메뉴 건너뛰기




Volumn 95, Issue 3, 2008, Pages 374-380

Image guided radiotherapy for prostate cancer

Author keywords

Image guided radiotherapy; Prostate cancer

Indexed keywords

BRACHYTHERAPY; CANCER RADIOTHERAPY; COMPUTER ASSISTED RADIOTHERAPY; DISEASE CONTROL; EXTERNAL BEAM RADIOTHERAPY; HUMAN; PATIENT POSITIONING; PROSTATE CANCER; RADIATION DOSE DISTRIBUTION; RADIATION INJURY; REVIEW; X RAY;

EID: 42149084495     PISSN: 00074551     EISSN: 17696917     Source Type: Journal    
DOI: 10.1684/bdc.2008.0599     Document Type: Review
Times cited : (18)

References (72)
  • 2
    • 0029031844 scopus 로고
    • The treatment of prostate cancer by conventional radiation therapy: An analysis of long-term outcome
    • Zietman AL, Coen JJ, Dallow KC, Shipley WU. The treatment of prostate cancer by conventional radiation therapy: an analysis of long-term outcome. Int J Radiat Oncol Biol Phys 1995; 32: 287-92.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 287-292
    • Zietman, A.L.1    Coen, J.J.2    Dallow, K.C.3    Shipley, W.U.4
  • 3
    • 0029069361 scopus 로고
    • Prostate-specific antigen for pretreatment prediction and posttreatment evaluation of outcome after definitive irradiation for prostate cancer
    • Kuban AD, El-Mahdi AM, Schellhammer PF. Prostate-specific antigen for pretreatment prediction and posttreatment evaluation of outcome after definitive irradiation for prostate cancer. Int J Radiat Oncol Biol Phys 1995; 32: 307-16.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 307-316
    • Kuban, A.D.1    El-Mahdi, A.M.2    Schellhammer, P.F.3
  • 4
    • 0028910506 scopus 로고
    • Advanced prostate cancer: The results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone
    • Shipley WU, Verhey LJ, Munzenrider JE, Suit HD, Urie MM, McManus PL, et al. Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone. Int J Radiat Oncol Biol Phys 1995; 32: 3-12.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 3-12
    • Shipley, W.U.1    Verhey, L.J.2    Munzenrider, J.E.3    Suit, H.D.4    Urie, M.M.5    McManus, P.L.6
  • 5
    • 20144373530 scopus 로고    scopus 로고
    • Phase III pilot study of dose escalation using conformal radiotherapy in prostate cancer: PSA control and side effects
    • Dearnaley DP, Hall E, Lawrence D, Huddart RA, Eeles R, Nutting CM, et al. Phase III pilot study of dose escalation using conformal radiotherapy in prostate cancer: PSA control and side effects. Br J Cancer 2005; 92: 488-98.
    • (2005) Br J Cancer , vol.92 , pp. 488-498
    • Dearnaley, D.P.1    Hall, E.2    Lawrence, D.3    Huddart, R.A.4    Eeles, R.5    Nutting, C.M.6
  • 6
    • 0036680314 scopus 로고    scopus 로고
    • Pollack A, Zagars GK, Starkschall G, Antolak JA, Lee JJ, Huang E, et al. Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys 2002; 53: 1097-105.
    • Pollack A, Zagars GK, Starkschall G, Antolak JA, Lee JJ, Huang E, et al. Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys 2002; 53: 1097-105.
  • 7
    • 24644443217 scopus 로고    scopus 로고
    • Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate. A randomized controlled trial
    • Zietman AL, DeSilvio ML, Slater JD, Rossi CJ, Miller DW, Adams JA, et al. Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate. A randomized controlled trial. JAMA 2005; 294: 1233-9.
    • (2005) JAMA , vol.294 , pp. 1233-1239
    • Zietman, A.L.1    DeSilvio, M.L.2    Slater, J.D.3    Rossi, C.J.4    Miller, D.W.5    Adams, J.A.6
  • 8
    • 33646462895 scopus 로고    scopus 로고
    • Dose-response in radiotherapy for localized prostate cancer: Results of the Dutch multicenter randomized phase III trial comparing 68 Gy of radiotherapy with 78 Gy
    • Peeters ST, Heemsbergen WD, Koper PC, van Putten WL, Slot A, Dielwart MF, et al. Dose-response in radiotherapy for localized prostate cancer: results of the Dutch multicenter randomized phase III trial comparing 68 Gy of radiotherapy with 78 Gy. J Clin Oncol 2006; 24: 1990-6.
