메뉴 건너뛰기




Volumn 129, Issue 1, 2008, Pages 372-379

An electrochemical impedance biosensor with aptamer-modified pyrolyzed carbon electrode for label-free protein detection

Author keywords

Aptamer; Biosensor; Electrochemical impedance spectroscopy; MEMS; Pyrolyzed carbon; Thrombin

Indexed keywords

CARBON; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; PHOTORESISTS; PROTEINS; PYROLYSIS;

EID: 38149067498     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.08.034     Document Type: Article
Times cited : (132)

References (26)
  • 1
    • 0034603154 scopus 로고    scopus 로고
    • Adaptive recognition by nucleic acid aptamers
    • Hermann T., and Patel D.J. Adaptive recognition by nucleic acid aptamers. Science 287 (2000) 820-825
    • (2000) Science , vol.287 , pp. 820-825
    • Hermann, T.1    Patel, D.J.2
  • 3
    • 0036712790 scopus 로고    scopus 로고
    • An aptamer-based quartz crystal protein biosensor
    • Liss M., Petersen B., Wolf H., and Prohaska E. An aptamer-based quartz crystal protein biosensor. Anal. Chem. 74 (2002) 4488-4495
    • (2002) Anal. Chem. , vol.74 , pp. 4488-4495
    • Liss, M.1    Petersen, B.2    Wolf, H.3    Prohaska, E.4
  • 4
    • 2642579896 scopus 로고    scopus 로고
    • Micromechanical detection of proteins using aptamer-based receptor molecules
    • Savran C.A., Knudsen S.M., Ellington A.D., and Manalis S.R. Micromechanical detection of proteins using aptamer-based receptor molecules. Anal. Chem. 76 (2004) 3194-3198
    • (2004) Anal. Chem. , vol.76 , pp. 3194-3198
    • Savran, C.A.1    Knudsen, S.M.2    Ellington, A.D.3    Manalis, S.R.4
  • 6
    • 30744473476 scopus 로고    scopus 로고
    • Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor
    • Radi A.-E., Sanchez J.L.A., Baldrich E., and O'sullivan C.K. Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor. J. Am. Chem. Soc. 128 (2006) 117-124
    • (2006) J. Am. Chem. Soc. , vol.128 , pp. 117-124
    • Radi, A.-E.1    Sanchez, J.L.A.2    Baldrich, E.3    O'sullivan, C.K.4
  • 7
    • 27444447802 scopus 로고    scopus 로고
    • A novel electrochemical detection method for aptamer biosensors
    • Bang G.S., Cho S., and Kim B.-G. A novel electrochemical detection method for aptamer biosensors. Biosens. Bioelectron. 21 (2005) 863-870
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 863-870
    • Bang, G.S.1    Cho, S.2    Kim, B.-G.3
  • 8
    • 33745699657 scopus 로고    scopus 로고
    • An electrochemical impedance immunosensor with signal amplification based on Au-colloid labeled antibody complex
    • Chen H., Jiang J.-H., Huang Y., Deng T., Li J.-S., Shen G.-L., and Yu R.-Q. An electrochemical impedance immunosensor with signal amplification based on Au-colloid labeled antibody complex. Sens. Actuator B 117 (2006) 211-218
    • (2006) Sens. Actuator B , vol.117 , pp. 211-218
    • Chen, H.1    Jiang, J.-H.2    Huang, Y.3    Deng, T.4    Li, J.-S.5    Shen, G.-L.6    Yu, R.-Q.7
  • 9
    • 33244480092 scopus 로고    scopus 로고
    • Label-free protein recognition using an aptamer-based impedance measurement assay
    • Cai H., Lee T.M.-H., and Hsing I.-M. Label-free protein recognition using an aptamer-based impedance measurement assay. Sens. Actuator B 114 (2006) 433-437
    • (2006) Sens. Actuator B , vol.114 , pp. 433-437
    • Cai, H.1    Lee, T.M.-H.2    Hsing, I.-M.3
  • 10
    • 33745686123 scopus 로고    scopus 로고
    • Label-free electrochemical detection of protein based on a ferrocene-bearing cationic polythiopene and aptamer
    • Le Floch F., Ho H.A., and Leclerc M. Label-free electrochemical detection of protein based on a ferrocene-bearing cationic polythiopene and aptamer. Anal. Chem. 78 (2006) 4727-4731
    • (2006) Anal. Chem. , vol.78 , pp. 4727-4731
    • Le Floch, F.1    Ho, H.A.2    Leclerc, M.3
  • 11
    • 33747302426 scopus 로고    scopus 로고
    • An aptamer-based protein biosensor by detecting the amplified impedance signal
    • Xu Y., Yang L., Ye X., He P., and Fang Y. An aptamer-based protein biosensor by detecting the amplified impedance signal. Electroanalysis 18 15 (2006) 1449-1456
    • (2006) Electroanalysis , vol.18 , Issue.15 , pp. 1449-1456
    • Xu, Y.1    Yang, L.2    Ye, X.3    He, P.4    Fang, Y.5
  • 12
    • 33746004891 scopus 로고    scopus 로고
    • Preparation and characterization of diethylene glycol bis(2-aminophenyl) ether-modified glassy carbon electrode
    • İsbir A.A., Solak A.O., Üstündaǧ Z., Bilge S., and Ki{dotless}li{dotless}ç Z. Preparation and characterization of diethylene glycol bis(2-aminophenyl) ether-modified glassy carbon electrode. Anal. Chim. Acta 573-574 (2006) 26-33
    • (2006) Anal. Chim. Acta , vol.573-574 , pp. 26-33
    • Isbir, A.A.1    Solak, A.O.2    Üstündaǧ, Z.3    Bilge, S.4    Kiliç, Z.5
