메뉴 건너뛰기




Volumn 53, Issue 4, 2006, Pages 712-719

Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis

Author keywords

Force estimation; Heterogeneous muscle fiber architecture; Human; Principal component analysis; Redundancy; Surface electromyography

Indexed keywords

FORCE ESTIMATION; HETEROGENEOUS MUSCLE FIBER ARCHITECTURE; ROOT MEAN SQUARE DIFFERENCE (RMSD); SURFACE ELECTROMYOGRAPHY;

EID: 33645317089     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2006.870246     Document Type: Article
Times cited : (146)

References (23)
  • 1
    • 0029239549 scopus 로고
    • Multiple site electromyograph amplitude estimation
    • Feb.
    • E. A. Clancy and N. Hogan, "Multiple site electromyograph amplitude estimation," IEEE Trans. Biomed. Eng., vol. 42, no. 2, pp. 203-211, Feb. 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.2 , pp. 203-211
    • Clancy, E.A.1    Hogan, N.2
  • 2
    • 0019226632 scopus 로고
    • Myoelectric signal processing: Optimal estimation applied to electromyography - Part II: Experimental demonstration of optimal myoprocessor performance
    • N. Hogan and R. W. Mann, "Myoelectric signal processing: optimal estimation applied to electromyography - part II: experimental demonstration of optimal myoprocessor performance," IEEE Trans. Biomed. Eng., vol. 27, pp. 396-410, 1980.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , pp. 396-410
    • Hogan, N.1    Mann, R.W.2
  • 3
    • 0019226631 scopus 로고
    • Myoelectric signal processing: Optimal estimation applied to electromyography - Part I: Derivation of the optimal myoprocessor
    • _, "Myoelectric signal processing: optimal estimation applied to electromyography - part I: derivation of the optimal myoprocessor," IEEE Trans. Biomed. Eng., vol. BME-27, pp. 382-395, 1980.
    • (1980) IEEE Trans. Biomed. Eng. , vol.BME-27 , pp. 382-395
  • 4
    • 11844264542 scopus 로고    scopus 로고
    • Toward optimal multi-channel EMG electrode configurations in muscle force estimation: A high density EMG study
    • D. Staudenmann, I. Kingma, D. F. Stegeman, and J. H. van Dieen, "Toward optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG study," J. Electromyogr. Kinesiol., vol. 15, pp. 1-11, 2005.
    • (2005) J. Electromyogr. Kinesiol. , vol.15 , pp. 1-11
    • Staudenmann, D.1    Kingma, I.2    Stegeman, D.F.3    Van Dieen, J.H.4
  • 5
    • 0030973129 scopus 로고    scopus 로고
    • The use of surface electromyography in biomechanics
    • C. J. de Luca, "The use of surface electromyography in biomechanics," J. Appl. Biomech., vol. 13, 1997.
    • (1997) J. Appl. Biomech. , vol.13
    • De Luca, C.J.1
  • 6
    • 0002724620 scopus 로고    scopus 로고
    • The recommendation for sensors and sensor placement procedures for surface electromyography
    • Enschede, The Netherlands: Roessingh Research and Development
    • B. Freriks, H. Hermens, C. Disselhorst-Klug, and G. Rau, "The recommendation for sensors and sensor placement procedures for surface electromyography," in Deliverable 8 of SENIAM European Concerted Action. Enschede, The Netherlands: Roessingh Research and Development, 1999.
    • (1999) Deliverable 8 of SENIAM European Concerted Action
    • Freriks, B.1    Hermens, H.2    Disselhorst-Klug, C.3    Rau, G.4
  • 7
    • 0033043216 scopus 로고    scopus 로고
    • Modeling of surface myoelectric signals. I. Model implementation
    • Jul.
    • R. Merletti, L. Lo Conte, E. Avignone, and P. Guglielminotti, "Modeling of surface myoelectric signals. I. Model implementation," IEEE Trans. Biomed. Eng., vol. 46, no. 7, pp. 810-820, Jul. 1999.
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , Issue.7 , pp. 810-820
    • Merletti, R.1    Lo Conte, L.2    Avignone, E.3    Guglielminotti, P.4
  • 8
    • 0023202908 scopus 로고
    • Skeletal muscles from which the propagation of motor unit action potentials is detectable with a surface electrode array
    • T. Masuda and T. Sadoyama, "Skeletal muscles from which the propagation of motor unit action potentials is detectable with a surface electrode array," Electroencephalogr. Clin. Neurophysiol., vol. 67, pp. 421-427, 1987.
    • (1987) Electroencephalogr. Clin. Neurophysiol. , vol.67 , pp. 421-427
    • Masuda, T.1    Sadoyama, T.2
  • 10
    • 0032951416 scopus 로고    scopus 로고
    • Predictability of in vivo changes in pennation angle of human tibialis anterior muscle from rest to maximum isometric dorsiflexion
    • C. N. Maganaris and V. Baltzopoulos, "Predictability of in vivo changes in pennation angle of human tibialis anterior muscle from rest to maximum isometric dorsiflexion," Eur. J. Appl. Physiol. Occupat. Physiol., vol. 79, pp. 294-297, 1999.