    • (2006) J Clin Oncol , vol.24 , pp. 1990-1996
    • Peeters, S.T.1    Heemsbergen, W.D.2    Koper, P.C.3    van Putten, W.L.4    Slot, A.5    Dielwart, M.F.6
  • 9
    • 0003418872 scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • International Commission on Radiation units and Measurements, Bethesda;
    • International Commission on Radiation units and Measurements. Prescribing, recording and reporting photon beam therapy. ICRU Report 50. Bethesda; 1993.
    • (1993) ICRU Report , vol.50
  • 10
    • 0029810297 scopus 로고    scopus 로고
    • Target margins for random geometrical uncertainties in conformal radiotherapy
    • Bel A, van Herk M, Lebesque J. Target margins for random geometrical uncertainties in conformal radiotherapy. Med Phys 1996; 23: 1537-45.
    • (1996) Med Phys , vol.23 , pp. 1537-1545
    • Bel, A.1    van Herk, M.2    Lebesque, J.3
  • 11
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 2000; 47: 1121-35.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 13
    • 0030033457 scopus 로고    scopus 로고
    • A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy
    • Song PY, Washington M, Vaida F, Hamilton R, Spelbring D, Wyman B, et al. A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 1996; 34: 213-9.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , pp. 213-219
    • Song, P.Y.1    Washington, M.2    Vaida, F.3    Hamilton, R.4    Spelbring, D.5    Wyman, B.6
  • 14
  • 15
    • 0032528241 scopus 로고    scopus 로고
    • Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging
    • Greer PB, Mortensen TM, Jose CC. Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging. Int J Radiat Oncol Biol Phys 1998; 41: 1193-9.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 1193-1199
    • Greer, P.B.1    Mortensen, T.M.2    Jose, C.C.3
  • 16
    • 0035160403 scopus 로고    scopus 로고
    • Patient positioning using detailed three-dimensional surface data for patients undergoing conformal radiation therapy for carcinoma of the prostate: A feasibility study
    • MacKay RI, Graham PA, Logue JP, Moore CJ. Patient positioning using detailed three-dimensional surface data for patients undergoing conformal radiation therapy for carcinoma of the prostate: a feasibility study. Int J Radiat Oncol Biol Phys 2001; 49: 225-30.
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 225-230
    • MacKay, R.I.1    Graham, P.A.2    Logue, J.P.3    Moore, C.J.4
  • 17
    • 0036499164 scopus 로고    scopus 로고
    • Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer
    • Soete G, Van de Steene J, Verellen D, Vinh-Hung V, Van den Berge D, Michielsen D, et al. Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2002; 52: 694-8.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 694-698
    • Soete, G.1    Van de Steene, J.2    Verellen, D.3    Vinh-Hung, V.4    Van den Berge, D.5    Michielsen, D.6
  • 19
    • 0036137840 scopus 로고    scopus 로고
    • The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer
    • Wachter S, Gerstner N, Dorner D, Goldner G, Colotto A, Wambersie A, et al. The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2002; 52: 91-100.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 91-100
    • Wachter, S.1    Gerstner, N.2    Dorner, D.3    Goldner, G.4    Colotto, A.5    Wambersie, A.6
  • 20
    • 2442480740 scopus 로고    scopus 로고
    • Target repositioning optimization in prostate cancer: Is intensity-modulated radiotherapy under stereotactic conditions feasible?
    • Miralbell R, Mollà M, Arnalte R, Canales S, Vargas E, Linero D, et al. Target repositioning optimization in prostate cancer: is intensity-modulated radiotherapy under stereotactic conditions feasible? Int J Radiat Oncol Biol Phys 2004; 59: 366-71.
