메뉴 건너뛰기




Volumn 32, Issue 10, 2005, Pages 708-713

Non-invasive assessment of motor unit anatomy in jaw-elevator muscles

Author keywords

Fibre length; Innervation zone; Linear electrode arrays; Surface electromyography

Indexed keywords

ADULT; ARTICLE; CYTOLOGY; ELECTROMYOGRAPHY; FEMALE; HUMAN; INNERVATION; JAW; MALE; MASSETER MUSCLE; MASTICATORY MUSCLE; METHODOLOGY; MOTONEURON; MUSCLE CELL;

EID: 25844471622     PISSN: 0305182X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2005.01490.x     Document Type: Article
Times cited : (32)

References (30)
  • 1
    • 0026569723 scopus 로고
    • Heterogeneity of fiber and sarcomere length in the human masseter muscle
    • van Eijden TMGJ, Raadsheer MC. Heterogeneity of fiber and sarcomere length in the human masseter muscle. Anat Rec. 1992;232:78-84.
    • (1992) Anat Rec , vol.232 , pp. 78-84
    • Van Eijden, T.M.G.J.1    Raadsheer, M.C.2
  • 3
    • 0036546692 scopus 로고    scopus 로고
    • Stardardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle
    • Farina D, Madeleine P, Graven-Nielsen T, Merletti R, Arendt-Nielsen L. Stardardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle. Eur J Appl Physiol. 2002;86:469-478.
    • (2002) Eur J Appl Physiol , vol.86 , pp. 469-478
    • Farina, D.1    Madeleine, P.2    Graven-Nielsen, T.3    Merletti, R.4    Arendt-Nielsen, L.5
  • 4
    • 0022995453 scopus 로고
    • Effects of electrode location on myoelectric conduction velocity and median frequency estimates
    • Roy SH, De Luca CJ, Schneider J. Effects of electrode location on myoelectric conduction velocity and median frequency estimates. J Appl Physiol. 1986;61:1510-1517.
    • (1986) J Appl Physiol , vol.61 , pp. 1510-1517
    • Roy, S.H.1    De Luca, C.J.2    Schneider, J.3
  • 5
    • 0014786680 scopus 로고
    • Effects of skin electrode position on average electromyographic potentials
    • Zuniga N, Truong XT, Simons DG. Effects of skin electrode position on average electromyographic potentials. Arch Phys Med Rehabil. 1970;51:264-272.
    • (1970) Arch Phys Med Rehabil , vol.51 , pp. 264-272
    • Zuniga, N.1    Truong, X.T.2    Simons, D.G.3
  • 6
    • 0027176507 scopus 로고
    • The influence of electrode position on bipolar surface electromyogram recordings of the upper trapezius muscle
    • Jensen C, Vasseljen O, Westgaard RH. The influence of electrode position on bipolar surface electromyogram recordings of the upper trapezius muscle. Eur J Appl Physiol. 1993;67:266-273.
    • (1993) Eur J Appl Physiol , vol.67 , pp. 266-273
    • Jensen, C.1    Vasseljen, O.2    Westgaard, R.H.3
  • 7
  • 8
    • 0037290798 scopus 로고    scopus 로고
    • The linear electrode array: A useful tool with many applications
    • Merletti R, Farina D, Gazzoni M. The linear electrode array: a useful tool with many applications. J Electromyogr Kinesiol. 2003;13:37-47.
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 37-47
    • Merletti, R.1    Farina, D.2    Gazzoni, M.3
  • 9
    • 0023202908 scopus 로고
    • Skeletal muscles from which the propagation of motor unit action potentials is detectable with surface electrode arrays
    • Masuda T, Sadoyama T. Skeletal muscles from which the propagation of motor unit action potentials is detectable with surface electrode arrays. Electroencephalogr Clin Neurophysiol. 1987;67:421-427.
    • (1987) Electroencephalogr Clin Neurophysiol , vol.67 , pp. 421-427
    • Masuda, T.1    Sadoyama, T.2
  • 10
    • 0021892188 scopus 로고
    • The position of innervation zones in the biceps brachii investigated by surface electromyography
