메뉴 건너뛰기




Volumn 61, Issue 1, 2005, Pages 278-288

The effect of an endorectal balloon and off-line correction on the interfraction systematic and random prostate position variations: A comparative study

Author keywords

Endorectal balloon; Markers; Portal imaging; Prostate; Prostate motion; Radiotherapy

Indexed keywords

ENDORECTAL BALLOON (ERB); PROSTATE CANCER; PROSTATE GLAND MOTION; PROSTATE POSITION;

EID: 11144352756     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2004.09.042     Document Type: Article
Times cited : (86)

References (30)
  • 2
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • M. Van Herk, A. Bruce, A.P. Kroes, T. Shouman, A. Touw, J.V. Lebesque Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration Int J Radiat Oncol Biol Phys 33 1995 1311 1320
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, A.P.3    Shouman, T.4    Touw, A.5    Lebesque, J.V.6
  • 3
    • 0034307033 scopus 로고    scopus 로고
    • Complications from radiotherapy dose escalation in prostate cancer: Preliminary results of a randomized trial
    • M.R. Storey, A. Pollack, G. Zagars, L. Smith, J. Antolak, I. Rosen Complications from radiotherapy dose escalation in prostate cancer: Preliminary results of a randomized trial Int J Radiat Oncol Biol Phys 48 2000 635 642
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 635-642
    • Storey, M.R.1    Pollack, A.2    Zagars, G.3    Smith, L.4    Antolak, J.5    Rosen, I.6
  • 5
    • 0037966410 scopus 로고    scopus 로고
    • Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    • H. Dehnad, A.J. Nederveen, U.A. van der Heide, R.J. van Moorselaar, P. Hofman, J.J. Lagendijk Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation Radiother Oncol 67 2003 295 302
    • (2003) Radiother Oncol , vol.67 , pp. 295-302
    • Dehnad, H.1    Nederveen, A.J.2    Van Der Heide, U.A.3    Van Moorselaar, R.J.4    Hofman, P.5    Lagendijk, J.J.6
  • 6
    • 0142186646 scopus 로고    scopus 로고
    • Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
    • M.G. Herman, T.M. Pisansky, J.J. Kruse, J.I. Prisciandaro, B.J. Davis, B.F. King Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device Int J Radiat Oncol Biol Phys 57 2003 1131 1140
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1131-1140
    • Herman, M.G.1    Pisansky, T.M.2    Kruse, J.J.3    Prisciandaro, J.I.4    Davis, B.J.5    King, B.F.6
  • 9
    • 0031051526 scopus 로고    scopus 로고
    • Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study
    • E. Vigneault, J. Pouliot, J. Laverdiere, J. Roy, M. Dorion Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study Int J Radiat Oncol Biol Phys 37 1997 205 212
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , pp. 205-212
    • Vigneault, E.1    Pouliot, J.2    Laverdiere, J.3    Roy, J.4    Dorion, M.5
  • 10
    • 0035283698 scopus 로고    scopus 로고
    • Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate
    • H. Alasti, M.P. Petric, C.N. Catton, P.R. Warde Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate Int J Radiat Oncol Biol Phys 49 2001 869 884
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 869-884
    • Alasti, H.1    Petric, M.P.2    Catton, C.N.3    Warde, P.R.4
  • 11
    • 0038415720 scopus 로고    scopus 로고
    • Experience of ultrasound-based daily prostate localization
    • A. Chandra, L. Dong, E. Huang Experience of ultrasound-based daily prostate localization Int J Radiat Oncol Biol Phys 56 2003 436 447
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 436-447
    • Chandra, A.1    Dong, L.2    Huang, E.3
  • 12
    • 85024971634 scopus 로고    scopus 로고
    • Grant W3 prostate immobilization using a rectal balloon
    • J.E. McGary, B.S. Teh, E.B. Butler, Grant W3 Prostate immobilization using a rectal balloon J Appl Clin Med Phys 3 2002 6 11