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 366-371
    • Miralbell, R.1    Mollà, M.2    Arnalte, R.3    Canales, S.4    Vargas, E.5    Linero, D.6
  • 21
    • 11144352756 scopus 로고    scopus 로고
    • The effect of an endorectal balloon and off-line correction on the interfraction systematic and random prostate position variations: A comparative study
    • van Lin EN, van der Vight LP, Witjes JA, Huisman HJ, Leer JW, Visser AG. The effect of an endorectal balloon and off-line correction on the interfraction systematic and random prostate position variations: a comparative study. Int J Radiat Oncol Biol Phys 2005; 61: 278-88.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 278-288
    • van Lin, E.N.1    van der Vight, L.P.2    Witjes, J.A.3    Huisman, H.J.4    Leer, J.W.5    Visser, A.G.6
  • 22
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer
    • Willoughby TR, Kupelian PA, Pouliot J, Shinohara K, Aubin M, Roach 3rd M, et al. Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys 2006; 65: 528-34.
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 528-534
    • Willoughby, T.R.1    Kupelian, P.A.2    Pouliot, J.3    Shinohara, K.4    Aubin, M.5    Roach 3rd, M.6
  • 23
  • 25
    • 33846849668 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • Kitamura K, Shirato H, Shimizu S, Shinohara N, Harabayashi T, Shimizu T, et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Int J Radiat Oncol Biol Phys 1999; 43: 719-25.
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 719-725
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3    Shinohara, N.4    Harabayashi, T.5    Shimizu, T.6
  • 26
    • 22144456659 scopus 로고    scopus 로고
    • Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability
    • Kupelian PA, Willoughby TR, Meeks SL, Forbes A, Wagner T, Maach M, et al. Intraprostatic fiducials for localization of the prostate gland: monitoring intermarker distances during radiation therapy to test for marker stability. Int J Radiat Oncol Biol Phys 2005; 62: 1291-6.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1291-1296
    • Kupelian, P.A.1    Willoughby, T.R.2    Meeks, S.L.3    Forbes, A.4    Wagner, T.5    Maach, M.6
  • 27
    • 0032170658 scopus 로고    scopus 로고
    • High-precision conformal radiotherapy (HPCRT) of prostate cancer - A new technique for exact positioning of the prostate at the time of treatment
    • Bergström P, Löfroth P, Widmark A. High-precision conformal radiotherapy (HPCRT) of prostate cancer - A new technique for exact positioning of the prostate at the time of treatment. Int J Radiat Oncol Biol Phys 1998; 42: 305-11.
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 305-311
    • Bergström, P.1    Löfroth, P.2    Widmark, A.3
  • 28
    • 0142248775 scopus 로고    scopus 로고
    • Can digitally reconstructed radiographs (DRRS) replace simulation films in prostate cancer conformal radiotherapy?
    • Bollet MA, McNair HA, Hansen VN, Norman A, O'Doherty U, Taylor H, et al. Can digitally reconstructed radiographs (DRRS) replace simulation films in prostate cancer conformal radiotherapy? Int J Radiat Oncol Biol Phys 2003; 57: 1122-30.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1122-1130
    • Bollet, M.A.1    McNair, H.A.2    Hansen, V.N.3    Norman, A.4    O'Doherty, U.5    Taylor, H.6
  • 29
    • 0035252342 scopus 로고    scopus 로고
    • Set-up verification using portal imaging; review of current clinical practice
    • Hurkmans CW, Remeijer P, Lebesque JV, Mijnheer JB. Set-up verification using portal imaging; review of current clinical practice. Radiother Oncol 2001; 58: 105-20.
    • (2001) Radiother Oncol , vol.58 , pp. 105-120
    • Hurkmans, C.W.1    Remeijer, P.2    Lebesque, J.V.3    Mijnheer, J.B.4
  • 31
    • 0028998318 scopus 로고
    • Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging
    • Van den Heuvel F, De Neve W, Verellen D, Coghe M, Coen V, Storme G. Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging. Radiother Oncol 1995; 35: 232-9.
