Set-up verification using portal imaging; review of current clinical practice

Author keywords

Immobilization; Patient positioning; Portal imaging; Quality control; Set up error

Indexed keywords

ACCURACY; BREAST CANCER; CANCER; CANCER RADIOTHERAPY; CLINICAL PRACTICE; ERROR; GOOD CLINICAL PRACTICE; HEAD AND NECK CANCER; HUMAN; IMAGING; IMMOBILIZATION; LUNG CANCER; MANTLE FIELD RADIOTHERAPY; NOMENCLATURE; PATIENT POSITIONING; PELVIS CANCER; PRIORITY JOURNAL; PROSTATE CANCER; QUALITY CONTROL; REVIEW; SYSTEM ANALYSIS; WHOLE BODY RADIATION;

EID: 0035252342     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(00)00260-7     Document Type: Article
Times cited : (328)

References (105)
  • 36
    • 0031817858 scopus 로고    scopus 로고
    • The magnitude of treatment field set-up parameter correction in radiation therapy
    • (1998) Radiother Oncol , vol.48 , pp. 79-82
    • Gluhchev, G.1
  • 48
    • 0003438221 scopus 로고
    • Use of computers in external beam radiotherapy procedures with high-energy photons and electrons
    • Bethesda, MD: ICRU Publications
    • (1987) ICRU Report, 42
  • 49
    • 0003418877 scopus 로고    scopus 로고
    • Prescribing, recording, and reporting photon beam therapy
    • Bethesda, MD: ICRU Publications
    • (1994) ICRU Report, 50
  • 50
    • 0003418877 scopus 로고    scopus 로고
    • Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50)
    • Bethesda, MD: ICRU Publications
    • (2000) ICRU Report, 62
  • 57
    • 0029829734 scopus 로고    scopus 로고
    • Pelvic irradiation of the obese patient: A treatment strategy involving megavoltage simulation and intratreatment setup corrections
    • (1996) Med Phys , vol.23 , pp. 1897-1902
    • Luchka, K.1    Shalev, S.2
  • 69
    • 0029811663 scopus 로고    scopus 로고
    • Verification and correction of setup deviations in tangential breast irradiation using EPID: Gain versus workload
    • (1996) Med Phys , vol.23 , pp. 1393-1398
    • Pouliot, J.1    Lirette, A.2
  • 75
    • 0002283081 scopus 로고
    • Treatment verification using digital imaging
    • Smith A, editor. Radiation therapy physics
    • (1995) , pp. 155-173
    • Shalev, S.1
  • 98
    • 0003040445 scopus 로고    scopus 로고
    • 3D measurements and correction of systematic patient setup errors in external irradiation of patients with a brain tumor, using digital portal imaging
    • Leavitt DD, Starkschall G, editors. Proceedings of the XIIth international congress of computers in radiotherapy, Madison, WI: Medical Physics Publishing
    • (1997) , pp. 223-226
    • Vos, P.1    Van Riel, V.2    De Winter, K.3
  • 100
    • 4243999430 scopus 로고    scopus 로고
    • Decision criteria and correction strategies in the clinical use of electronic digital portal imagers
    • Leavitt DD, Starkschall G, editors. Proceedings of the XIIth international congress of computers in radiotherapy, Madison: Medical Physics Publishing
    • (1997) , pp. 33-36
    • Vos, P.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.