    • (1999) Eur. J. Appl. Physiol. Occupat. Physiol. , vol.79 , pp. 294-297
    • Maganaris, C.N.1    Baltzopoulos, V.2
  • 11
    • 0031195287 scopus 로고    scopus 로고
    • Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters
    • Jul.
    • C. Disselhorst-Klug, J. Silny, and G. Rau, "Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters," IEEE Trans. Biomed. Eng., vol. 44, no. 7, pp. 567-574, Jul. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , Issue.7 , pp. 567-574
    • Disselhorst-Klug, C.1    Silny, J.2    Rau, G.3
  • 14
    • 0025483042 scopus 로고
    • High-quality recording of bioelectric events. Part 1. Interference reduction, theory and practice
    • A. C. M. van Rijn, A. Peper, and C. A. Grimbergen, "High-quality recording of bioelectric events. Part 1. Interference reduction, theory and practice," Med. Biol Eng. Comput., vol. 28, pp. 389-397, 1990.
    • (1990) Med. Biol Eng. Comput. , vol.28 , pp. 389-397
    • Van Rijn, A.C.M.1    Peper, A.2    Grimbergen, C.A.3
  • 17
    • 0004051562 scopus 로고    scopus 로고
    • The state of the art on sensors and sensor placement procedures for surface electromyography. Deliverable 5 of the SENIAM European concerted action. Enschede, the Netherlands: Roessingh Research and Development
    • Enschede, The Netherlands: Roessingh Research and Development
    • H. J. Hermens and B. Freriks, "The state of the art on sensors and sensor placement procedures for surface electromyography. Deliverable 5 of the SENIAM European concerted action. Enschede, The Netherlands: Roessingh Research and Development," in Deliverable 5 of SENIAM European Concerted Action. Enschede, The Netherlands: Roessingh Research and Development, 1997.
    • (1997) Deliverable 5 of SENIAM European Concerted Action
    • Hermens, H.J.1    Freriks, B.2
  • 18
    • 0031401931 scopus 로고    scopus 로고
    • Near- and far-fields: Source characteristics and the conducting medium in neurophysiology
    • D. F. Stegeman, D. Dumitru, J. C. King, and K. Roeleveld, "Near- and far-fields: source characteristics and the conducting medium in neurophysiology," J. Clin. Neurophysiol., vol. 14, pp. 429-442, 1997.
    • (1997) J. Clin. Neurophysiol. , vol.14 , pp. 429-442
    • Stegeman, D.F.1    Dumitru, D.2    King, J.C.3    Roeleveld, K.4
  • 19
    • 16544379884 scopus 로고    scopus 로고
    • Less is more: High pass filtering, to remove up to 99% of the surface EMG signal power, improves EMG-based biceps brachii muscle force estimates
    • J. R. Potvin and S. H. Brown, "Less is more: high pass filtering, to remove up to 99% of the surface EMG signal power, improves EMG-based biceps brachii muscle force estimates," J. Electromyogr. Kinesiol., vol. 14, pp. 389-399, 2004.
    • (2004) J. Electromyogr. Kinesiol. , vol.14 , pp. 389-399
    • Potvin, J.R.1    Brown, S.H.2
  • 20
    • 0344837760 scopus 로고    scopus 로고
    • Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle
    • Mar.
    • D. Farina, L. Arendt-Nielsen, R. Merletti, B. Indino, and T. Graven-Nielsen, "Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle," IEEE Trans. Biomed. Eng., vol. 50, no. 3, pp. 354-364, Mar. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.3 , pp. 354-364
    • Farina, D.1    Arendt-Nielsen, L.2    Merletti, R.3    Indino, B.4    Graven-Nielsen, T.5
  • 21
    • 0038121674 scopus 로고    scopus 로고
    • Multichannel surface EMG: Basic aspects and clinical utility
    • M. J. Zwarts and D. F. Stegeman, "Multichannel surface EMG: basic aspects and clinical utility," Muscle Nerve, vol. 28, pp. 1-17, 2003.
    • (2003) Muscle Nerve , vol.28 , pp. 1-17
    • Zwarts, M.J.1    Stegeman, D.F.2
  • 22
    • 0028356239 scopus 로고
    • Single site electromyograph amplitude estimation
    • Feb.
    • E. A. Clancy and N. Hogan, "Single site electromyograph amplitude estimation," IEEE Trans. Biomed. Eng., vol. 41, no. 2, pp. 159-167, Feb. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , Issue.2 , pp. 159-167
    • Clancy, E.A.1    Hogan, N.2
  • 23
    • 0036166846 scopus 로고    scopus 로고
    • Sampling, noise-reduction and amplitude estimation issues in surface electromyography
    • E. A. Clancy, E. L. Morin, and R. Merletti, "Sampling, noise-reduction and amplitude estimation issues in surface electromyography, " J. Electromyogr. Kinesiol., vol. 12, pp. 1-16, 2002.
    • (2002) J. Electromyogr. Kinesiol. , vol.12 , pp. 1-16
    • Clancy, E.A.1    Morin, E.L.2    Merletti, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.