    • Masuda T, Miyano H, Sadoyama T. The position of innervation zones in the biceps brachii investigated by surface electromyography. IEEE Trans Biomed Eng. 1985;32:36-42.
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 36-42
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 11
    • 0029097156 scopus 로고
    • Innervation zones in the back muscles investigated by multichannel surface EMG
    • Shiraishi M, Masuda T, Sadoyama T, Okada M. Innervation zones in the back muscles investigated by multichannel surface EMG. J Electromyogr Kinesiol. 1995;9:161-168.
    • (1995) J Electromyogr Kinesiol , vol.9 , pp. 161-168
    • Shiraishi, M.1    Masuda, T.2    Sadoyama, T.3    Okada, M.4
  • 13
    • 0025502445 scopus 로고
    • Noninvasive estimation of the location of the end plate in the human masseter muscle using surface electromyograms with an electrode array
    • Iwasaki S, Tokunaga T, Baba S, Tanaka M, Kawazoe T. Noninvasive estimation of the location of the end plate in the human masseter muscle using surface electromyograms with an electrode array. J Osaka Dent Univ. 1990;24: 135-140.
    • (1990) J Osaka Dent Univ , vol.24 , pp. 135-140
    • Iwasaki, S.1    Tokunaga, T.2    Baba, S.3    Tanaka, M.4    Kawazoe, T.5
  • 14
    • 0032060084 scopus 로고    scopus 로고
    • Two-dimensional configuration of the myoneural junctions of human masticatory muscle detected with matrix electrode
    • Tokunaga T, Baba S, Tanaka M, Kashiwagi K, Kimura K, Kawazoe T. Two-dimensional configuration of the myoneural junctions of human masticatory muscle detected with matrix electrode. J Oral Rehab. 1998;25:329-334.
    • (1998) J Oral Rehab , vol.25 , pp. 329-334
    • Tokunaga, T.1    Baba, S.2    Tanaka, M.3    Kashiwagi, K.4    Kimura, K.5    Kawazoe, T.6
  • 16
    • 0018920580 scopus 로고
    • Basic classification of 150 dysgnathic subjects according to Ricketts, Steiner and Cervera
    • Bracco P, Vercellino V. Basic classification of 150 dysgnathic subjects according to Ricketts, Steiner and Cervera. Minerva Stomatol. 1980;29:1-38.
    • (1980) Minerva Stomatol , vol.29 , pp. 1-38
    • Bracco, P.1    Vercellino, V.2
  • 17
    • 0030949268 scopus 로고    scopus 로고
    • Architecture of the human jaw closing and jaw opening muscles
    • van Eijden TMGJ, Korfage JAM, Brugman P. Architecture of the human jaw closing and jaw opening muscles. Anat Rec. 1997;248:464-474.
    • (1997) Anat Rec , vol.248 , pp. 464-474
    • Van Eijden, T.M.G.J.1    Korfage, J.A.M.2    Brugman, P.3
  • 18
    • 0018378442 scopus 로고
    • Functional heterogeneity in a multipennate muscle
    • Herring SW, Grimm AF, Grimm BR. Functional heterogeneity in a multipennate muscle. Am J Anat. 1979;154:563-576.
    • (1979) Am J Anat , vol.154 , pp. 563-576
    • Herring, S.W.1    Grimm, A.F.2    Grimm, B.R.3
  • 19
    • 0026467947 scopus 로고
    • Electromyographic heterogeneity in the human masseter muscle
    • Blanskma NG, vanEijden TMGJ, Weijs WA. Electromyographic heterogeneity in the human masseter muscle. J Dent Res. 1992;71:47-52.
    • (1992) J Dent Res , vol.71 , pp. 47-52
    • Blanskma, N.G.1    VanEijden, T.M.G.J.2    Weijs, W.A.3
  • 20
    • 0029320273 scopus 로고
    • Electromyographic heterogeneity in the human temporalis and masseter muscles during static biting, open/close excursions, and chewing
    • Blanskma NG, van Eijden TMGJ. Electromyographic heterogeneity in the human temporalis and masseter muscles during static biting, open/close excursions, and chewing. J Dent Res. 1995;74:1318-1327.