    • (1995) Radiother Oncol , vol.35 , pp. 232-239
    • Van den Heuvel, F.1    De Neve, W.2    Verellen, D.3    Coghe, M.4    Coen, V.5    Storme, G.6
  • 32
    • 0029996627 scopus 로고    scopus 로고
    • High-pecision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging
    • Bel A, Vos PH, Rodrigus PT, Creutzberg CL, Visser AG, Stroom JC, et al. High-pecision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging. Int J Radiat Oncol Biol Phys 1996; 35: 321-32.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 321-332
    • Bel, A.1    Vos, P.H.2    Rodrigus, P.T.3    Creutzberg, C.L.4    Visser, A.G.5    Stroom, J.C.6
  • 33
    • 0035018405 scopus 로고    scopus 로고
    • Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58
    • Herman MG, Balter JM, Jaffray DA, McGee KP, Munro P, Shalev S, et al. Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58. Med Phys 2001; 28: 712-37.
    • (2001) Med Phys , vol.28 , pp. 712-737
    • Herman, M.G.1    Balter, J.M.2    Jaffray, D.A.3    McGee, K.P.4    Munro, P.5    Shalev, S.6
  • 34
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • Kirby MC, Williams PC. The use of an electronic portal imaging device for exit dosimetry and quality control measurements. Int J Radiat Oncol Biol Phys 1995; 31: 593-603.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 36
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging
    • Verellen D, Soete G, Linthout N, Van Acker S, De Roover P, Vinh-Hung V, et al. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. Radiother Oncol 2003; 67: 129-41.
    • (2003) Radiother Oncol , vol.67 , pp. 129-141
    • Verellen, D.1    Soete, G.2    Linthout, N.3    Van Acker, S.4    De Roover, P.5    Vinh-Hung, V.6
  • 37
    • 33846829586 scopus 로고    scopus 로고
    • X-ray assisted positioning of patients treated by conformal are radiotherapy for prostate cancer: Comparison of setup accuracy using implanted markers versus bony structures
    • Soete G, De Cock M, Verellen D, Michielsen D, Keuppens F, Storme G. X-ray assisted positioning of patients treated by conformal are radiotherapy for prostate cancer: comparison of setup accuracy using implanted markers versus bony structures. Int J Radiat Oncol Biol Phys 2007; 67: 823-7.
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 823-827
    • Soete, G.1    De Cock, M.2    Verellen, D.3    Michielsen, D.4    Keuppens, F.5    Storme, G.6
  • 38
    • 28744456496 scopus 로고    scopus 로고
    • Targeting accuracy of an image guided gating system for stereotactic body radiotherapy
    • Tenn SE, Solberg TD, Medin PM. Targeting accuracy of an image guided gating system for stereotactic body radiotherapy. Phys Med Biol 2005; 50: 5443-62.
    • (2005) Phys Med Biol , vol.50 , pp. 5443-5462
    • Tenn, S.E.1    Solberg, T.D.2    Medin, P.M.3
  • 39
    • 33750294751 scopus 로고    scopus 로고
    • Breathing-synchronized irradiation using stereoscopic kV-imaging to limit influence of interplay between leaf motion and organ motion in 3D-CRT and IMRT: Dosimetric verification and first clinical experience
    • Verellen D, Tournel K, Van de Steene J, Linthout N, Wauters T, Vinh-Hung V, et al. Breathing-synchronized irradiation using stereoscopic kV-imaging to limit influence of interplay between leaf motion and organ motion in 3D-CRT and IMRT: Dosimetric verification and first clinical experience. Int J Radiat Oncol Biol Phys 2006; 66: s108-s119.
    • (2006) Int J Radiat Oncol Biol Phys , vol.66
    • Verellen, D.1    Tournel, K.2    Van de Steene, J.3    Linthout, N.4    Wauters, T.5    Vinh-Hung, V.6
  • 41
    • 33749247062 scopus 로고    scopus 로고
    • Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system
    • Gibbs IC. Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system. Cancer Radiother 2006; 10: 283-7.
    • (2006) Cancer Radiother , vol.10 , pp. 283-287
    • Gibbs, I.C.1
  • 42
    • 0038377171 scopus 로고    scopus 로고
    • Evaluation of mechanical precision and alignment uncertainties for an integrated CT/Linac system
    • Court L, Rosen I, Mohan R, Dong L. Evaluation of mechanical precision and alignment uncertainties for an integrated CT/Linac system. Med Phys 2003; 30: 1198-210.
