메뉴 건너뛰기




Volumn 62, Issue 5, 2005, Pages 1291-1296

Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability

Author keywords

Daily localization; External radiation; Intraprostatic markers; Prostate localization; Stability of markers

Indexed keywords

BIOLOGICAL ORGANS; DEFORMATION; IMPLANTS (SURGICAL); PATIENT TREATMENT; STATISTICAL METHODS; X RAY ANALYSIS;

EID: 22144456659     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2005.01.005     Document Type: Article
Times cited : (142)

References (27)
  • 2
    • 0035283698 scopus 로고    scopus 로고
    • Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate
    • H. Alasti, M.P. Petric, C.N. Catton Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate Int J Radiat Oncol Biol Phys 49 2001 869 884
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 869-884
    • Alasti, H.1    Petric, M.P.2    Catton, C.N.3
  • 3
    • 4444285372 scopus 로고    scopus 로고
    • On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma
    • P.W. Chung, T. Haycocks, T. Brown On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma Int J Radiat Oncol Biol Phys 60 2004 329 334
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 329-334
    • Chung, P.W.1    Haycocks, T.2    Brown, T.3
  • 4
    • 0034826907 scopus 로고    scopus 로고
    • Numerical analysis of a model of organ motion using serial imaging measurements from prostate radiotherapy
    • E. Fontenla, C.A. Pelizzari, J.C. Roeske Numerical analysis of a model of organ motion using serial imaging measurements from prostate radiotherapy Phys Med Biol 46 2001 2337 2358
    • (2001) Phys Med Biol , vol.46 , pp. 2337-2358
    • Fontenla, E.1    Pelizzari, C.A.2    Roeske, J.C.3
  • 5
    • 0033237777 scopus 로고    scopus 로고
    • A method to predict the effect of organ motion and set-up variations on treatment plans
    • P.J. Keall, W.A. Beckham, J.T. Booth A method to predict the effect of organ motion and set-up variations on treatment plans Australas Phys Eng Sci Med 22 1999 48 52
    • (1999) Australas Phys Eng Sci Med , vol.22 , pp. 48-52
    • Keall, P.J.1    Beckham, W.A.2    Booth, J.T.3
  • 6
    • 0031058446 scopus 로고    scopus 로고
    • A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy
    • J.H. Killoran, H.M. Kooy, D.J. Gladstone A numerical simulation of organ motion and daily setup uncertainties Implications for radiation therapy Int J Radiat Oncol Biol Phys 37 1997 213 221
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , pp. 213-221
    • Killoran, J.H.1    Kooy, H.M.2    Gladstone, D.J.3
  • 7
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • K. Kitamura, H. Shirato, S. Shimizu Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT) Radiother Oncol 62 2002 275 281
    • (2002) Radiother Oncol , vol.62 , pp. 275-281
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3
  • 8
    • 0033753216 scopus 로고    scopus 로고
    • Ultrasound-based stereotactic guidance in prostate cancer - Quantification of organ motion and set-up errors in external beam radiation therapy
    • J. Lattanzi, S. McNeeley, S. Donnelly Ultrasound-based stereotactic guidance in prostate cancer - quantification of organ motion and set-up errors in external beam radiation therapy Comput Aided Surg 5 2000 289 295
    • (2000) Comput Aided Surg , vol.5 , pp. 289-295
    • Lattanzi, J.1    McNeeley, S.2    Donnelly, S.3
  • 9
    • 0032527644 scopus 로고    scopus 로고
    • Daily CT localization for correcting portal errors in the treatment of prostate cancer
    • J. Lattanzi, S. McNeely, A. Hanlon Daily CT localization for correcting portal errors in the treatment of prostate cancer Int J Radiat Oncol Biol Phys 41 1998 1079 1086
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 1079-1086
    • Lattanzi, J.1    McNeely, S.2    Hanlon, A.3
  • 11
    • 0034566036 scopus 로고    scopus 로고
    • Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers
    • S. Shimizu, H. Shirato, K. Kitamura Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers Int J Radiat Oncol Biol Phys 48 2000 1591 1597
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1591-1597
    • Shimizu, S.1    Shirato, H.2    Kitamura, K.3
  • 12
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • M. van Herk, A. Bruce, A.P. Kroes Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration Int J Radiat Oncol Biol Phys 33 1995 1311 1320
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, A.P.3
  • 13
    • 0033971984 scopus 로고    scopus 로고
    • Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer
    • J. Lattanzi, S. McNeeley, A. Hanlon Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer Urology 55 2000 73 78
    • (2000) Urology , vol.55 , pp. 73-78