    • (1995) J Dent Res , vol.74 , pp. 1318-1327
    • Blanskma, N.G.1    Van Eijden, T.M.G.J.2
  • 21
    • 0024671270 scopus 로고
    • EMG power spectrum patterns of anterior temporal and masseter muscle in children and adults
    • Yuen SWH, Hwang JCC, Poon PWF. EMG power spectrum patterns of anterior temporal and masseter muscle in children and adults. J Dent Res. 1989;68:800-804.
    • (1989) J Dent Res , vol.68 , pp. 800-804
    • Yuen, S.W.H.1    Hwang, J.C.C.2    Poon, P.W.F.3
  • 22
    • 0005067746 scopus 로고
    • Motor unit behaviour in three-dimensional bite force in human masseter
    • Hattori Y, Watanabe M, Sasaki K, Kikuchi M. Motor unit behaviour in three-dimensional bite force in human masseter. J Dent Res. 1991;70:553.
    • (1991) J Dent Res , vol.70 , pp. 553
    • Hattori, Y.1    Watanabe, M.2    Sasaki, K.3    Kikuchi, M.4
  • 23
    • 0036719056 scopus 로고    scopus 로고
    • Effect of sustained contraction on motor unit potentials and EMG power spectrum of human masticatory muscles
    • Chung JW, Kim C, McCall WD. Effect of sustained contraction on motor unit potentials and EMG power spectrum of human masticatory muscles. J Dent Res. 2002;81:646-649.
    • (2002) J Dent Res , vol.81 , pp. 646-649
    • Chung, J.W.1    Kim, C.2    McCall, W.D.3
  • 24
    • 0025500626 scopus 로고
    • Electromyographic heterogeneity in the human temporalis muscle
    • Blanskma NG, van Eijden TMGJ. Electromyographic heterogeneity in the human temporalis muscle. J Dent Res. 1990;69:1686-1690.
    • (1990) J Dent Res , vol.69 , pp. 1686-1690
    • Blanskma, N.G.1    Van Eijden, T.M.G.J.2
  • 25
    • 25844446432 scopus 로고    scopus 로고
    • Struttura e funzione dei muscoli mandibolari
    • McNeill C, ed. Milano: Scienza e Tecnica Dentistica Edizioni Internazionali
    • Hannam AG. Struttura e funzione dei muscoli mandibolari. In: McNeill C, ed. L'Occlusione Basi scientifiche e pratica clinica. Milano: Scienza e Tecnica Dentistica Edizioni Internazionali, 1999; 43-44.
    • (1999) L'Occlusione Basi Scientifiche e Pratica Clinica , pp. 43-44
    • Hannam, A.G.1
  • 28
    • 84939033845 scopus 로고
    • Spatial filtering of noninvasive multielectrode EMG: Part I - Introduction to measuring technique and applications
    • Reucher H, Rau G, Silny J. Spatial filtering of noninvasive multielectrode EMG: part I - introduction to measuring technique and applications. IEEE Trans Biomed Eng. 1987;34:98-105.
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 98-105
    • Reucher, H.1    Rau, G.2    Silny, J.3
  • 29
    • 0023289453 scopus 로고
    • Spatial filtering of noninvasive multielectrode EMG: Part II - Filter performance in theory and modelling
    • Reucher H, Silny J, Rau G. Spatial filtering of noninvasive multielectrode EMG: part II - filter performance in theory and modelling. IEEE Trans Biomed Eng. 1987;34:106-113.
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 106-113
    • Reucher, H.1    Silny, J.2    Rau, G.3
  • 30
    • 25844487966 scopus 로고    scopus 로고
    • Reproducibility of surface electromyography in human masseter and temporalis anterior muscle areas
    • in press
    • Castroflorio T, Icardi K, Torsello F, Deregibus A, Debemardi C, Bracco P. Reproducibility of surface electromyography in human masseter and temporalis anterior muscle areas. Cranio. 2004 (in press).
    • (2004) Cranio
    • Castroflorio, T.1    Icardi, K.2    Torsello, F.3    Deregibus, A.4    Debemardi, C.5    Bracco, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.