메뉴 건너뛰기




Volumn 23, Issue 9, 1996, Pages 1537-1545

Target margins for random geometrical treatment uncertainties in conformal radiotherapy

Author keywords

3 D treatment planning; geometrical treatment uncertainties; morphological image processing; target margins

Indexed keywords

CONVOLUTION; EROSION; GEOMETRY; IMAGE PROCESSING; RADIOTHERAPY; UROLOGY;

EID: 0029810297     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597745     Document Type: Article
Times cited : (114)

References (23)
  • 1
    • 0003651542 scopus 로고
    • International Commission on Radiation Units and Measurements, Bethesda, MD
    • ICRU, "Prescribing, recording, and reporting photon beam therapy," International Commission on Radiation Units and Measurements, Bethesda, MD, 1993.
    • (1993) Prescribing, Recording, and Reporting Photon Beam Therapy
  • 2
    • 0029996627 scopus 로고    scopus 로고
    • High-precision prostate cancer irradiation by clinical application of an off-line patient setup verification procedure, using portal imaging
    • A. Bel, P. H. Vos, P. T. R. Rodrigus, C. L. Creutzberg, A. G. Visser, J. C. Stroom, and J. V. Lebesque, "High-precision prostate cancer irradiation by clinical application of an off-line patient setup verification procedure, using portal imaging," Int. J. Radiat. Oncol. Biol. Phys. 35, 321-332 (1996).
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 321-332
    • Bel, A.1    Vos, P.H.2    Rodrigus, P.T.R.3    Creutzberg, C.L.4    Visser, A.G.5    Stroom, J.C.6    Lebesque, J.V.7
  • 3
    • 0026745010 scopus 로고
    • Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer
    • J. Bijhold, J. V. Lebesque, A. A. M. Hart, and R. E. Vijlbrief, "Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer," Radiother. Oncol 24, 261-271 (1992).
    • (1992) Radiother. Oncol , vol.24 , pp. 261-271
    • Bijhold, J.1    Lebesque, J.V.2    Hart, A.A.M.3    Vijlbrief, R.E.4
  • 5
    • 0026724204 scopus 로고
    • Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements
    • S. A. Rosenthal, J. M. Calvin, J. W. Goldwein, A. R. Smith, and P. H. Blitzer, "Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements," Int. J. Radiat. Oncol. Biol. Phys. 23, 621-625 (1992).
    • (1992) Int. J. Radiat. Oncol. Biol. Phys. , vol.23 , pp. 621-625
    • Rosenthal, S.A.1    Calvin, J.M.2    Goldwein, J.W.3    Smith, A.R.4    Blitzer, P.H.5
  • 6
    • 0028998318 scopus 로고
    • Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging
    • F. Van den Heuvel, W. De Neve, D. Verellen, M. Coghe, V. Coen, and G. Storme, "Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging," Radiother. Oncol. 35, 232-239 (1995).
    • (1995) Radiother. Oncol. , vol.35 , pp. 232-239
    • Van Den Heuvel, F.1    De Neve, W.2    Verellen, D.3    Coghe, M.4    Coen, V.5    Storme, G.6
  • 9
    • 0028363588 scopus 로고
    • A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system
    • J. Gildersleve, D. P. Dearnaley, P. M. Evans, M. Law, C. Rawlings, and W. Swindell, "A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system," Radiother. Oncol. 31, 161-168 (1994).
    • (1994) Radiother. Oncol. , vol.31 , pp. 161-168
    • Gildersleve, J.1    Dearnaley, D.P.2    Evans, P.M.3    Law, M.4    Rawlings, C.5    Swindell, W.6
  • 10
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three-dimensional image-registration
    • M. van Herk, A. Bruce, G. Kroes, T. Shouman, A. Touw, and J. V. Lebesque, "Quantification of organ motion during conformal radiotherapy of the prostate by three-dimensional image-registration," Int. J. Radiat. Oncol. Biol. Phys. 33, 1311-1320 (1995).
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, G.3    Shouman, T.4    Touw, A.5    Lebesque, J.V.6
  • 15
    • 4244178965 scopus 로고
    • Are set-up variations in bony structures equivalent with positional changes of the prostate in external radiotherapy?
    • C. J. M Hoekstra, V. G. M. Althof, H. J. Te Loo, A. van't Riet, and A. C. A. Mak, "Are set-up variations in bony structures equivalent with positional changes of the prostate in external radiotherapy?." (abstract), Radiother. Oncol. 24, 45 (1992).
    • (1992) Radiother. Oncol. , vol.24 , pp. 45
    • Hoekstra, C.J.M.1    Althof, V.G.M.2    Te Loo, H.J.3    Van't Riet, A.4    Mak, A.C.A.5
  • 16
    • 0028960870 scopus 로고
    • Control, correction and modeling of setup errors and organ motion
    • G. J. Kutcher, G. S. Mageras, and S. A. Leibel, "Control, correction and modeling of setup errors and organ motion," Semn. Radiat. Oncol. 5, 134-145 (1995).
    • (1995) Semn. Radiat. Oncol. , vol.5 , pp. 134-145
    • Kutcher, G.J.1    Mageras, G.S.2    Leibel, S.A.3
  • 17
    • 0023132335 scopus 로고
    • Implementation of random positioning error in computerized radiation treatment planning as a result of fractionation
    • J. Leong, "Implementation of random positioning error in computerized radiation treatment planning as a result of fractionation," Phys. Med. Biol. 32, 237-334 (1987).
    • (1987) Phys. Med. Biol. , vol.32 , pp. 237-334
    • Leong, J.1
  • 18
    • 0028027605 scopus 로고
    • Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy
    • V. Rudat, M. Flentje, D. Oetzel, M. Menke, W Schlegel, and M. Wannenmacher, "Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy," Radiother. Oncol. 33, 56-63 (1994).
    • (1994) Radiother. Oncol. , vol.33 , pp. 56-63
    • Rudat, V.1    Flentje, M.2    Oetzel, D.3    Menke, M.4    Schlegel, W.5    Wannenmacher, M.6
  • 20
    • 0027241780 scopus 로고
    • Optimal radiation beam profiles considering uncertainties in beam patient alignment
    • B. K Lind, P. Källman, B. Sundelin, and A. Brahme, "Optimal radiation beam profiles considering uncertainties in beam patient alignment," Acta Oncol. 32, 331-342 (1993).
    • (1993) Acta Oncol. , vol.32 , pp. 331-342
    • Lind, B.K.1    Källman, P.2    Sundelin, B.3    Brahme, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.