    • (2002) J Appl Clin Med Phys , vol.3 , pp. 6-11
    • McGary, J.E.1    Teh, B.S.2    Butler, E.B.3
  • 13
    • 0035576802 scopus 로고    scopus 로고
    • A practical method to achieve prostate gland immobilization and target verification for daily treatment
    • A.V. D'Amico, J. Manola, M. Loffredo A practical method to achieve prostate gland immobilization and target verification for daily treatment Int J Radiat Oncol Biol Phys 51 2001 1431 1436
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1431-1436
    • D'Amico, A.V.1    Manola, J.2    Loffredo, M.3
  • 14
    • 0035284066 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy (IMRT) for prostate cancer with the use of a rectal balloon for prostate immobilization: Acute toxicity and dose-volume analysis
    • B.S. Teh, W.Y. Mai, B.M. Uhl Intensity-modulated radiation therapy (IMRT) for prostate cancer with the use of a rectal balloon for prostate immobilization: Acute toxicity and dose-volume analysis Int J Radiat Oncol Biol Phys 49 2001 705 712
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 705-712
    • Teh, B.S.1    Mai, W.Y.2    Uhl, B.M.3
  • 15
    • 0036835238 scopus 로고    scopus 로고
    • The use of rectal balloon during the delivery of intensity modulated radiotherapy (IMRT) for prostate cancer: More than just a prostate gland immobilization device?
    • B.S. Teh, J.E. McGary, L. Dong The use of rectal balloon during the delivery of intensity modulated radiotherapy (IMRT) for prostate cancer: More than just a prostate gland immobilization device? Cancer J 8 2002 476 483
    • (2002) Cancer J , vol.8 , pp. 476-483
    • Teh, B.S.1    McGary, J.E.2    Dong, L.3
  • 16
    • 0036137840 scopus 로고    scopus 로고
    • The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer
    • S. Wachter, N. Gerstner, D. Dorner The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer Int J Radiat Oncol Biol Phys 52 2002 91 100
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 91-100
    • Wachter, S.1    Gerstner, N.2    Dorner, D.3
  • 17
    • 0038303679 scopus 로고    scopus 로고
    • Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer
    • R.R. Patel, N. Orton, W.A. Tome, R. Chappell, M.A. Ritter Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer Radiother Oncol 67 2003 285 294
    • (2003) Radiother Oncol , vol.67 , pp. 285-294
    • Patel, R.R.1    Orton, N.2    Tome, W.A.3    Chappell, R.4    Ritter, M.A.5
  • 18
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
    • J.C. Stroom, H.C. de Boer, H. Huizenga, A.G. Visser Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability Int J Radiat Oncol Biol Phys 43 1999 905 919
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 905-919
    • Stroom, J.C.1    De Boer, H.C.2    Huizenga, H.3    Visser, A.G.4
  • 19
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • M. Van Herk, P. Remeijer, C. Rasch, J.V. Lebesque The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy Int J Radiat Oncol Biol Phys 47 2000 1121 1135
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 20
    • 0035370877 scopus 로고    scopus 로고
    • Effectiveness of couch height-based patient setup and an off-line correction protocol in prostate cancer radiotherapy
    • E.N. van Lin, E. Nijenhuis, H. Huizenga, L. van der Vight, A. Visser Effectiveness of couch height-based patient setup and an off-line correction protocol in prostate cancer radiotherapy Int J Radiat Oncol Biol Phys 50 2001 569 577
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 569-577
    • Van Lin, E.N.1    Nijenhuis, E.2    Huizenga, H.3    Van Der Vight, L.4    Visser, A.5
  • 21
    • 0026745010 scopus 로고
    • Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer
