, A.4    Lustmann, J.5
  • 71
    • 19044395724 scopus 로고    scopus 로고
    • Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible
    • Wanschitz F, Birkfellner W, Watzinger F, Schopper C, Patruta S, Kainberger F et al. Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. Clin Oral Implants Res. 2002 13 : 59 64.
    • (2002) Clin Oral Implants Res. , vol.13 , pp. 59-64
    • Wanschitz, F.1    Birkfellner, W.2    Watzinger, F.3    Schopper, C.4    Patruta, S.5    Kainberger, F.6
  • 72
    • 0035172812 scopus 로고    scopus 로고
    • Navigational precision of drilling tools preventing damage to the mandibular canal
    • Gaggl A, Schultes G, Karcher H. Navigational precision of drilling tools preventing damage to the mandibular canal. J Craniomaxillofac Surg. 2001 29 : 271 275.
    • (2001) J Craniomaxillofac Surg. , vol.29 , pp. 271-275
    • Gaggl, A.1    Schultes, G.2    Karcher, H.3
  • 75
    • 0036977871 scopus 로고    scopus 로고
    • Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine
    • Fortin T, Champleboux G, Bianchi S, Buatois H, Coudert JL. Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. Clin Oral Implants Res. 2002 13 : 651 656.
    • (2002) Clin Oral Implants Res. , vol.13 , pp. 651-656
    • Fortin, T.1    Champleboux, G.2    Bianchi, S.3    Buatois, H.4    Coudert, J.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.