메뉴 건너뛰기




Volumn 42, Issue 4, 2004, Pages 455-466

Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays

Author keywords

Adhesive array; Ambulatory monitoring; Datalogger; Multi channel recording; Portable acquisition system; Surface EMG

Indexed keywords

ELECTRODE ARRAYS; ELECTROMYOGRAM (EMG) DEVICES; NEUROMUSCULAR SYSTEMS;

EID: 4444250956     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02350986     Document Type: Article
Times cited : (29)

References (40)
  • 2
    • 0038235828 scopus 로고    scopus 로고
    • 'Impedance and noise of the skin-electrode interface in surface EMG recordings'
    • Proc. XIVth ISEK Congress, Wien
    • Bottin, A., and Rebecchi, P. (2002): 'Impedance and noise of the skin-electrode interface in surface EMG recordings'. Proc. XIVth ISEK Congress, Wien, pp. 246-247
    • (2002) , pp. 246-247
    • Bottin, A.1    Rebecchi, P.2
  • 3
    • 0023280006 scopus 로고
    • 'A multiple-contact EMG recording array for mapping single muscle unit territories'
    • Chanaud, C. M., Pratt, C. A., and Loeb, G. E. (1987): 'A multiple-contact EMG recording array for mapping single muscle unit territories', J. Neurosci. Methods, 21, pp. 105-112
    • (1987) J. Neurosci. Methods , vol.21 , pp. 105-112
    • Chanaud, C.M.1    Pratt, C.A.2    Loeb, G.E.3
  • 4
    • 0031195287 scopus 로고    scopus 로고
    • 'Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters'
    • Disselhorst-Klug, C., Silny, J., and Rau, G. (1997): 'Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters', IEEE Trans. Biomed. Eng., 44, pp. 567-574
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 567-574
    • Disselhorst-Klug, C.1    Silny, J.2    Rau, G.3
  • 5
    • 0035125982 scopus 로고    scopus 로고
    • 'Propagation disturbance of motor unit action potentials during transient paresis in generalized myotonia: A high-density surface EMG study'
    • Drost, G., Blok, J. H., Stegeman, D. F., van Dijk, J. P., van Engelen, B. G., and Zwarts, M. J. (2001): 'Propagation disturbance of motor unit action potentials during transient paresis in generalized myotonia: a high-density surface EMG study', Brain, 124, pp. 352-360
    • (2001) Brain , vol.124 , pp. 352-360
    • Drost, G.1    Blok, J.H.2    Stegeman, D.F.3    van Dijk, J.P.4    van Engelen, B.G.5    Zwarts, M.J.6
  • 6
    • 0035133447 scopus 로고    scopus 로고
    • 'Surface electromyography analysis in long-term recordings: Application to head rest comfort in cars'
    • Duchene, J., and Lamotte, T. (2001): 'Surface electromyography analysis in long-term recordings: application to head rest comfort in cars', Ergonomics, 44, pp. 313-327
    • (2001) Ergonomics , vol.44 , pp. 313-327
    • Duchene, J.1    Lamotte, T.2
  • 7
    • 0034015483 scopus 로고    scopus 로고
    • 'Non-invasive estimation of motor unit conduction velocity distribution using linear electrode arrays'
    • Farina, D., Fortunato, E., and Merletti, R. (2000): 'Non-invasive estimation of motor unit conduction velocity distribution using linear electrode arrays', IEEE Trans. Biomed. Eng., 47, pp. 380-388
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 380-388
    • Farina, D.1    Fortunato, E.2    Merletti, R.3
  • 8
    • 0035047686 scopus 로고    scopus 로고
    • 'Estimation of single motor unit conduction velocity from myoelectric signals detected with linear electrode arrays'
    • Farina, D., Muhammad, W., Fortunato, E., Meste, O., Merletti, R., and Rix, H. (2001): 'Estimation of single motor unit conduction velocity from myoelectric signals detected with linear electrode arrays', Med. Biol. Eng. Comput., 39, pp. 225-236
    • (2001) Med. Biol. Eng. Comput. , vol.39 , pp. 225-236
    • Farina, D.1    Muhammad, W.2    Fortunato, E.3    Meste, O.4    Merletti, R.5    Rix, H.6