    • Lattanzi, J.1    McNeeley, S.2    Hanlon, A.3
  • 14
    • 0028811317 scopus 로고
    • Prostate motion during standard radiotherapy as assessed by fiducial markers
    • J.M. Crook, Y. Raymond, D. Salhani Prostate motion during standard radiotherapy as assessed by fiducial markers Radiother Oncol 37 1995 35 42
    • (1995) Radiother Oncol , vol.37 , pp. 35-42
    • Crook, J.M.1    Raymond, Y.2    Salhani, D.3
  • 15
    • 0037966410 scopus 로고    scopus 로고
    • Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    • H. Dehnad, A.J. Nederveen, U.A. van der Heide Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation Radiother Oncol 67 2003 295 302
    • (2003) Radiother Oncol , vol.67 , pp. 295-302
    • Dehnad, H.1    Nederveen, A.J.2    Van Der Heide, U.A.3
  • 16
    • 0142186646 scopus 로고    scopus 로고
    • Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
    • M.G. Herman, T.M. Pisansky, J.J. Kruse Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device Int J Radiat Oncol Biol Phys 57 2003 1131 1140
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1131-1140
    • Herman, M.G.1    Pisansky, T.M.2    Kruse, J.J.3
  • 17
    • 0034661767 scopus 로고    scopus 로고
    • Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)
    • A. Nederveen, J. Lagendijk, P. Hofman Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK) Int J Radiat Oncol Biol Phys 47 2000 1435 1442
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1435-1442
    • Nederveen, A.1    Lagendijk, J.2    Hofman, P.3
  • 18
    • 0345269966 scopus 로고    scopus 로고
    • Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy
    • H. Shirato, T. Harada, T. Harabayashi Feasibility of insertion/ implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy Int J Radiat Oncol Biol Phys 56 2003 240 247
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 240-247
    • Shirato, H.1    Harada, T.2    Harabayashi, T.3
  • 19
    • 0038372040 scopus 로고    scopus 로고
    • Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID
    • S. Aubin, L. Beaulieu, S. Pouliot Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID Med Phys 30 2003 1825 1832
    • (2003) Med Phys , vol.30 , pp. 1825-1832
    • Aubin, S.1    Beaulieu, L.2    Pouliot, S.3
  • 20
    • 4444270625 scopus 로고    scopus 로고
    • Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
    • J.F. Aubry, L. Beaulieu, L.M. Girouard Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers Int J Radiat Oncol Biol Phys 60 2004 30 39
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 30-39
    • Aubry, J.F.1    Beaulieu, L.2    Girouard, L.M.3
  • 21
    • 0038210245 scopus 로고    scopus 로고
    • (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device
    • J. Pouliot, M. Aubin, K.M. Langen (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device Int J Radiat Oncol Biol Phys 56 2003 862 866
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 862-866
    • Pouliot, J.1    Aubin, M.2    Langen, K.M.3
  • 24
    • 0036680531 scopus 로고    scopus 로고
    • Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions
    • K. Kitamura, H. Shirato, Y. Seppenwoolde Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions Int J Radiat Oncol Biol Phys 53 2002 1117 1123
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1117-1123
    • Kitamura, K.1    Shirato, H.2    Seppenwoolde, Y.3
  • 25
    • 0141504143 scopus 로고    scopus 로고
    • Evaluation of ultrasound-based prostate localization for image-guided radiotherapy
    • K.M. Langen, J. Pouliot, C. Anezinos Evaluation of ultrasound-based prostate localization for image-guided radiotherapy Int J Radiat Oncol Biol Phys 57 2003 635 644
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 635-644
    • Langen, K.M.1    Pouliot, J.2    Anezinos, C.3
  • 26
    • 32744459742 scopus 로고    scopus 로고
    • Using daily MVCT images to calculate daily rectal dose volume histograms in prostate cancer patients treated with a helical tomotherapy unit
    • K. Langen, D. Poole, Y. Zhang Using daily MVCT images to calculate daily rectal dose volume histograms in prostate cancer patients treated with a helical tomotherapy unit Int J Radiat Oncol Biol Phys 60 2004 S613
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 613
    • Langen, K.1    Poole, D.2    Zhang, Y.3
  • 27
    • 32744467625 scopus 로고    scopus 로고
    • Daily megavoltage CT image guidance in the treatment of localized prostate cancer
    • Y. Zhang, K. Langen, D. Poole Daily megavoltage CT image guidance in the treatment of localized prostate cancer Int J Radiat Oncol Biol Phys 60 2004 S616
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 616
    • Zhang, Y.1    Langen, K.2    Poole, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.