    • J. Bijhold, J.V. Lebesque, A.A. Hart, R.E. Vijlbrief Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer Radiother Oncol 24 1992 261 271
    • (1992) Radiother Oncol , vol.24 , pp. 261-271
    • Bijhold, J.1    Lebesque, J.V.2    Hart, A.A.3    Vijlbrief, R.E.4
  • 22
    • 0035425538 scopus 로고    scopus 로고
    • A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload
    • H.C. de Boer, B.J. Heijmen A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload Int J Radiat Oncol Biol Phys 50 2001 1350 1365
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1350-1365
    • De Boer, H.C.1    Heijmen, B.J.2
  • 24
    • 0038210245 scopus 로고    scopus 로고
    • (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device
    • J. Pouliot, M. Aubin, K.M. Langen (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device Int J Radiat Oncol Biol Phys 56 2003 862 866
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 862-866
    • Pouliot, J.1    Aubin, M.2    Langen, K.M.3
  • 25
    • 0036804489 scopus 로고    scopus 로고
    • On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device
    • I.F. Ciernik, B.G. Baumert, P. Egli, C. Glanzmann, U.M. Lutolf On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device Radiother Oncol 65 2002 39 45
    • (2002) Radiother Oncol , vol.65 , pp. 39-45
    • Ciernik, I.F.1    Baumert, B.G.2    Egli, P.3    Glanzmann, C.4    Lutolf, U.M.5
  • 26
    • 0031693144 scopus 로고    scopus 로고
    • Magnetic resonance imaging of prostate cancer: Comparison of image quality using endorectal and pelvic phased array coils
    • J.E. Husband, A.R. Padhani, A.D. MacVicar, P. Revell Magnetic resonance imaging of prostate cancer: Comparison of image quality using endorectal and pelvic phased array coils Clin Radiol 53 1998 673 681
    • (1998) Clin Radiol , vol.53 , pp. 673-681
    • Husband, J.E.1    Padhani, A.R.2    MacVicar, A.D.3    Revell, P.4
  • 27
    • 12444264448 scopus 로고    scopus 로고
    • A study of the effects of internal organ motion on dose escalation in conformal prostate treatments
    • L. Happersett, G.S. Mageras, M.J. Zelefsky A study of the effects of internal organ motion on dose escalation in conformal prostate treatments Radiother Oncol 66 2003 263 270
    • (2003) Radiother Oncol , vol.66 , pp. 263-270
    • Happersett, L.1    Mageras, G.S.2    Zelefsky, M.J.3
  • 28
    • 0345256658 scopus 로고    scopus 로고
    • Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers
    • H.F. Van den, T. Powell, E. Seppi Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers Med Phys 30 2003 2878 2887
    • (2003) Med Phys , vol.30 , pp. 2878-2887
    • Van Den, H.F.1    Powell, T.2    Seppi, E.3
  • 29
    • 0038372040 scopus 로고    scopus 로고
    • Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID
    • S. Aubin, L. Beaulieu, S. Pouliot Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID Med Phys 30 2003 1825 1832
    • (2003) Med Phys , vol.30 , pp. 1825-1832
    • Aubin, S.1    Beaulieu, L.2    Pouliot, S.3
  • 30
    • 0036204888 scopus 로고    scopus 로고
    • Potential improvements in the therapeutic ratio of prostate cancer irradiation: Dose escalation of pathologically identified tumour nodules using intensity modulated radiotherapy
    • C.M. Nutting, C.M. Corbishley, B. Sanchez-Nieto, V.P. Cosgrove, S. Webb, D.P. Dearnaley Potential improvements in the therapeutic ratio of prostate cancer irradiation: Dose escalation of pathologically identified tumour nodules using intensity modulated radiotherapy Br J Radiol 75 2002 151 161
    • (2002) Br J Radiol , vol.75 , pp. 151-161
    • Nutting, C.M.1    Corbishley, C.M.2    Sanchez-Nieto, B.3    Cosgrove, V.P.4    Webb, S.5    Dearnaley, D.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.