    • (2003) Med Phys , vol.30 , pp. 1198-1210
    • Court, L.1    Rosen, I.2    Mohan, R.3    Dong, L.4
  • 47
    • 0345256658 scopus 로고    scopus 로고
    • Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers
    • Van den Heuvel F, Powell T. Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers. Med Phys 2003; 30: 2878-87.
    • (2003) Med Phys , vol.30 , pp. 2878-2887
    • Van den Heuvel, F.1    Powell, T.2
  • 48
    • 4544360914 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: Dose deposition in a transverse magnetic field
    • Raaymakers BW, Raaijmakers AJ, Kotte AN, Jette D, Lagendijk JJ. Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field. Phys Med Biol 2004; 49: 4109-18.
    • (2004) Phys Med Biol , vol.49 , pp. 4109-4118
    • Raaymakers, B.W.1    Raaijmakers, A.J.2    Kotte, A.N.3    Jette, D.4    Lagendijk, J.J.5
  • 50
    • 0025255518 scopus 로고
    • Radiobiological and physical basis for radiotherapy with protons and heavier ions
    • Kraft G. Radiobiological and physical basis for radiotherapy with protons and heavier ions. Strahlenther Onkol 1990; 166: 10-3.
    • (1990) Strahlenther Onkol , vol.166 , pp. 10-13
    • Kraft, G.1
  • 52
    • 21844461581 scopus 로고    scopus 로고
    • Interobserver delineation variation using CT versus combined CT + MRI in intensity-modulated radiotherapy for prostate cancer
    • Villeirs GM, Van Vaerenbergh K, Vakaet L, Bral S, Claus F, De Neve WJ, et al. Interobserver delineation variation using CT versus combined CT + MRI in intensity-modulated radiotherapy for prostate cancer. Strahlenther Onkol 2005; 181: 424-30.
    • (2005) Strahlenther Onkol , vol.181 , pp. 424-430
    • Villeirs, G.M.1    Van Vaerenbergh, K.2    Vakaet, L.3    Bral, S.4    Claus, F.5    De Neve, W.J.6
  • 53
    • 31144459510 scopus 로고    scopus 로고
    • Prediction of organ-confined prostate cancer: Incremental value of MR imaging and MR spectroscopic imaging to staging nomograms
    • Wang L, Hricak H, Kattan MW, Chen HN, Scardino PT, Kuroiwa K. Prediction of organ-confined prostate cancer: incremental value of MR imaging and MR spectroscopic imaging to staging nomograms. Radiology 2006; 238: 597-603.
    • (2006) Radiology , vol.238 , pp. 597-603
    • Wang, L.1    Hricak, H.2    Kattan, M.W.3    Chen, H.N.4    Scardino, P.T.5    Kuroiwa, K.6
  • 55
    • 10044234012 scopus 로고    scopus 로고
    • Radiation dose delivered to the proximal penis as a predictor of the risk of erectile dysfunction after three-dimensional conformal radiotherapy for localized prostate cancer
    • Wernicke AG, Valicenti R, Dieva K, Houser C, Pequignot E. Radiation dose delivered to the proximal penis as a predictor of the risk of erectile dysfunction after three-dimensional conformal radiotherapy for localized prostate cancer. Int J Radiat Oncol Biol Phys 2004; 60: 1357-63.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1357-1363
    • Wernicke, A.G.1    Valicenti, R.2    Dieva, K.3    Houser, C.4    Pequignot, E.5
  • 56
    • 33748874677 scopus 로고    scopus 로고
    • Evaluating the relationship between erectile dysfunction and dose received by the penile bulb: Using data from a randomised controlled trial of conformal radiotherapy in prostate cancer (MRC RT01, ISRCTN47772397)
    • Mangar SA, Sydes MR, Tucker HL, Coffey J, Sohaib SA, Gianolini S, et al. Evaluating the relationship between erectile dysfunction and dose received by the penile bulb: using data from a randomised controlled trial of conformal radiotherapy in prostate cancer (MRC RT01, ISRCTN47772397). Radiother Oncol 2006; 80: 355-62.
    • (2006) Radiother Oncol , vol.80 , pp. 355-362
    • Mangar, S.A.1    Sydes, M.R.2    Tucker, H.L.3    Coffey, J.4    Sohaib, S.A.5    Gianolini, S.6
  • 57
    • 33750317870 scopus 로고    scopus 로고
    • Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging
    • Futterer JJ, Heijmink SW, Scheenen TW, Veltman J, Huisman HJ, Vos P, et al. Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 2006; 241: 449-58.
