-
1
-
-
0013941871
-
The intraclass correlation coefficient as a measure of reliability
-
J.J. Bartko The intraclass correlation coefficient as a measure of reliability Psychol. Rep. 19 1966 3 11
-
(1966)
Psychol. Rep.
, vol.19
, pp. 3-11
-
-
Bartko, J.J.1
-
3
-
-
0030973129
-
The use of surface electromyography in biomechanics
-
C.J. De Luca The use of surface electromyography in biomechanics J. Appl. Biomech. 13 1997 135 163
-
(1997)
J. Appl. Biomech.
, vol.13
, pp. 135-163
-
-
De Luca, C.J.1
-
4
-
-
0031195287
-
Improvement of spatial resolution in surface EMG: A theoretical and experimental comparison of different spatial filters
-
C. Disselhorst-Klug, J. Silny, and G. Rau Improvement of spatial resolution in surface EMG: a theoretical and experimental comparison of different spatial filters IEEE Trans. Biomed. Eng. 44 1997 567 574
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
, pp. 567-574
-
-
Disselhorst-Klug, C.1
Silny, J.2
Rau, G.3
-
5
-
-
0034533623
-
Non-invasive approach of motor unit recording during muscle contractions in human
-
C. Disselhorst-Klug, J. Bahm, V. Ramaekers, A. Trachterna, and G. Rau Non-invasive approach of motor unit recording during muscle contractions in human Eur. J. Appl. Physiol. 83 2000 144 150
-
(2000)
Eur. J. Appl. Physiol.
, vol.83
, pp. 144-150
-
-
Disselhorst-Klug, C.1
Bahm, J.2
Ramaekers, V.3
Trachterna, A.4
Rau, G.5
-
6
-
-
0027165327
-
Surface electromyogram during voluntary contraction: Processing tools and relation to physiological events
-
J. Duchêne, and F. Goubel Surface electromyogram during voluntary contraction: processing tools and relation to physiological events CRC Crit. Rev. Biomed. Eng. 21 1993 313 397
-
(1993)
CRC Crit. Rev. Biomed. Eng.
, vol.21
, pp. 313-397
-
-
Duchêne, J.1
Goubel, F.2
-
7
-
-
20444370918
-
Sensors and sensor placement procedures used in the european labs
-
H.J. Hermens B. Freriks Roessingh Research and Development b.v. Enschede
-
B. Frericks, C. Disselhorst-Klug, H.J. Hermens, and G. Rau Sensors and sensor placement procedures used in the european labs H.J. Hermens B. Freriks The state of the art on sensors and sensor placement procedures for surface electromyography: a proposal for sensor placement procedures, SENIAM 5 1997 Roessingh Research and Development b.v. Enschede 7 27
-
(1997)
The State of the Art on Sensors and Sensor Placement Procedures for Surface Electromyography: A Proposal for Sensor Placement Procedures, SENIAM 5
, pp. 7-27
-
-
Frericks, B.1
Disselhorst-Klug, C.2
Hermens, H.J.3
Rau, G.4
-
8
-
-
0025081216
-
Comparisons between surface electrodes and intramuscular wire electrodes in isometric and dynamic conditions
-
B. Giroux, and M. Lamontagne Comparisons between surface electrodes and intramuscular wire electrodes in isometric and dynamic conditions Electromyogr. Clin. Neurophysiol. 30 1990 397 405
-
(1990)
Electromyogr. Clin. Neurophysiol.
, vol.30
, pp. 397-405
-
-
Giroux, B.1
Lamontagne, M.2
-
9
-
-
0028042905
-
Recovery of conduction velocity of muscle fiber action potential after strenuous isometric contraction
-
K. Hanoyama Recovery of conduction velocity of muscle fiber action potential after strenuous isometric contraction Jpn. J. Physiol. 44 1994 75 88
-
(1994)
Jpn. J. Physiol.
