메뉴 건너뛰기




Volumn 16, Issue 6, 2006, Pages 586-602

Clinical applications of high-density surface EMG: A systematic review

Author keywords

High density surface EMG; High spatial resolution surface EMG; Multi channel EMG; Review

Indexed keywords

BIOENGINEERING; CHRONIC FATIGUE SYNDROME; DIAGNOSTIC PROCEDURE; ELECTRODE; ELECTROMYOGRAM; ELECTROMYOGRAPHY; EQUIPMENT; HUMAN; MOTOR NEURON DISEASE; MOTOR UNIT; MOTOR UNIT POTENTIAL; MUSCLE CHARACTERISTICS AND FUNCTIONS; MUSCLE CONTRACTION; MUSCLE FATIGUE; MYOELECTRICITY; MYOPATHY; NERVE CONDUCTION; NEUROPATHY; PRIORITY JOURNAL; REVIEW; SYSTEMATIC REVIEW;

EID: 33750526883     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2006.09.005     Document Type: Review
Times cited : (236)

References (171)
  • 1
    • 0024598713 scopus 로고
    • Measurement of muscle fiber conduction velocity in humans: techniques and applications
    • Arendt-Nielsen L., and Zwarts M. Measurement of muscle fiber conduction velocity in humans: techniques and applications. J Clin Neurophysiol 6 (1989) 173-190
    • (1989) J Clin Neurophysiol , vol.6 , pp. 173-190
    • Arendt-Nielsen, L.1    Zwarts, M.2
  • 2
    • 0026656617 scopus 로고
    • The influence of muscle length on muscle-fiber conduction-velocity and development of muscle fatigue
    • Arendt-Nielsen L., Gantchev N., and Sinkjaer T. The influence of muscle length on muscle-fiber conduction-velocity and development of muscle fatigue. Electroencephalogr Clin Neurophysiol 85 (1992) 166-172
    • (1992) Electroencephalogr Clin Neurophysiol , vol.85 , pp. 166-172
    • Arendt-Nielsen, L.1    Gantchev, N.2    Sinkjaer, T.3
  • 4
    • 0042973848 scopus 로고    scopus 로고
    • High spatial resolution electromyography and video-assisted movement analysis in children with obstetric brachial plexus palsy
    • Bahm J., Meinecke L., Brandenbusch V., Rau G., and Disselhorst-Klug C. High spatial resolution electromyography and video-assisted movement analysis in children with obstetric brachial plexus palsy. Hand Clin 19 (2003) 393
    • (2003) Hand Clin , vol.19 , pp. 393
    • Bahm, J.1    Meinecke, L.2    Brandenbusch, V.3    Rau, G.4    Disselhorst-Klug, C.5
  • 5
    • 16444385787 scopus 로고    scopus 로고
    • A technique to track individual motor unit action potentials in surface EMG by monitoring their conduction velocities and amplitudes
    • Beck R.B.J., Houtman C.J., O'Malley M.J., Lowery M.M., and Stegeman D.F. A technique to track individual motor unit action potentials in surface EMG by monitoring their conduction velocities and amplitudes. IEEE Trans Biomed Eng 52 (2005) 622-629
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 622-629
    • Beck, R.B.J.1    Houtman, C.J.2    O'Malley, M.J.3    Lowery, M.M.4    Stegeman, D.F.5
  • 6
    • 0035988865 scopus 로고    scopus 로고
    • Three-layer volume conductor model and software package for applications in surface electromyography
    • Blok J.H., Stegeman D.F., and van O.A. Three-layer volume conductor model and software package for applications in surface electromyography. Ann Biomed Eng 30 (2002) 566-577
    • (2002) Ann Biomed Eng , vol.30 , pp. 566-577
    • Blok, J.H.1    Stegeman, D.F.2    van, O.A.3
  • 7
    • 0036541293 scopus 로고    scopus 로고
    • A high-density multichannel surface electromyography system for the characterization of single motor units
    • Blok J.H., Van Dijk J.P., Drost G., Zwarts M.J., and Stegeman D.F. A high-density multichannel surface electromyography system for the characterization of single motor units. Rev Scientific Instrum 73 (2002) 1887-1897
    • (2002) Rev Scientific Instrum , vol.73 , pp. 1887-1897
    • Blok, J.H.1    Van Dijk, J.P.2    Drost, G.3    Zwarts, M.J.4    Stegeman, D.F.5
  • 8
    • 24144453535 scopus 로고    scopus 로고
    • Motor unit action potential topography and its use in motor unit number estimation
    • Blok J.H., Van Dijk J.P., Zwarts M.J., and Stegeman D.F. Motor unit action potential topography and its use in motor unit number estimation. Muscle Nerve 32 (2005) 280-291
    • (2005) Muscle Nerve , vol.32 , pp. 280-291
    • Blok, J.H.1    Van Dijk, J.P.2    Zwarts, M.J.3    Stegeman, D.F.4
  • 9
    • 10744223610 scopus 로고    scopus 로고
    • Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative43
    • Bossuyt P.M., Reitsma J.B., Bruns D.E., Gatsonis C.A., Glasziou P.P., Irwig L.M., et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative43. Ann Clin Biochem 40 (2003) 357-363
    • (2003) Ann Clin Biochem , vol.40 , pp. 357-363
    • Bossuyt, P.M.1    Reitsma, J.B.2    Bruns, D.E.3    Gatsonis, C.A.4    Glasziou, P.P.5    Irwig, L.M.6
  • 11
    • 20044394566 scopus 로고    scopus 로고
    • Surface EMG of jaw elevator muscles: effect of electrode location and inter-electrode distance
    • Castroflorio T., Farina D., Bottin A., Piancino M.G., Bracco P., and Merletti R. Surface EMG of jaw elevator muscles: effect of electrode location and inter-electrode distance. J Oral Rehabil 32 (2005) 411-417
    • (2005) J Oral Rehabil , vol.32 , pp. 411-417
    • Castroflorio, T.1    Farina, D.2    Bottin, A.3    Piancino, M.G.4    Bracco, P.5    Merletti, R.6
  • 12
    • 4444355445 scopus 로고    scopus 로고
    • Non-invasive assessment of single motor unit mechanomyographic response and twitch force by spike-triggered averaging
    • Cescon C., Gazzoni M., Gobbo M., Orizio C., and Farina D. Non-invasive assessment of single motor unit mechanomyographic response and twitch force by spike-triggered averaging. Med Biol Eng Comput 42 (2004) 496-501
    • (2004) Med Biol Eng Comput , vol.42 , pp. 496-501
    • Cescon, C.1    Gazzoni, M.2    Gobbo, M.3    Orizio, C.4    Farina, D.5
  • 13
    • 29144513816 scopus 로고    scopus 로고
    • Non-invasive characterization of single motor unit electromyographic and mechanomyographic activities in the biceps brachii muscle
    • Cescon C., Sguazzi E., Merletti R., and Farina D. Non-invasive characterization of single motor unit electromyographic and mechanomyographic activities in the biceps brachii muscle. J Electromyogr Kinesiol 16 (2006) 17-24
    • (2006) J Electromyogr Kinesiol , vol.16 , pp. 17-24
    • Cescon, C.1    Sguazzi, E.2    Merletti, R.3    Farina, D.4
  • 14
    • 0344237419 scopus 로고    scopus 로고
    • Automatic identification of motor unit action potential trains from electromyographic signals using fuzzy techniques
    • Chauvet E., Fokapu O., Hogrel J.Y., Gamet D., and Duchene J. Automatic identification of motor unit action potential trains from electromyographic signals using fuzzy techniques. Med Biol Eng Comput 41 (2003) 646-653
    • (2003) Med Biol Eng Comput , vol.41 , pp. 646-653
    • Chauvet, E.1    Fokapu, O.2    Hogrel, J.Y.3    Gamet, D.4    Duchene, J.5
  • 15
    • 0031171420 scopus 로고    scopus 로고
    • Spatio-temporal representation of multichannel EMG firing patterns and its clinical applications
    • Chen J.J., Sun T.Y., Lin T.H., and Lin T.S. Spatio-temporal representation of multichannel EMG firing patterns and its clinical applications. Med Eng Phys 19 (1997) 420-430
    • (1997) Med Eng Phys , vol.19 , pp. 420-430
    • Chen, J.J.1    Sun, T.Y.2    Lin, T.H.3    Lin, T.S.4
  • 16
    • 0033051927 scopus 로고    scopus 로고
    • Surface EMG recorded by branched electrodes during sustained muscle activity
    • Christova P., Kossev A., Kristev I., and Chichov V. Surface EMG recorded by branched electrodes during sustained muscle activity. J Electromyogr Kinesiol 9 (1999) 263-276
    • (1999) J Electromyogr Kinesiol , vol.9 , pp. 263-276
    • Christova, P.1    Kossev, A.2    Kristev, I.3    Chichov, V.4
  • 18
    • 0034949718 scopus 로고    scopus 로고
    • Effect of parameters altering with muscle fibre functional state on power spectra of spatially filtered extracellular potentials
    • Dimitrov G.V., and Dimitrova N.A. Effect of parameters altering with muscle fibre functional state on power spectra of spatially filtered extracellular potentials. J Med Eng Techn 25 (2001) 74-78
    • (2001) J Med Eng Techn , vol.25 , pp. 74-78
    • Dimitrov, G.V.1    Dimitrova, N.A.2
  • 19
    • 0035054730 scopus 로고    scopus 로고
    • Longitudinal variations of characteristic frequencies of skeletal muscle fibre potentials detected by a bipolar electrode or multi-electrode
    • Dimitrova N.A., Dimitrov G.V., and Nikitin A. Longitudinal variations of characteristic frequencies of skeletal muscle fibre potentials detected by a bipolar electrode or multi-electrode. J Med Eng Techn 25 (2001) 34-40
    • (2001) J Med Eng Techn , vol.25 , pp. 34-40
    • Dimitrova, N.A.1    Dimitrov, G.V.2    Nikitin, A.3
  • 20
    • 12244258272 scopus 로고    scopus 로고
    • Simulation analysis of the ability of different types of multi-electrodes to increase selectivity of detection and to reduce cross-talk
    • Dimitrov G.V., Disselhorst-Klug C., Dimitrova N.A., Schulte E., and Rau G. Simulation analysis of the ability of different types of multi-electrodes to increase selectivity of detection and to reduce cross-talk. J Electromyogr Kinesiol 13 (2003) 125-138