    • (2006) Radiology , vol.241 , pp. 449-458
    • Futterer, J.J.1    Heijmink, S.W.2    Scheenen, T.W.3    Veltman, J.4    Huisman, H.J.5    Vos, P.6
  • 58
    • 0036644081 scopus 로고    scopus 로고
    • Analysis of intraprostatic failures in patients treated with hormonal therapy and radiotherapy: Implications for conformal therapy planning
    • Cellini N, Morganti AG, Mattiucci GC, Valentini V, Leone M, Luzi S, et al. Analysis of intraprostatic failures in patients treated with hormonal therapy and radiotherapy: implications for conformal therapy planning. Int J Radiat Oncol Biol Phys 2002; 53: 595-9.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 595-599
    • Cellini, N.1    Morganti, A.G.2    Mattiucci, G.C.3    Valentini, V.4    Leone, M.5    Luzi, S.6
  • 59
    • 22444444787 scopus 로고    scopus 로고
    • The magnetic resonance detected intraprostatic lesion in prostate cancer: Planning and delivery of intensity-modulated radiotherapy
    • De Meerleer G, Villeirs G, Bral S, Paelinck L, De Gersem W, Dekuyper P, et al. The magnetic resonance detected intraprostatic lesion in prostate cancer: planning and delivery of intensity-modulated radiotherapy. Radiother Oncol 2005; 75: 325-33.
    • (2005) Radiother Oncol , vol.75 , pp. 325-333
    • De Meerleer, G.1    Villeirs, G.2    Bral, S.3    Paelinck, L.4    De Gersem, W.5    Dekuyper, P.6
  • 60
    • 0242692717 scopus 로고    scopus 로고
    • Time trends in clinical risk stratification for prostate cancer: Implications for outcomes (data from Capsure)
    • Cooperberg MR, Lubeck DP, Mehta SS, Carroll PR. Time trends in clinical risk stratification for prostate cancer: implications for outcomes (data from Capsure). J Urol 2003; 170: S21-S25.
    • (2003) J Urol , vol.170
    • Cooperberg, M.R.1    Lubeck, D.P.2    Mehta, S.S.3    Carroll, P.R.4
  • 61
    • 33947397957 scopus 로고    scopus 로고
    • Overdiagnosis and overtreatment of early detected prostate cancer
    • Bangma CH, Roemeling S, Schroder FH. Overdiagnosis and overtreatment of early detected prostate cancer. World J Urol 2007; 25: 3-9.
    • (2007) World J Urol , vol.25 , pp. 3-9
    • Bangma, C.H.1    Roemeling, S.2    Schroder, F.H.3
  • 64
    • 34047105711 scopus 로고    scopus 로고
    • Oncological and functional results of open, robot-assisted and laparoscopic radical prostatectomy: Does surgical approach and surgical experience matter?
    • Herrmann TR, Rabenalt R, Stolzenburg JU, Liatsikos EN, Imkamp F, Tezval H, et al. Oncological and functional results of open, robot-assisted and laparoscopic radical prostatectomy: does surgical approach and surgical experience matter? World J Urol 2007; 25: 149-60.
    • (2007) World J Urol , vol.25 , pp. 149-160
    • Herrmann, T.R.1    Rabenalt, R.2    Stolzenburg, J.U.3    Liatsikos, E.N.4    Imkamp, F.5    Tezval, H.6
  • 65
    • 9444276580 scopus 로고    scopus 로고
    • Outcomes of external-beam radiation therapy for prostate cancer: A study of medicare beneficiaries in three surveillance, epidemiology and end results areas
    • Fowler Jr. FJ, Barry MJ, Lu-Yao G, Wasson JH, Bin L. Outcomes of external-beam radiation therapy for prostate cancer: a study of medicare beneficiaries in three surveillance, epidemiology and end results areas. J Clin Oncol 1996; 14: 2258-65.