  • 9
    • 0036092520 scopus 로고    scopus 로고
    • 'Motor unit recruitment strategies investigated by surface EMG variables'
    • Farina, D., Fosci, M., and Merletti, R. (2002a): 'Motor unit recruitment strategies investigated by surface EMG variables', J. Appl. Physiol., 92, pp. 235-247
    • (2002) J. Appl. Physiol. , vol.92 , pp. 235-247
    • Farina, D.1    Fosci, M.2    Merletti, R.3
  • 10
    • 0036546692 scopus 로고    scopus 로고
    • 'Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle'
    • Farina, D., Madeleine, P., Graven-Nielsen, T., Merletti, R., and Arendt-Nielsen, L. (2002b): 'Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle', Eur. J. Appl. Physiol., 86, pp. 469-478
    • (2002) Eur. J. Appl. Physiol. , vol.86 , pp. 469-478
    • Farina, D.1    Madeleine, P.2    Graven-Nielsen, T.3    Merletti, R.4    Arendt-Nielsen, L.5
  • 11
    • 0037196868 scopus 로고    scopus 로고
    • 'A spike triggered averaging technique for high resolution assessment of single motor unit conduction velocity during fatiguing voluntary contractions'
    • Farina, D., Arendt-Nielsen, L., Merletti, R., and Graven-Nielsen, T. (2002c): 'A spike triggered averaging technique for high resolution assessment of single motor unit conduction velocity during fatiguing voluntary contractions', J. Neurosci. Methods, 115, pp. 1-12
    • (2002) J. Neurosci. Methods , vol.115 , pp. 1-12
    • Farina, D.1    Arendt-Nielsen, L.2    Merletti, R.3    Graven-Nielsen, T.4
  • 12
    • 2942553128 scopus 로고    scopus 로고
    • 'Assessment of average muscle fiber conduction velocity from surface EMG signals during fatiguing dynamic contractions'
    • in press
    • Farina, D., Pozzo, M., Merlo, E., Bottin, A., and Merletti, R. (2004): 'Assessment of average muscle fiber conduction velocity from surface EMG signals during fatiguing dynamic contractions', IEEE Trans. Biomed. Eng. (in press)
    • (2004) IEEE Trans. Biomed. Eng.
    • Farina, D.1    Pozzo, M.2    Merlo, E.3    Bottin, A.4    Merletti, R.5
  • 13
    • 4444326851 scopus 로고    scopus 로고
    • 'EmgAcq 2.0 user manual'
    • Technical Report, Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Centro di Bioingegneria, Dip. di Elettronica, Politecnico di Torino, Torino, Italy
    • Gazzoni, M. (2003): 'EmgAcq 2.0 user manual'. Technical Report, Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Centro di Bioingegneria, Dip. di Elettronica, Politecnico di Torino, Torino, Italy
    • (2003)
    • Gazzoni, M.1
  • 14
    • 0038523785 scopus 로고    scopus 로고
    • 'Modular data logger system for physical workload measurements'
    • Hansson, G. A., Asterland, P., and Kellerman, M. (2003): 'Modular data logger system for physical workload measurements', Ergonomics, 46, pp. 407-415
    • (2003) Ergonomics , vol.46 , pp. 407-415
    • Hansson, G.A.1    Asterland, P.2    Kellerman, M.3
  • 15
    • 4444257023 scopus 로고    scopus 로고
    • 'NEW results from EMG signals and their integration with other findings'
    • Proc. International Symposium on Neuromuscular Assessment in the Elderly Worker, Torino, Italy, (in press)
    • Hermens, H. J., and Sjøgaard, G. (2004): 'NEW results from EMG signals and their integration with other findings'. Proc. International Symposium on Neuromuscular Assessment in the Elderly Worker, Torino, Italy, (in press)
    • (2004)
    • Hermens, H.J.1    Sjøgaard, G.2
  • 16
    • 0037410155 scopus 로고    scopus 로고
    • 'Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings'
    • Hewson, D. J., Hogrel, J. Y., Langeron, Y., and Duchene, J. (2003): 'Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings', J. Electromyogr. Kinesiol., 13, pp. 273-279
    • (2003) J. Electromyogr. Kinesiol. , vol.13 , pp. 273-279