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 125-138
    • Dimitrov, G.V.1    Disselhorst-Klug, C.2    Dimitrova, N.A.3    Schulte, E.4    Rau, G.5
  • 21
    • 0031195287 scopus 로고    scopus 로고
    • Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters
    • DisselhorstKlug C., Silny J., and Rau G. Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters. IEEE Trans Biomed Eng 44 (1997) 567-574
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 567-574
    • DisselhorstKlug, C.1    Silny, J.2    Rau, G.3
  • 22
    • 0032190889 scopus 로고    scopus 로고
    • Estimation of the relationship between the noninvasively detected activity of single motor units and their characteristic pathological changes by modelling
    • DisselhorstKlug C., Silny J., and Rau G. Estimation of the relationship between the noninvasively detected activity of single motor units and their characteristic pathological changes by modelling. J Electromyogr Kinesiol 8 (1998) 323-335
    • (1998) J Electromyogr Kinesiol , vol.8 , pp. 323-335
    • DisselhorstKlug, C.1    Silny, J.2    Rau, G.3
  • 23
    • 0032948473 scopus 로고    scopus 로고
    • Non-invasive detection of the single motor unit action potential by averaging the spatial potential distribution triggered on a spatially filtered motor unit action potential
    • DisselhorstKlug C., Rau G., Schmeer A., and Silny J. Non-invasive detection of the single motor unit action potential by averaging the spatial potential distribution triggered on a spatially filtered motor unit action potential. J Electromyogr Kinesiol 9 (1999) 67-72
    • (1999) J Electromyogr Kinesiol , vol.9 , pp. 67-72
    • DisselhorstKlug, C.1    Rau, G.2    Schmeer, A.3    Silny, J.4
  • 24
    • 0034533623 scopus 로고    scopus 로고
    • Non-invasive approach of motor unit recording during muscle contractions in humans
    • DisselhorstKlug C., Bahm J., Ramaekers V., Trachterna A., and Rau G. Non-invasive approach of motor unit recording during muscle contractions in humans. Eur J Appl Physiol 83 (2000) 144-150
    • (2000) Eur J Appl Physiol , vol.83 , pp. 144-150
    • DisselhorstKlug, C.1    Bahm, J.2    Ramaekers, V.3    Trachterna, A.4    Rau, G.5
  • 25
    • 0035125982 scopus 로고    scopus 로고
    • Propagation disturbance of motor unit action potentials during transient paresis in generalized myotonia: a high-density surface EMG study
    • Drost G., Blok J.H., Stegeman D.F., Van Dijk J.P., Van Engelen B.G., and Zwarts M.J. Propagation disturbance of motor unit action potentials during transient paresis in generalized myotonia: a high-density surface EMG study. Brain 124 (2001) 352-360
    • (2001) Brain , vol.124 , pp. 352-360
    • Drost, G.1    Blok, J.H.2    Stegeman, D.F.3    Van Dijk, J.P.4    Van Engelen, B.G.5    Zwarts, M.J.6
  • 26
    • 4243169183 scopus 로고    scopus 로고
    • Motor unit characteristics in healthy subjects and those with postpoliomyelitis syndrome: a high-density surface EMG study
    • Drost G., Stegeman D.F., Schillings M.L., Horemans H.L., Janssen H.M., Massa M., et al. Motor unit characteristics in healthy subjects and those with postpoliomyelitis syndrome: a high-density surface EMG study. Muscle Nerve 30 (2004) 269-276
    • (2004) Muscle Nerve , vol.30 , pp. 269-276
    • Drost, G.1    Stegeman, D.F.2    Schillings, M.L.3    Horemans, H.L.4    Janssen, H.M.5    Massa, M.6
  • 27
    • 3543053480 scopus 로고    scopus 로고
    • Maintaining constant voluntary force in generalized myotonia despite muscle membrane disturbances: insights from a high-density surface EMG study
    • Drost G., Van Dijk J.P., Stegeman D.F., Van Engelen B.G., and Zwarts M.J. Maintaining constant voluntary force in generalized myotonia despite muscle membrane disturbances: insights from a high-density surface EMG study. J Clin Neurophysiol 21 (2004) 114-123
    • (2004) J Clin Neurophysiol , vol.21 , pp. 114-123
    • Drost, G.1    Van Dijk, J.P.2    Stegeman, D.F.3    Van Engelen, B.G.4    Zwarts, M.J.5
  • 28
    • 1442280300 scopus 로고    scopus 로고
    • Glutamic acid decarboxylase antibodies in Satoyoshi syndrome
    • Drost G., Verrips A., Hooijkaas H., and Zwarts M. Glutamic acid decarboxylase antibodies in Satoyoshi syndrome. Ann Neurol 55 (2004) 450-451
    • (2004) Ann Neurol , vol.55 , pp. 450-451
    • Drost, G.1    Verrips, A.2    Hooijkaas, H.3    Zwarts, M.4
  • 29
    • 33845226601 scopus 로고    scopus 로고
    • Drost G, Verrips A, Van Engelen BGM, Stegeman DF, Zwarts M. Involuntary painful muscle contractions in Satoyoshi syndrome. A surface EMG study. Movement Disorders 2006 [in press].
  • 30
    • 33750504108 scopus 로고    scopus 로고
    • Drost G, Kleine BU, Stegeman DF, Van Engelen BGM, Zwarts M. Fasciculation potentials in high-density suface EMG [submitted for publication].
  • 31
    • 0036095482 scopus 로고    scopus 로고
    • The correlation between muscle and nerve fiber conduction velocities in thenar muscle is lost in case of carpal tunnel syndrome
    • El Dassouki M., and Lefaucheur J.P. The correlation between muscle and nerve fiber conduction velocities in thenar muscle is lost in case of carpal tunnel syndrome. Clin Neurophysiol 113 (2002) 1121-1124
    • (2002) Clin Neurophysiol , vol.113 , pp. 1121-1124
    • El Dassouki, M.1    Lefaucheur, J.P.2
  • 32
    • 2642536745 scopus 로고    scopus 로고
    • Functional asymmetry of pelvic floor innervation and its role in the pathogenesis of fecal incontinence
    • Enck P., Hinninghofen H., Wietek B., and Becker H.D. Functional asymmetry of pelvic floor innervation and its role in the pathogenesis of fecal incontinence. Digestion 69 (2004) 102-111
    • (2004) Digestion , vol.69 , pp. 102-111
    • Enck, P.1    Hinninghofen, H.2    Wietek, B.3    Becker, H.D.4
  • 33
    • 19944368757 scopus 로고    scopus 로고
    • The external anal sphincter and the role of surface electromyography
    • Enck P., Hinninghofen H., Merletti R., and Azpiroz F. The external anal sphincter and the role of surface electromyography. Neurogastroenterol Motil 17 Suppl. 1 (2005) 60-67
    • (2005) Neurogastroenterol Motil , vol.17 , Issue.SUPPL. 1 , pp. 60-67
    • Enck, P.1    Hinninghofen, H.2    Merletti, R.3    Azpiroz, F.4
  • 34
    • 20444438650 scopus 로고    scopus 로고
    • Muscle fiber conduction velocity of the upper trapezius muscle during dynamic contraction of the upper limb in patients with chronic neck pain
    • Falla D., and Farina D. Muscle fiber conduction velocity of the upper trapezius muscle during dynamic contraction of the upper limb in patients with chronic neck pain. Pain 116 (2005) 138-145
    • (2005) Pain , vol.116 , pp. 138-145
    • Falla, D.1    Farina, D.2
  • 35
    • 0036153336 scopus 로고    scopus 로고
    • Location of innervation zones of sternocleidomastoid and scalene muscles-a basis for clinical and research electromyography applications
    • Falla D., Dall'Alba P., Rainoldi A., Merletti R., and Jull G. Location of innervation zones of sternocleidomastoid and scalene muscles-a basis for clinical and research electromyography applications. Clin Neurophysiol 113 (2002) 57-63
    • (2002) Clin Neurophysiol , vol.113 , pp. 57-63
    • Falla, D.1    Dall'Alba, P.2    Rainoldi, A.3    Merletti, R.4    Jull, G.5
  • 36
    • 0034773771 scopus 로고    scopus 로고
    • Concentric-ring electrode systems for noninvasive detection of single motor unit activity
    • Farina D., and Cescon C. Concentric-ring electrode systems for noninvasive detection of single motor unit activity. IEEE Trans Biomed Eng 48 (2001) 1326-1334
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 1326-1334
    • Farina, D.1    Cescon, C.2
  • 37
    • 0034986783 scopus 로고    scopus 로고
    • A novel approach for precise simulation of the EMG signal detected by surface electrodes
    • Farina D., and Merletti R. A novel approach for precise simulation of the EMG signal detected by surface electrodes. IEEE Trans Biomed Eng 48 (2001) 637-646
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 637-646
    • Farina, D.1    Merletti, R.2
  • 38
    • 1542285321 scopus 로고    scopus 로고
    • Estimation of average muscle fiber conduction velocity from two-dimensional surface EMG recordings
    • Farina D., and Merletti R. Estimation of average muscle fiber conduction velocity from two-dimensional surface EMG recordings. J Neuroscience Methods 134 (2004) 199-208
    • (2004) J Neuroscience Methods , vol.134 , pp. 199-208
    • Farina, D.1    Merletti, R.2
  • 39
    • 12344310125 scopus 로고    scopus 로고
    • Sensitivity of surface EMG-based conduction velocity estimates to local tissue in -homogeneities - influence of the number of channels and inter-channel distance
    • Farina D., and Mesin L. Sensitivity of surface EMG-based conduction velocity estimates to local tissue in -homogeneities - influence of the number of channels and inter-channel distance. J Neurosci Methods 142 (2005) 83-89