    • (1996) J Clin Oncol , vol.14 , pp. 2258-2265
    • Fowler Jr., F.J.1    Barry, M.J.2    Lu-Yao, G.3    Wasson, J.H.4    Bin, L.5
  • 66
    • 0035868771 scopus 로고    scopus 로고
    • Health-related quality-of-life effects of radical prostatectomy and primary radiotherapy for screen-detected or clinically diagnosed localized prostate cancer
    • Madalinska JB, Essink-Bot ML, de Koning HJ, Kirkels WJ, van der Maas PJ, Schroder FH. Health-related quality-of-life effects of radical prostatectomy and primary radiotherapy for screen-detected or clinically diagnosed localized prostate cancer. J Clin Oncol 2001; 19: 1619-28.
    • (2001) J Clin Oncol , vol.19 , pp. 1619-1628
    • Madalinska, J.B.1    Essink-Bot, M.L.2    de Koning, H.J.3    Kirkels, W.J.4    van der Maas, P.J.5    Schroder, F.H.6
  • 67
    • 0031972670 scopus 로고    scopus 로고
    • Patient-reported symptoms after primary therapy for early prostate cancer: Results of a prospective cohort study
    • Talcott JA, Rieker P, Clark JA, Propert KJ, Weeks JC, Beard CJ, et al. Patient-reported symptoms after primary therapy for early prostate cancer: results of a prospective cohort study. J Clin Oncol 1998; 16: 275-83.
    • (1998) J Clin Oncol , vol.16 , pp. 275-283
    • Talcott, J.A.1    Rieker, P.2    Clark, J.A.3    Propert, K.J.4    Weeks, J.C.5    Beard, C.J.6
  • 68
    • 0034605464 scopus 로고    scopus 로고
    • Health outcomes after prostatectomy or radiotherapy for prostate cancer: Results from the prostate cancer outcomes study
    • Potosky AL, Legler J, Albertsen PC, Stanford JL, Gilliland FD, Hamilton AS, et al. Health outcomes after prostatectomy or radiotherapy for prostate cancer: results from the prostate cancer outcomes study. J Natl Cancer Inst 2000; 92: 1582-92.
    • (2000) J Natl Cancer Inst , vol.92 , pp. 1582-1592
    • Potosky, A.L.1    Legler, J.2    Albertsen, P.C.3    Stanford, J.L.4    Gilliland, F.D.5    Hamilton, A.S.6
  • 70
    • 0346363495 scopus 로고    scopus 로고
    • Radical prostatectomy, external beam radiotherapy < 72 Gy, external beam radiotherapy ≥ 72 Gy, permanent seed implantation or combined seeds/external beam radiotherapy for stage T1-T2 prostate cancer
    • Kupelian PA, Potters L, Khuntia D, Ciezki JP, Reddy CA, Reuther AM, et al. Radical prostatectomy, external beam radiotherapy < 72 Gy, external beam radiotherapy ≥ 72 Gy, permanent seed implantation or combined seeds/external beam radiotherapy for stage T1-T2 prostate cancer. Int J Radiat Oncol Biol Phys 2004; 58: 25-33.
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 25-33
    • Kupelian, P.A.1    Potters, L.2    Khuntia, D.3    Ciezki, J.P.4    Reddy, C.A.5    Reuther, A.M.6
  • 71
    • 21244444149 scopus 로고    scopus 로고
    • Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy
    • de Crevoisier R, Tucker SL, Dong L, Mohan R, Cheung R, Cox JD, et al. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys 2005; 62: 965-73.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 965-973
    • de Crevoisier, R.1    Tucker, S.L.2    Dong, L.3    Mohan, R.4    Cheung, R.5    Cox, J.D.6
  • 72
    • 29244431948 scopus 로고    scopus 로고
    • Evaluation of image-guided radiation therapy (IGRT) technologies and their impact on the outcomes of hypofractionated prostate cancer treatments: A radiobiologic analysis
    • Song WY, Schaly B, Bauman G, Battista JJ, Van Dyk J. Evaluation of image-guided radiation therapy (IGRT) technologies and their impact on the outcomes of hypofractionated prostate cancer treatments: a radiobiologic analysis. Int J Radiat Oncol Biol Phys 2006; 64: 289-300.
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 289-300
    • Song, W.Y.1    Schaly, B.2    Bauman, G.3    Battista, J.J.4    Van Dyk, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.