메뉴 건너뛰기




Volumn 7, Issue SUPPL. 1, 2005, Pages

A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study

Author keywords

Br nemark System ; Dental implants; Drilling templates; Guided surgery; Prospective clinical study; TiUnite

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL EXAMINATION; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; EDENTULOUSNESS; EVALUATION; FOLLOW UP; HUMAN; MEDICAL RECORD; SURGICAL TECHNIQUE; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TREATMENT PLANNING;

EID: 20744446711     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (332)

References (22)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark P-I, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977; 16:1-132.
    • (1977) Scand J Plast Reconstr Surg , vol.16 , pp. 1-132
    • Brånemark, P.-I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0348111307 scopus 로고    scopus 로고
    • Implant treatment in the edentulous mandible: A prospective study on Brånemark System implants over more than 20 years
    • Ekelund J-A, Lindquist LW, Carlsson GE, Jemt T. Implant treatment in the edentulous mandible: a prospective study on Brånemark System implants over more than 20 years. Int J Prosthodont 2003; 16:602-608.
    • (2003) Int J Prosthodont , vol.16 , pp. 602-608
    • Ekelund, J.-A.1    Lindquist, L.W.2    Carlsson, G.E.3    Jemt, T.4
  • 4
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomater Mater Res 1998; 43:192-203.
    • (1998) J Biomater Mater Res , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 6
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997; 12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 7
    • 0035350613 scopus 로고    scopus 로고
    • Immediate loading of implants with fixed restorations in the completely edentulous mandible: Report of 27 patients from a private practice
    • Ganeles J, Rosenberg MM, Holt RL, Reichman LH. Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice. Int J Oral Maxillofac Implants 2001; 16:418-426.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 418-426
    • Ganeles, J.1    Rosenberg, M.M.2    Holt, R.L.3    Reichman, L.H.4
  • 8
    • 0038176376 scopus 로고    scopus 로고
    • Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: A prospective, open-ended, longitudinal study
    • Becker W, Backer BE, Huffstetlert S. Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study. J Periodontol 2003; 74:695-702.
    • (2003) J Periodontol , vol.74 , pp. 695-702
    • Becker, W.1    Backer, B.E.2    Huffstetlert, S.3
  • 9
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark TiUnite™ implants placed predominantly in soft bone: 1-Year results of a prospective clinical study
    • Glauser R, Lundgren AK, Gottlow J, et al. Immediate occlusal loading of Brånemark TiUnite™ implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res 2003; 5(Suppl 1):47-56.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.1 SUPPL. , pp. 47-56
    • Glauser, R.1    Lundgren, A.K.2    Gottlow, J.3
  • 12
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Brånemark PI, Zarb GA, Albrektsson T, eds. Chicago: Quintessence Publishing Company;
    • Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark PI, Zarb GA, Albrektsson T, eds. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago: Quintessence Publishing Company; 1985:199-209.
    • (1985) Tissue-integrated Prostheses: Osseointegration in Clinical Dentistry , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 13
    • 0034326765 scopus 로고    scopus 로고
    • Immediate loading of Brånemark System implants following placement on edentulous patients: A clinical report
    • Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Brånemark System implants following placement on edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000; 15:824-830.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 824-830
    • Horiuchi, K.1    Uchida, H.2    Yamamoto, K.3    Sugimura, M.4
  • 14
    • 0041511713 scopus 로고    scopus 로고
    • Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series
    • Olsson M, Urde G, Andersen JB, Sennerby L. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series. Clin Implant Dent Relat Res 2003; 5(Suppl 1):81-87.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.1 SUPPL. , pp. 81-87
    • Olsson, M.1    Urde, G.2    Andersen, J.B.3    Sennerby, L.4
  • 15
    • 0041511733 scopus 로고    scopus 로고
    • Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: A retrospective 3-year clinical study
    • Rocci A, Martignoni M, Gottlow J. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study. Clin Implant Dent Relat Res 2003; 5(Suppl 1):29-36.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.1 SUPPL. , pp. 29-36
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 16
    • 3042613913 scopus 로고    scopus 로고
    • Early loading of ITI implants supporting a maxillary full-arch prosthesis: 1-Year data of a prospective, randomized study
    • Fischer K, Stenberg T. Early loading of ITI implants supporting a maxillary full-arch prosthesis: 1-year data of a prospective, randomized study. Int J Oral Maxillofac Implants 2004; 19:374-381.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 374-381
    • Fischer, K.1    Stenberg, T.2
  • 17
    • 4444316199 scopus 로고    scopus 로고
    • Immediate loading with fixed screw-retained provisional restorations in edentulous jaws: The pickup technique
    • Gallucci G, Bernard JP, Bertosa M, Belser U. Immediate loading with fixed screw-retained provisional restorations in edentulous jaws: the pickup technique. Int J Oral Maxillofac Implants 2004; 19:524-533.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 524-533
    • Gallucci, G.1    Bernard, J.P.2    Bertosa, M.3    Belser, U.4
  • 19
    • 8344263850 scopus 로고    scopus 로고
    • An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: A clinical report on immediate loading
    • Fortin T, Isidori M, Blanchet E, Perriat M, Bouchet H, Coudert JL. An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. Clin Implant Dent Relat Res 2004; 6:111-119.
    • (2004) Clin Implant Dent Relat Res , vol.6 , pp. 111-119
    • Fortin, T.1    Isidori, M.2    Blanchet, E.3    Perriat, M.4    Bouchet, H.5    Coudert, J.L.6
  • 22
    • 0035748966 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark implants applied in various jawbone regions: A prospective, 1-year clinical study
    • Glauser R, Rée A, Lundgren AK, Gottlow J, Hämmerle C, Schärer P. Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res 2001; 3:204-213.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 204-213
    • Glauser, R.1    Rée, A.2    Lundgren, A.K.3    Gottlow, J.4    Hämmerle, C.5    Schärer, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.