    • (2005) J Neurosci Methods , vol.142 , pp. 83-89
    • Farina, D.1    Mesin, L.2
  • 40
    • 0034015483 scopus 로고    scopus 로고
    • Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays
    • Farina D., Fortunato E., and Merletti R. Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays. IEEE Trans Biomed Eng 47 (2000) 380-388
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 380-388
    • Farina, D.1    Fortunato, E.2    Merletti, R.3
  • 41
    • 0035047686 scopus 로고    scopus 로고
    • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays
    • Farina D., Muhammad W., Fortunato E., Meste O., Merletti R., and Rix H. Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays. Med Biol Eng Comput 39 (2001) 225-236
    • (2001) Med Biol Eng Comput , vol.39 , pp. 225-236
    • Farina, D.1    Muhammad, W.2    Fortunato, E.3    Meste, O.4    Merletti, R.5    Rix, H.6
  • 42
    • 0036594937 scopus 로고    scopus 로고
    • Influence of anatomical, physical, and detection-system parameters on surface EMG
    • Farina D., Cescon C., and Merletti R. Influence of anatomical, physical, and detection-system parameters on surface EMG. Biol Cybernet 86 (2002) 445-456
    • (2002) Biol Cybernet , vol.86 , pp. 445-456
    • Farina, D.1    Cescon, C.2    Merletti, R.3
  • 43
    • 0036092520 scopus 로고    scopus 로고
    • Motor unit recruitment strategies investigated by surface EMG variables
    • Farina D., Fosci M., and Merletti R. Motor unit recruitment strategies investigated by surface EMG variables. J Appl Physiol 92 (2002) 235-247
    • (2002) J Appl Physiol , vol.92 , pp. 235-247
    • Farina, D.1    Fosci, M.2    Merletti, R.3
  • 44
    • 0036842126 scopus 로고    scopus 로고
    • Surface EMG crosstalk between knee extensor muscles: experimental and model results
    • Farina D., Merletti R., Indino B., Nazzaro M., and Pozzo M. Surface EMG crosstalk between knee extensor muscles: experimental and model results. Muscle Nerve 26 (2002) 681-695
    • (2002) Muscle Nerve , vol.26 , pp. 681-695
    • Farina, D.1    Merletti, R.2    Indino, B.3    Nazzaro, M.4    Pozzo, M.5
  • 45
    • 0037196868 scopus 로고    scopus 로고
    • Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging
    • Farina D., Arendt-Nielsen L., Merletti R., and Graven-Nielsen T. Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging. J Neurosci Methods 115 (2002) 1-12
    • (2002) J Neurosci Methods , vol.115 , pp. 1-12
    • Farina, D.1    Arendt-Nielsen, L.2    Merletti, R.3    Graven-Nielsen, T.4
  • 47
    • 0037842707 scopus 로고    scopus 로고
    • Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: spatial selectivity
    • Farina D., Schulte E., Merletti R., Rau G., and Disselhorst-Klug C. Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: spatial selectivity. Med Biol Eng Comput 41 (2003) 330-337
    • (2003) Med Biol Eng Comput , vol.41 , pp. 330-337
    • Farina, D.1    Schulte, E.2    Merletti, R.3    Rau, G.4    Disselhorst-Klug, C.5
  • 48
    • 1642415267 scopus 로고    scopus 로고
    • Blind separation of linear instantaneous mixtures of nonstationary surface myoelectric signals
    • Farina D., Fevotte C., Doncarli C., and Merletti R. Blind separation of linear instantaneous mixtures of nonstationary surface myoelectric signals. IEEE Trans Biomed Eng 51 (2004) 1555-1567
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 1555-1567
    • Farina, D.1    Fevotte, C.2    Doncarli, C.3    Merletti, R.4
  • 49
    • 1642270491 scopus 로고    scopus 로고
    • Low-threshold motor unit membrane properties vary with contraction intensity during sustained activation with surface EMG visual feedback
    • Farina D., Gazzoni M., and Camelia F. Low-threshold motor unit membrane properties vary with contraction intensity during sustained activation with surface EMG visual feedback. J Appl Physiol 96 (2004) 1505-1515
    • (2004) J Appl Physiol , vol.96 , pp. 1505-1515
    • Farina, D.1    Gazzoni, M.2    Camelia, F.3
  • 50
    • 1642337026 scopus 로고    scopus 로고
    • The extraction of neural strategies from the surface EMG
    • Farina D., Merletti R., and Enoka R.M. The extraction of neural strategies from the surface EMG. J Appl Physiol 96 (2004) 1486-1495
    • (2004) J Appl Physiol , vol.96 , pp. 1486-1495
    • Farina, D.1    Merletti, R.2    Enoka, R.M.3
  • 51
    • 4444342026 scopus 로고    scopus 로고
    • Advances in surface electromyographic signal simulation with analytical and numerical descriptions of the volume conductor
    • Farina D., Mesin L., and Martina S. Advances in surface electromyographic signal simulation with analytical and numerical descriptions of the volume conductor. Med Biol Eng Comput 42 (2004) 467-476
    • (2004) Med Biol Eng Comput , vol.42 , pp. 467-476
    • Farina, D.1    Mesin, L.2    Martina, S.3
  • 52
    • 1242321163 scopus 로고    scopus 로고
    • A surface EMG generation model with multilayer cylindrical description of the volume conductor
    • Farina D., Mesin L., Martina S., and Merletti R. A surface EMG generation model with multilayer cylindrical description of the volume conductor. IEEE Trans Biomed Eng 51 (2004) 415-426
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 415-426
    • Farina, D.1    Mesin, L.2    Martina, S.3    Merletti, R.4
  • 53
    • 1042268833 scopus 로고    scopus 로고
    • Comparison of spatial filter selectivity in surface myoelectric signal detection: influence of the volume conductor model
    • Farina D., Mesin L., Martina S., and Merletti R. Comparison of spatial filter selectivity in surface myoelectric signal detection: influence of the volume conductor model. Med Biol Eng Comput 42 (2004) 114-120
    • (2004) Med Biol Eng Comput , vol.42 , pp. 114-120
    • Farina, D.1    Mesin, L.2    Martina, S.3    Merletti, R.4
  • 54
    • 2942553128 scopus 로고    scopus 로고
    • Assessment of average muscle fiber conduction velocity from surface EMG signals during fatiguing dynamic contractions
    • Farina D., Pozzo M., Merlo E., Bottin A., and Merletti R. Assessment of average muscle fiber conduction velocity from surface EMG signals during fatiguing dynamic contractions. IEEE Trans Biomed Eng 51 (2004) 1383-1393
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 1383-1393
    • Farina, D.1    Pozzo, M.2    Merlo, E.3    Bottin, A.4    Merletti, R.5
  • 55
    • 0842304502 scopus 로고    scopus 로고
    • Reproducibility of muscle-fiber conduction velocity estimates using multichannel surface EMG techniques
    • Farina D., Zagari D., Gazzoni M., and Merletti R. Reproducibility of muscle-fiber conduction velocity estimates using multichannel surface EMG techniques. Muscle Nerve 29 (2004) 282-291
    • (2004) Muscle Nerve , vol.29 , pp. 282-291
    • Farina, D.1    Zagari, D.2    Gazzoni, M.3    Merletti, R.4
  • 56
    • 15444367111 scopus 로고    scopus 로고
    • Conduction velocity of low-threshold motor units during ischemic contractions performed with surface EMG feedback
    • Farina D., Gazzoni M., and Camelia F. Conduction velocity of low-threshold motor units during ischemic contractions performed with surface EMG feedback. J Appl Physiol 98 (2005) 1487-1494
    • (2005) J Appl Physiol , vol.98 , pp. 1487-1494
    • Farina, D.1    Gazzoni, M.2    Camelia, F.3
  • 57
    • 20444415593 scopus 로고    scopus 로고
    • Experimental muscle pain decreases voluntary EMG activity but does not affect the muscle potential evoked by transcutaneous electrical stimulation
    • Farina D., Arendt-Nielsen L., and Graven-Nielsen T. Experimental muscle pain decreases voluntary EMG activity but does not affect the muscle potential evoked by transcutaneous electrical stimulation. Clin Neurophysiol 116 (2005) 1558-1565
    • (2005) Clin Neurophysiol , vol.116 , pp. 1558-1565
    • Farina, D.1    Arendt-Nielsen, L.2    Graven-Nielsen, T.3
  • 58
    • 14144256762 scopus 로고    scopus 로고
    • Experimental muscle pain reduces initial motor unit discharge rates during sustained submaximal contractions
    • Farina D., Arendt-Nielsen L., and Graven-Nielsen T. Experimental muscle pain reduces initial motor unit discharge rates during sustained submaximal contractions. J Appl Physiol 98 (2005) 999-1005
    • (2005) J Appl Physiol , vol.98 , pp. 999-1005
    • Farina, D.1    Arendt-Nielsen, L.2    Graven-Nielsen, T.3
  • 59
    • 15444367422 scopus 로고    scopus 로고
    • Spike-triggered average torque and muscle fiber conduction velocity of low-threshold motor units following submaximal endurance contractions
    • Farina D., Arendt-Nielsen L., and Graven-Nielsen T. Spike-triggered average torque and muscle fiber conduction velocity of low-threshold motor units following submaximal endurance contractions. J Appl Physiol 98 (2005) 1495-1502
    • (2005) J Appl Physiol , vol.98 , pp. 1495-1502
    • Farina, D.1    Arendt-Nielsen, L.2    Graven-Nielsen, T.3
  • 60