  • 13
    • 33646255234 scopus 로고    scopus 로고
    • Development of novel glucose and pyruvate biosensors at poly(neutral red) modified carbon film electrodes. Application to natural samples
    • Ghica M.E., and Brett C.M.A. Development of novel glucose and pyruvate biosensors at poly(neutral red) modified carbon film electrodes. Application to natural samples. Electroanalysis 18 8 (2006) 748-756
    • (2006) Electroanalysis , vol.18 , Issue.8 , pp. 748-756
    • Ghica, M.E.1    Brett, C.M.A.2
  • 14
    • 18844425734 scopus 로고    scopus 로고
    • A novel method for the fabrication of high-aspect ratio C-MEMS structures
    • Wang C., Jia G., Taherabadi L.H., and Madou M.J. A novel method for the fabrication of high-aspect ratio C-MEMS structures. J. Microelectromech. Syst. 14 2 (2005) 348-358
    • (2005) J. Microelectromech. Syst. , vol.14 , Issue.2 , pp. 348-358
    • Wang, C.1    Jia, G.2    Taherabadi, L.H.3    Madou, M.J.4
  • 15
    • 14644442288 scopus 로고    scopus 로고
    • From MEMS to NEMS with carbon
    • Wang C., and Madou M.J. From MEMS to NEMS with carbon. Biosens. Bioelectron. 20 (2005) 2181-2187
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 2181-2187
    • Wang, C.1    Madou, M.J.2
  • 18
    • 0032712529 scopus 로고    scopus 로고
    • Fabrication of glassy carbon microstructures by soft lithography
    • Schueller O.J.A., Brittain S.T., and Whitesides G.M. Fabrication of glassy carbon microstructures by soft lithography. Sens. Actuators A 72 (1999) 125-139
    • (1999) Sens. Actuators A , vol.72 , pp. 125-139
    • Schueller, O.J.A.1    Brittain, S.T.2    Whitesides, G.M.3
  • 20
    • 0033888139 scopus 로고    scopus 로고
    • Photoresist-derived carbon for microelectromechanical systems and electrochemical applications
    • Ranganathan S., McCreery R., Majji S.M., and Madou M.J. Photoresist-derived carbon for microelectromechanical systems and electrochemical applications. J. Electrochem. Soc. 147 1 (2000) 277-282
    • (2000) J. Electrochem. Soc. , vol.147 , Issue.1 , pp. 277-282
    • Ranganathan, S.1    McCreery, R.2    Majji, S.M.3    Madou, M.J.4
  • 21
    • 0032121604 scopus 로고    scopus 로고
    • Electrochemical studies of carbon films from pyrolyzed photoresist
    • Kim J., Song X., Kinoshita K., Madou M.J., and White R. Electrochemical studies of carbon films from pyrolyzed photoresist. J. Electrochem. Soc. 145 7 (1998) 2314-2319
    • (1998) J. Electrochem. Soc. , vol.145 , Issue.7 , pp. 2314-2319
    • Kim, J.1    Song, X.2    Kinoshita, K.3    Madou, M.J.4    White, R.5
  • 22
    • 0042977319 scopus 로고    scopus 로고
    • Performance of pyrolyzed photoresist carbon films in a microchip capillary electrophoresis device with sinusoidal voltammetric detection
    • Hebert N.E., Snyder B., McCreery R.L., Kuhr W.G., and Brazill S.A. Performance of pyrolyzed photoresist carbon films in a microchip capillary electrophoresis device with sinusoidal voltammetric detection. Anal. Chem. 75 (2003) 4265-4271
    • (2003) Anal. Chem. , vol.75 , pp. 4265-4271
    • Hebert, N.E.1    Snyder, B.2    McCreery, R.L.3    Kuhr, W.G.4    Brazill, S.A.5
  • 23
    • 23844502985 scopus 로고    scopus 로고
    • Charge propagation in "ion channel sensors" based on protein-modified electrodes and redox marker ions
    • Schön P., Degefa T.H., Asaftei S., Meyer W., and Walder L. Charge propagation in "ion channel sensors" based on protein-modified electrodes and redox marker ions. J. Am. Chem. Soc. 127 32 (2005) 11486-11496
    • (2005) J. Am. Chem. Soc. , vol.127 , Issue.32 , pp. 11486-11496
    • Schön, P.1    Degefa, T.H.2    Asaftei, S.3    Meyer, W.4    Walder, L.5
  • 24
    • 0345158467 scopus 로고
    • Anormalously slow electron transfer at ordered graphite electrodes: influence of electronic factors and reactive sites
    • Cline K.K., McDermott M.T., and McCreery R.L. Anormalously slow electron transfer at ordered graphite electrodes: influence of electronic factors and reactive sites. J. Phys. Chem. 98 20 (1994) 5314-5319
    • (1994) J. Phys. Chem. , vol.98 , Issue.20 , pp. 5314-5319
    • Cline, K.K.1    McDermott, M.T.2    McCreery, R.L.3
  • 25
    • 11944258101 scopus 로고
    • Quantitative correlations of heterogeneous electron-transfer kinetics with surface properties of glassy carbon electrodes
    • Rice R.J., Pontikos N.M., and McCreery R.M. Quantitative correlations of heterogeneous electron-transfer kinetics with surface properties of glassy carbon electrodes. J. Am. Chem. Soc. 112 12 (1990) 4617-4622
    • (1990) J. Am. Chem. Soc. , vol.112 , Issue.12 , pp. 4617-4622
    • Rice, R.J.1    Pontikos, N.M.2    McCreery, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.