    • Hewson, D.J.1    Hogrel, J.Y.2    Langeron, Y.3    Duchene, J.4
  • 17
    • 0015588559 scopus 로고
    • '60-Hz interference in electro-cardiography'
    • Huhta, J. C., and Webster, J. G. (1973): '60-Hz interference in electro-cardiography', IEEE Trans. Biomed. Eng., 20, pp. 657-658
    • (1973) IEEE Trans. Biomed. Eng. , vol.20 , pp. 657-658
    • Huhta, J.C.1    Webster, J.G.2
  • 18
    • 0343628048 scopus 로고    scopus 로고
    • 'Magnetic stimulation-induced modulations of motor unit firings extracted from multi-channel surface EMG'
    • Kleine, B. U., Blok, J. H., Oostenveld, R., Praamstra, P., and Stegeman, D. F. (2000): 'Magnetic stimulation-induced modulations of motor unit firings extracted from multi-channel surface EMG', Muscle Nerve, 23, pp. 1005-1015
    • (2000) Muscle Nerve , vol.23 , pp. 1005-1015
    • Kleine, B.U.1    Blok, J.H.2    Oostenveld, R.3    Praamstra, P.4    Stegeman, D.F.5
  • 19
    • 84995006566 scopus 로고
    • 'The clinical use of multichannel surface electromyography'
    • Kumagai, K., and Yamada, M. (1991): 'The clinical use of multichannel surface electromyography', Acta Paediatr. Jpn., 33, pp. 228-237
    • (1991) Acta Paediatr. Jpn. , vol.33 , pp. 228-237
    • Kumagai, K.1    Yamada, M.2
  • 20
    • 4444245559 scopus 로고    scopus 로고
    • 'NEW results from questionnaires, clinical and functional tests'
    • Proc. International Symposium on Neuromuscular Assessment in the Elderly Worker, Torino, Italy, (in press)
    • Läubli, T., and Sjøgaard, G. (2004): 'NEW results from questionnaires, clinical and functional tests'. Proc. International Symposium on Neuromuscular Assessment in the Elderly Worker, Torino, Italy, (in press)
    • (2004)
    • Läubli, T.1    Sjøgaard, G.2
  • 21
    • 0020972793 scopus 로고
    • 'The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays'
    • Masuda, T., Miyano, H., and Sadoyama, T. (1983a): 'The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays', Electroenceph. Clin. Neurophysiol., 56, pp. 597-603
    • (1983) Electroenceph. Clin. Neurophysiol. , vol.56 , pp. 597-603
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 22
    • 0020972793 scopus 로고
    • 'The distribution of myoneural junctions in the biceps brachii investigated by surface electromyography'
    • Masuda, T., Miyano, H., and Sadoyama, T. (1983b): 'The distribution of myoneural junctions in the biceps brachii investigated by surface electromyography', Electroenceph. Clin. Neurophysiol., 56, pp. 597-603
    • (1983) Electroenceph. Clin. Neurophysiol. , vol.56 , pp. 597-603
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 23
    • 0021828128 scopus 로고
    • 'A surface electrode array for detecting action potential trains of single motor units'
    • Masuda, T., Miyano, H., and Sadoyama, T. (1985): 'A surface electrode array for detecting action potential trains of single motor units', Electroenceph. Clin. Neurophysiol., 60, pp. 435-443
    • (1985) Electroenceph. Clin. Neurophysiol. , vol.60 , pp. 435-443
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 24
    • 0021286283 scopus 로고
    • 'High-resolution alignment of sampled waveforms'
    • McGill, K. C., and Dorfman, L. J. (1984): 'High-resolution alignment of sampled waveforms', IEEE Trans. Biomed. Eng., 31, pp. 462-468
    • (1984) IEEE Trans. Biomed. Eng. , vol.31 , pp. 462-468
    • McGill, K.C.1    Dorfman, L.J.2
  • 25
    • 0037290798 scopus 로고    scopus 로고
    • 'The linear electrode array: A useful tool with many applications'
    • Merletti, R., Farina, D., and Gazzoni, M. (2003): 'The linear electrode array: a useful tool with many applications', J. Electromyogr. Kinesiol., 13, pp. 37-47
    • (2003) J. Electromyogr. Kinesiol. , vol.13 , pp. 37-47