    • 16244417784 scopus 로고    scopus 로고
    • Influence of high motor unit synchronization levels on non-linear and spectral variables of the surface EMG
    • Fattorini L., Felici F., Filligoi G.C., Traballesi M., and Farina D. Influence of high motor unit synchronization levels on non-linear and spectral variables of the surface EMG. J Neurosci Methods 143 (2005) 133-139
    • (2005) J Neurosci Methods , vol.143 , pp. 133-139
    • Fattorini, L.1    Felici, F.2    Filligoi, G.C.3    Traballesi, M.4    Farina, D.5
  • 61
    • 23044503830 scopus 로고    scopus 로고
    • A decomposition algorithm for surface electrode-array electromyogram. A noninvasive, three-step approach to analyze surface EMG signals
    • Garcia G.A., Okuno R., and Akazawa K. A decomposition algorithm for surface electrode-array electromyogram. A noninvasive, three-step approach to analyze surface EMG signals. IEEE Eng Med Biol Mag 24 (2005) 63-72
    • (2005) IEEE Eng Med Biol Mag , vol.24 , pp. 63-72
    • Garcia, G.A.1    Okuno, R.2    Akazawa, K.3
  • 62
    • 2942564121 scopus 로고    scopus 로고
    • A new method for the extraction and classification of single motor unit action potentials from surface EMG signals
    • Gazzoni M., Farina D., and Merletti R. A new method for the extraction and classification of single motor unit action potentials from surface EMG signals. J Neurosci Methods 136 (2004) 165-177
    • (2004) J Neurosci Methods , vol.136 , pp. 165-177
    • Gazzoni, M.1    Farina, D.2    Merletti, R.3
  • 63
    • 33750506809 scopus 로고
    • Application of a surface electrode array in the measurement of Emg activity during masticatory function
    • Geister D.E., Steusloff P.M., and Ash M.M. Application of a surface electrode array in the measurement of Emg activity during masticatory function. J Dental Res 59 (1980) 487
    • (1980) J Dental Res , vol.59 , pp. 487
    • Geister, D.E.1    Steusloff, P.M.2    Ash, M.M.3
  • 64
    • 0025877398 scopus 로고
    • Hypoxia reduces the conduction velocity of the excitation along the striated muscles in man
    • Gerilovsky L., Karadimov D., and Ianakiev B. Hypoxia reduces the conduction velocity of the excitation along the striated muscles in man. Electromyogr Clin Neurophysiol 31 (1991) 203-208
    • (1991) Electromyogr Clin Neurophysiol , vol.31 , pp. 203-208
    • Gerilovsky, L.1    Karadimov, D.2    Ianakiev, B.3
  • 65
    • 0345528197 scopus 로고    scopus 로고
    • Selective spatial information from surface EMG after temporal filtering: the application to interference EMG using cross-covariance analysis
    • Grassme R., Stegeman D.F., Drost G., Schumann N.P., and Scholle H.C. Selective spatial information from surface EMG after temporal filtering: the application to interference EMG using cross-covariance analysis. Clin Neurophysiol 114 (2003) 2338-2346
    • (2003) Clin Neurophysiol , vol.114 , pp. 2338-2346
    • Grassme, R.1    Stegeman, D.F.2    Drost, G.3    Schumann, N.P.4    Scholle, H.C.5
  • 66
    • 14044251554 scopus 로고    scopus 로고
    • Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogram
    • Gronlund C., Ostlund N., Roeleveld K., and Karlsson J.S. Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogram. Med Biol Eng Comput 43 (2005) 63-70
    • (2005) Med Biol Eng Comput , vol.43 , pp. 63-70
    • Gronlund, C.1    Ostlund, N.2    Roeleveld, K.3    Karlsson, J.S.4
  • 67
    • 22544475301 scopus 로고    scopus 로고
    • On-line signal quality estimation of multichannel surface electromyograms
    • Gronlund C., Roeleveld K., Holtermann A., and Karlsson J.S. On-line signal quality estimation of multichannel surface electromyograms. Med Biol Eng Comput 43 (2005) 357-364
    • (2005) Med Biol Eng Comput , vol.43 , pp. 357-364
    • Gronlund, C.1    Roeleveld, K.2    Holtermann, A.3    Karlsson, J.S.4
  • 68
    • 0027732469 scopus 로고
    • Action-potential velocity-measurements in the upper trapezius muscle
    • Hagg G.M. Action-potential velocity-measurements in the upper trapezius muscle. J Electromyogr Kinesiol 3 (1993) 231-235
    • (1993) J Electromyogr Kinesiol , vol.3 , pp. 231-235
    • Hagg, G.M.1
  • 69
    • 0030060772 scopus 로고    scopus 로고
    • Technology assessment: the use of surface EMG in the diagnosis and treatment of nerve and muscle disorders46
    • Haig A.J., Gelblum J.B., Rechtien J.J., and Gitter A.J. Technology assessment: the use of surface EMG in the diagnosis and treatment of nerve and muscle disorders46. Muscle Nerve 19 (1996) 392-395
    • (1996) Muscle Nerve , vol.19 , pp. 392-395
    • Haig, A.J.1    Gelblum, J.B.2    Rechtien, J.J.3    Gitter, A.J.4
  • 70
    • 0028042905 scopus 로고
    • Recovery of conduction velocity of muscle fiber action potential after strenuous isometric contraction
    • Hanayama K. Recovery of conduction velocity of muscle fiber action potential after strenuous isometric contraction. Jpn J Physiol 44 (1994) 75-88
    • (1994) Jpn J Physiol , vol.44 , pp. 75-88
    • Hanayama, K.1
  • 71
    • 0019557819 scopus 로고
    • Optimizing the acquisition and processing of surface electromyographic signals
    • Harba M.I., and Lynn P.A. Optimizing the acquisition and processing of surface electromyographic signals. J Biomed Eng 3 (1981) 100-106
    • (1981) J Biomed Eng , vol.3 , pp. 100-106
    • Harba, M.I.1    Lynn, P.A.2
  • 72
    • 0032618201 scopus 로고    scopus 로고
    • Reliability of measurement of muscle fiber conduction velocity using surface EMG
    • Harba M.I., and Teng L.Y. Reliability of measurement of muscle fiber conduction velocity using surface EMG. Front Med Biol Eng 9 (1999) 31-47
    • (1999) Front Med Biol Eng , vol.9 , pp. 31-47
    • Harba, M.I.1    Teng, L.Y.2
  • 73
    • 0033813270 scopus 로고    scopus 로고
    • Development of recommendations for SEMG sensors and sensor placement procedures
    • Hermens H.J., Freriks B., sselhorst-Klug C., and Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol 10 (2000) 361-374
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 361-374
    • Hermens, H.J.1    Freriks, B.2    sselhorst-Klug, C.3    Rau, G.4
  • 74
    • 0021352037 scopus 로고
    • Normal and myopathic propagation of surface motor unit action potentials
    • Hilfiker P., and Meyer M. Normal and myopathic propagation of surface motor unit action potentials. Electroencephalogr Clin Neurophysiol 57 (1984) 21-31
    • (1984) Electroencephalogr Clin Neurophysiol , vol.57 , pp. 21-31
    • Hilfiker, P.1    Meyer, M.2
  • 75
    • 23444437626 scopus 로고    scopus 로고
    • Clinical applications of surface electromyography in neuromuscular disorders
    • Hogrel J.Y. Clinical applications of surface electromyography in neuromuscular disorders. Neurophysiol Clin 35 (2005) 59-71
    • (2005) Neurophysiol Clin , vol.35 , pp. 59-71
    • Hogrel, J.Y.1
  • 76
    • 12444279103 scopus 로고    scopus 로고
    • Inhomogeneities in muscle activation reveal motor unit recruitment
    • Holtermann A., Roeleveld K., and Karlsson J.S. Inhomogeneities in muscle activation reveal motor unit recruitment. J Electromyogr Kinesiol 15 (2005) 131-137
    • (2005) J Electromyogr Kinesiol , vol.15 , pp. 131-137
    • Holtermann, A.1    Roeleveld, K.2    Karlsson, J.S.3
  • 77
    • 23744435454 scopus 로고    scopus 로고
    • Changes in agonist EMG activation level during MVC cannot explain early strength improvement
    • Holtermann A., Roeleveld K., Vereijken B., and Ettema G. Changes in agonist EMG activation level during MVC cannot explain early strength improvement. Eur J Appl Physiol 94 (2005) 593-601
    • (2005) Eur J Appl Physiol , vol.94 , pp. 593-601
    • Holtermann, A.1    Roeleveld, K.2    Vereijken, B.3    Ettema, G.4
  • 78
    • 0041922403 scopus 로고    scopus 로고
    • Changes in muscle fiber conduction velocity indicate recruitment of distinct motor unit populations
    • Houtman C.J., Stegeman D.F., Van Dijk J.P., and Zwarts M.J. Changes in muscle fiber conduction velocity indicate recruitment of distinct motor unit populations. J Appl Physiol 95 (2003) 1045-1054
    • (2003) J Appl Physiol , vol.95 , pp. 1045-1054
    • Houtman, C.J.1    Stegeman, D.F.2    Van Dijk, J.P.3    Zwarts, M.J.4
  • 79
    • 0030766828 scopus 로고    scopus 로고
    • Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases
    • Huppertz H.J., sselhorst-Klug C., Silny J., Rau G., and Heimann G. Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases. Muscle Nerve 20 (1997) 1360-1370
    • (1997) Muscle Nerve , vol.20 , pp. 1360-1370
    • Huppertz, H.J.1    sselhorst-Klug, C.2    Silny, J.3    Rau, G.4    Heimann, G.5
  • 80
    • 0025502445 scopus 로고
    • Noninvasive estimation of the location of the end plate in the human masseter muscle using surface electromyograms with an electrode array
    • Iwasaki S., Tokunaga T., Baba S., Tanaka M., and Kawazoe T. Noninvasive estimation of the location of the end plate in the human masseter muscle using surface electromyograms with an electrode array. J Osaka Dent Univ 24 (1990) 135-140