, vol.44
, pp. 75-88
-
-
Hanoyama, K.1
-
10
-
-
0032191629
-
Variability of some SEMG parameter estimates with electrode location
-
J.Y. Hogrel, J. Duchêne, and J.F. Marini Variability of some SEMG parameter estimates with electrode location J. Electromyogr. Kinesiol. 8 1998 305 315
-
(1998)
J. Electromyogr. Kinesiol.
, vol.8
, pp. 305-315
-
-
Hogrel, J.Y.1
Duchêne, J.2
Marini, J.F.3
-
11
-
-
0002274374
-
A SEMG-based system for clinical applications using Laplacian electrodes
-
H.J. Hermens B. Freriks Roessingh Research and Development b.v. Enschede
-
J.Y. Hogrel, and J. Duchêne A SEMG-based system for clinical applications using Laplacian electrodes H.J. Hermens B. Freriks Future applications of surface electromyography, SENIAM 4 1999 Roessingh Research and Development b.v. Enschede 172 177
-
(1999)
Future Applications of Surface Electromyography, SENIAM 4
, pp. 172-177
-
-
Hogrel, J.Y.1
Duchêne, J.2
-
12
-
-
0030766828
-
Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases
-
H.J. Huppertz, C. Disselhorst-Klug, J. Silny, G. Rau, and G. Heimann Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases Muscle Nerve 20 1997 1360 1370
-
(1997)
Muscle Nerve
, vol.20
, pp. 1360-1370
-
-
Huppertz, H.J.1
Disselhorst-Klug, C.2
Silny, J.3
Rau, G.4
Heimann, G.5
-
13
-
-
20444412238
-
Displacement, deformaand and fracture of wire electrodes for electromyography
-
B. Jonsson, and U.E. Bagga Displacement, deformaand and fracture of wire electrodes for electromyography Electromyography 8 1968 328 347
-
(1968)
Electromyography
, vol.8
, pp. 328-347
-
-
Jonsson, B.1
Bagga, U.E.2
-
15
-
-
0014871810
-
Reproducibility of electromyographic measurements with inserted wire electrodes and surface electrodes
-
P.V. Komi, and E.R. Buskirk Reproducibility of electromyographic measurements with inserted wire electrodes and surface electrodes Electromyography 10 1970 357 367
-
(1970)
Electromyography
, vol.10
, pp. 357-367
-
-
Komi, P.V.1
Buskirk, E.R.2
-
16
-
-
0029925822
-
Spectral analysis during fatigue, Surface and fine wire electrode comparison
-
L.S. Krivickas, S.F. Nadler, M.R. Davies, G.F. Petroski, and J.H. Feinberg Spectral analysis during fatigue, Surface and fine wire electrode comparison Am. J. Phys. Med. Rehabil. 75 1996 15 20
-
(1996)
Am. J. Phys. Med. Rehabil.
, vol.75
, pp. 15-20
-
-
Krivickas, L.S.1
Nadler, S.F.2
Davies, M.R.3
Petroski, G.F.4
Feinberg, J.H.5
-
17
-
-
0025864502
-
Changes in conduction velocity, median frequency, and root mean square-amplitude of the electromyogram during 25% maximal voluntary contraction of the triceps brachii muscle, to limit of endurance
-
C. Krogh-Lund, and K. Jørgensen Changes in conduction velocity, median frequency, and root mean square-amplitude of the electromyogram during 25% maximal voluntary contraction of the triceps brachii muscle, to limit of endurance Eur. J. Appl. Physiol. 63 1991 60 69
-
(1991)
Eur. J. Appl. Physiol.
, vol.63
, pp. 60-69
-
-
Krogh-Lund, C.1
Jørgensen, K.2
-
18
-
-
0344436044
-
Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions
-
B. Larsson, B. Månsson, C. Karlberg, P. Syvertsson, J. Elert, and B. Gerdle Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions J. Electromyogr. Kinesiol. 9 1999 351 357
-
(1999)
J. Electromyogr. Kinesiol.
, vol.9
, pp. 351-357
-
-
Larsson, B.1
Månsson, B.2
Karlberg, C.3
Syvertsson, P.4
Elert, J.5
Gerdle, B.6
-
19
-
-
0029692063
-
Distribution of muscle fiber conduction velocity of m. biceps brachii during voluntary isometric contraction with use of surface array electrodes
-
W. Li, and K. Sakamoto Distribution of muscle fiber conduction velocity of m. biceps brachii during voluntary isometric contraction with use of surface array electrodes Appl. Hum. Sci. 15 1996 41 53
-
(1996)
Appl. Hum. Sci.