    • Merletti, R.1    Farina, D.2    Gazzoni, M.3
  • 27
    • 0029361180 scopus 로고
    • 'Two miniature monitors for long-term ambulatory studies'
    • Perkins, M. A., Dicken, P., Hyde, D. J., and Grant, L. J. (1995): 'Two miniature monitors for long-term ambulatory studies', Med. Eng. Phys., 17, pp. 410-415
    • (1995) Med. Eng. Phys. , vol.17 , pp. 410-415
    • Perkins, M.A.1    Dicken, P.2    Hyde, D.J.3    Grant, L.J.4
  • 28
    • 85076080305 scopus 로고    scopus 로고
    • 'Electromyography: Detection, processing and applications'
    • Moore J., and Zouridakis, G. (Eds): (CRC Press, 2003)
    • Pozzo, M., Farina, D., and Merletti, R. (2003a): 'Electromyography: detection, processing and applications', in MOORE, J., and Zouridakis, G. (Eds): 'Biomedical technology and devices handbook' (CRC Press, 2003), pp. 4.1-4.66
    • (2003) Biomedical Technology and Devices Handbook
    • Pozzo, M.1    Farina, D.2    Merletti, R.3
  • 29
    • 2642540975 scopus 로고    scopus 로고
    • 'Muscle fiber conduction velocity estimated from surface EMG signals during explosive dynamic contractions'
    • Pozzo, M., Merlo, E., Farina, D., Antonutto, G., Merletti, R., and di Prampero, P. E. (2004): 'Muscle fiber conduction velocity estimated from surface EMG signals during explosive dynamic contractions', Muscle Nerve, 29, pp. 823-833
    • (2004) Muscle Nerve , vol.29 , pp. 823-833
    • Pozzo, M.1    Merlo, E.2    Farina, D.3    Antonutto, G.4    Merletti, R.5    di Prampero, P.E.6
  • 30
    • 0029361138 scopus 로고
    • 'A high-resolution large array (HRLA) surface EMG system'
    • Prutchi, D. (1995): 'A high-resolution large array (HRLA) surface EMG system', Med. Eng. Phys., 17, pp. 442-454
    • (1995) Med. Eng. Phys. , vol.17 , pp. 442-454
    • Prutchi, D.1
  • 31
    • 0031148596 scopus 로고    scopus 로고
    • 'Noninvasive approach to motor unit characterization: Muscle structure, membrane dynamics and neuronal control'
    • Rau, G., Disselhorst-Klug, C., and Silny, J. (1997): 'Noninvasive approach to motor unit characterization: muscle structure, membrane dynamics and neuronal control', J. Biomech., 30, pp. 441-446
    • (1997) J. Biomech. , vol.30 , pp. 441-446
    • Rau, G.1    Disselhorst-Klug, C.2    Silny, J.3
  • 32
    • 0036262989 scopus 로고    scopus 로고
    • 'What do we learn from motor unit action potentials in surface electromyography?'
    • Roeleveld, K., and Stegeman, D. F. (2002): 'What do we learn from motor unit action potentials in surface electromyography?', Muscle Nerve, 11, pp. S92-S97
    • (2002) Muscle Nerve , vol.11
    • Roeleveld, K.1    Stegeman, D.F.2
  • 38
    • 0003526149 scopus 로고
    • 'Medical instrumentation: Application and design'
    • (Ed.) (Houghton Mifflin, 1992)
    • Webster, J. G. (Ed.) (1992): 'Medical instrumentation: application and design' (Houghton Mifflin, 1992)
    • (1992)
    • Webster, J.G.1
  • 39
    • 0035139843 scopus 로고    scopus 로고
    • 'Surface electromyography using electrode arrays: A study of motor neuron disease'
    • Wood, S. M., Jarratt, J. A., Barker, A. T., and Brown, B. H. (2001): 'Surface electromyography using electrode arrays: a study of motor neuron disease', Muscle Nerve, 24, pp. 223-230
    • (2001) Muscle Nerve , vol.24 , pp. 223-230
    • Wood, S.M.1    Jarratt, J.A.2    Barker, A.T.3    Brown, B.H.4
  • 40
    • 0038121674 scopus 로고    scopus 로고
    • 'Multichannel surface EMG: Basic aspects and clinical utility'
    • Zwarts, M. J., and Stegeman, D. F. (2003): 'Multichannel surface EMG: basic aspects and clinical utility', Muscle Nerve, 28, pp. 1-17
    • (2003) Muscle Nerve , vol.28 , pp. 1-17
    • Zwarts, M.J.1    Stegeman, D.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.