    • (1990) J Osaka Dent Univ , vol.24 , pp. 135-140
    • Iwasaki, S.1    Tokunaga, T.2    Baba, S.3    Tanaka, M.4    Kawazoe, T.5
  • 81
    • 0030125328 scopus 로고    scopus 로고
    • Compensation for the distortion of bipolar surface EMG signals caused by innervation zone movement
    • Kaneko H., Kiryu T., and Saitoh Y. Compensation for the distortion of bipolar surface EMG signals caused by innervation zone movement. IEICE Trans Informat Systems E79D (1996) 373-381
    • (1996) IEICE Trans Informat Systems , vol.E79D , pp. 373-381
    • Kaneko, H.1    Kiryu, T.2    Saitoh, Y.3
  • 82
    • 0031213564 scopus 로고    scopus 로고
    • Multivariate analysis of muscular fatigue during bicycle ergometer exercise
    • Kiryu T., Takahashi K., and Ogawa K. Multivariate analysis of muscular fatigue during bicycle ergometer exercise. IEEE Trans Biomed Eng 44 (1997) 665-672
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 665-672
    • Kiryu, T.1    Takahashi, K.2    Ogawa, K.3
  • 83
    • 0343628048 scopus 로고    scopus 로고
    • Magnetic stimulation-induced modulations of motor unit firings extracted from multi-channel surface EMG
    • Kleine B.U., Blok J.H., Oostenveld R., Praamstra P., and Stegeman D.F. Magnetic stimulation-induced modulations of motor unit firings extracted from multi-channel surface EMG. Muscle Nerve 23 (2000) 1005-1015
    • (2000) Muscle Nerve , vol.23 , pp. 1005-1015
    • Kleine, B.U.1    Blok, J.H.2    Oostenveld, R.3    Praamstra, P.4    Stegeman, D.F.5
  • 84
    • 0034175830 scopus 로고    scopus 로고
    • Surface EMG mapping of the human trapezius muscle: the topography of monopolar and bipolar surface EMG amplitude and spectrum parameters at varied forces and in fatigue
    • Kleine B.U., Schumann N.P., Stegeman D.F., and Scholle H.C. Surface EMG mapping of the human trapezius muscle: the topography of monopolar and bipolar surface EMG amplitude and spectrum parameters at varied forces and in fatigue. Clin Neurophysiol 111 (2000) 686-693
    • (2000) Clin Neurophysiol , vol.111 , pp. 686-693
    • Kleine, B.U.1    Schumann, N.P.2    Stegeman, D.F.3    Scholle, H.C.4
  • 85
    • 0034997280 scopus 로고    scopus 로고
    • Impaired motor cortical inhibition in Parkinson's disease: motor unit responses to transcranial magnetic stimulation
    • Kleine B.U., Praamstra P., Stegeman D.F., and Zwarts M.J. Impaired motor cortical inhibition in Parkinson's disease: motor unit responses to transcranial magnetic stimulation. Exp Brain Res 138 (2001) 477-483
    • (2001) Exp Brain Res , vol.138 , pp. 477-483
    • Kleine, B.U.1    Praamstra, P.2    Stegeman, D.F.3    Zwarts, M.J.4
  • 86
    • 34547525320 scopus 로고    scopus 로고
    • Kleine BU, Van Dijk JP, Lapatki BG, Zwarts MJ, Stegeman DF (2006) Using two-dimensional spatial information in decomposition of surface EMG signals. J Electromyogr Kinesiol [in press]. doi:10.1016/j.jelekin.2006.05.003.
  • 87
    • 0032766753 scopus 로고    scopus 로고
    • Time-frequency methods applied to muscle fatigue assessment during dynamic contractions
    • Knaflitz M., and Bonato P. Time-frequency methods applied to muscle fatigue assessment during dynamic contractions. J Electromyogr Kinesiol 9 (1999) 337-350
    • (1999) J Electromyogr Kinesiol , vol.9 , pp. 337-350
    • Knaflitz, M.1    Bonato, P.2
  • 88
    • 0027155931 scopus 로고
    • Evaluation of methods to minimize cross-talk in surface electromyography
    • Koh T.J., and Grabiner M.D. Evaluation of methods to minimize cross-talk in surface electromyography. J Biomech 26 (1993) 151-157
    • (1993) J Biomech , vol.26 , pp. 151-157
    • Koh, T.J.1    Grabiner, M.D.2
  • 89
    • 22244469005 scopus 로고    scopus 로고
    • Relationship between the direction of mandibular growth and masseter muscle conduction velocity
    • Konno M., Sato K., Mito T., and Mitani H. Relationship between the direction of mandibular growth and masseter muscle conduction velocity. Am J Orthod Dentofacial Orthop 128 (2005) 35-43
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 35-43
    • Konno, M.1    Sato, K.2    Mito, T.3    Mitani, H.4
  • 90
    • 84995006566 scopus 로고
    • The clinical use of multichannel surface electromyography
    • Kumagai K., and Yamada M. The clinical use of multichannel surface electromyography. Acta Paediatr Jpn 33 (1991) 228-237
    • (1991) Acta Paediatr Jpn , vol.33 , pp. 228-237
    • Kumagai, K.1    Yamada, M.2
  • 91
    • 9644283002 scopus 로고    scopus 로고
    • Reinnervation of motor units in intrinsic muscles of a transplanted hand
    • Lanzetta M., Pozzo M., Bottin A., Merletti R., and Farina D. Reinnervation of motor units in intrinsic muscles of a transplanted hand. Neurosci Lett 373 (2005) 138-143
    • (2005) Neurosci Lett , vol.373 , pp. 138-143
    • Lanzetta, M.1    Pozzo, M.2    Bottin, A.3    Merletti, R.4    Farina, D.5
  • 93
    • 33644790251 scopus 로고    scopus 로고
    • Topographical characteristics of motor units of the lower facial musculature revealed by means of high-density surface EMG
    • Lapatki B.G., Oostenveld R., Van Dijk J.P., Jonas I.E., Zwarts M.J., and Stegeman D.F. Topographical characteristics of motor units of the lower facial musculature revealed by means of high-density surface EMG. J Neurophysiol 95 (2006) 342-354
    • (2006) J Neurophysiol , vol.95 , pp. 342-354
    • Lapatki, B.G.1    Oostenveld, R.2    Van Dijk, J.P.3    Jonas, I.E.4    Zwarts, M.J.5    Stegeman, D.F.6
  • 94
    • 0025687780 scopus 로고
    • Muscle fatigue in mcardles disease - muscle-fiber conduction-velocity and surface EMG frequency-spectrum during ischemic exercise
    • Linssen W.H.J.P., Jacobs M., Stegeman D.F., Joosten E.M.G., and Moleman J. Muscle fatigue in mcardles disease - muscle-fiber conduction-velocity and surface EMG frequency-spectrum during ischemic exercise. Brain 113 (1990) 1779-1793
    • (1990) Brain , vol.113 , pp. 1779-1793
    • Linssen, W.H.J.P.1    Jacobs, M.2    Stegeman, D.F.3    Joosten, E.M.G.4    Moleman, J.5
  • 95
    • 0025826437 scopus 로고
    • Fatigue in type I fiber predominance: a muscle force and surface EMG study on the relative role of type I and type II muscle fibers
    • Linssen W.H., Stegeman D.F., Joosten E.M., Binkhorst R.A., Merks M.J., ter Laak H.J., et al. Fatigue in type I fiber predominance: a muscle force and surface EMG study on the relative role of type I and type II muscle fibers. Muscle Nerve 14 (1991) 829-837
    • (1991) Muscle Nerve , vol.14 , pp. 829-837
    • Linssen, W.H.1    Stegeman, D.F.2    Joosten, E.M.3    Binkhorst, R.A.4    Merks, M.J.5    ter Laak, H.J.6
  • 96
    • 0026077926 scopus 로고
    • Force and fatigue in human type I muscle fibres. A surface EMG study in patients with congenital myopathy and type I fibre predominance
    • Linssen W.H., Stegeman D.F., Joosten E.M., Merks H.J., ter Laak H.J., Binkhorst R.A., et al. Force and fatigue in human type I muscle fibres. A surface EMG study in patients with congenital myopathy and type I fibre predominance. Brain 114 Pt 5 (1991) 2123-2132
    • (1991) Brain , vol.114 , Issue.PART 5 , pp. 2123-2132
    • Linssen, W.H.1    Stegeman, D.F.2    Joosten, E.M.3    Merks, H.J.4    ter Laak, H.J.5    Binkhorst, R.A.6
  • 98
    • 12244271476 scopus 로고    scopus 로고
    • Prediction of endurance capacity of quadriceps muscles in humans using surface electromyogram spectrum analysis during submaximal voluntary isometric contractions
    • Maisetti O., Guevel A., Legros P., and Hogrel J.Y. Prediction of endurance capacity of quadriceps muscles in humans using surface electromyogram spectrum analysis during submaximal voluntary isometric contractions. Eur J Appl Physiol 87 (2002) 509-519
    • (2002) Eur J Appl Physiol , vol.87 , pp. 509-519
    • Maisetti, O.1    Guevel, A.2    Legros, P.3    Hogrel, J.Y.4
  • 99
    • 0002542782 scopus 로고
    • Recruitment threshold and muscle-fiber conduction-velocity of single motor units
    • Masuda T., and DeLuca C.J. Recruitment threshold and muscle-fiber conduction-velocity of single motor units. J Electromyogr Kinesiol 1 (1991) 116-123
    • (1991) J Electromyogr Kinesiol , vol.1 , pp. 116-123
    • Masuda, T.1    DeLuca, C.J.2
  • 100
    • 0022616974 scopus 로고
    • The propagation of single motor unit action potentials detected by a surface electrode array
    • Masuda T., and Sadoyama T. The propagation of single motor unit action potentials detected by a surface electrode array. Electroencephalogr Clin Neurophysiol 63 (1986) 590-598
    • (1986) Electroencephalogr Clin Neurophysiol , vol.63 , pp. 590-598
    • Masuda, T.1    Sadoyama, T.2
  • 101
    • 0023202908 scopus 로고
    • Skeletal muscles from which the propagation of motor unit action potentials is detectable with a surface electrode array
    • Masuda T., and Sadoyama T. Skeletal muscles from which the propagation of motor unit action potentials is detectable with a surface electrode array. Electroencephalogr Clin Neurophysiol 67 (1987) 421-427