, vol.15
, pp. 41-53
-
-
Li, W.1
Sakamoto, K.2
-
22
-
-
0032170315
-
ISEK congress keynote lecture the use of electromyography in applied physiology
-
T. Moritani, and Y. Yoshitake ISEK congress keynote lecture the use of electromyography in applied physiology J. Electromyogr. Kinesiol. 8 1998 363 381
-
(1998)
J. Electromyogr. Kinesiol.
, vol.8
, pp. 363-381
-
-
Moritani, T.1
Yoshitake, Y.2
-
23
-
-
0033025788
-
Repeatability of surface EMG variables during voluntary isometric contraction of the biceps brachii muscle
-
A. Rainoldi, G. Galardi, L. Maderna, G. Comi, L. Lo Conto, and R. Merletti Repeatability of surface EMG variables during voluntary isometric contraction of the biceps brachii muscle J. Electromyogr. Kinesiol. 9 1999 105 119
-
(1999)
J. Electromyogr. Kinesiol.
, vol.9
, pp. 105-119
-
-
Rainoldi, A.1
Galardi, G.2
Maderna, L.3
Comi, G.4
Lo Conto, L.5
Merletti, R.6
-
24
-
-
0030867101
-
Principles of high spatial resolution EMG (HSR-EMG): Single motor unit detection and the application in the diagnosis of neuromuscular disorders
-
G. Rau, and C. Disselhorst-Klug Principles of high spatial resolution EMG (HSR-EMG): single motor unit detection and the application in the diagnosis of neuromuscular disorders J. Electromyogr. Kinesiol. 7 1997 233 239
-
(1997)
J. Electromyogr. Kinesiol.
, vol.7
, pp. 233-239
-
-
Rau, G.1
Disselhorst-Klug, C.2
-
25
-
-
84939033845
-
Spatial filtering of noninvasive multielectrode EMG. I. Introduction to measuring technique technique and applications
-
H. Reucher, G. Rau, and J. Silny Spatial filtering of noninvasive multielectrode EMG. I. Introduction to measuring technique technique and applications IEEE Trans. Biomed. Eng. 34 1987 98 105
-
(1987)
IEEE Trans. Biomed. Eng.
, vol.34
, pp. 98-105
-
-
Reucher, H.1
Rau, G.2
Silny, J.3
-
26
-
-
0023289453
-
Spatial filtering of noninvasive multielectrode EMG. II. Filter performance in theory and modeling
-
H. Reucher, J. Silny, and G. Rau Spatial filtering of noninvasive multielectrode EMG. II. Filter performance in theory and modeling IEEE Trans. Biomed. Eng. 34 1987 106 113
-
(1987)
IEEE Trans. Biomed. Eng.
, vol.34
, pp. 106-113
-
-
Reucher, H.1
Silny, J.2
Rau, G.3
-
27
-
-
0022093412
-
Optimal conditions for the measurement of muscle fibre conduction velocity using surface electrode arrays
-
T. Sadoyama, T. Masuda, and H. Miyano Optimal conditions for the measurement of muscle fibre conduction velocity using surface electrode arrays Med. Biol. Eng. Comput. 23 1985 339 342
-
(1985)
Med. Biol. Eng. Comput.
, vol.23
, pp. 339-342
-
-
Sadoyama, T.1
Masuda, T.2
Miyano, H.3
-
28
-
-
0020513687
-
Electromyography reliability in maximal and submaximal isometric contractions
-
J.F Yang, and D.A. Winter Electromyography reliability in maximal and submaximal isometric contractions Arch. Phys. Med. Rehabil. 64 1983 417 420
-
(1983)
Arch. Phys. Med. Rehabil.
, vol.64
, pp. 417-420
-
-
Yang, J.F.1
Winter, D.A.2
|