    • (1987) Electroencephalogr Clin Neurophysiol , vol.67 , pp. 421-427
    • Masuda, T.1    Sadoyama, T.2
  • 102
    • 0024915552 scopus 로고
    • Processing of myoelectric signals for estimating the location of innervation zones in the skeletal muscles
    • Masuda T., and Sadoyama T. Processing of myoelectric signals for estimating the location of innervation zones in the skeletal muscles. Front Med Biol Eng 1 (1989) 299-314
    • (1989) Front Med Biol Eng , vol.1 , pp. 299-314
    • Masuda, T.1    Sadoyama, T.2
  • 103
    • 0020972793 scopus 로고
    • The distribution of myoneural junctions in the biceps brachii investigated by surface electromyography
    • Masuda T., Miyano H., and Sadoyama T. The distribution of myoneural junctions in the biceps brachii investigated by surface electromyography. Electroencephalogr Clin Neurophysiol 56 (1983) 597-603
    • (1983) Electroencephalogr Clin Neurophysiol , vol.56 , pp. 597-603
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 104
    • 0020569691 scopus 로고
    • The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays
    • Masuda T., Miyano H., and Sadoyama T. The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays. Electroencephalogr Clin Neurophysiol 55 (1983) 594-600
    • (1983) Electroencephalogr Clin Neurophysiol , vol.55 , pp. 594-600
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 105
    • 0021828128 scopus 로고
    • A surface electrode array for detecting action potential trains of single motor units
    • Masuda T., Miyano H., and Sadoyama T. A surface electrode array for detecting action potential trains of single motor units. Electroencephalogr Clin Neurophysiol 60 (1985) 435-443
    • (1985) Electroencephalogr Clin Neurophysiol , vol.60 , pp. 435-443
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 106
    • 0035133168 scopus 로고    scopus 로고
    • Influence of contraction force and speed on muscle fiber conduction velocity during dynamic voluntary exercise
    • Masuda T., Kizuka T., Zhe J.Y., Yamada H., Saitou K., Sadoyama T., et al. Influence of contraction force and speed on muscle fiber conduction velocity during dynamic voluntary exercise. J Electromyogr Kinesiol 11 (2001) 85-94
    • (2001) J Electromyogr Kinesiol , vol.11 , pp. 85-94
    • Masuda, T.1    Kizuka, T.2    Zhe, J.Y.3    Yamada, H.4    Saitou, K.5    Sadoyama, T.6
  • 107
    • 4444250291 scopus 로고    scopus 로고
    • Surface electromyogram signal modelling
    • McGill K.C. Surface electromyogram signal modelling. Med Biol Eng Comput 42 (2004) 446-454
    • (2004) Med Biol Eng Comput , vol.42 , pp. 446-454
    • McGill, K.C.1
  • 109
    • 0032974147 scopus 로고    scopus 로고
    • Modeling of surface myoelectric signals - Part II: Model-based signal interpretation
    • Merletti R., Roy S.H., Kupa E., Roatta S., and Granata A. Modeling of surface myoelectric signals - Part II: Model-based signal interpretation. IEEE Trans Biomed Eng 46 (1999) 821-829
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 821-829
    • Merletti, R.1    Roy, S.H.2    Kupa, E.3    Roatta, S.4    Granata, A.5
  • 110
    • 0037290798 scopus 로고    scopus 로고
    • The linear electrode array: a useful tool with many applications
    • Merletti R., Farina D., and Gazzoni M. The linear electrode array: a useful tool with many applications. J Electromyogr Kinesiol 13 (2003) 37-47
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 37-47
    • Merletti, R.1    Farina, D.2    Gazzoni, M.3
  • 111
    • 2642536743 scopus 로고    scopus 로고
    • Multichannel surface EMG for the non-invasive assessment of the anal sphincter muscle
    • Merletti R., Bottin A., Cescon C., Farina D., Gazzoni M., Martina S., et al. Multichannel surface EMG for the non-invasive assessment of the anal sphincter muscle. Digestion 69 (2004) 112-122
    • (2004) Digestion , vol.69 , pp. 112-122
    • Merletti, R.1    Bottin, A.2    Cescon, C.3    Farina, D.4    Gazzoni, M.5    Martina, S.6
  • 112
    • 0037339348 scopus 로고    scopus 로고
    • A fast and reliable technique for muscle activity detection from surface EMG signals
    • Merlo A., Farina D., and Merletti R. A fast and reliable technique for muscle activity detection from surface EMG signals. IEEE Trans Biomed Eng 50 (2003) 316-323
    • (2003) IEEE Trans Biomed Eng , vol.50 , pp. 316-323
    • Merlo, A.1    Farina, D.2    Merletti, R.3
  • 113
    • 4143116593 scopus 로고    scopus 로고
    • Simulation of surface EMG signals generated by muscle tissues with inhomogeneity due to fiber pinnation
    • Mesin L., and Farina D. Simulation of surface EMG signals generated by muscle tissues with inhomogeneity due to fiber pinnation. IEEE Trans Biomed Eng 51 (2004) 1521-1529
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 1521-1529
    • Mesin, L.1    Farina, D.2
  • 114
    • 28844493949 scopus 로고    scopus 로고
    • A model for surface EMG generation in volume conductors with spherical inhomogeneities
    • Mesin L., and Farina D. A model for surface EMG generation in volume conductors with spherical inhomogeneities. IEEE Trans Biomed Eng 52 (2005) 1984-1993
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1984-1993
    • Mesin, L.1    Farina, D.2
  • 115
    • 33646351774 scopus 로고    scopus 로고
    • An analytical model for surface EMG generation in volume conductors with smooth conductivity variations
    • Mesin L., and Farina D. An analytical model for surface EMG generation in volume conductors with smooth conductivity variations. IEEE Trans Biomed Eng 53 (2006) 773-779
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 773-779
    • Mesin, L.1    Farina, D.2
  • 116
    • 0018403061 scopus 로고
    • Theoretical analysis of surface EMG in voluntary isometric contraction
    • Miyano H., and Sadoyama T. Theoretical analysis of surface EMG in voluntary isometric contraction. Eur J Appl Physiol Occup Physiol 40 (1979) 155-164
    • (1979) Eur J Appl Physiol Occup Physiol , vol.40 , pp. 155-164
    • Miyano, H.1    Sadoyama, T.2
  • 117
    • 0031424999 scopus 로고    scopus 로고
    • Multivariate analysis of multichannel surface myoelectric signals to determine muscular fatigue
    • Nakamura Y., Kiryu T., and Saitoh Y. Multivariate analysis of multichannel surface myoelectric signals to determine muscular fatigue. Methods Inf Med 36 (1997) 302-305
    • (1997) Methods Inf Med , vol.36 , pp. 302-305
    • Nakamura, Y.1    Kiryu, T.2    Saitoh, Y.3
  • 118
    • 2542447234 scopus 로고    scopus 로고
    • The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part I-measuring techniques
    • Nakamura H., Yoshida M., Kotani M., Akazawa K., and Moritani T. The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part I-measuring techniques. J Electromyogr Kinesiol 14 (2004) 423-432
    • (2004) J Electromyogr Kinesiol , vol.14 , pp. 423-432
    • Nakamura, H.1    Yoshida, M.2    Kotani, M.3    Akazawa, K.4    Moritani, T.5
  • 119
    • 2542478968 scopus 로고    scopus 로고
    • The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part II-modelling interpretation
    • Nakamura H., Yoshida M., Kotani M., Akazawa K., and Moritani T. The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part II-modelling interpretation. J Electromyogr Kinesiol 14 (2004) 433-441
    • (2004) J Electromyogr Kinesiol , vol.14 , pp. 433-441
    • Nakamura, H.1    Yoshida, M.2    Kotani, M.3    Akazawa, K.4    Moritani, T.5
  • 121
    • 0025192333 scopus 로고
    • Muscle fiber conduction velocity and contractile properties estimated from surface electrode arrays
    • Nishizono H., Fujimoto T., Ohtake H., and Miyashita M. Muscle fiber conduction velocity and contractile properties estimated from surface electrode arrays. Electroencephalogr Clin Neurophysiol 75 (1990) 75-81
    • (1990) Electroencephalogr Clin Neurophysiol , vol.75 , pp. 75-81
    • Nishizono, H.1    Fujimoto, T.2    Ohtake, H.3    Miyashita, M.4
  • 123
    • 0032575586 scopus 로고    scopus 로고
    • Relationship between nerve and muscle fiber conduction velocities of the same motor unit in man
    • Okajima Y., Toikawa H., Hanayama K., Ohtsuka T., Kimura A., and Chino N. Relationship between nerve and muscle fiber conduction velocities of the same motor unit in man. Neurosci Lett 253 (1998) 65-67
    • (1998) Neurosci Lett , vol.253 , pp. 65-67
    • Okajima, Y.1    Toikawa, H.2    Hanayama, K.3    Ohtsuka, T.4    Kimura, A.5    Chino, N.6
  • 124
    • 20444426274 scopus 로고    scopus 로고
    • Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations
    • Ollivier K., Portero P., Maisetti O., and Hogrel J.Y. Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations. J Electromyogr Kinesiol 15 (2005) 466-473
    • (2005) J Electromyogr Kinesiol , vol.15 , pp. 466-473
    • Ollivier, K.1    Portero, P.2    Maisetti, O.3    Hogrel, J.Y.4
  • 125
    • 10244261701 scopus 로고    scopus 로고
    • Adaptive spatial filtering of multichannel surface electromyogram signals
    • Ostlund N., Yu J., Roeleveld K., and Karlsson J.S. Adaptive spatial filtering of multichannel surface electromyogram signals. Med Biol Eng Comput 42 (2004) 825-831
    • (2004) Med Biol Eng Comput , vol.42 , pp. 825-831
    • Ostlund, N.1    Yu, J.2    Roeleveld, K.3    Karlsson, J.S.4
  • 126
    • 4444250956 scopus 로고    scopus 로고
    • Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays
    • Pozzo M., Bottin A., Ferrabone R., and Merletti R. Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays. Med Biol Eng Comput 42 (2004) 455-466
    • (2004) Med Biol Eng Comput , vol.42 , pp. 455-466
    • Pozzo, M.1    Bottin, A.2    Ferrabone, R.3    Merletti, R.4
  • 127
    • 0029361138 scopus 로고
    • A high-resolution large array (HRLA) surface EMG system
    • Prutchi D. A high-resolution large array (HRLA) surface EMG system. Med Eng Phys 17 (1995) 442-454
    • (1995) Med Eng Phys , vol.17 , pp. 442-454
    • Prutchi, D.1
  • 128
    • 0033865959 scopus 로고    scopus 로고
    • Clinical utility of surface EMG: report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology
    • Pullman S.L., Goodin D.S., Marquinez A.I., Tabbal S., and Rubin M. Clinical utility of surface EMG: report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology. Neurology 55 (2000) 171-177
    • (2000) Neurology , vol.55 , pp. 171-177
    • Pullman, S.L.1    Goodin, D.S.2    Marquinez, A.I.3    Tabbal, S.4    Rubin, M.5
  • 129
    • 0027183181 scopus 로고
    • Clinical-application of a noninvasive multielectrode array EMG for the recording of single motor unit-activity
    • Ramaekers V.T., DisselhorstKlug C., Schneider J., Silny J., Forst J., Forst R., et al. Clinical-application of a noninvasive multielectrode array EMG for the recording of single motor unit-activity. Neuropediatrics 24 (1993) 134-138
    • (1993) Neuropediatrics , vol.24 , pp. 134-138
    • Ramaekers, V.T.1    DisselhorstKlug, C.2    Schneider, J.3    Silny, J.4    Forst, J.5    Forst, R.6
  • 130
    • 0030867101 scopus 로고    scopus 로고
    • Principles of high-spatial-resolution surface EMG (HSR-EMG): Single motor unit detection and application in the diagnosis of neuromuscular disorders
    • Rau G., and DisselhorstKlug C. Principles of high-spatial-resolution surface EMG (HSR-EMG): Single motor unit detection and application in the diagnosis of neuromuscular disorders. J Electromyogr Kinesiol 7 (1997) 233-239
    • (1997) J Electromyogr Kinesiol , vol.7 , pp. 233-239
    • Rau, G.1    DisselhorstKlug, C.2
  • 131
    • 0031148596 scopus 로고    scopus 로고
    • Noninvasive approach to motor unit characterization: muscle structure, membrane dynamics and neuronal control
    • Rau G., Disselhorst-Klug C., and Silny J. Noninvasive approach to motor unit characterization: muscle structure, membrane dynamics and neuronal control. J Biomech 30 (1997) 441-446
    • (1997) J Biomech , vol.30 , pp. 441-446
    • Rau, G.1    Disselhorst-Klug, C.2    Silny, J.3
  • 132
    • 4043145008 scopus 로고    scopus 로고
    • From cell to movement: to what answers does EMG really contribute?
    • Rau G., Schulte E., and Disselhorst-Klug C. From cell to movement: to what answers does EMG really contribute?. J Electromyogr Kinesiol 14 (2004) 611-617
    • (2004) J Electromyogr Kinesiol , vol.14 , pp. 611-617
    • Rau, G.1    Schulte, E.2    Disselhorst-Klug, C.3
  • 133
    • 84939033845 scopus 로고
    • Spatial-filtering of noninvasive multielectrode Emg .1. Introduction to measuring technique and applications
    • Reucher H., Rau G., and Silny J. Spatial-filtering of noninvasive multielectrode Emg .1. Introduction to measuring technique and applications. IEEE Trans Biomed Eng 34 (1987) 98-105
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 98-105
    • Reucher, H.1    Rau, G.2    Silny, J.3
  • 134
    • 0023289453 scopus 로고
    • Spatial-filtering of noninvasive multielectrode Emg .2. Filter performance in theory and modeling
    • Reucher H., Silny J., and Rau G. Spatial-filtering of noninvasive multielectrode Emg .2. Filter performance in theory and modeling. IEEE Trans Biomed Eng 34 (1987) 106-113
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 106-113
    • Reucher, H.1    Silny, J.2    Rau, G.3
  • 135
    • 0036262989 scopus 로고    scopus 로고
    • What do we learn from motor unit action potentials in surface electromyography?
    • Roeleveld K., and Stegeman D.F. What do we learn from motor unit action potentials in surface electromyography?. Muscle Nerve Suppl. 11 (2002) S92-S97
    • (2002) Muscle Nerve , Issue.SUPPL. 11
    • Roeleveld, K.1    Stegeman, D.F.2
  • 137
    • 0031745140 scopus 로고    scopus 로고
    • Motor unit size estimation of enlarged motor units with surface electromyography
    • Roeleveld K., Sandberg A., Stalberg E.V., and Stegeman D.F. Motor unit size estimation of enlarged motor units with surface electromyography. Muscle Nerve 21 (1998) 878-886
    • (1998) Muscle Nerve , vol.21 , pp. 878-886
    • Roeleveld, K.1    Sandberg, A.2    Stalberg, E.V.3    Stegeman, D.F.4
  • 138
    • 0034129215 scopus 로고    scopus 로고
    • Possible mechanisms of muscle cramp from temporal and spatial surface EMG characteristics
    • Roeleveld K., Van Engelen B.G., and Stegeman D.F. Possible mechanisms of muscle cramp from temporal and spatial surface EMG characteristics. J Appl Physiol 88 (2000) 1698-1706
    • (2000) J Appl Physiol , vol.88 , pp. 1698-1706
    • Roeleveld, K.1    Van Engelen, B.G.2    Stegeman, D.F.3
  • 139
    • 0022093412 scopus 로고
    • Optimal conditions for the measurement of muscle fibre conduction velocity using surface electrode arrays
    • Sadoyama T., Masuda T., and Miyano H. Optimal conditions for the measurement of muscle fibre conduction velocity using surface electrode arrays. Med Biol Eng Comput 23 (1985) 339-342
    • (1985) Med Biol Eng Comput , vol.23 , pp. 339-342
    • Sadoyama, T.1    Masuda, T.2    Miyano, H.3
  • 141
    • 0037851968 scopus 로고    scopus 로고
    • Innervation zones of the upper and lower limb muscles estimated by using multichannel surface EMG
    • Saitou K., Masuda T., Michikami D., Kojima R., and Okada M. Innervation zones of the upper and lower limb muscles estimated by using multichannel surface EMG. J Hum Ergol (Tokyo) 29 (2000) 35-52
    • (2000) J Hum Ergol (Tokyo) , vol.29 , pp. 35-52
    • Saitou, K.1    Masuda, T.2    Michikami, D.3    Kojima, R.4    Okada, M.5
  • 142
    • 0037391340 scopus 로고    scopus 로고
    • Amplitude and spectral characteristics of biceps Brachii sEMG depend upon speed of isometric force generation
    • Sbriccoli P., Bazzucchi I., Rosponi A., Bernardi M., De V.G., and Felici F. Amplitude and spectral characteristics of biceps Brachii sEMG depend upon speed of isometric force generation. J Electromyogr Kinesiol 13 (2003) 139-147
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 139-147
    • Sbriccoli, P.1    Bazzucchi, I.2    Rosponi, A.3    Bernardi, M.4    De, V.G.5    Felici, F.6
  • 144
    • 0024333818 scopus 로고
    • A noninvasive EMG technique for investigating the excitation propagation in single motor units
    • Schneider J., Rau G., and Silny J. A noninvasive EMG technique for investigating the excitation propagation in single motor units. Electromyogr Clin Neurophysiol 29 (1989) 273-280
    • (1989) Electromyogr Clin Neurophysiol , vol.29 , pp. 273-280
    • Schneider, J.1    Rau, G.2    Silny, J.3
  • 145
    • 0026228535 scopus 로고
    • Influence of tissue inhomogeneities on noninvasive muscle-fiber conduction-velocity measurements - investigated by physical and numerical modeling
    • Schneider J., Silny J., and Rau G. Influence of tissue inhomogeneities on noninvasive muscle-fiber conduction-velocity measurements - investigated by physical and numerical modeling. IEEE Trans Biomed Eng 38 (1991) 851-860
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 851-860
    • Schneider, J.1    Silny, J.2    Rau, G.3
  • 146
  • 147
    • 4444233179 scopus 로고    scopus 로고
    • Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals
    • Schulte E., Farina D., Merletti R., Rau G., and Disselhorst-Klug C. Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals. Med Biol Eng Comput 42 (2004) 477-486
    • (2004) Med Biol Eng Comput , vol.42 , pp. 477-486
    • Schulte, E.1    Farina, D.2    Merletti, R.3    Rau, G.4    Disselhorst-Klug, C.5
  • 148
    • 14844331057 scopus 로고    scopus 로고
    • Estimation of the muscle fibre semi-length under varying joint positions on the basis of non-invasively extracted motor unit action potentials
    • Schulte E., Dimitrova N.A., Dimitrov G.V., Rau G., and Disselhorst-Klug C. Estimation of the muscle fibre semi-length under varying joint positions on the basis of non-invasively extracted motor unit action potentials. J Electromyogr Kinesiol 15 (2005) 290-299
    • (2005) J Electromyogr Kinesiol , vol.15 , pp. 290-299
    • Schulte, E.1    Dimitrova, N.A.2    Dimitrov, G.V.3    Rau, G.4    Disselhorst-Klug, C.5
  • 149
    • 31144467041 scopus 로고    scopus 로고
    • Comparison of the electromyographic activity in the upper trapezius and biceps brachii muscle in subjects with muscular disorders: a pilot study
    • Schulte E., Kallenberg L.A.C., Christensen H., Disselhorst-Klug C., Hermens H.J., Rau G., et al. Comparison of the electromyographic activity in the upper trapezius and biceps brachii muscle in subjects with muscular disorders: a pilot study. Eur J Appl Physiol 96 (2006) 185-193
    • (2006) Eur J Appl Physiol , vol.96 , pp. 185-193
    • Schulte, E.1    Kallenberg, L.A.C.2    Christensen, H.3    Disselhorst-Klug, C.4    Hermens, H.J.5    Rau, G.6
  • 150
    • 31144456402 scopus 로고    scopus 로고
    • Upper trapezius muscle conduction velocity during fatigue in subjects with and without work-related muscular disorders: a non-invasive high spatial resolution approach
    • Schulte E., Miltner O., Junker E., Rau G., and Disselhorst-Klug C. Upper trapezius muscle conduction velocity during fatigue in subjects with and without work-related muscular disorders: a non-invasive high spatial resolution approach. Eur J Appl Physiol 96 (2006) 194-202
    • (2006) Eur J Appl Physiol , vol.96 , pp. 194-202
    • Schulte, E.1    Miltner, O.2    Junker, E.3    Rau, G.4    Disselhorst-Klug, C.5
  • 151
    • 11844264542 scopus 로고    scopus 로고
    • Towards optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG study
    • Staudenmann D., Kingma I., Stegeman D.F., and van Dieen J.H. Towards optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG study. J Electromyogr Kinesiol 15 (2005) 1-11
    • (2005) J Electromyogr Kinesiol , vol.15 , pp. 1-11
    • Staudenmann, D.1    Kingma, I.2    Stegeman, D.F.3    van Dieen, J.H.4
  • 152
    • 33645317089 scopus 로고    scopus 로고
    • Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis
    • Staudenmann D., Kingma I., Daffertshofer A., Stegeman D.F., and van Dieen J.H. Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis. IEEE Trans Biomed Eng 53 (2006) 712-719
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 712-719
    • Staudenmann, D.1    Kingma, I.2    Daffertshofer, A.3    Stegeman, D.F.4    van Dieen, J.H.5
  • 155
    • 0033934435 scopus 로고    scopus 로고
    • Analysis of motor unit firing patterns in patients with central or peripheral lesions using singular-value decomposition
    • Sun T.Y., Chen J.J., and Lin T.S. Analysis of motor unit firing patterns in patients with central or peripheral lesions using singular-value decomposition. Muscle Nerve 23 (2000) 1057-1068
    • (2000) Muscle Nerve , vol.23 , pp. 1057-1068
    • Sun, T.Y.1    Chen, J.J.2    Lin, T.S.3
  • 157
    • 0024619252 scopus 로고
    • A practical electrode-array myoprocessor for surface electromyography
    • Thusneyapan S., and Zahalak G.I. A practical electrode-array myoprocessor for surface electromyography. IEEE Trans Biomed Eng 36 (1989) 295-299
    • (1989) IEEE Trans Biomed Eng , vol.36 , pp. 295-299
    • Thusneyapan, S.1    Zahalak, G.I.2
  • 158
    • 0026285359 scopus 로고
    • Measurement of muscle fiber conduction velocity in the human masseter muscle using the surface EMG cross-correlation technique
    • Tokunaga T., Kimura K., Tanaka M., and Kawazoe T. Measurement of muscle fiber conduction velocity in the human masseter muscle using the surface EMG cross-correlation technique. Front Med Biol Eng 3 (1991) 215-219
    • (1991) Front Med Biol Eng , vol.3 , pp. 215-219
    • Tokunaga, T.1    Kimura, K.2    Tanaka, M.3    Kawazoe, T.4
  • 159
    • 0032060084 scopus 로고    scopus 로고
    • Two-dimensional configuration of the myoneural junctions of human masticatory muscle detected with matrix electrode
    • Tokunaga T., Baba S., Tanaka M., Kashiwagi K., Kimura K., and Kawazoe T. Two-dimensional configuration of the myoneural junctions of human masticatory muscle detected with matrix electrode. J Oral Rehabil 25 (1998) 329-334
    • (1998) J Oral Rehabil , vol.25 , pp. 329-334
    • Tokunaga, T.1    Baba, S.2    Tanaka, M.3    Kashiwagi, K.4    Kimura, K.5    Kawazoe, T.6
  • 161
    • 0027435002 scopus 로고
    • Muscle fiber conduction velocity in amyotrophic lateral sclerosis and traumatic lesions of the plexus brachialis
    • van der Hoeven J.H., Zwarts M.J., and van Weerden T.W. Muscle fiber conduction velocity in amyotrophic lateral sclerosis and traumatic lesions of the plexus brachialis. Electroencephalogr Clin Neurophysiol 89 (1993) 304-310
    • (1993) Electroencephalogr Clin Neurophysiol , vol.89 , pp. 304-310
    • van der Hoeven, J.H.1    Zwarts, M.J.2    van Weerden, T.W.3
  • 162
    • 0028146197 scopus 로고
    • Muscle fiber conduction velocity in the diagnosis of familial hypokalemic periodic paralysis-invasive versus surface determination
    • van der Hoeven J.H., Links T.P., Zwarts M.J., and van Weerden T.W. Muscle fiber conduction velocity in the diagnosis of familial hypokalemic periodic paralysis-invasive versus surface determination. Muscle Nerve 17 (1994) 898-905
    • (1994) Muscle Nerve , vol.17 , pp. 898-905
    • van der Hoeven, J.H.1    Links, T.P.2    Zwarts, M.J.3    van Weerden, T.W.4
  • 163
    • 0035078460 scopus 로고    scopus 로고
    • A convenient method to reduce crosstalk in surface EMG. Cobb Award-winning article, 2001
    • van Vugt J.P., and van Dijk J.G. A convenient method to reduce crosstalk in surface EMG. Cobb Award-winning article, 2001. Clin Neurophysiol 112 (2001) 583-592
    • (2001) Clin Neurophysiol , vol.112 , pp. 583-592
    • van Vugt, J.P.1    van Dijk, J.G.2
  • 164
    • 0035139843 scopus 로고    scopus 로고
    • Surface electromyography using electrode arrays: a study of motor neuron disease
    • Wood S.M., Jarratt J.A., Barker A.T., and Brown B.H. Surface electromyography using electrode arrays: a study of motor neuron disease. Muscle Nerve 24 (2001) 223-230
    • (2001) Muscle Nerve , vol.24 , pp. 223-230
    • Wood, S.M.1    Jarratt, J.A.2    Barker, A.T.3    Brown, B.H.4
  • 165
    • 0023182261 scopus 로고
    • The distribution and propagation pattern of motor unit action potentials studied by multi-channel surface EMG
    • Yamada M., Kumagai K., and Uchiyama A. The distribution and propagation pattern of motor unit action potentials studied by multi-channel surface EMG. Electroencephalogr Clin Neurophysiol 67 (1987) 395-401
    • (1987) Electroencephalogr Clin Neurophysiol , vol.67 , pp. 395-401
    • Yamada, M.1    Kumagai, K.2    Uchiyama, A.3
  • 166
    • 0025822275 scopus 로고
    • Muscle fiber conduction velocity studied by the multi-channel surface EMG
    • Yamada M., Kumagai K., and Uchiyama A. Muscle fiber conduction velocity studied by the multi-channel surface EMG. Electromyogr Clin Neurophysiol 31 (1991) 251-256
    • (1991) Electromyogr Clin Neurophysiol , vol.31 , pp. 251-256
    • Yamada, M.1    Kumagai, K.2    Uchiyama, A.3
  • 167
    • 0024310987 scopus 로고
    • Evaluation of the estimation of muscle fiber conduction velocity. Surface versus needle method. Electroencephalogr
    • Zwarts M.J. Evaluation of the estimation of muscle fiber conduction velocity. Surface versus needle method. Electroencephalogr. Clin Neurophysiol 73 (1989) 544-548
    • (1989) Clin Neurophysiol , vol.73 , pp. 544-548
    • Zwarts, M.J.1
  • 168
    • 0038121674 scopus 로고    scopus 로고
    • Multichannel surface EMG: basic aspects and clinical utility
    • Zwarts M.J., and Stegeman D.F. Multichannel surface EMG: basic aspects and clinical utility. Muscle Nerve 28 (2003) 1-17
    • (2003) Muscle Nerve , vol.28 , pp. 1-17
    • Zwarts, M.J.1    Stegeman, D.F.2
  • 169
    • 0024364795 scopus 로고
    • Transient paresis in myotonic syndromes. A surface EMG study
    • Zwarts M.J., and van Weerden T.W. Transient paresis in myotonic syndromes. A surface EMG study. Brain 112 Pt 3 (1989) 665-680
    • (1989) Brain , vol.112 , Issue.PART 3 , pp. 665-680
    • Zwarts, M.J.1    van Weerden, T.W.2
  • 170
    • 0023853840 scopus 로고
    • The muscle fiber conduction velocity and power spectra in familial hypokalemic periodic paralysis
    • Zwarts M.J., van Weerden T.W., Links T.P., Haenen H.T., and Oosterhuis H.J. The muscle fiber conduction velocity and power spectra in familial hypokalemic periodic paralysis. Muscle Nerve 11 (1988) 166-173
    • (1988) Muscle Nerve , vol.11 , pp. 166-173
    • Zwarts, M.J.1    van Weerden, T.W.2    Links, T.P.3    Haenen, H.T.4    Oosterhuis, H.J.5
  • 171
    • 0033817510 scopus 로고    scopus 로고
    • Recent progress in the diagnostic use of surface EMG for neurological diseases
    • Zwarts M.J., Drost G., and Stegeman D.F. Recent progress in the diagnostic use of surface EMG for neurological diseases. J Electromyogr Kinesiol 10 (2000) 287-291
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 287-291
    • Zwarts, M.J.1    Drost, G.2    Stegeman, D.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.